LG LQN120HV4 Low Wall Console
Product Information
- Product Name: LQ120HV4 Single Zone Low Wall Console
- Outdoor Unit (ODU): LUU127HV
- Indoor Unit (IDU): LQN120HV4
Performance:
- Cooling: 4,500 ~ 10,200 ~ 13,460 Btu/h
- SEER2: 20.8
- EER2: 12.6
- Heating: 5,970 ~ 13,000 ~ 15,000 Btu/h
- HSPF2: 10.2
Electrical:
- Outdoor Unit:
- MOP (Maximum Overcurrent Protection): 15 A
- MCA (Minimum Circuit Ampacity): 12.3 A
- Cooling Rated Amps: 9.95 A
- Heating Rated Amps: 9.95 A
- Compressor Amps: 9.0 A
- Fan Motor (IDU + ODU) Amps: 0.7 + 0.25 A
- Cooling Power Input: 0.4 ~ 0.81 ~ 1.35 kW
- Heating Power Input: 0.55 ~ 1.25 ~ 1.58 kW
- Piping:
- 4,500 ~ 10,200 ~ 13,460 Btu/h
- EER: 9.0
- 5,970 ~ 13,000 ~ 15,000 Btu/h
- 208-230/60/1
Features:
- Included Accessories: Wireless Remote Controller – AKB75735410
- Optional Accessories: MultiSITETM CRC1, MultiSITE CRC1+, MultiSITE Comm. Mgr., AC Smart 5, Simple Controller, Wi-Fi module with cable, Low Ambient Wind Baffle, Drain Pan Heater, Dry Contact for Thermostat, Simple Dry Contact, Dry Contact for Economizer, Premium Remote Controller, PI-485
System Data:
- Operating Temperature Range: 0 to 118°F
- Operating Humidity Range: -4 to 64°F
- ODU Net / Shipping Weight: 49 / 52 lbs.
- IDU Net / Shipping Weight: 39 / 32 / 27 lbs.
- Heat Exchanger Coating: GoldFinTM
- Fan:
- ODU Type: Propeller
- IDU Type: Sirocco
- Fan Speeds (Fan/Cool/Heat): 4 / 5 / 5
- Fan Quantity (ODU + IDU): 1 + 1
- Motor/Drive: Brushless Digitally Controlled/Direct
- ODU Air Circulation (CFM): 988
- Air Flow (Max/H/M/L) (CFM): 353 / 318 / 244 / 184
- Dehumidification Rate (pts/hr): 2.5
Notes:
- For a complete list of available accessories, contact your LG representative.
- For continual product development, LG reserves the right to change specifications without notice.
Product Usage Instructions
To use the LQ120HV4 Single Zone Low Wall Console, follow these steps:
- Ensure that the outdoor unit (ODU) is properly installed and connected to the indoor unit (IDU) using appropriate piping.
- Connect the electrical supply to the outdoor unit according to the specified voltage and frequency (208-230/60/1).
- Check the electrical ratings of the outdoor unit, including maximum overcurrent protection (MOP), minimum circuit ampacity (MCA), cooling and heating rated amps, compressor amps, and fan motor amps.
- Install the included wireless remote controller (AKB75735410) for easy control of the system.
- Optional accessories such as MultiSITETM CRC1, MultiSITE CRC1+, MultiSITE Comm. Mgr., AC Smart 5, Simple Controller, Wi-Fi module with cable, Low Ambient Wind Baffle, Drain Pan Heater, Dry Contact for Thermostat, Simple Dry Contact, Dry Contact for Economizer, Premium Remote Controller, and PI-485 can be added as per your requirements.
- Refer to the system data for the operating temperature and humidity ranges.
- Make sure to properly clean and maintain the heat exchanger coating (GoldFinTM) for efficient operation.
- Understand the fan specifications, including the ODU and IDU types, fan speeds for fan/cool/heat modes, fan quantity, motor/drive type, air circulation, air flow rates (max/high/medium/low), and dehumidification rate.
- Keep in mind that LG may change specifications without notice for continual product development.
LQ120HV4 Single Zone Low Wall Console Outdoor Unit (ODU) – LUU127HV,
Indoor Unit (IDU) – LQN120HV4
Performance:
- Cooling:
- Cooling (Min~Rated~Max, Btu/h): 4,500 ~ 10,200 ~ 13,460
- SEER2: 20.8
- EER2: 12.6
- SEER – Seasonal Energy Efficiency Ratio EER – Energy Efficiency Ratio
Heating
- Heating (Min~Rated~Max, Btu/h): 5,970 ~ 13,000 ~ 15,000
- HSPF2: 10.2
- HSPF – Heating Seasonal Performance Factor
- Cooling Nominal Test Conditions:
- Indoor: 80°F DB / 67°F WB
- Outdoor: 95°F DB / 75°F WB
- Heating Nominal Test Conditions
- Indoor: 70°F DB / 60°F WB
- Outdoor: 47°F DB / 43°F WB
Electrical :
- Power Supply1 (V/Hz/Ø): 208-230/60/1
- Outdoor Unit:
- MOP (A): 15
- MCA (A): 12.3
- Cooling Rated Amps (A): 9.95
- Heating Rated Amps (A): 9.95
- Compressor(A): 9.0
- Fan Motor (IDU + ODU) (A): 0.7 + 0.25
- Cooling Power Input (kW): 0.4 ~ 0.81 ~ 1.35
- Heating Power Input (kW): 0.55 ~ 1.25 ~ 1.58
MOP
- Maximum Overcurrent Protection MCA
- Minimum Circuit Ampacity
Piping:
- Liquid Line (in., O.D.) 1/4
- Vapor Line (in., O.D.): 3/8
- Additional Refrigerant (oz./ft.): 0.22
- Max. Pipe Length² (ft.): 66
- Piping Length (no add’l refrig., ft.): 24.6
- Max. Elevation (ft.): 49
Features
- Hot start
- Inverter (variable speed fan)
- Auto restart
- Control lock
- Group control
- Timer (on/off)
- Sleep Mode
- Optional Wi-Fi Control
Included Accessories:
- Wireless Remote Controller — AKB75735410
Optional Accessories:
- MultiSITE™ CRC1 – PREMTBVC0
- MultiSITE CRC1+ – PREMTBVC1
- MultiSITE Comm. Mgr. – PBACNBTR0A
- AC Smart 5 – PACS5A000
- Simple Controller – PREMTC00U
- Wi-Fi module with cable – PWFMDD200
- Low Ambient Wind Baffle (Cooling operation to -4°F) ZLABGP01A
- Drain Pan Heater – PQSH1202
- Dry Contact for Thermostat – PDRYCB320
- Simple Dry Contact (1 Contact, 24VAC external power) – PDRYCB100
- Dry Contact for Economizer – PDRYCB400
- Premium Remote Controller – PREMTA000
- PI-485 – PMNFP14A1
Operating Range
- Outdoor Unit:
- Cooling (°F DB):0 to 118
- Heating (°F WB): -4 to 64
- Indoor Unit:
- Cooling (°F WB): 57 to 77
- Heating (°F DB): 59 to 81
System Data:
- Refrigerant Type: R410A
- Refrigerant Control: EEV
- Refrigerant Charge (lbs.): 2.425
- ODU Sound Pressure Max (Cool / Heat) ±3 dB(A)3: 49 / 52
- IDU Sound Pressure (H/M/L) ±3 dB(A)3: 39 / 32 / 27
- ODU Net / Shipping Weight (lbs.): 74.5 / 80
- IDU Net / Shipping Weight (lbs.): 35.9 / 42.5
- Heat Exchanger Coating: GoldFin™
Fan
- ODU Type: Propeller
- IDU Type: Sirocco
- Fan Speeds (Fan/Cool/Heat): 4/5/5
- Fan Quantity (ODU + IDU): 1 + 1
- Motor/Drive: Brushless Digitally Controlled/Direct
- ODU Air Circulation (CFM): 988
- Air Flow ( Max/ H/M/L) (CFM): 353 / 318 / 244 / 184
- Dehumidification Rate (pts/hr): 2.5
Notes
- Acceptable operating voltage: 187V-253V.
- Piping lengths are equivalent.
- Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
- All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and is to be minimum four-conductor, 14 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
- See Engineering Manual for sensible and latent capacities.
- Power wiring cable size must comply with the applicable local and national code.
- The indoor unit comes with a dry helium charge.
- This data is rated 0 ft. above sea level, with 24.6 ft. of refrigerant line and a 0 ft. level difference between outdoor and indoor units.
- Must follow installation instructions in the applicable LG installation manual.
- For a complete list of available accessories, contact your LG representative.
- For continual product development, LG reserves the right to change specifications without notice.
- © LG Electronics U.S.A., Inc. , Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com