DIGILENT PmodPMON1 Power Monitor
Product Information
PmodPMON1TM
The PmodPMON1TM is a monitoring module designed by Digilent, Inc. It allows users to monitor current draw and voltages for various devices. The module offers the following features:
- Monitor current draw less than 1.058 A
- Wide range of configurable alert conditions
- Monitor voltages from 3.16 V to 26 V
- Configurable device address for up to nine devices
Product Usage Instructions
Using Multiple PmodPMON1s
In order to use multiple PmodPMON1s on a single I2C bus, follow these steps:
- Connect each individual PmodPMON1 to the I2C bus.
- Program the desired potentiometer value into the EEPROM on the AD5112 for each PmodPMON1. This value will become the default starting value for the potentiometer.
- Note that the alert functionality on the ADM1191 will not work properly without programming each individual device.
- Refer to Table 2 for jumper descriptions related to device configuration.
Device Configuration
For specific information related to device configuration on the AD5112 and ADM1191, please refer to the data sheets available at www.analog.com.
Connector Descriptions
Pin | Signal | Description |
---|---|---|
1,2 | CONV | Trigger a conversion |
3,4 | Overcurrent or overvoltage ALERT event | |
1,2 | SCL | Serial Clock |
3,4 | SDA | Serial Data |
5,6 | GND | Ground |
7,8 | DVDD | Input Voltage |
1 | VIN | Input voltage of device to be monitored |
2 | GND | Ground |
3 | VOUT | Voltage supplied to device being monitored |
Jumper Descriptions
Jumper | Setting | Description |
---|---|---|
JP1 | 1 3 OFF | ADM1191 Address bit 3 and 2 set to 0b00 |
JP2 | 1 3 OFF | ADM1191 Address bit 3 and 2 set to 0b01 |
ADM1191 Address bit 3 and 2 set to 0b10 | ||
ADM1191 Address bit 1 and 0 set to 0b00 | ||
ADM1191 Address bit 1 and 0 set to 0b01 | ||
ADM1191 Address bit 1 and 0 set to 0b10 |
This product manual is copyrighted by Digilent, Inc. All rights reserved. Other product and company names mentioned may be trademarks of their respective owners.
Overview
The PmodPMON1 employs the Analog Devices® AD5112 and ADM1191 to create a system power monitor.
Features include:
- Monitor current draw less than 1.058 A
- Wide range of configurable alert conditions
- Monitor voltages from 3.16 V to 26 V
- Configurable device address for up to nine modules in a single system
- Small PCB size for flexible designs 1.2“ × 0.8” (2.8 cm × 2.0 cm)
- 2×4-pin connector with I2C interface
- Follows Digilent Pmod Interface Specification
Functional Description
Customers can configure the PMON1 to a wide range of possible alert conditions from the ADM1191 by using the configurable AD5112 potentiometer. The AD5112 upper potentiometer connection ties to DVDD through a filtering ferrite bead and the lower connection connects to GND. (See Table 1 for Connector Descriptions.) The wiper directly connects to the SETV pin on the ADM1191 to allow for the wide range of alert conditions. If an alert condition occurs, LD1 on the PMON1 will illuminate and the alert pin will go to a logic low state.
Using Multiple PmodPMON1s
In order to use multiple PMON1’s on a single I2C bus, each individual PMON1 will need to be connected; and the desired potentiometer value programmed into the EEPROM on the AD5112. Any stored value will become the default starting value for the potentiometer. The alert functionality available on the ADM1191 will not functionproperly without programming each individual device. (See Table 2 for jumper descriptions.)
Device Configuration
For specific information related to device configuration on the AD5112 and ADM1191, please refer to the data sheets available at www.analog.com
Connector J1 – Control Pins
Pin| Signal| Description
1,2| CONV| Trigger a conversion
3,4|
ALERT
| Overcurrent or overvoltage
event
Connector J2 – I2C Interface
1,2| SCL| Serial Clock
3,4| SDA| Serial Data
5,6| GND| Ground
7,8| DVDD| Input Voltage
Connector J3 – Power Monitor Screw Terminal
1| VIN| Input voltage of device to
monitored
2| GND| Ground
3| VOUT| Voltage supplied to device
being monitored
Table 1. Connector descriptions.
Jumper | Setting | Description |
---|
__
__
JP1
| 1| ADM1191 Address bit 3 and 2 set to 0b00
3| ADM1191 Address bit 3
and 2 set to 0b01
OFF| ADM1191 Address bit 3
and 2 set to 0b10
__
__
JP2
| 1| ADM1191 Address bit 1 and 0 set to 0b00
3| ADM1191 Address bit 1
and 0 set to 0b01
OFF| ADM1191 Address bit 1
and 0 set to 0b10
Table 2. Jumper descriptions.
Copyright Digilent, Inc. All rights reserved.
Other product and company names mentioned may be trademarks of their
respective owners.
Downloaded from Arrow.com.
1300 Henley Court
Pullman, WA 99163
509.334.6306
www.digilentinc.com