arietta Dekor Glass Island 400 CFM Island Range Hood Installation Guide

June 12, 2024
arietta

Installation Instructions Guide
arietta Dekor Glass Island 400 CFM Island Range Hood READ AND SAVE THESE INSTRUCTIONS
LIB0178806

APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical
Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel before wiring this appliance.
Requirement 120 VAC, 60 Hz. 15 or 20 A Branch Circuit

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

  • Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.

  • Installation work and electrical wiring must be done by qualifi ed person(s) in accordance with all applicable codes and standards, including fi re-rated construction.

  • Suffi cient air is needed for proper combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

  • When cutting or drilling into wall or ceiling; do not damage electrical wiring and other hidden utilities.

  • Ducted fans must always be vented outdoors.
    CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
    CAUTION: To reduce risk of fi re and to properly exhaust air, be sure to duct air outside – do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces, or garages.
    WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK
    WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  • Never leave surface units unattended at high settings.
    Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

  • Always turn hood ON when cooking at high heat or when  flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

  • Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter.

  • Use proper pan size. Always use cookware appropriate for the size of the surface element.
    WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:

  • SMOTHER FLAMES with a close fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the fl ames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

  • NEVER PICK UP A FLAMING PAN – you may get burned.

  • DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

  • Use an extinguisher ONLY if:
    -You know you have a class ABC extinguisher, and you already know how to operate it.
    – The fi re is small and contained in the area where it started.
    – The fi re department is being called.
    – You can fi ght the fi re with your back to an exit.
    Based on “Kitchen Fire Safety Tips” published by NFPA.
    WARNING: To reduce the risk of fi re or electrical shock, do not use this fan with any solid-state speed control device.
    WARNING: Do not operate any fan with a damaged cord or plug.
    Discard fan or return to an authorized service facility for examination and/or repair.

READ AND SAVE THESE INSTRUCTIONS

Tools and Parts

Parts supplied
Removing the packaging
CAUTION!
Remove carton carefully, wear gloves to protect against sharp edges.
WARNING!
Remove the protective film covering the product before putting into operation.

Part Qty
Hood assembly with blower and LED lamps already installed 1
5×45 mm 4
4.2×8 mm 62
3.5×9.5 mm 2
3.5×6.5 mm 4
2.9×3 mm 2
Leveling screws 2
8×40 mm 4
Horizontal supports 2
Lower and upper duct covers Upper: 2

Lower: 2
6” round air transition| 1
Duct cover brackets| 4
Vertical supports| Upper: 4
Lower: 4
Torx adapter| #10: 1

20: 1

Mounting template| 1

Parts not supplied

Tools/Materials required

  • Wire nuts

  • Tape to mount template

  • 6” (15.2 cm) rounded metal duct length to suit installation

  • Measuring tape

  • Pliers

  • Gloves

  • Knife

  • Safety glasses

  • Electric drill with 5 ⁄16 ” and 3⁄8 ” bits

  • Strain relief

  • Spirit level

  • Duct tape

  • Screwdrivers:
    – Phillips (Posidrive) #2
    – Flat blade

  • Wire cutter/stripper

  • Masking tape

  • Hammer

  • Saw, jig saw or reciprocating saw

Parts needed

  • Home power supply cable
  •  ½” (12.7 mm) UL listed or CSA approved strain relief
  • 3 UL listed wire connectors

For vented installations, you will also need:

  • 1 wall or roof cap
  •  Metal vent system

Optional Accessories

KIT # Part
Recirculating Kit KIT01938
Long Chimney Extension Kit KIT0100317
Backdraft damper 6″ Kit KIT0102873
CFM reduction Kit KIT02748

Dimensions and Clearances

| ADI436SSB
---|---
A| 36” (91.44 cm)
B| 251⁄4 ” (64 cm)
C*| Max: 4913⁄32 ” (125.3 cm)
Min: 2913⁄32 ” (74.5 cm)
D**| Max: 4421⁄64 ” (112.4 cm)
Min: 2913⁄32 ” (74.5 cm)
E| 6” (15.24 cm)
F| 12” (30.5 cm)
G| 13 5 ⁄64 ” (33.2 cm)

  • Ductless (Recirculating) version
    ** Ducted version

Electrical Requirements

IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:

  • To contact a qualified electrical installer.
  • To assure that the electrical installation is adequate and inconformance with National Electrical Code, ANSI/ NFPA 70— latest edition*, or CSA Standards C22.1-94,  CanadianElectrical Code, Part 1 and C22.2 No.0-M91 – latest edition** and all local codes and ordinances.
  • If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
  • Do not ground to a gas pipe.
  • Check with a qualified electrician if you are not sure range hood is properly grounded.
  • Do not have a fuse in the neutral or ground circuit.
    A copy of the above code standards can be obtained from: National Fire Protection Association
    1 Batterymarch Park
    Quincy, MA 02169-7471
    CSA International
    8501 East Pleasant Valley Road
    Cleveland, OH 44131-5575

IMPORTANT

  • Save Installation Instructions for electrical inspector’s use.
  • The range hood must be connected with copper wire only.
  • The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.
  • Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 – latest edition** and all local codes and ordinances.
  • A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).

BEFORE INSTALLING THE HOOD

  1. For the most efficient air flow exhaust, use a straight run or as few elbows as possible.
    CAUTION:Vent unit to outside of building, only.

  2.  At least two people are necessary for installation.

  3.  Fittings material is provided to secure the hood to most types of walls/ceilings, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.

  4.  Do not use flex ducting.

  5. COLD WEATHER installations should have an additional back draft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be
    on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house.

  6.  Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Ducting Options

Closely follow the instructions set out in this manual.
All responsability, for any eventual inconveniences, damages  or fires caused by not complying with the instructions in thismanual, is declined.
Ducting version
The hood is equipped with a 6” (15.2 cm) round transition for discharge of fumes to the outside.

Ductless (Recirculating)
In cases where it should not be possible to discharge cooking fumes and vapour to the outside.
Attach a charcoal filter and the deflector on the duct cover support bracket. Fumes and vapours are recycled through the top grille by means of a duct connected to the transition and the transition mounted on the deflector. See accesories section.

Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.
Fittings material is provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Recommended installation height:
Hood installation height above cooktop is the users preference.
The lower the hood is above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.
CAUTION
For gas cooktop & range installations: Mount the hood so the bottom is at least 30” (76.2 cm) above the cooking surface.
For electric/induction cooktop & range installations: Mount the hood so the bottom is at least 24” (61 cm) above the cooking surface.
There is no maximum mounting height, however, we recommend mounting the hood no greater than 36” (91.4 cm) above the cooking surface. For every inch (2.54 cm) above 36” (91.4 cm), fume and moisture capture efficiency diminishes at an increasing rate and may not deliver an acceptable level of ventilating performance.
This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC APPLICATION. Check your ceiling height and hood height before selecting your hood.

Installation instructions

Ceiling support structures

  • This vent hood is heavy. Adequate structure and support must be provided in all types of installations.
  • At the hood location, install 2”x 4” cross framing between ceiling joists as shown. (2”x 4” are required to support the weight of the hood.)
  • Arrange cross framing in the ceiling to suit the existing structure.
  • Your ceiling joists will be like one of the following:

Example A

Example B

Example C

Install Range Hood

  1. Place the template in the ceiling considering the instructions for ceiling support structures.
    NOTE: Always consider the front of hood legend when placing the template on the ceiling. It will define the control’s location.

  2. Mark with a pencil the hole locations for screws and duct in the ceiling.

  3. Remove template

  4. Fix the upper horizontal support with 4 – 5×45 mm screws.

  5. Install the 6” (15.2 cm) round transition with 2 – 3.5×9.5 mm screws.

  6. Fix the lower horizontal support with lower vertical supports with 8 – 4.2×8 mm screws.

  7. Install the 4 vertical supports with 16 – 4.2×8 mm screws.arietta Dekor Glass Island 400 CFM Island Range Hood - Install

  8. Install the structure to the horizontal support with 16 – 4.2×8 mm screws.arietta Dekor Glass Island 400 CFM Island Range Hood - structure

  9. Using 2 or more people, lift the range hood assembly under the structure.arietta Dekor Glass Island 400 CFM Island Range Hood - structurce

  10. Attach the range hood assembly to the lower vertical supports with 2 leveling screws.arietta Dekor Glass Island 400 CFM Island Range Hood - vertical

  11. Install the 4 vertical supports with 16 – 4.2×8 mm screws. Check everything is tightly screwed.

Electrical Connection

WARNING
ELECTRICAL SHOCK HAZARD.
WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.

  1. Disconnect power.

  2. Remove terminal box cover.

  3.  Remove the knockout in the terminal box cover and install a UL listed or CSA approved 1⁄2 ” strain relief.

  4. Run home power supply cable through strain relief, into terminal box.

  5. Remove the 2 leveling screws from the structure.arietta Dekor Glass Island 400 CFM Island Range Hood - Leveling

  6. Use UL listed wire connectors and connect black wires (C) together.

  7. Use UL listed wire connectors and connect white wires (E) together.
    WARNING
    ELECTRICAL SHOCK HAZARD.
    WARNING
    ELECTRICALLY GROUND BLOWER.
    CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.

  8.  Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors.

  9. Tighten strain relief screw.

  10. Install terminal box cover.

  11.  Reconnect power.

Complete Installation

ONLY FOR RECIRCULATING VERSION
(Using Recirculating Kit model KIT02665)
Air deflector installation

  • Assemble the air deflector with the upper horizontal support with 2 assembly screws.arietta Dekor Glass Island 400 CFM Island Range Hood - deflector
  • Measure from the bottom of the air deflector to the bottom of the hood outlet, as shown.arietta Dekor Glass Island 400 CFM Island Range Hood - measure
  • Cut the duct at the measured size.
  • Slip the duct onto the bottom of the deflector.
  • Place the duct over the exhaust outlet from the hood.
  • Use duct tape to seal the deflector and at the exhaust outlet from the hood.
  • The charcoal filters needs to be clipped on the motor as the image below shown.

Duct cover installation (both ducted and non ducted versions)

  • Attach the upper duct covers using 6 – 3.5×6.5 mm screws.
    NOTE: For non-ducted (recirculating) installation, the slotted holes in the upper duct covers will be visible when assembled. For ducted installations, the slotted holes will be hidden down inside the lower duct covers.arietta Dekor Glass Island 400 CFM Island Range Hood -
covers2

  • Place lower duct covers using one plastic bracket at each side (4 needed).

  • Secure the lower duct cover to the range hood canopy using 4 – 4.2 x 8 mm screws.arietta Dekor Glass Island 400 CFM Island Range Hood - screws

Description of the Hood

arietta Dekor Glass Island 400 CFM Island Range Hood -
lights

Control

arietta Dekor Glass Island 400 CFM Island Range Hood -
button

  1. Light On/Off button
  2. Blower On/Off button
  3. Blower speed minimum button
  4. Blower speed medium button
  5.  Blower speed maximum button

Range Hood Care

ATTENTION!
Before performing any maintenance operation, isolate the hood from the electrical supply by switching off at the connector and removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.
Cleaning
Do not spray cleaners directly to the control while cleaning the Hood.The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products.
DO NOT USE ALCOHOL!
Exterior surfaces:
To avoid damage to the exterior surface, do not use steel wool or soap-filled scouring pads. Do not use chlorine base cleaners.
Rub in direction of the grain line to avoid scratching the surface.
WARNING
Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
Grease filter
Traps cooking grease particles.
This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle.

Operating the blower
The Blower On/Off button (2) turns the blower On or Off.
The Blower Speed buttons (3, 4 and 5) set the desired speed and control the sound level for quiet operation. The speed can be changed anytime during fan operation by pressing the desired blower speed button.

  1. To turn the blower On, press the Blower On/Off button (2) and the desired speed button (3, 4 or 5).
  2. To turn the blower Off, press the Blower On/Off button (2).
    Any of the 3 blower speed buttons can be in the On position at the same time. The blower will operate at the highest speed button that is pushed in. For lower blower speeds, the higher speed buttons must not be pushed in.

Replacing a LED Lamp
The LED lights are replaceable by a service technician only. See “Who to contact” section in the warranty for service contact information.
Charcoal filter
WARNING
When used in recirculation mode, To Reduce the Risk of Fire and Shock use only conversion kit Models:
Recirculating kit: KIT02665
Charcoal filter replacement: KIT02667
If the model is not vented to the outside, the air will be recirculated through disposable charcoal filters that help remove smoke and odors.

  1. Cover the grill that protects the suction motor with the carbon filter so that the slots on the filter correspond to the pins on the sides of the motor protection grill.
  2. Turn the carbon filter clockwise to block them (bayonet fixing).
    NOTE: The charcoal filters cannot be cleaned. It should be replaced every 4-6 months (depending on hood usage).
    NOTE: DO NOT rinse, or put charcoal filters in an automatic dishwasher.
    NOTE: Charcoal filters are not included with the hood. They must be ordered from your supplier. Order the needed kit specifying your hood model and width size.

Are You Having Difficulty Assembling This Product? Missing Parts?
PLEASE DO NOT RETURN TO THE STORE!
Call Service Power 1-888-732-8018 between 7 a.m. and 4:00 p.m. (Pacific Time),
Monday – Friday or
Email: elica@servicepower.com
(please include contact name, model, serial number, purchasing ticket and best time to contact) for all replacement parts and any questions you may have about this product!
sERvicFpower Service Made Simple 1503 South Coast Drive #320 Costa Mesa, CA 92626 IMPORTANT: Please save the original package if return is needed.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals