macnaught BOP20 BOP Battery Operated Pump Instruction Manual
- June 12, 2024
- macnaught
Table of Contents
BOP20 BOP Battery Operated Pump
Product Information
The Macnaught BOP battery operated pump is a high-quality pump
designed for use with automotive oils and lubricants. It is
manufactured using premium quality materials and workmanship to
ensure durability and reliability.
Please note that this product should only be used with
non-flammable automotive oil/lubricants with viscosity grades from
0W-40 to SAE85W-140. Usage with different fluids may cause
performance degradation and void the warranty. The use of flammable
fluids can lead to sparks, explosion, and fire hazards. Macnaught
bears no liability for the consequences of fluid misuse by
customers.
General Safety
- DO NOT operate power tools in explosive areas, such as close to
flammable liquids, gases, or dust.
Electrical Safety
-
Never modify electrical connections.
-
DO NOT expose the power tool to rain or wet conditions.
-
DO NOT use the product if it is damaged or if the switch does
not turn the pump on. -
Only use ORIGINAL Macnaught replacement parts, battery, or
charger.
Battery and Charger Safety
-
Please follow the instructions from the battery and charger
owner’s manual. -
If the battery-pack case is damaged, DO NOT use it as there is
a danger of electric shock or electrocution. -
The battery charger MUST ONLY be used for charging the
rechargeable batteries supplied with the BOP. -
DO NOT operate the charger if it, the power cord, or plug is
damaged – replace immediately.
Product Usage Instructions
-
Visually inspect the pump, charger, and battery prior to use
for any signs of damage, loose or missing parts. If any equipment
is worn or damaged, remove it from service and replace if
required. -
Ensure all operators have adequate access to the following
instructions. -
Use the product in a well-ventilated area and avoid using it in
potentially explosive atmospheres. -
Wear appropriate personal protective equipment (PPE) for
protection. -
Refer to the Material Safety Data Sheet (MSDS) of the fluid
being used from the supplier. -
Always ensure the switch is in the off position after
dispensing the oil. -
Use the pump in adequate lighting conditions for safe operation
and avoid using it under poor illumination. -
Avoid spillage of oil near water sources as it may be harmful
to the environment. -
When moving the drum, check the area for spillage and clean up
any liquid on the floor as it may cause a slippery surface.
&
Instruction Manual
BP-inst-issue15 Instruction Manual
Page 1
INTRODUCTION
Thank you for purchasing the Macnaught BOP battery operated pump.
Macnaught has designed and manufactured this pump to the highest quality
standards using premium quality materials and workmanship.
PLEASE READ THIS SAFETY INFORMATION CAREFULLY BEFORE USE. Read and retain this
instruction manual to assist you in the operation of your new product.
WARNING
Please read this important information carefully before use. This product
should only be used with automotive oils and lubricants.
Visually inspect pump, charger and battery prior to use for any signs of
damage, loose or missing parts. If equipment is worn or damaged, remove it
from service (Replace if required).
The BOP Battery operated pump must be used strictly in accordance with
Macnaught’s terms and conditions.
`WARNING’ listed throughout this manual to advise of actions which may cause
damage to your equipment.
Failure to follow all instructions listed below may result in electric shock,
fire, serious injury and/or damage to the power tool. The term “power tool” in
all of the warnings listed refers to your battery operated (cordless) power
tool.
Make sure all operators have adequate access to the following instructions.
GENERAL SAFETY
DO NOT operate power tools in explosive areas, e.g; close to flammable
liquids, gases or dust.
ELECTRICAL SAFETY
Never modify electrical connections. DO NOT expose power tool to rain or wet
conditions. DO NOT use product if the product is damaged or the switch does
not turn the pump on.
Only use “ORIGINAL” Macnaught replacement parts, battery or charger.
BATTERY and CHARGER SAFETY
Please follow instructions from battery and charger owners manual
If “battery-pack” case is damaged DO NOT use – Danger of electric shock or electrocution. Battery charger MUST ONLY be used for charging the rechargeable batteries supplied with the BOP. DO NOT operate charger if charger, power cord or plug is damaged – replace immediately.
DO NOT disassemble charger or battery. DO NOT store battery pack in locations where the temperature may reach or exceed 40°C/104°F. DO NOT use charger on any other voltage than designated on the charger.
Instruction Manual
Page 2
DISCLAIMER Your product is designed to use with non-flammable automotive
oil/lubricants only, with viscosity grades from 0W-40 to SAE85W-140. Usage
with different fluids may cause performance degradation and render the
warranty void. Improper use of liquid may lead to machine failure and
malfunction.
Use of any flammable fluids can cause sparks to explode and create a fire
hazard. Macnaught bears no liability to the consequence of fluid misuse by
customers.
WARNING
Always place gun on hanger when pump is not in use, as oil spillage can cause
a slipping hazard. Keep plastic bag away from babies and children. Do not lift
the power head with locking lever. Handle power head with care. DO NOT DROP.
Make sure the power head is securely connected/attached to the stem. Do not
leave the power head sitting on top of the stem unlocked. Stop operating the
battery oil pump if any leakings at the joints are noticed. Do not modify the
pump in any way. Only use a genuine Macnaught dispensing gun. Hand tighten the
hose till its firm and check for any signs of
leakage before use.
Do not use flammable fluid in this product. Only use fluid specified in this
instruction manual. Wear appropriate PPE for protection. Do not use the
product in potentially explosive atmosphere. Do not expose the product to fire
and source of heat. Users should refer to MSDS of the fluid from supplier
being used. Use product in well ventilated area. Never leave your dispensing
gun unattended in open position. Do not attempt to use any means to lock the
lever. Always ensure the switch is in off position after dispensing the oil.
Use pump in adequate lighting condition for safe operation. Do not use the
product under poor illumination. Avoid spillage of oil near water source as it
may be harmful to the environment. When moving drum, check area for spillage
and clean up any liquid on floor as this will cause a slippery
hazard Only use genuine Macnaught battery and chargers with this product.
Battery pack, charger and power head should be protected from water.
CAUTION
- Do not expose the power head to a nearby magnet as its performance will be adversely affected.
The battery operated pump should always be used in a vertical position.
The dispensing gun should always be facing up when dispensing fluid.
If the noise level changes check the hose to see if there is air present, if air is present stop the pump immediately as this indicates the drum is empty. Switch over to a new drum.
Instruction Manual
Page 3
BATTERY DISPOSAL
NOTE: Dispose of old batteries properly. The battery contains rechargeable Lithium-ion and must be recycled or disposed of properly. Please refer to the local authorities for the correct method of battery disposal.
DO NOT incinerate the battery pack. The battery can explode in a fire
DO NOT attempt to disassemble any battery.
CHARGE BATTERY
-
Insert battery
-
Power on (green light only)
-
Battery charging (red light only)
-
Battery charged (green light only)
Note: Red light flashes when battery voltage is low (trickle charging to prevent battery damage)
INSERT / REMOVE BATTERY
- Insert battery
a) lift handle
a)
b) push down
b)
Instruction Manual
- Remove battery a) lift handle b) press button c) pull up
c)
a) b)
Page 4
ASSEMBLY
Note: For models supplied with a
flow meter, refer to meter assembly instructions on page13
-
Remove both the inlet and outlet plugs from the pump stem before use.
-
Pull down extender tube
-
Push the pump stem into container
-
Tighten bung adapter to secure pump stem
-
Attach hose and gun (ensure end gasket is in place)
-
Ensure switch is off, then place power head onto pump stem
-
Press handle down to lock power head
Note: Power head will not oprerate unless locked correctly into position.
-
Place gun onto hanger when finished
Note: If nozzle holder is fitted, place nozzle into holder when finished. -
To remove power head, lift handle.
Instruction Manual
Page 5
OPERATING INSTRUCTIONS OPERATION
CAUTION NOTE: Do not allow the pump to run dry or pump damage can occur
IMPORTANT: For initial operation
- Turn slot in shaft clockwise one complete turn with a flat head screwdriver.
- First press the trigger on gun and then turn on the pump to prime.
- Release trigger when primed (fluid flows from gun). 4) Power head can be moved from pump assembly to pump assembly.
- Long storage periods : a) Turn slot shaft 2 full turns counter clockwise
using a flat head screwdriver. b) When starting pump after a long storage
period, turn slot shaft clockwise with a flat head screwdriver.
Note: Pump will not run when power head is not attached to pump stem correctly.
Pressure sensor will turn motor off when trigger is released and stall pressure is reached.
For low viscosity oils you may need to manually prime the system before use
Note: There may be a delay in the pump turning off when the trigger on the gun is released, this is normal as the pump is priming to stall pressure.
GENERAL OPERATION 1) Attach power head to stem
CAUTION 2) Remove nozzle cover before use
1
- Press or Release trigger to adjust flow
- Lift handle to transfer power head from stem to stem
4 3
NOTE Remove nozzle cover before use Replace nozzle cover after use
Instruction Manual
Page 6
DIAPHRAGM AND SPRING REPLACEMENT
-
Turn anti-clockwise, remove drive gear
-
Remove 3 screws, pump cover and dispensing gun hanger
-
Remove 2 screws.
-
Remove assembly.
-
Remove circlip.
-
Replace spring.
-
Re-fit circlip.
-
Remove old diaphragm.
-
Fit new diaphragm. (ensure correct orientation)
-
Fit valve switch assembly.
-
Fit 2 screws.
-
Fit pump cover and dispensing gun hanger, using 3 screws.
-
Fit drive gear, turn clockwise to secure.
Instruction Manual
Page 7
IMPELLER AND O’RING REPLACEMENT
-
Unscrew adapter
-
Remove o’ring.
-
To assist in the removal of the impeller carefully use a small flat edged screwdriver in the small groove
-
Remove o’ring.
-
Carefully remove and replace impeller.
-
Replace o’ring.
Note: Impeller must be lubricated with oil or grease during assembly.
-
Carefully insert impeller housing. (Note correct orientation of grooves)
-
Replace o’ring.
-
Firmly hand tighten pump tube.
Instruction Manual
Page 8
EXPLODED DIAGRAM
Note: Power head is factory sealed and would need to be replaced if found to
be damaged internally or externally.
Spare parts list
Item no
Pump Kit Ref (A)
BP-1K
No off
Description Pump Seal Kit
1
1 Nut (M6)
2
1 Connector
3
3 Screws (3.5 x 25)
4
1 Pump Stem Top Cover
5
1 Hook – Dispensing Gun
6
1 Ball Bearing
7
1 Housing – Pump Stem
8
1 Roller Bearing
9
1 Oil Seal
10
1 Drive Shaft
11
A
1 Cover Impeller Chamber
12
A
1 Flexible Impeller
13
A
1 O’Ring
14
A
1 Housing – Impeller Chamber
15
A
1 O’Ring
16
1 Spring
17
1 Check Valve
18
A
1 O.Ring
19
1 Nut – Pump Stem
20
1 Drain Back Adaptor
21
1 Bung adapter (type C)
22
1 Tube Cover
23
1 Outer Tube
24
1 Base
25
A
2 Magnet
26
A
1 Circlip E-Clip
27
2 Screw – 3.5×16
28
1 Housing – Pressure Switch
29
A
1 Spring
30
A
1 Plunger
31
A
1 Diaphragm
32
1 U-Clip
33
A
1 O.Ring
34
1 Connector
35
1 Dust Cover
Bung Adapter for 20ltr drum with pull out spout – order BP037s
Instruction Manual
Page 9
TROUBLESHOOTING GUIDE
TROUBLE Pump does not turn on
Pump will not prime
Power head does not stop when gun trigger is released
CAUSE a) Flat battery
b) Power head not attached correctly to pump
c) Faulty switch
d) Pump stem failure
REMEDY a) Recharge battery b) Re-fit power head correctly
c) Contact supplier d) Contact supplier
a) Pump tube plug has not
a) Remove tube plug
been removed before use.
b) Damaged or worn impeller b) Fit new impeller
Note: Do not let the impeller run dry
c) No oil in container d) Damaged gun or hose e) Damaged diaphragm
c) Check oil level in container d) Replace gun e) Replace diaphragm
a) Damaged diaphragm or spring
a) Replace damaged diaphragm or spring
b) Damaged or worn impeller b) Replace impeller
c) Gun leaking
c) Replace gun
d) Damaged hose
d) Replace hose
Instruction Manual
Page 10
PUMP SPECIFICATIONS
Flowrate – Low to Medium Viscosity Oil Flowrate – High Viscosity Oil Flowrate
– ATF Flowrate – Coolant Operating Temperature Container Size Fluid
compatibility Max Viscosity Self Priming Shut off Pressure Hose Warranty –
Pump and Power Head Warranty – Battery
Wetted components
Relative humidity Hook Colour
-
3.5 l/min (0W-40 @ 20 deg C)
-
2 l/min (85W-140 @ 20 deg C) 4.5 l/min (ATF @ 20 deg C 5.8 l/min @ 20 deg C 0°C – 40°C (32°F – 104°F)
Models available to suit 20ltr and 60ltr containers Automotive oils / Lubricants / ATF / Coolant up to SAE 85W-140 Yes
20psi 19mm x 1.5m (5ft) wire reinforced PVC
2 Years
12 Months Nitrile rubber, Mild steel, Stainless steel, Aluminium, Nylon, Brass, Pol-
ypropylene, Zinc plated steel
50% – 90% Black -
Flowrates are a guide only and any variations can depend on temperatture and fluid viscosity
Instruction Manual
Page 11
Available Kits and Packs
BP20S-UNA BP20S-UNB BP20S-UNE BP20S-UNJ BP20S-UNU
BP20X-UNA BP20S-UNE BP20S-UNJ
BOP SEAL KIT BP-1K
BOP Universal Starter Kits
20L
BOP20 UN STARTER KIT AU BOP20 UN STARTER KIT UK BOP20 UN STARTER KIT EU BOP20
UN STARTER KIT JP BOP20 UN STARTER KIT US
BP60S-UNA BP60S-UNB BP60S-UNE BP60S-UNJ BP60S-UNU
60L
BOP60 UN STARTER KIT AU BOP60 UN STARTER KIT UK BOP60 UN STARTER KIT EU BOP20
UN STARTER KIT JP BOP20 UN STARTER KIT US
BOP Universal Stem Kits
20L BOP20 UN STEM KIT AU BOP20 UN STEM KIT EU/UK BOP20 UN STEM KIT JP
BP60S-UNA
60L BOP60 UN STEM KIT AU
Pump Stem Lengths 20ltr – 297mm (extended 395mm) 60ltr – 520mm (extended
618mm)
Instruction Manual
Page 12
IM012EB-01 ELECTRONIC METER
INSTRUCTION MANUAL
This meter is designed specifically for the Macnaught BOP Battery Operated Pump Series
Instruction Manual
Page 13
INTRODUCTION
PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE.
Read and retain this instruction manual to assist you in the operation of this
product.
If you have any problems with the meter, refer to the maintenance and trouble
shooting sections of this manual.
If you need further assistance, please contact your local representative or
distributor for advice.
This Flow Meter has incorporated the oval rotor principal into its design.
This has proven to be a reliable and accurate method of measuring flow.
Exceptional repeatability is the feature of the oval rotor design.
CAUTION
- Macnaught recommends the use of PPE equipment such as safety glasses, protective gloves, safety shoes etc before handling or using this product.
- Do not modify or alter this product any way
- Ensure that any fluid spillage is cleaned up immediately to prevent slipping or injury.
- Firmly tighten all connections and check for any sign of leakage before use.
IMPORTANT INFORMATION
WARNING
This product should only be used with automotive oils and lubricants
OPERATING PRINCIPAL
When fluid passes through the meter the rotors turn, as shown below. The magnets which are located in the rotors will pass across the PCB sensors. A signal is generated which is then sent by the PCB to the LCD as a Pulse Output.
METER TO GUN ASSEMBLY
- Prior to assembling connector (2) to the gun (1) remove item (5) from the gun (1).
- Screw item (2) to the gun outlet (1) – Do not over tighten.
- Slide O’ring (6) all the way onto screw (2)
6 2 3 4) Remove theU’clip (3) from the meter (4) 5) Insert the meter inlet (4) onto the connector (2) apply light pressure to the meter, this will slightly compress the O’ring (6) then firmly press in the
U’ clip until flush with the body (3) as shown 6) Carefully screw the outlet tube (5) onto the meter outlet (4) – Do not over tigthen
4 6
5 2
3
1
Instruction Manual
Page 14
LITRE
US GAL
US QT
RESET BATCH TOTAL
NON RESET TOTAL
SELECT UNITS
INLET
OPERATING INSTRUCTIONS
The display wakens when flluid passes through the meter or either the “M”or
“L”button is pressed. Note: The display will go to sleep after 3 seconds if
no flow is detected
BACK LIGHT To turn on the backlight press “L” button
Change Units Setting
- Waken display by pressing either the `M”or “L” button
- Press and hold down the “L” button until the arrow moves to the next unit setting a) Press and hold down button to change from L to US-GAL b) Press and hold down button to change from US-GAL to US-Qt c) Press and hold down button to change from US-Qt to L
BACK LIGHT
RESET ACCUMULATIVE TOTAL
Reset batch or accumulative totals to zero
- Waken display by pressing either the `M”or “L” Button
- Press and release “M” button to move arrow to desired batch (A) or total (B) setting
- Simultaneously press and release the “M”and “L”buttons to reset the numbers
to zero.
REPLACE BATTERY - Carefully pull open the battery drawer as shown 2) Carefully slide the old
battery from the PCB 3) Carefully insert the new CR2450 Lithium Coin
battery.
Note: Ensure the battery is fitted with the + on the battery pointing up as shown below. - Slide the battery drawer shut firmly to ensure the O’ring seals the drawer opening correctly,
Change Batch and Total Setting
- Waken display by pressing either the `M”or “L” button
- Press and release “M” button to move arrow to desired batch or total
setting A = Resettable batch total B = Resettable accumulative total C = Non
ressettable accumulative total
Instruction Manual
- Page 15
METER TROUBLE SHOOTING
TROUBLE Meter not reading
No display
Meter not accurate
CAUSE a) Damaged or faulty PCB b) Damaged or jammed rotors a) Flat battery b)
Damaged or faulty PCB a) Air in the oil b) Leakage
c) Flowrate too high
REMEDY a) Replace meter b) Replace meter a) Replace battery (Lithium CR2450) b) Replace meter a) Ensure the system is fully primed and air free b) Check and ensure all connections are properly assembled and sealed, otherwise replace meter as required. c) See specification for maximum flowrate
METER SPECIFICATIONS
FLOW RATE OPERATING TEMPERATURE OPERATING PRESSURE ACCURACY IP RATING INLET CONNECTION OUTLET CONNECTION POWER
Up to 10LPM -20 deg C to +70 deg C 20psi (Max 60psi) +/- 2% of reading IP65 ½”inlet connector supplied 1/2″BSPP (F) 1 x CR2450 – 3V Lithium Coin Ba ery
Instruction Manual
Page 16
WEEE Directive – Waste Electrical and Electronic Equipment
The WEEE Directive requires the recycling of waste electrical and electronic
equipment in the European Union.
Whilst the WEEE Directive does not apply to some of Macnaught’s products, we
support its policy and ask you to be aware of how to dispose of this product.
The crossed out wheelie bin symbol illustrated and found on our products
signifies that this product should not be disposed of in general waste or
landfill.
Please contact your local dealer national distributor or Macnaught Technical
Services for information on product disposal.
Instruction Manual
Page 17
WEEE Directive – Waste Electrical and Electronic Equipment
Instruction Manual
The WEEE Directive requires the recycling of waste electrical and electronic
equipment in the European Union.
Whilst the WEEE Directive does not apply to some of Macnaught’s products, we
support its policy and ask you to be aware of how to dispose of this product.
The crossed out wheelie bin symbol illustrated and found on our products
signifies that this product should not be disposed of in general waste or
landfill.
Please contact your local dealer national distributor or Macnaught Technical
Services for information on product disposal.
Page 18
FCC:
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–
Reorient or relocate the receiving antenna.
–
Increase the separation between the equipment and receiver.
–
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
–
Consult the dealer or an experienced radio/ TV technician for help.
Instruction Manual
Page 19
Instruction Manual
Page 20
Instruction Manual
Page 21
NOTES:
Instruction Manual
Page 22
NOTES:
Instruction Manual
Page 23
Note: This product should be disposed of according to all applicable local and
national government environment regulations and guidelines.
For Warranty Terms and Conditions see macnaught.com.au For a list of
Australian Service Centres see macnaught.com.au
Instruction Manual
Page 24
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>