GTSimulators com BPBF200 Bone Fracture Ultrasound Training User Guide

June 12, 2024
GTSimulators com

GTSimulators com BPBF200 Bone Fracture Ultrasound Training

GTSimulators-com-BPBF200-Bone-Fracture-Ultrasound-Training-
product

Product Information

The CAE Blue PhantomTM ultrasound training model is a medical training device designed to simulate ultrasound scanning and ultrasound-guided procedures. It is latex-free and can be used for educational purposes.

Cautions and Warnings
Please read the user guide, including all cautions and warnings, before using the CAE Blue PhantomTM ultrasound training model. Incorrect use of the product may result in unsafe conditions and void your warranty. Keep this information for future reference.

General Precautions
When cleaning the CAE Blue PhantomTM ultrasound training model, avoid using large amounts of liquid to wash it.

Service and Repair
For service and repair of the CAE Blue PhantomTM ultrasound training model, please refer to the user guide or contact the manufacturer for assistance.

Product Usage Instructions

Using the Training Model

  1. Setup: Follow the instructions provided in the user guide to set up the CAE Blue PhantomTM ultrasound training model for use.
  2. Training: Use the training model to practice ultrasound scanning techniques and ultrasound-guided procedures. Refer to the user guide for specific instructions on different training scenarios.

Ultrasound Scanning
To practice ultrasound scanning, position the ultrasound probe on the designated areas of the training model’s anatomy. Use the controls and settings on the ultrasound machine to adjust the image and perform various scanning techniques.

Ultrasound-guided Procedures
To practice ultrasound-guided procedures, follow the user guide’s instructions for specific procedures such as needle insertion or catheter placement. Use the ultrasound image to guide your actions and ensure accurate placement.

Care and Maintenance

Storage and Transport
When not in use, store the CAE Blue PhantomTM ultrasound training model in a clean and dry environment. Avoid exposing it to extreme temperatures or direct sunlight. When transporting the training model, ensure proper protection to prevent damage.

Cleaning
To clean the CAE Blue PhantomTM ultrasound training model, follow the cleaning instructions provided in the user guide. Use mild cleaning agents and avoid using large amounts of liquid to wash it.

Help and Technical Assistance
If you require help or technical assistance with the CAE Blue PhantomTM ultrasound training model, refer to the user guide for contact information or reach out to the manufacturer for support.

Disclaimer

This product is a simulation device designed for training and demonstration purposes only.

Proprietary Notice
This document, including the information contained herein, is confidential and/ or proprietary to CAE Inc., and shall not be reproduced or disclosed in whole or in part, or used for any purpose whatsoever without the prior written authorization of CAE Inc.

Trademark Information
Trademarks and/or registered trademarks of CAE Healthcare Inc. and/or its affiliates include but are not limited to: Apollo, Ares, AresAR, Aria, Athena, BabySIM, BluePhantom, Caesar, CathLabVR, EndoVR, HPS, ICCU, lnfantSIM, iStan, Juno, LapVR, LearningSpace, Lucina, LucinaAR, Luna, Maestro, METlman, Muse, NeuroVR, PediaSIM, SimEquip, Simulex, StethoSym, SymDefib, SymEyes, UniSIM, Vimedix, VimedixAR and Vivo. All other brands and product names are trademarks or registered trademarks of their respective owners. All logos, tradenames and trademarks referred to and used herein remain the property of their respective owners and may not be used, changed, copied, altered, or quoted without the written consent of the respective owner. All rights reserved.

Cautions and Warnings

Read this user guide, including all cautions and warnings, before you use your CAE Blue Phantom™ ultrasound training model. Use this product only as described in this guide. If you use the product incorrectly, it may be unsafe and will void your warranty. Keep this information for future reference.

General Precautions
  • Make sure the training model is set up on a stable, sturdy work surface such as a bed, stretcher, or table that will not collapse and cause injury to users.
  • Heavier training models should be placed on a patient bed or stretcher rated to support such weight.
  • Place the model on smooth surfaces only. Rough or uneven surfaces can leave impressions on the skin and damage the model.
  • Do only the procedures supported by each product as described in this guide.
  • Do not use needles. This model is not designed for punctures or other needle access. Using needles can cause injury and will void the warranty.
  • Do not use or store other sharp objects such as scissors, scalpels, or box-cutters with the training model.
  • Do not pull on the training model skin. This can cause the skin to tear.
  • Do not mark directly on the training model as this will permanently damage it.
  • Do not insert any objects or tools into the model except for the equipment, accessories, or medical supplies intended for use with this model.
  • Do not use chemical solvents on the models.
  • Clean the training model with water and a light soap solution only. Do not immerse the model or use large amounts of liquid to wash it.

Latex-Free

  • All CAE Blue Phantom training models, products, and accessories are manufactured only of materials that do not contain latex.
Service and Repair
  • The CAE Blue Phantom training models are not user-serviceable. Only a trained technician may open or disassemble the product.
  • Unauthorized use or handling of the model may void the warranty.
  • If you have a problem with your product, contact CAE Customer Support.

Introduction

This user guide describes the features, use, and care of the following training models:

  • CAE Blue Phantom Bone Fracture Ultrasound Training Block, crepitus (BPBF200-C)
  • CAE Blue Phantom Bone Fracture Ultrasound Training Block, greenstick (BPBF200-G)
  • CAE Blue Phantom Branched 4-Vessel Ultrasound Training Block (BPBV110)
  • CAE Blue Phantom Branched 2-Vessel Ultrasound Training Block (BPO100)
  • CAE Blue Phantom Pediatric 4-Vessel Ultrasound Training Block (BPP120)
  • CAE Blue Phantom Regional Anesthesia Ultrasound Training Block (BPNB150)
  • CAE Blue Phantom Soft Tissue Biopsy Ultrasound Training Block (BPTM130)
  • CAE Blue Phantom Foreign Body Identification Ultrasound Training Block (BPFB-140)

These models are intended as platforms for the practice of ultrasound examination and various ultrasound-guided procedures. Each model is presented as a CAE Blue Phantom Signature Blue Block™.

GTSimulators-com-BPBF200-Bone-Fracture-Ultrasound-Training-
fig-1

Anatomy

CAE Blue Phantom training models are constructed using our patented Simulex™ ultrasound tissue which has imaging characteristics that mimic human tissue.

The models have use-specific anatomy or features:

  • Bone Fracture Ultrasound Training Block, crepitus (BPBF200-C)
    • Crepitus bone fracture
  • Bone Fracture Ultrasound TrainingBlock, greenstick (BPBF200-G)
    • Greenstick bone fracture
  • Branched 4 Vessel Ultrasound Training Block (BPBV110)
    • Two 4mm vessels, one each 6mm and 8mm vessel
  • Branched 2 Vessel Ultrasound Training Block (BPO100)
    • One 6mm vessels, one 4mm vessel
  • Pediatric 4 Vessel Ultrasound Training Block (BPP120)
    • Two 6mm vessels, two 2mm vessel
  • Regional Anesthesia Ultrasound Training Block (BPNB150)
    • Three 5mm nerves, one 6mm vessel that bifurcates into three vessels
  • Soft Tissue Biopsy Ultrasound Training Block (BPTM130)
    • 16 masses of varying size and echogenicity
  • Foreign Body Identification Ultrasound Training Block (BPFB-140)
    • Metal projectile BBs
    • Metal shrapnel fragments
    • Wooden splinters
    • Metal needles
    • Large glass fragments
    • Glass shards
Equipment Overview

The following items are included with your shipment:

  • Ultrasound training model
  • Plastic storage case

The following additional items are required for training but not included in your purchase:

  • Ultrasound system with appropriate transducer
  • Ultrasound gel
  • Procedure equipment per local protocol

CAE Blue Phantom training models are compatible with any diagnostic ultrasound system. General frequency ranges for diagnostic ultrasound imaging are 2-20MHz.

Using the Training Model

This section has information and instructions about the setup and use of the training model and any specific training procedures.

Setup

Follow the guidelines below to unpack and set up your CAE Blue Phantom training model.

  1. Open the shipping carton:
    • Use extreme caution with sharp tools, such as a box cutter, to avoid damage to the training model.
  2. Unpack the equipment:
    • Remove the training model from its shipping container. For heavier models, use proper lifting techniques to prevent bodily injury.
    • Review the equipment, accessories, and supplies to make sure all necessary pieces are present. See the Equipment Overview section of this guide for a list of items included with this model.
  3. Set up for training:
    • Put the model on a stable patient bed, stretcher, or table.
    • Prepare your ultrasound system and equipment.
    • Gather any procedural equipment and supplies.
Training

This section provides information about using your model for training and practice.

Ultrasound Scanning

Note:
CAE Blue Phantom products do not teach ultrasound procedures or techniques. Refer to your institution or training program for more information.

To scan with your training model and conduct a simulated ultrasound-guided procedure:

  1. Place the model in the appropriate position for scanning.
  2. Place ultrasound gel on the transducer or on the training model in an adequate quantity so that the transducer slides effortlessly on the model. Add more gel as needed.
  3. Adjust the ultrasound system controls per your training protocol and the manufacturer’s instructions. Optimize the image with the ultrasound controls as needed.

Ultrasound-guided Procedures
In addition to ultrasound scanning, some block models are designed for specific ultrasound-guided needle procedures. For the two models listed below, use your normal protocol and equipment for the procedures, and follow your institution’s policies and guidelines.

CAUTION
Do not use antiseptics, such as iodine, on the training model. This can cause permanent damage to the model.

Follow these procedure-specific guidelines for your model:

CAE Blue Phantom Regional Anesthesia Ultrasound Training Block (BPNB150)
For optimal performance of the training model, follow these steps:

  1. Purge all air from the needle before infusing simulated anesthetics into the model.
    NOTE: Accidental infusion of air into the model during training can cause air to remain within the tissue or needle track. The Simulex tissue then will not “heal” and this will result in a visible needle track or air bubble. Remove the trapped air by injecting the same access point with fluid until the air is flushed from the system.

  2. Inject the fluid. As you inject the simulated anesthetic, you will observe the accumulation of fluid at the needle tip location.
    NOTE: Do not inject tap water into your training model. Infuse only local anesthetics, saline, sterile water, or CAE Blue Phantom fluid.

  3. After the injection procedure is completed, remove the fluid from the model by drawing back the syringe plunger to withdraw the infused fluid.

CAE Blue Phantom Soft Tissue Biopsy Ultrasound Training Block (BPTM130)
When a tissue sample is taken from the block, it leaves an air-filled space the same size as the sample. Once a tissue sample is removed, it cannot be re- inserted. Therefore, this product has a finite lifespan.

Care and Maintenance

With proper care, your training model will remain in optimal condition and ready for use.

Storage and Transport

Follow these guidelines to properly store or transport your model:

  • Storage temperature degree range: 45 to 85 °F (7 to 29 °C)
  • Store the model in its plastic storage case.
  • Ensure any tubes are not pinched or compressed under the block. This will damage the tubes and void the warranty.
  • Transport the block in its plastic storage case.
Cleaning

To maintain the product skin for the lifespan of the product, clean the exterior of the model after each use. Follow these steps:

  1. Mix one cup of tap water with ¼ teaspoon of mild liquid soap (such as dish soap).
  2. Gently clean the model’s exterior with the soap mixture and a soft, non-abrasive sponge or cloth.
  3. Rinse lightly with clean water.
  4. Dab or pat with a clean, soft, lint-free cloth to dry the product after cleaning. Do not wipe or rub the skin, which can damage it.
  5. After the model has dried completely, lightly coat the external surface of the model with baby powder and dust off any excess.
Help and Technical Assistance

For assistance, contact CAE Customer Support. Contact information for all regions is available on the back cover of this guide and on the CAE Healthcare website.

For more information about CAE products, contact your regional sales manager or the CAE distributor in your country, or visit caehealthcare.com.

For customer support, please contact CAE.

Customer Support -Canada

Customer Support – Europe, Middle East, and Africa

Customer Support – United Kingdom and Ireland

Customer Support – Latin America

  • Monday – Friday from 9:00 a.m. to 5:00 p.m. BRT/BRST
  • Phone +55 11 5069-1510
  • Email: la.service@cae.com.

Customer Support – Asia Pacific

  • Monday – Friday from 8:00 a.m. to 5:00 p.m. CET
  • Phone +49 (0) 6131 4950354
  • Email: ap.service@cae.com.

©2022CAE.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals