plentisolar – Solplanet ASW1000S-S Inverter Installation Guide

June 12, 2024
plentisolar - Solplanet

plentisolar logo plentisolar - Solplanet ASW1000S-S Inverter -
logoQuick installation guideplentisolar - Solplanet
ASW1000S-S Inverter ASW1000S-S/ASW1500S-S
ASW2000S-S/ASW3000S-S

Safety Instruction

  1. The contents of this document will be updated irregularly for product version up- grade or other reasons. Unless otherwise specified, this document only works as guide. All statements, information and suggestions in this document do not constitute any guarantee.
  2. This product can only be installed, commissioned, operated and maintained by technicians who have carefully read and fully understood the user manual.
  3. This product must only be connected with PV modules of protection class II(in accordance with IEC 61730, application class A).PV modules witha high capacitance to ground must only be used if their capacity does not exceed 1yF.Do not connect any sources of energy other than PV modules to the product.
  4. When exposed to sunlight, the PV modules generate dangerous high DC voltage which is present in the DC cable conductors and live components. Touching live DC cable conductors and live components can result in lethal injuries due to electric shock.
  5. All components must remain within their permitted operating ranges at all times.
  6. The product complies with Electromagnetic compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and Radio Equipment Directive 2014/53/EU.

Mounting environment

  1. Ensure that the inverter is installed out of the reach of children.

  2. To ensure best operating status and prolonged service life, the mounting. ambient temperature of the inverter should be <40°C.

  3. To avoid direct sunlight, rain, snow, ponding on the inverter, it is suggested to mount the inverter in places with a top protective roof. Do not completely cover the top of the inverter.

  4. The mounting condition must be suitable for the weight and size of the inverter. The inverter is suitable to be mounted on solid wall that is vertical or tilted backwards (Max. 15°). Itis not recommended to install the inverter on wall made of plaster- boards or similar materials. The inverter may make noise when working.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
2

  5. To ensure adequate heat dissipation, the clearances between . the inverter and other objects are recommended as follows:plentisolar - Solplanet ASW1000S-S Inverter - Mounting 3

Scope of delivery

plentisolar - Solplanet ASW1000S-S Inverter - Mounting
4

Inverter’s mounting

  1. Use a 610mm bit to drill 3 holes at adepth of about 70mm according to the location  of the wall mounting bracket.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
5

  2. Insert wall plugs into the wall and fix the wall mounting bracket to the wall by  screwing three self-tapping screws(SW10).
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
6

  3. Hang the inverter to the wall mounting bracket.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
7

  4. Secure the inverter to the wall mounting bracket using M4 screw. Screwdriver type: PH2, torque: 1.6Nm
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
8

AC connection

DANGER

  • Allelectrical installations must be done in accordance with all local and national rules.
  • Make sure that all OC switches and AC circuit breakers have been discon- nected before establishing electrical connection. Otherwise, the high voltage within the inverter may lead to electrical shock.
  • In accordance with safety regulations, the inverter need be grounded firmly. When poor ground connection(PE) occurs, the inverter will report PE grounding error. Please check and ensure that the inverter is grounded firmly or contact AISWEI service.
  1. AC cable requirements are as follows. Insert the conductor into a suitable ferrule acc. to DIN 46228-4 and crimp the contact.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
9
Object Explanation
M4 xl0screw Screwdriver type: PH2, torque: 1.6Nm
OT terminal lug Customer provided, type: M4
Grounding cable Copper conductor cross-section: 2.5-6mm2
  1. Loosen the swivel nut of AC connector. Insert the crimped conductors into corre- sponding terminals and tighten screws with the accompanied Allen key. Torque: 2.0Nm
  2. plentisolar - Solplanet ASW1000S-S Inverter - Mounting 10Insert the adapter to the socket element, stuff the seal ring into the adapter and tighten the swivel nut.plentisolar - Solplanet ASW1000S-S Inverter - Mounting 11
  3. Plug the AC connector into the socket for the AC connection.plentisolar - Solplanet ASW1000S-S Inverter - Mounting 12
  4. If required, you can connect a second protective conductor as equipotential bonding.
Object Explanation
M4 xl0screw Screwdriver type: PH2, torque: 1.6Nm
OT terminal lug Customer provided, type: M4
Grounding cable Copper conductor cross-section: 2.5-6mm2

DC connection

DANGER

  • Make sure PV modules have good insulation against ground.
  • On the coldest day based on statistical records, the Max. open-circuit voltage of the PV modules must not exceed the Max. input voltage of the inverter.
  • Check the polarity of DC cables.
  • Ensure that DC switch has been disconnected.
  • Do not disconnect DC connectors under load.
  1. Please refer to “DC Connector Installation Guide”.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
14

  2. Before DC connection, insert the DC plug connectors with sealing plugs into DC input connectors of the inverter to ensure protection degree.

Communication setup

  • Separate communication cables from power cables and serious interference  sources.

  • The communication cables must be CAT-5E or higher-level shield cables. Pin assignment complies with ElIA/TIA 568B standard. For outdoor use, the com- munication cables must be UV-resistant. The total length of communication cable cannot exceed 1000m.

  • If only one communication cable is connected, insert a sealing plug into the unused hole of sealing ring of the cable gland.

  • Before connecting communication cables, ensure the protective film or communication plate attached to the communication opening on the inver- ter is sealed tightly.

    1. COM1: RS485(optional)

    2. RS485 cable pin assignment as below.
      plentisolar - Solplanet ASW1000S-S Inverter - Mounting
15Pin 1=TX_RS485A
      Pin 2=TX_RS485B
      Pin 3=NC
      Pin 4=GND
      Pin S5=GND
      Pin 6=NC
      Pin 7=+7V
      Pin 8=+7V

    3. Loosen the swivel nut of the cable gland onthe communication cover, remove sealing plugs and lead the cable through the swivel nut, sealing ring, communica- tion cover and magnetic ring.plentisolar - Solplanet ASW1000S-S Inverter - Mounting 16

    4. Insert the cable into the socket, attach the communication cover to inverter with M4 screws , and tighten the swivel nut. Screwdriver type: PH2, torque: 1.6Nm
      plentisolar - Solplanet ASW1000S-S Inverter - Mounting
17

    5. COM2: GPRS/WiFi plentisolar - Solplanet ASW1000S-S Inverter - Mounting 18
      PIN| PIN1| PIN2| PIN3| PIN4
      ---|---|---|---|---
      Assignment| VCC| GND| RS485A| RS48513

**** The connection refers to “GPRS/WiFi-stick User Manual”.

  1. Smart meter

  2. Remove the communication plate from the inverter.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
19

  3. Loosen the swivel nut of the cable gland on the communication plate, remove the sealing plug and lead the stripped cable through the cable gland and communi-cation plate, press the latch of the smart meter terminal and insert the stripped cable accordingly. Make sure the cable is connected firmly.
    plentisolar - Solplanet ASW1000S-S Inverter - Mounting
20

  4. Insert the smart meter terminal to the socket, attach communication plate to the inverter with M4 screws, and tighten the swivel nut.
    Screwdriver type: PH2, torque: 1.6Nmplentisolar - Solplanet ASW1000S-S
Inverter - Mounting 21

  5. If communication cover used, remove only one sealing plug of the cable gland to thread the cable. Detailed installation process follows above steps.

Com missioning

DANGER

  • Check that the inverter is grounded reliably.
  • Check that the ventilation condition surrounding the inverter is good.
  • Check that the grid voltage at the point of connection of the inverter is within the permitted range.
  • Check that the sealing plugs in DC connectors and the communication cable gland are sealed tightly.
  • Check that grid connection regulations and other parameter settings meet safety requirements.
  1. Switch on AC circuit breaker between the inverter and the grid.
  2. Switch on OC switch.
  3. When there is sufficient OC power applied and the grid conditions are met, the inverter will start to operate automatically.

EU Declaration of Conformity

**** Within the scope of the EU directives:
– Electromagnetic compatibility 2014/30/EU (L96/79-106 , March 29, 2014)(EMC)
– Low voltage directive 2014/35/EU (L 96/357-374 , March 29, 2014)(LVD)
– Radio equipment directive 2014/53/EU (L 153/62-106 , May 22, 2014)(RED)
AISWEI New Energy Technology (Jiangsu) Co., Ltd. confirms herewith that the inverters mentioned in this document are in compliance with the fundamental requirements and other relevant provisions of the above mentioned directives.
The entire EU Declaration of Conformity can be found at www.aiswei- tech.com.

Technical Data

Technical Data| ASW1000S-S| ASW1500S-S| ASW2000S-S| ASW3000S-S
---|---|---|---|---
DC Input|
Max. PV modules power(STC)| 1500W| I 2250W| I 3000W| I 4500W
Max. DC input voltage| 580V
MPP voltage range| 80-550V
Max. DC input current| 12A
Max. DC input short current| 18A
Max. DC input current, per MPPT| 12A
Number of MPPT/strings per MPPT| 1/1
AC Output|
Rated active power| 1000W| 1500W| 2000W| 3000W
Max. apparent power| 1000VA| 1500VA| 2000VA| 3000VA
Rated grid voltage| 220/230V
Rated grid frequency| 50/60Hz
Max. AC output current| 5A| I 7.5A| I 10A| I 13.6A
Adjustable displacement power factor| 0.8 ind. .0.8 cap
Harmonic distortion (THD) at Pac.r| <3%
General Data|
Dimensions (W x H x D)| 320x 264 x94mm
Weight| 6.5kg
Noise emission (typical)| < 25dB(A)@lm
DC connection| Plug-in DC connector
AC connection| Plug-in AC connector
Communication| GPRS/WiFi , RS485(Optional)
Display| LED
Mounting| Wall mounting
Cooling| Convection
Operating temperature range| -25…+60°C
Relative humidity (non-condensing)| 0…100%
Max. operating altitude| 4000mIDerating above 3000m)
Degree of protection| IP65
Climate Category| 4K4H
Topology| Transformerless

plentisolar logoScan QR code:
http://www.aisweicloud.com/data/download.jsp
Monitoring APPplentisolar - Solplanet ASW1000S-S Inverter -
logoplentisolar - Solplanet ASW1000S-S Inverter -
qr codehttps://www.plentisolar.de/
P/N: 540-30115-03
Date: 2020-12-16

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>