JCWear 2208A Smart Health Bracelet User Manual
- June 12, 2024
- JCWear
Table of Contents
2208A Smart Health Bracelet
User Manual
Product Introduction
2208A is a smart health bracelet which can monitor multiple body vital signs all the day and night.
24/7 Heart Rate Monitor| Sp02| Skin Temperature
HRV| Stress| Multi-sport Tracking
Sleep Tracking| Activity Tracking| Waterproof IP68
Note: The 2208A is not a medical device and is not intended to diagnose or monitor any disease or medical condition.
What’s Included in the Box
- Smart bracelet
- Magnetic USB charger
- User manual
Instruction
-
Download the APP
• Scan the OR code below or search JCWear on Google Play or iOS App Store to download our JCWear App.
• Make sure the Bluetooth of your mobile device is on.
• Choose device identified in App and connect to your 2208A smart bracelet. JCWear
https://qr06.cn/CZuyPV
Note: Please ensure that your Android version is 5.0 or later, OS version is 10.0 or later. The 2208A supports Bluetooth 5.0 connection. -
Charge Before Use
• Please fully charge the device to activate for first use.
• If after factory reset on the App, please charge to power on.
Simply place your device on the magnetic USB charger, and plug it into a wall outlet or USB 2.0+ port to begin charging. The indicator light flashes red, blue and green alternately during charging, and the green light is always on when fully charged. After removing the device from the charger, the indicator lights up green for 2 seconds and then goes off. Power Indicator
Short press the home button to wake up the device, the indicator lights up in different colors to indicate different power levels, as follows:
• Red light for 1 second, indicating that the current power is 0%-24%;
• Blue light for 1 second, indicating that the current power is 25%-49%; Green light for 1 second, indicating that the current power is 50%-100%.
When the power is lower than 5%, Bluetooth will be disconnected, please charge in time. It typically takes about 1.5 hours to fully charge, supports about 7-10 days for normal use and about 20 days for standby. Battery life changes depending on the activated features, type and frequency of device use.
Note: Please prevent the USB charger port from coming into contact with conductive materials, such as liquids, dust, metal powders and pencil leads. -
App & Function Operation
Once the device is activated, please pair it with the “JCWear” App for operation and use. It will light up white for 2 seconds when Bluetooth is connected, and then light up in different colors to indicate different power levels.
Home
View your detailed health data and report per day: steps, distance, calories, heart rate, Sp02, blood pressure, HRV, stress, skin temperature, sleep, women’s health, exercise, etc. You can make menstrual cycle management on App if required. It’s convenient to make both manual and automatic health vital signs measurement on the device or App.
Manual Health Vital Signs Measurement
-
Sp02
There are 2 manual Sp02 measurement methods in standby mode:
(1) turn on/off the measurement directly on App.
(2) short press home button twice to start measurement.
During the measurement, the blue light will flash; if your hand moves, the blue light will flash quickly to remind you to keep still; after the measurement is finished, the green light will be on for 2 seconds if the result is normal, and the red light will be on for 2 seconds if it is abnormal.
Note: if you press the button once during the measurement, it will return to the standby mode and end the measurement. -
Blood Pressure/HRV/Stress
Make manual blood pressure/HRV/stress measurement through App only. During the measurement, the blue light will flash; if your hand moves, the blue light will flash quickly to remind you to keep still; the blue light will be on for 2 seconds after the measurement is finished. -
Skin Temperature
Make manual skin temperature measurement through App only.
After starting measurement, the device vibrates once, while the blue light will flash until it vibrates 3 times and the blue light will be on for 2 seconds, indicating the end of measurement.
Device
Check current device’s basic information (battery level, MAC ID, firmware version, Bluetooth RSSI) and make detailed settings. -
Set Auto Health Monitor Interval
Turn on/off automatic heart rate/Sp02/blood pressure/HRV/stress/skin temperature monitor via the App. You can change the interval according to your needs, the shorter the interval is set, the faster the battery will drain.
• Blood Pressure Calibration: before measuring your blood pressure, you can calibrate it by entering your true value on the App to improve the accuracy to some extent. -
Goal Setting
Personalize your goals for steps, distance, calories and sleep hour per day. -
Alarm Clock
Set the alarm clock on the App according to your needs. -
Device Settings
It includes settings for Bluetooth disconnect reminder, smart notifications, sedentary alert, firmware update and factory reset. -
Smart Notifications
Different notifications have different lighting and vibrating indication, as follows:
Frequency of Purple Light Flashing and Vibrating| Indication|
Whether Bluetooth Connection is Required
---|---|---
Once per Second| Incoming Call| Yes
Twice| SMS & 30 Party App (WeChat. WhatsApp, Skype. etc.)| Yes
Twice| Sedentary Reminder| No
7 Times| Alarm Clock| No
Note: the above notifications can be stopped by pressing the home button
once.
-
Firmware Update (OTA)
Remind you if a new firmware version has been released; if so, please follow the steps to upgrade to the latest version. There is no indicator light during the update process, and when the update is finished, it will light up in different colors to indicate different power levels. -
Factory Reset
After factory reset, all device data will be deleted. Please charge to reboot. -
SOS
To enable SOS feature, firstly you need to set emergency contact info (name & phone number) on the App, up to 3 emergency contacts can be added. The SOS feature can only be effectively triggered when the device’s Bluetooth is connected to the APP. An SOS message will be sent to the emergency contact, including your name and GPS location.
In standby mode, long press home button for 3 times to trigger SOS message alert. If the white light flashes quickly for 3 times, it indicates successful sending; if the red light flashes quickly for 3 times, it indicates Bluetooth is not connected, please connect Bluetooth first.
Exercise
You can turn on exercise mode on the device or App. -
Turn on from the device: first preset an exercise mode on the App. Short press the home button 3 times to start the exercise, the green light will be on for 2 seconds, then flashing, you can press the home button to pause or resume the exercise; if you pause the exercise, it will flash blue light; you can short press the home button 3 times to end the current exercise, the green light will be on for 2 seconds and then go off.
During exercise, different lights indicate different exercise heart rate zones: if you enter warm-up, fat burn and aerobic exercise, the green light will flash; if you enter anaerobic and intense exercise, the red light will flash, at the same time, the device will vibrate 3 times for high heart rate alert. -
Turn on from the App: there are 54 exercise modes in total and you can choose any 18 modes to be displayed on the Exercise panel. Turn on/off exercise mode on the App according to your needs.
My
Check basic App settings: personal information, data share, login account management, App background, about us, feedback support, App version updates, etc.
Specifications
Warranty: 12 months
BT Version: BLE 5.0
BT Range: 10 meters
Size: 41.98’21.87413.5mm
Battery: 95mAh rechargeable lithium polymer battery. non-replaceable
Data Memory: 30 days
Waterproof: IP68
Activity Time: 99 h 59 min
Calories Burned: Max 9999.9 kcal
Running & Walking Distance: Max 999.99km
Troubleshooting
If the device doesn’t pair with your smartphone
- Make sure your device is turned on.
- Check your smartphone to ensure Bluetooth is on.
- Check the app to make sure Bluetooth permissions are turned on. This should be in your Bluetooth settings.
- Restart the app and go to the app home screen.
- The device battery should display on your app device screen.
If the device isn’t measuring any data
Please contact our support team.
If the device battery is draining too quickly
- Calibrate your battery by charging it for at least three hours.
- Start using your device again as you normally would.
- Contact our support team if the problem persists.
If the device causes an allergic reaction
Please stop using the device right away. In the rare event of an anaphylactic
reaction, seek medical attention immediately.
If the issue isn’t mentioned in these tips
Please contact our support team and report the issue in detail.
Safety Notices
Failure to follow these safety instructions could result in fire, electric
shock, injury, or damage to the device or other property. Read all the safety
information below before using the device.
Not a Medical Device
It’s not a medical device and should not be used as a substitute for
professional medical judgment. It is not designed or intended for use in the
diagnosis of disease or other conditions, or in the cure, mitigation,
treatment, or prevention of any condition or disease. Please consult your
healthcare professional prior to making any decisions related to your health.
Handling
Handle this device with care as it contains sensitive electronic components
and can be damaged if dropped, burned, punctured, or crushed. Don’t use a
damaged Move Wearable as it may cause injury. Avoid heavy exposure to dust or
sand. Children should not be allowed to play with the device without
supervision.
Battery
Do not attempt to replace the device battery yourself, you may damage the
battery, which could cause overheating and injury. The lithium-ion battery in
the device should be serviced only by manufacturer or an authorized service
provider. Batteries must be recycled or disposed of separately from household
waste. Do not incinerate the battery. Do not dispose of the device in domestic
waste. If you have any questions, please contact us.
Operating Temperature
This device is designed to work in ambient temperatures between 32°F and 113°F
(0°C and 45°C) and be stored in temperatures between -4°F and 158°F (-20°C and
70°C). It can be damaged and battery life shortened if stored or operated
outside of these temperature ranges. Avoid exposing this device to dramatic
changes in temperature or humidity.
Prolonged Heat Exposure
Do not expose the device to extreme temperatures or extreme temperature
fluctuations. Protect the device from direct sunlight. While this device is
charging or the power plug is plugged into a power source, do not sleep on it
or place it under a blanket, pillow, or your body. Take special care if you
have a physical condition that affects your ability to detect heat against the
body.
FCC Requirement
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC RF exposure statement:
The device has been evaluated to meet general RF exposure requirement. The
device can be used in portable exposure condition without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>