tp-link TL-SG2218P Jetstream Smart Switch Installation Guide

June 12, 2024
tp-link

tp-link TL-SG2218P Jetstream Smart Switch Installation Guide
Smart Switch

Introduction

Product Overview
Designed for workgroups and departments, TP-Link JetStream Smart Switch provides wire-speed performance and abundant L2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB and CLI Login bring abundant management policies. TP- Link JetStream SmartSwitch integrates multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. TL-SG2210MP/TL-SG2218P/TL- SG2428P/TL-SL2428P/TL-SG728P is also a Power Sourcing Equipment (PSE). Some of the RJ45 ports on the switch support Power over Ethernet (PoE) function, which can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af and IEEE 802.3at.
*PSE:* a device (switch or hub for instance) that provides power through an Ethernet cable.
PoE:* a technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. PD: a device powered by a PSE and thus consumes energy. Examples include powering network cameras, wireless LAN access points, IP telephones, network hubs, embedded computers etc.

Appearance
Front Panel
The front panel of TL-SG2218 is shown as the following figure.
Instruction

The front panel of TL-SG2210MP is shown as the following figure.

Instruction

The front panel of TL-SG2218P is shown as the following figure.
Instruction

The front panel of TL-SG2428P is shown as the following figure.
Instruction

The front panel of TL-SL2428P is shown as the following figure.
Instruction

The front panel of TL-SG728P is shown as the following figure.

Instruction

LEDs For TL-SG2218

LED Indication
PWR O n : The switch is powered on. O f f : The switch

is powered off or power supply is abnormal. F l a s hin g : Power supply is abnormal.
SYS| F l a s hin g : The switch works properly. O n o r O f f : The switch works improperly.
Link/Act| O n : A device is connected to the corresponding port but no activity. F l a s hin g : Data is being transmitted or received. O f f : No device is connected to the corresponding port.
1000Mbps| O n : Running at 1000 Mbps. O f f : Running at 10/100 Mbps or no device is linked to the corresponding port.
PWR| On: The switch is powered on. Off: The switch is powered off or power supply is abnormal. Flashing: Power supply is abnormal.
SYS| Flashing: The switch works properly. On or Off: The switch works improperly.
FAN| Green: All the fans work properly. Yellow: Not all the fans work properly.
PoE Max| On: The remaining PoE power is 7 W. Flashing: The remaining PoE power keeps 7 W after this LED is on for 2 minutes. Off: The remaining PoE power is > 7 W.
10/100M or PoE(When the Speed LED is on)| Green On: Running at 100 Mbps, but no activity. Green Flashing: Running at 100 Mbps and is transmitting or receiving data. Yellow On: Running at 10 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps and is transmitting or receiving data. Off: No device is linked to the corresponding port. Note: Only for TL- SL2428P.
1000MSpeed or PoE(When the Speed LED is on)| Green On: Running at 1000 Mbps, but no activity. Green Flashing: Running at 1000 Mbps and is transmitting or receiving data. Yellow On: Running at 10/100 Mbps, but no activity. Yellow Flashing: Running at 10/100 Mbps and is transmitting or receiving data. Off: No device is linked to the corresponding port. Note: 1000M for TL-SL2428P. Speed or PoE for TL-SG2210MP, port 1 16 of TL- SG2218P, port 1 24 of TL-SG2428P and TL-SG728P
10/100M or PoE Speed or PoE(When the PoE LED is on)| Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Yellow Flashing: Power-on self-test failed. Off: Not providing PoE power on the port. Note: 10/100M or PoE for TL-SL2428P. Speed or PoE for TL-SG2210MP, port 1 16 of TL-SG2218P, port 1 24 of TL-SG2428P and TL-SG728P

Speed1000Base-X SFP1, SFP2

| Green On: A 1000 Mbps device is linked to the corresponding port, but no activity. Green Flashing: A 1000 Mbps device is linked to the corresponding port and data is being transmitted or received. Yellow On: A 10/100 Mbps device is linked to the corresponding port, but no activity. Yellow Flashing: A 10/100 Mbps device is linked to the corresponding port and is transmitting or receiving data. Off: No device is linked to the corresponding port. Note: 1000Base-X for port 25 28 of TL-SG2428P and TL-SG728P. Speed for TL- SG2218P. SFP1/SFP2 for TL-SG2210MP.

LED Mode Switch Button
Press this button to switch the LED status indication between Speed and PoE.

Reset
With the switch powered on, press Reset button for 5 seconds to reset the switch to its factory default settings.

10/100 Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10 Mbps or 100 Mbps.
10/100/1000 Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps or 1000 Mbps.
SFP Slot
Designed to install the SFP module.

Port Feature

Model| 100M/1000 M/10GbpsRJ45 Port| 10/100/1000 Mbps RJ45 Port| 10/100 Mbps RJ45Port| SFP Slot| SFP+ Slot
---|---|---|---|---|---
TL-SG2218| /| 16| /| 2| /
TL-SG2210MP| /| 8| /| 2| /
TL-SG2218P| /| 16| /| 2| /
TL-SG2428P| /| 24| /| 4| /
TL-SL2428P| /| 4| 24| 2| /
TL-SG728P| /| 24| /| 4| /

Rear Panel
The rear panel is shown as the following figure. The actual product may differ from the figure.
Instruction

Kensington Security Slot
Secure the lock (not provided) into the security slot to prevent the device from being stolen.

Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, go to https://www .tp-link.com/support, search the model number of your switch and go to the product Support web page, refer to the Lightning Protection Guide from the Related Documents:
https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/.

Power Socket
Connect the female connector of the power cord here, and the male connector to the AC power outlet. Make sure that the voltage of the power supply meets the requirement of the input voltage (100–240 V~ 50/60 Hz).

Caution:
You should use the provided power cord.

Installation

Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor.

  • One Switch

  • One Power Cord

  • Installation Guide

  • Two mounting brackets, eight screws and four rubber feet

Safety Precautions
To avoid any device damage and bodily injury caused by improper use, you should observe the following rules.

Safety Precautions

  • Keep the power off during the installation.
  • Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded.
  • Use only the power cord provided with the switch.
  • Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch.
  • Ensure that the switch is installed in a well-ventilated environment and its ventilation hole is not blocked.
  • Do not open or remove the cover of the switch.
  • Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning method.
  • Place the device with its bottom surface downward.

Site Requirements
Temperature/Humidity
Temperature

Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the following table.

Environment Temperature Humidity
Operating 0 °C to 50 °C(for TL-SG2210MP/TL-SG2218P/TL-SG2428P/TL- SL2428P/TL-
SG728P)0 °C to 40 °C (for other switches) 10% to 90%RH Non-condensing
Storage -40 °C to 70 °C 5% to 90%RH Non-condensing

Clearness
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the switch, attach much importance to the following items:

  • Dust the device regularly, and keep the indoor air clean.
  • Keep the device well grounded and ensure that the static electricity has been transferred.

Electromagnetic Interference
Electromagnetic

Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, make sure to take the following measures:

  • Use the power supply that can effectively filter interference from the power grid.
  • Keep the device far from high-frequency and strong-current devices such as radio transmitting station.
  • Use electromagnetic shielding when necessary

Lightning Protection
Lightning Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000 °C. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.

  • Ensure that the rack and the device are well earthed.
  • Make sure the power socket has a good contact with the ground.
  • Keep a reasonable cabling system and avoid induced lightning.
  • Use the signal SPD (Surge Protective Device) when wiring outdoor

Note: For detailed lightning protection measures, go to https://www.tp- link.com/support, search the model number of your switch and go to the product Support web page, refer to the Lightning Protection Guide from the Related Documents:
https://www.tp-link.com/us/configuration-guides/lightning_protection_guide/.

Installation Site
Installation Site

When installing the device on a rack or a flat workbench, attach much importance to the following items:

  • The rack or workbench is flat, stable, and sturdy enough to support the weight of 5.5 kg at least.
  • The rack or workbench has a good ventilation system. The equipment room is well ventilated.
  • The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.

Installation Tools

  • Phillips screwdriver
  • ESD-preventive wrist wrap
  • Cables

Note:
These tools are not included with our product. If needed, you can purchase them separately.

Product Installation
Desktop Installation
To install the device on the desktop, follow the steps:

  1. Set the device on a flat surface which is strong enough to support the entire weight of the device with all fittings.
  2. Remove the adhesive backing papers from the rubber feet.
  3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at each corner of the device.

Desktop Installation

Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below:

  1. Check the efficiency of the grounding system and the stability of the rack.

  2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as illustrated in the following figure.
    Bracket Installation

  3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure.
    Rack Installation

Caution:

  • Leave 5 to 10 cm gaps around the devices for air circulation.
  • Avoid placing heavy things on the device.
  • Place the device with its bottom facing downwards.
  • Mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.

Connection

Ethernet Port
Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows.
Connecting Port

SFP Slot
The following figure demonstrates the connection of SFP module to an SFP slot.
Inserting SFP Module

Verify Installation
After completing the installation, verify the following items:

  • There should be 5 to 10 cm of clearance around the device for ventilation and make sure the air flow is adequate.
  • The voltage of the power supply meets the requirement of the input voltage of the device.
  • The power socket, device and rack are well grounded.
  • The device is correctly connected to other network devices.

Power On
Plug the negative connector of the provided power cord into the power socket of the device and plug the positive connector into a power outlet as the following figure shows.
Connecting Power Supply

Note:
The figure is to illustrate the application and principle. The provided plug and the socket in your region may differ from the figures above.

Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically to ensure the device functions properly. During this time, its LED indicators will respond in the following order:

  1. The PWR LED indicator lights on all the time. The SYS LED and the LED indicators of all the ports keep off.
  2. (For TL-SG2210MP/TL-SG2218P/TL-SG2428P/TL-SL2428P/TL-SG728P) After about one minute, all LED indicators will turn green, and then the FAN indicator and LED indicators of all the ports will turn yellow momentarily. Subsequently, all LED indicators except the PWR LED will turn off. (For other switches) After about one minute, the SYS LED and LED indicators of all the ports will flash momentarily and then turn off.
  3. Several seconds later, the SYS LED indicator will flash, which represents a successful initialization.

Configuration

Configuration Overview
The switch supports two configuration options:

  • Standalone Mode: Configure and manage the switch singly.
  • Controller Mode: Configure and manage the network devices centrally. It is recommended in the large-scale network, which consists of mass devices such as access points, switches, and gateways.

Note:
TL-SG2428P, TL-SL2428P, TL-SG2210MP, TL-SG2218P and TL-SG2218 suppor t both Standalone Mode and Controller Mode. When the switch is changed from Standalone Mode to Controller Mode, you should reconfigure the switch. TL- SG728P only supports Standalone Mode.

Standalone Mode
In Standalone Mode, use a computer to configure and manage the switch.
Topology Standalone Mode

Using the GUI

  1. To access the management page of the switch, make sure the switch and computer are in the same subnet. Open a browser and type the switch’s IP address in the address field, then press the Enter key.
    • If the switch obtains IP address from the DHCP server (typically a router), find the switch’s IP address on the DHCP server.
    • If not, use the default IP address 192.168.0.1 to launch the switch’s management page.
  2. Enter admin for both the username and password in the lower case letters to log in. The first timeyou log in, change the password to better protect your network and devices.
  3. After a successful login, the main page will appear. You can click the menus on the top side and left side to configure the corresponding functions.

For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/support/download/.

  • Using the CLI
  • Set up a Telnet or SSH connection to access the switch via CLI (command-line interface).

For the detailed configurations, refer to the User Guide and CLI Guide. The guides can be found on the download center of our official website: https://www.tp-link.com/download-center.html

Note:
For certain devices, you may need to change the password the first time you log in, which will better protect your network and devices.

Controller Mode
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Hardware Controller or Omada Software Controller.

Note:
Before the following configurations, make sure the switch can access the internet. When using Omada Software/Hardware Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Hardware Controller (OC200/OC300)
Omada Hardware Controller (OC200/OC300) is a good alternative if you have no spare PC to keep running Omada Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Hardware Controller.
Manage Hardware Controller

Note:

  • Before you start, be sure to power up and connect your devices according to the topology figure.
  • A DHCP server (typically a router with DHCP function enabled) is required to assign IP addresses to the EAPs and clients in your local network.
  • Omada Controller must have network access to your Omada devices (the router, switch, or EAPs) in order to find, adopt, and manage them.
  1. Find the IP address of the router. Open the command line on your PC and enter ipconfig. In the result list, find the Default Gateway, which is also the IP address of the router.
  2. Launch a web browser and enter the IP address of the router. Log into the router’s web page, and both the username and password are admin by default. Then go to Network > LAN > DHCP Client List to find the IP address of your controller according to its MAC address.
  3. Enter the IP address of the your controller in the address bar to open its web page.
  4. On the Omada Controller’s web page, follow the wizard to complete the quick setup.
  5. After the quick setup, the login page appears. Enter the username and password you have created and click Log in. Then you can further configure the controller.
  6. If you want to manage the devices reomotely, follow the next steps:
    a. Make sure that Cloud Access is enabled on your controller. By default, Cloud Access is enabled. Make sure that the Cloud LED is flashing slowly
    b. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Enter yourTP-Link ID and password to log in. Click + Add Controller and choose Hardware Controller to add your controller. Then you can further configure the controller.
    For more details, refer to the Installation Guide of OC200/OC300.

Via Omada Software Controller
On a PC with Windows OS or Linux OS, download the Omada Software Controller from
https://www.tp-link.com/support/download/omada-software-controller/. Then run the file and follow the wizard to install the Omada Software Controller. Follow the steps below to configure the Controller.
Manage Software Controller

Note : To manage your devices, Omada Software Controller needs to keep running on your computer.

  1. Launch the Omada Software Controller on your PC. After the initiation process, the controller automatically opens its web page. If not, click Launch a Browser to Manage the Network.
  2. On the Omada Controller’s web page, follow the wizard to complete the quick setup.
  3. After the quick setup, the login page appears. Enter the username and password you have created and click Log in. Then you can further configure the controller.
  4. If you want to manage the devices reomotely, follow the next steps:
    a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Controller’s web page, go to Settings > Cloud Access to enable Cloud Access and bind your TP- Link ID. If you have set it up in the quick setup, skip this step.
    b. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Enter your TP-Link ID and password to log in. A list of controllers that have been bound with your TP-Link ID will appear. Then you can click Launch to further configure the controller.

Omada App
With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device.

For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official website: https://www.tp-link.com/support/download/.

Appendix A Troubleshooting

What could I do if I forgot the username and password of the switch?

Press the Reset button for at least 5 seconds to reset the system. The system will be reset to the factory default settings, and the default login user name and password are both admin.

Why does the PWR/Power LED work abnormally?

The PWR/Power LED should be lit up when the power system works normally. If the PWR LED worked abnormally, try the following: 1. Make sure that the power cable is connected properly, and the power contact is normal. 2. Make sure the voltage of the power supply meets the requirement of the input voltage of the switch.

What should I do if I cannot access the web management page?

Appendix B Specifications

Item Content
Standards IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ad, IEEE 802.3z,

IEEE 802.3x, IEEE 802.1p, IEEE 802.1q, IEEE 802.1x, IEEE 802.1d, IEEE 802.1s, IEEE 802.1w
IEEE 802.3af, IEEE 802.3at (For TL-SG2210MP/TL-SG2218P/TL-SG2428P/TLSL2428P /TL-SG728P)
Transmission Medium| 10Base-T: UTP/STP of Cat. 3 or above
100Base-TX: UTP/STP of Cat. 5 or above
100Base-FX/LX10/BX10: MMF or SMF SFP Module (For TL-SG2210MP/TLSG2428P/TL- SG728P)
1000Base-T: 4-pair UTP (≤ 100 m) of Cat. 5e, and Cat. 6 or above
1000Base-SX/LX/LX10/BX10: MMF or SMF SFP Module
LEDs| TL-SL2428P: PWR, SYS, PoE MAX, FAN, 10/100M or PoE, 1000M, 10/100M, PoE TL-SG2210MP: PWR, SYS, PoE MAX, FAN, Speed or PoE, SFP1, SFP2, PoE, Speed TL- SG2218P: PWR, SYS, PoE MAX, FAN, PoE, Speed TL-SG2218: PWR, SYS, 1000Mbps, Link/Act TL-SG2428P/TL-SG728P: PWR, SYS, FAN, PoE MAX, Speed, PoE, 100BaseTX/1000BASE-X
Operating Temperature| 0 °C to 50 °C (32 °F to 122 °F) (For TL-SG2210MP/TL- SG2218P/TL-SG2428P/TLSL2428P/TL-SG728P) 0 °C to 40 °C (32 °F to 104 °F) (For other switches)
Storage Temperature| -40 °C to 70 °C (-40 °F to 158 °F)
Operating Humidity| 10% to 90%RH Non-condensing
Storage Humidity| 5% to 90%RH Non-condensing

CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.

EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC, 2011/65/EU and  (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp- link.com/en/support/ce/

UK declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016.

The original UK declaration of conformity may be found at https://www.tp- link.com/support/ukca/

Safety Information

  • Keep the device away from water, fire, humidity or hot environments.
  • Do not attempt to disassemble, repair, or modify the device. If you need service, please contactus.
  • Place the device with its bottom surface downward.
  • The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily accessible.

Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.

To ask questions, find answers, and communicate with TP-Link users or engineers, please visit https://community.tp-link.com to join TP-Link Community.

For technical support, the user guide and other information, please visit https://www.tp-link.com/support, or simply scan the QR code.
QR Code

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals