- INTRODUCTION
- SAFETY INFORMATION & INSTRUCTIONS
- SPECIAL INFORMATION
- MAINTENANCE
- **REMOVAL: CARTRIDGE MECHANICAL SEAL
- INSTALLATION: CARTRIDGE MECHANICAL SEAL
- REMOVAL.: PACKING
- INSTALLATION: PACKING
- PUMP DISASSEMB
- PUMP ASSEMBLY
- THRUST BEARING ADJUSTMEN
- INSTALLATION: CARBON GRAPHITE BUSHINGS
- PRESSURE RELIEF VALVE INSTRUCTIONS
- GENERAL INSTALLATION NOTES
- FOUNDATION
- COMPONENT & UNIT LIFTING FEATURES
- ALIGNMENT
- PIPING
- START UP
- TROUBLESHOOTING
- RAPID WEAR
- PREVENTATIVE MAINTENANCE
- OPERATION
- MAINTENANCE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
123A Series Universal Seal Gear Pump
User Manual
123A Series Universal Seal Gear Pump
VISIT VIKINGPUMP.COM FOR PDF OF CURRENT TSM ISSUE &
TO VIEW REPAIR VIDEOS
TECHNICAL SERVICE MANUAL: INSTALLATION, OPERATION & MAINTENANCE
UNIVERSAL PRODUCT LINE: STEEL EXTERNALS
123A SERIES™, 4123A SERIES™, 223A SERIES™, 4223A SERIES™, 323A SERIES™, 4323A
SERIES™ SIZES: H, HL, K, KK, LQ, LL, LS, Q, QS, N, R, RS
MODEL NUMBER CHART
NON-JACKETED | JACKETED |
---|---|
Packed | Mech. Seal |
H123A | H4123A |
HL123A | HL4123A |
K123A | K4123A |
KK123A | KK4123A |
LQ123A | LQ4123A |
LL123A | LL4123A |
LS123A | LS4123A |
Q123A | Q4123A |
QS123A | QS4123A |
N323A | N4323A |
R323A | R4323A |
RS323A | RS4323A |
INTRODUCTION
The illustrations used in this manual are for identification purposes only and
cannot be used for ordering parts.
Obtain a parts list from your Viking Pump® representative.
Always give a complete name of part, part number and material with the model
number and serial number of pump when ordering repair parts. The unmounted
pump or pump unit model number and serial number are on the nameplate.
This manual only applies to the pump models specified in the “Model Number
Chart” on page 1. Pump specifications and recommendations are listed in the
Catalog Sections, which are available at
vikingpump.com.
SAFETY INFORMATION & INSTRUCTIONS
IMPROPER INSTALLATION, OPERATION OR MAINTENANCE OF PUMP MAY CAUSE SERIOUS
INJURY OR DEATH, AND/OR RESULT IN DAMAGE TO PUMP AND/OR OTHER EQUIPMENT.
VIKING’S WARRANTY DOES NOT COVER FAILURE DUE TO IMPROPER INSTALLATION,
OPERATION OR MAINTENANCE. THIS INFORMATION MUST BE FULLY READ BEFORE BEGINNING
INSTALLATION, OPERATION OR MAINTENANCE OF PUMP, AND MUST BE KEPT WITH PUMP.
PUMP MUST BE INSTALLED, OPERATED AND MAINTAINED ONLY BY SUITABLY TRAINED AND
QUALIFIED PERSONS.
THE FOLLOWING SAFETY INSTRUCTIONS MUST BE FOLLOWED AND ADHERED TO AT ALL
TIMES.
DANGER = FAILURE TO FOLLOW THE INDICATED INSTRUCTION MAY RESULT IN
SERIOUS INJURY OR DEATH.
DANGER
BEFORE opening any liquid chamber (pumping chamber, reservoir, relief valve
adjusting cap fitting, etc.) be sure that:
- Any pressure in the chamber has been completely vented through the suction or discharge lines or other appropriate openings or connections.
- The pump drive system (motor, turbine, engine, etc.) has been “locked out” or otherwise been made non-operational, so that it cannot be started while work is being done on the pump.
- You know what material the pump has been handling, have obtained a material safety data sheet (MSDS) for the material, and understand and follow all precautions appropriate for the safe handling of the material.
DANGER
BEFORE operating the pump, be sure all drive guards are in place.
DANGER
DO NOT operate pump if the suction or discharge piping is not connected.
DANGER
DO NOT place fingers into the pumping chamber, or its connection ports, or
into any part of the drive train if there is any possibility of the pump shaft
being rotated.
WARNING
DO NOT exceed the pumps rated pressure, speed, and temperature, or change the
system/duty parameters from those the pump was originally supplied, without
confirming its suitability for the new service.
WARNING
BEFORE operating the pump, be sure that:
- It is clean and free from debris.
- All valves in the suction and discharge pipelines are fully opened.
- All piping connected to the pump is fully supported and correctly aligned with the pump.
- Pump rotation is correct for the desired direction of flow.
WARNING = IN ADDITION TO SERIOUS INJURY OR DEATH, FAILURE TO FOLLOW THE
INDICATED INSTRUCTION MAY CAUSE DAMAGE TO PUMP AND/OR OTHER EQUIPMENT
WARNING
INSTALL pressure gauges/sensors next to the pump suction and discharge
connections to monitor pressures.
WARNING
USE extreme caution when lifting the pump. Suitable lifting devices should be
used when appropriate. Lifting eyes installed on the pump must be used only to
lift the pump, not the pump with drive and/or base plate. If the pump is
mounted on a base plate, the base plate must be used for all lifting purposes.
If slings are used for lifting, they must be safely and securely attached. For
weight of the pump alone (which does not include the drive and/or base plate)
refer to the Viking Pump® product catalog.
DANGER
DO NOT attempt to dismantle a pressure relief valve that has not had the
spring pressure relieved or is mounted on a pump that is operating.
DANGER
AVOID contact with hot areas of the pump and/or drive. Certain operating
conditions, temperature control devices (jackets, heat-tracing, etc.),
improper installation, improper operation, and improper maintenance can all
cause high temperatures on the pump and/or drive.
WARNING
THE PUMP must be provided with pressure protection. This may be provided
through a relief valve mounted directly on the pump, an in-line pressure
relief valve, a torque limiting device, or a rupture disk. If pump rotation
may be reversed during operation, pressure protection must be provided on both
sides of pump. Relief valve adjusting screw caps must always point towards
suction side of the pump. If pump rotation is reversed, position of the relief
valve must be changed. Pressure relief valves cannot be used to control pump
flow or regulate discharge pressure. For additional information, refer to
Appendix, General Installation Notes, item 5 on Pressure Protection or contact
your Viking Pump® representative for Engineering Service Bulletin ESB-31.
WARNING
THE PUMP must be installed in a manner that allows safe access for routine
maintenance and for inspection during operation to check for leakage and
monitor pump operation.
SPECIAL INFORMATION
ROTATION
Viking pumps can operate equally well in a clockwise or counter-clockwise
rotation; however, some constructions may require modifications. Consult your
Viking Pump® representative if unsure. Shaft rotation determines which port is
suction and which is discharge. Suction port is where pumping elements (gear
teeth) come out of mesh.
If pump rotation is reversed during operation, pressure protection must be
provided on both sides of pump.
Relief valve adjusting screw cap must always point towards suction side of
pump. If pump rotation is reversed, remove pressure relief valve and turn end
for end.
CIRCULATION LINES
This equipment (not utilized on all pumps) must be connected properly. Packed
pumps typically have a flush line from packing chamber to discharge port.
Mechanical seal pumps typically have a subpack line from seal chamber to
suction port. If pump rotation is reversed, be sure circulation connections
are connected to the suction or discharge port as noted above to avoid
excessive leakage or damage to pump. If pump is handling heated product, be
sure circulation line is insulated to assure continued flow.
JACKETED PORTS
Jackets are utilized to heat (or cool) the pump and liquid in the pump prior
to startup. Not all pumps have ports for jacketing. Jacketing port locations
vary by model.
PRESSURE RELIEF VALVES
- Viking pumps are positive displacement pumps and must be provided with some sort of pressure protection. This may be a relief valve mounted directly on the pump, an inline pressure relief valve, a torque limiting device or a rupture disk.
- There are relief valve options available on those pump models designed to accept a relief valve. Options may include a jacketed relief valve or return to tank relief valve.
- If pump rotation is reversed during operation, pressure protection must be provided on both sides of pump.
- Relief valve adjusting screw cap must always point towards suction side of pump, see “Figure 5” on page 8. If pump rotation is reversed, remove pressure relief valve and turn end for end.
- Pressure relief valves cannot be used to control pump flow or regulate discharge pressure.
For additional information on pressure relief valves, refer to Appendix,
General Installation Notes, item 5 on Pressure Protection or contact your
Viking Pump® representative for Engineering Service Bulletin ESB-31.
MECHANICAL SEALS
Extra care should be taken in repair of pumps with mechanical seals. Be sure
to read and follow all special instructions supplied with your pump.
MAINTENANCE
These pumps are designed for long, trouble-free service life under a wide
variety of application conditions with minimum maintenance. The points listed
below will help provide long service life.
LUBRICATION
External lubrication must be applied slowly with a hand gun to all lubrication
fittings every 500 hours of operation with multi-purpose grease, NLGI # 2.
Contact your Viking Pump® representative with specific lubrication questions.
Engineering Service Bulletin ESB-515 is located in the Appendix for standard
grease thickener types used by Viking to check compatibility. Applications
involving very high or low temperatures will require other types of
lubrication.
PACKING ADJUSTMENT
New packed pumps require initial packing adjustment to control leakage as
packing ‘runs in”. Make initial adjustments carefully and do not over -tighten
packing gland. After initial adjustment, inspection will reveal need for
packing gland adjustment or packing replacement. Contact your Viking Pump®
representative for Engineering Service Bulletin ESB-521 regarding repacking
pump.
CLEANING PUMP
Keep pump as clean as possible. This will facilitate inspection, adjustment
and repair work and help prevent overlooking a dirt covered grease fitting.
STORAGE
If pump is to be stored, or not used for six months or more, pump must be
drained and a light coat of non-detergent SAE 30 weight oil must be applied to
all internal pump parts. Lubricate fittings and apply grease to pump shaft
extension. Viking suggests rotating pump shaft by hand one complete revolution
every 30 days to circulate the oil. Tighten all pump assembly bolts before
putting pump in service after being stored.
SUGGESTED REPAIR TOOLS
The following tools must be available to properly repair these pumps. These
tools are in addition to standard mechanics’ tools such as open-end wrenches,
pliers, screwdrivers, etc. Most of the items can be obtained from an
industrial supply house.
-
Soft headed hammer
-
Allen wrenches (some mechanical seals and set collars)
-
Packing hooks, flexible (packed pumps)
-
Mechanical seal installation sleeve
2-751-002-730 for 1.125 inch seal; H-HL pumps
2-751-003-730 for 1.4375 inch seal; K-LL pumps
2-751-005-630 for 2.4375 inch seal; Q-QS pumps
2-751-006-630 for 3.4375 inch seal; N pumps
2-751-010-630 for 4.5000 inch seal; R & RS pumps.
No sleeve needed for LS pumps -
Bearing locknut spanner wrench
Source: #471 J. H. Williams & Co. or equal; H-LL pumps
Source: #472 J. H. Williams & Co. or equal; LS-QS pumps -
Spanner wrench, adjustable pin type for bearing housing and end cap
Source: #482 J. H. Williams & Co. or equal; H-QS pumps
Source: Groco SW2531 or equal; N-RS pumps -
Brass or plastic bar
-
Arbor press
FIGURE 6: EXPLODED VIEW (H, HL, K, KK, LQ, LL, LS SIZES) — 123A SERIES™,
4123A SERIES™, 223A SERIES™, 4223A SERIES™
NOTE: IMAGE IS REPRESENTATIVE ONLY
Item| Name Of Part| Item| Name Of Part| Item| Name
Of Part
---|---|---|---|---|---
1| Locknut| 17| Caps crews, Seal Gland| 35| Head Gasket
2| Lock washer| 19| Cartridge Seal| 36| Rotor and Shaft
Assembly
3| End Cap| 19| Packing| 37| Idler and Bushing Assembly
4| Bearing Spacer Collar (Outer)| 19| Mechanical Seal| 38|
Idler Bushing
5| Lip Seal| 20| Packing Retaining Washer| 39| Idler Pin
6| Ball Bearing| 21| Mechanical Seal Collar| 40| Head and
Idler Pin Assembly
7| Bearing Housing| 25| Bracket Bushing| 41| O-Ring for
Jacket Head Plate
8| Bearing Spacer Collar (Inner)| 27| Bracket and Bushing
Assembly| 42| Jacket Head Plate
11| Ring, Half Round (Not H, HL)| 28| Caps crew for Bracket|
43| Caps crew for Head
12| Grease Fitting| 29| Bracket Gasket| 45| Relief Valve
Gasket
15| Packing / Mechanical Seal Gland| 30| Pipe Plug| 46| Caps
crew for Valve
16| Packing / Mechanical Seal Gland Nut| 31| Casing (Tapped or
Flanged)| 47| Internal Relief Valve
FIGURE 7: EXPLODED VIEW (Q, QS SIZES) — 123A SERIES™, 4123A SERIES™, 223A SERIES™, 4223A SERIES™ NOTE: IMAGE IS REPRESENTATIVE ONLY
Item| Name Of Part| Item| Name Of Part| Item| Name
Of Part
---|---|---|---|---|---
1| Locknut| 17| Packing Gland Caps crew| 38| Idler Bushing
2| Lock washer| 17A| Retainer for Packing Bolts| 39| Idler
Pin
3| End Cap for Bearing Housing| 19| Packing| 40| Head and
Pin Assembly
4| Bearing Spacer Collar (Outer)| 25| Bracket Bushing| 43|
Stud for Head
5| Lip Seal for Bearing Housing (2 Riq’a)| 27| Bracket and Bushing
Assembly| 44| Nut for Head
6| Roller Bearing (2 Riq’a)| 28| Caps crew for Bracket| 45|
Relief Valve Gasket
7| Bearing Housing| 29| Bracket Gasket| 46| Caps crew for
Relief Valve
8| Bearing Spacer Collar (Inner)| 30| Pipe Plug| 47|
Internal Relief Valve
12| Grease Fitting| 31| Casing| 50| Packing Gland Washer (2
Riq’a)
13| Mechanical Seal| 34| Pipe Flange Gasket| 51| Stud for
Flanges
13B| Cartridge Mechanical Seal| 35| Head Gasket| 52| Nut for
Flanges
15| Packing Gland| 36| Rotor and Shaft Assembly| |
16| Packing Gland Nut| 37| Idler and Bushing Assembly| |
FIGURE 8: EXPLODED VIEW (N, R, RS SIZES) — 324A SERIES™, 4324A SERIES™ NOTE: IMAGE IS REPRESENTATIVE ONLY
Item| Name Of Part| Item| Name Of Part| Item| Name
Of Part
---|---|---|---|---|---
1| Locknut| 15| Mechanical Seal| 29| Flush / Subpack Line
2| Lock washer| 16| Grease Fitting| 30| Pipe Plug
3| End Cap for Bearing Housing| 17| Pipe Plug| 31| Stud for
Head
4| Lip Seal for Bearing Housing (2 Req’d)| 18| Bracket and Bushing
Assembly| 32| Nut for Head
5| Bearing Spacer Collar| 19| Pipe Plug| 33| Rotor and Shaft
Assembly
6| Roller Bearing (2 Req’d)| 20| Bracket Bushing| 34| Idler
and Bushing Assembly
7| Bearing Housing| 21| Nut for Bracket| 35| Idler Bushing
8| Packing Gland Nut| 22| Bracket Gasket| 36| Head Gasket
9| Packing Gland Washer| 23| Stud for Bracket| 37| Idler Pin
10| Packing Gland Stud| 24| Pipe Plug| 38| Head and Idler
Pin Assembly
11| Packing Gland| 25| Locating Pin| 39| Relief Valve Gasket
12| Packing| 26| Casing| 40| Internal Relief Valve
13| Packing Retaining Washer| 27| Nut for Flanges| 41| Caps
crew for Relief Valve
14| Seal Plate| 28| Stud for Flanges| 42| Cover Plate
DANGER
Before opening any Viking pump liquid chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.) be sure:
- That any pressure in the chamber has been completely vented through the suction or discharge lines, or other appropriate openings or connections.
- That the driving means (motor, turbine, engine, etc.) has been “locked out” or made non-operational, so that it cannot be started while work is being done on pump.
- That you know what liquid the pump has been handling and the precautions necessary to safely handle the liquid. Obtain a material safety data sheet (MSDS) for the liquid to be sure these precautions are understood.
Failure to follow above listed precautionary measures may result in serious injury or death.
**REMOVAL: CARTRIDGE MECHANICAL SEAL
**
Cartridge mechanical seals are designed so that they may be replaced with minimal pump and piping disassembly
- Insert brass or plastic bar through port opening between rotor teeth to keep shaft from turning. Bend up tang of lockwasher and with a spanner wrench, remove locknut and lockwasher from shaft.
- Loosen two set screws in the face of the bearing housing and remove the bearing housing assembly from the bracket.
- Remove the pair of half round rings (K, KK, LQ, LL, LS sizes only) under the inner spacer collar from the shaft.
- Remove any flush or barrier fluid tubes connected to the seal gland.
- Replace or turn centering clips to original position.
- Loosen setscrews on the seal collar to free the cartridge seal from the shaft.
- Loosen and remove the two nuts holding the seal to the pump and slide the cartridge seal out through the bearing housing opening.
If the pump is to be disassembled further, refer to “Pump Disassembly” on page 9.
INSTALLATION: CARTRIDGE MECHANICAL SEAL
-
NOTE: Burrs left on shaft can damage O-ring on seal sleeve during installation. Inspect shaft for burrs and remove any found with a fine grade of emery cloth.
-
Clean rotor shaft and face of seal chamber.
-
Place tapered installation sleeve on shaft. Coat rotor shaft, tapered installation sleeve, and O-ring in the inside diameter of cartridge seal sleeve with a generous amount of P-80° or equivalent. See “Figure 9” on page 7.
-
Slide cartridge seal over installation sleeve on shaft until it contacts the seal chamber face. Remove tapered installation sleeve from shaft.
-
Place pair of half round rings in groove on shaft (K, KK, LQ, LL, LS sizes only) and turn bearing housing assembly into bracket.
-
Put lock washer and locknut on shaft. Tighten locknut and bend one tang of lock washer into slot of locknut. See “Table 3” on page 11.
-
Adjust pump end clearance, refer to “Thrust Bearing Adjustment”” on page 11.
-
Insert gland caps crews and secure gland to bracket face using washers and nuts.
NOTE: turn shaft several turns while gland is loose to center seal; then tighten nuts enough to compress gland gasket. Tighten only enough to contain leakage and not to distort gland. -
Tighten setscrews on seal drive collar to shaft. Remove or turn centering clips out of the way so as to clear the drive collar.
-
Turn shaft by hand or jog motor to check drive collar for runout.
-
Connect circulation line or vent stuffing box seals without circulation line until liquid is present on start up.
NOTE: For maximum seal life, circulation line should be used.
DANGER’!
Before starting pump, be sure all drive equipment guards are in place.
Failure to properly mount guards may result in serious injury or death.
NOTE: Coat rotor shaft, tapered installation sleeve and inner diameter of
mechanical seal with P-80® or equivalent before assembly.
P-80° is a registered trademark of Intonational Products Corporation
DANGER
Before opening any Viking pump id chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.) be sure:
- That any pressure in the chamber has been completely vented through the suction or discharge lines, or other appropriate openings or connections.
- That the driving means (motor, turbine, engine, etc.) has been “locked out” or made non-operational, so that it cannot be started while work is being done on pump.
- That you know what liquid the pump has been handling and the precautions necessary to safely handle the liquid. Obtain a material safety data sheet (MSDS) for the liquid to be sure these precautions are understood.
Failure to follow above listed precautionary measures may result in serious
injury or death.
REMOVAL: COMPONENT MECHANICAL SEAL
Elastomeric bellows, elastomeric o-ring and PTFE wedge seals generally
require pump disassembly to be replaced (refer to “Pump Disassembly”” on page
9).
-
Insert brass or plastic bar through port opening between rotor teeth to keep shaft from turning. Bend up tang of lockwasher and with a spanner wrench, remove locknut and lockwasher from shaft.
-
Loosen two set screws in the face of the bearing housing and remove the bearing housing assembly from the bracket.
-
Remove the pair of half round rings (K, KK, LQ, LL, LS sizes only) under the inner spacer collar from the shaft.
-
Loosen nuts and remove seal holder, seal seat and seal gasket(s).
-
Loosen setscrews in mechanical seal rotary member.
NOTE: Circulation line and/or plugs will need to be removed to access setscrews. If changing the mechanical seal is the extent of the maintenance to be performed, then the rotor shaft assembly only needs to be moved far enough to dislodge the rotary member of the seal. -
Drive the rotor/shaft assembly out of the casing until the rotor teeth extend past the face of the casing.
-
Push the rotor/shaft assembly back into the casing. The rotary member of the seal should now be pushed far enough down the shaft for easy removal.
INSTALLATION: COMPONENT MECHANICAL SEAL
-
Clean rotor shaft and seal housing bore. Make sure they are free of dirt, grit and scratches. Gently radius leading edge of the shaft diameter over which seal is to be placed.
Never touch mechanical seal faces with anything except clean hands or clean cloth. Minute particles can scratch the seal faces and cause leakage. -
Place tapered installation sleeve on the shaft. Coat tapered sleeve and inside of the rotary member with a generous quantity of P-80% or equivalent. Grease is not recommended. Start rotary member on shaft and over tapered sleeve. See “Figure 10” on page 8.
-
Move rotary member so setscrews are directly below seal access holes on side of bracket. Tighten all setscrews securely to shaft. Some seals are equipped with holding clips which compress the seal springs. Remove holding clips to release springs after seal is installed on shaft.
-
FOR “O-RING” GASKET TYPE MECHANICAL SEAL
SEAT: Lubricate outer diameter of O-Ring seal gasket with P-80° or equivalent. Press seal seat in to bore until back, unlopped face, is flush with bore. Install seal holder, caps crews, and nuts and tighten securely. Remove tapered installation sleeve.
FOR “CLAMPED-IN” TYPE MECHANICAL SEAL SEAT:
Flush sealing faces of both rotary member and seal seat with oil and install seal seat and seat gasket over end of shaft against machined bracket face. Install other seal gasket, seal holder, caps crews, and nuts and tighten securely. Remove tapered installation sleeve. -
Connect subpack or flush line or vent stuffing box for seals without circulation line until liquid is present on start up.
NOTE: For maximum seal life, subpack or flush line should be used.
DANGER
Before starting pump, be sure all drive equipment guards are in place.
Failure to properly mount guards may result in serious injury-or death.
NOTE: Coat rotor shut, tapered installation sleeve and inner diameter of
mechanical seal with P-80® or equivalent before assembly.
DANGER
Before opening any Viking pump liquid chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.) be sure:
- That any pressure in the chamber has been completely vented through the suction or discharge lines, or other appropriate openings or connections.
- That the driving means (motor, turbine, engine, etc.) has been “locked out” or made non-operational, so that it cannot be started while work is being done on pump.
- That you know what liquid the pump has been handling and the precautions necessary to safely handle the liquid. Obtain a material safety data sheet (MSDS) for the liquid to be sure these precautions are understood.
Failure to follow above listed precautionary measures may result in serious injury or death.
REMOVAL.: PACKING
- Insert a brass or plastic bar through port opening between rotor teeth or lock coupling end of shaft to keep shaft from turning. Bend up tang of lock washer and with a spanner wrench; remove locknut and lock washer from shaft. Remove brass or plastic bar from port opening.
- Loosen the two setscrews in the face of the bearing housing and remove the bearing housing assembly from the bracket. See “Figure 12” on page 10, “Figure 13” on page 10 or “Figure 14” on page 10.
- K KK, LQ, LL, LS Sizes ONLY: Remove pair of half round rings under the inner spacer collar from the shaft.
- Remove pipe plug from drain hole in casing or bracket, breaking vacuum behind rotor.
- Remove packing gland nuts. Slide packing gland out of stuffing box, and remove packing and packing retainer washer.
NOTE: Contact your Viking Pump® representative for Engineering Standard ES-9 on packing information & options.
INSTALLATION: PACKING
- When assembling packed pump, use packing suitable for liquid being pumped. Install packing, staggering the joints from one side of shaft to other. Seat each ring with a short length of pipe or similar; tool to ensure each ring is seated. Lubricate packing rings with oil, grease, or graphite to aid assembly. Install packing, capscrews / studs, washers and retainer (Q, QS, M only) and nuts. Make sure gland is installed square and nuts are tightened evenly. Tighten nuts until packing gland is snug against packing. DO NOT OVER-TIGHTEN!
TABLE 1: PACKING RING CHART
Pump Size | Number of Packing Rings |
---|---|
H, HL | 5 |
K, KK, LQ, LL, LS | 6 |
Q, QS, N, R, RS | 7 |
PUMP DISASSEMB
- Mark head and casing before disassembly to ensure proper reassembly. The idler pin, which is offset in pump head, must be positioned toward and equal distance between port connections to allow for proper flow of liquid through the pump.
Remove nuts and caps crews from head. Jackscrews should be used with N, R & RS size pumps to back head away from casing. Proper size and length of jackscrews for pump size are shown in “Figure 11” on page 9. The use of a hoist to support head will facilitate its removal. Pump Size| No. Screws Used| A| Thread Size (Inch)
---|---|---|---
N| 2| 4.00| 0.50” – 13 NC
R & RS| 2| 4.50| 0.63” – 11 NC
Avoid damaging head gasket. Back head slightly away from casing. Do not allow
idler to fall from idler pin. To prevent this, tilt top of head back when
removing. Remove head from pump. A lifting hook for N, R & RS size pumps will
provide adequate connection for hoisting head. If a hoist is not available,
cribbing or blocking can be used to support head. This will eliminate having
to lift head into position when reassembling pump.
If pump is furnished with pressure relief valve, it need not be removed from
head or disassembled at this point; however, removing relief valve will lessen
total weight of part. Do not use chain or cable around relief valve body to
support head during removal. Refer to “Pressure Relief Valve Instructions” on
page 12.
If pump has jacketed head plate, it will separate from head when it is
removed. The gasket between head and jacket head plate must be totally
removed. Use new gasket when assembling pump.
-
Remove head gasket, idler and bushing assembly.
-
Carefully remove rotor and shaft to avoid damaging bracket bushing.
-
Loosen two radial setscrews in flange of bearing housing and with a spanner wrench remove the outer end cap with lipseal and outer bearing spacer collar.
-
Remove the double row ball bearing, (2 tapered roller bearings on Q, @S, N, R, RS sizes), lipseal and inner bearing spacer collar from the bearing housing.
-
Clean all parts thoroughly and examine for wear and damage. Check lipseals, bearings, bushings, and idler pin and replace if necessary. Check all other parts for nicks, burrs, excessive wear and replace if necessary. Wash bearings in clean solvent. Blow out bearings with compressed air. Do not allow bearings to spin; turn them slowly by hand. Spinning bearings will damage bearing components. Make sure bearings are clean, then lubricate with light oil and check for roughness. Roughness can be determined by turning outer race by hand.
CAUTION
Do not intermix inner and outer races of tapered roller bearing (Q, @S, N, R, RS sizes) -
Casing can be checked for wear or damage while mounted on bracket.
-
Inspect bracket bushing for wear and remove if damaged or worn.
FIGURE 12: BEARING HOUSING ASSEMBLY (H, HL) FIGURE 13: BEARING HOUSING ASSEMBLY (K, KK, LQ, LL, LS) FIGURE 14: BEARING HOUSING ASSEMBLY (@, @s, N, R,RS)
PUMP ASSEMBLY
-
Install bracket bushing if removed due to wear. If bracket bushing has an inner lubrication groove, install bushing with groove at twelve o’clock position in bracket. If carbon graphite, Refer to “Installation: Carbon Graphite Bushings” on page 12.
-
Install bracket and bushing assembly on the casing if separated during assembly. The locating pin is essential for proper alignment for N, R, RS sizes. Be sure gasket is placed between bracket and casing.
-
Coat shaft of rotor / shaft assembly with light oil. Start end of shaft in bracket bushing turning from right to left, slowly pushing rotor in casing.
-
Coat idler pin with light oil and place idler and bushing on idler pin in head. If replacing with carbon graphite bushing, Refer to “Installation: Carbon Graphite Bushings” on page 12.
-
Using a.010 to .015inch thick head gasket, install head and idler assembly on pump. Pump head and casing should have been marked before disassembly to ensure proper reassembly. If not, be sure idler pin, which is offset in pump head, is positioned toward the equal distance between port connections to allow for proper flow of liquid through pump. If pump is equipped with jacketed headlight, install at this time along with a new gasket. Tighten head caps crews evenly.
See ti Figure 12″ on page 10, “Figure 13″ on page 10 or igure 14” on page 10 for bearing housing assembly. -
Install the lipase in the bearing housing (See “Figure 12” on page 10, “Figure 13” on page 10 or “Figure 14” on page 10 for lip orientation).
-
H,HL, K, KK, LQ, LL, LS Sizes: Pack the ball bearing with grease and push or press the bearing into the bearing housing. See “Figure 12” on page 10 or “Figure 13” on page 10. Q, @S, N, R, RS Sizes: Pack tapered roller bearings with grease and press or push bearings into housing with large end of inner races together. It is possible to install bearings incorrectly. For proper assembly see “Figure 14” on page 10.
-
Install the lipseal in the end cap (see appropriate figure for lip orientation). Thread the end cap into the bearing housing along with outer bearing spacer collar and tighten against the bearing.
Q, @S, N, R, RS Sizes ONLY: Tapered roller bearings require preload to operate properly. To set preload tighten end cap so that inner races of bearings cannot be rotated by hand. Make a mark on the outside diameter of the bearing housing and a corresponding mark on the bearing housing end cap. Rotate the bearing housing end cap in a counter clockwise direction until the mark on the outside diameter of the bearing housing is past the mark on the bearing housing end cap by the amount specified in “Table 2” on page 11. This will provide the correct end play for the bearings.
Lock end cap in place with two setscrews in the flange of the bearing housing.
TABLE 2: END CAP ADJUSTMENT
Pump Size| Inches (mm)
---|---
Q, QS, M| 0.270 in. (6.86 mm)
N| 0.375 in. (9.52mm)
R, RS| 0.422 in. (10.72mm)
NOTE: Refer to “Installation: Cartridge Mechanical Seal” on page 7 or “Installation: Component Mechanical Seal” on page 8 when reassembling itch mechanical seal. Refer to “Installation: on page 9 for a pump with packing.
- Slide inner spacer collar over shaft with recessed end facing rotor. H, HL, Q, QS bearing spacer collars are not recessed. K, KK, LQ, LL, LS Sizes ONLY: Place pair of half round rings on shaft and slide inner bearing spacer collar over half round rings to lock them in place.
- Thread the bearing housing with lipases; end cap, outer bearing spacer collar and bearings installed into bracket.
- Put lock washer and locknut on shaft. Insert brass or plastic bar through port opening between rotor teeth to keep shaft from turning. Tighten locknut as per “Table 3” on page 11. If tang does not line up with slot, tighten locknut until it does. Failure to tighten locknut or engage lock washer tang could result in early bearing failure and cause damage to rest of pump. Remove brass or plastic bar from port opening.
TABLE 3: LOCKNUT TORQUE Pump Size| Torque (Ft.-Lbs.)
---|---
H, HL| 50-70
K, KK, LQ, LL| 100-130
LS| 120-150
Q, QS, N, R, RS| 170-190 - adjust pump end clearance, refer to “Thrust Bearing Adjustment”” on page 11.
- Reinstall drain plug in casing / bracket.
- Lubricate all grease fittings with multi-purpose grease, NLGI #2. The factory uses polyurea type grease. Thoroughly clean out grease if using another grease chemistry.
DANGER’!
Before starting pump, be sure all drive equipment guards are in place.
Failure to properly mount guards may result in serious injury or death.
DANGER!
Before opening any Viking pump liquid chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.) be sure:
- That any pressure in the chamber has been completely vented through the suction or discharge lines, or other appropriate openings or connections.
- That the driving means (motor, turbine, engine, etc.) has been “locked out” or made non-operational, so that it cannot be started while work is being done on pump.
- That you know what liquid the pump has been handling and the precautions necessary to safely handle the liquid. Obtain a material safety data sheet (MSDS) for the liquid to be sure these precautions are understood.
Failure to follow above listed precautionary measures may result in serious injury or death.
THRUST BEARING ADJUSTMEN
- Loosen the two set screws in the outer face of the bearing housing and rotate the bearing housing in a clockwise direction until it cannot be turned any more. This ensures the rotor is all the way forward and’is touching the head. It will not be possible to turn the rotor by hand in this location.
- Make a mark on the outside diameter of the bearing housing and a corresponding mark on the bearing bracket.
- Rotate the bearing housing in a counter clockwise direction until the mark on the outside diameter of the bearing housing is past the mark on the bearing bracket per “Table 4” on page 12. This will provide the standard end clearance for the pump. If possible, check end clearance with feeler gauge between idler and rotor faces. Operating the pump at higher temperatures or viscosities may require additional end clearance. Contact your Viking Pump® representative for those clearances. “Table 4″ on page 12 shows the additional bearing housing adjustment required for .001” increase in end clearance.
- Tighten setscrews in the outer face of the bearing housing.
- Rotate the rotor shaft by hand to make sure it turns freely.
TABLE 4: END CLEARANCE CHART
Size| Series| Standard End Clearance (Inches)|
Turn Bearing Housing CCW Length on OD (Inches)| Additional Length
on OD Bearing Housing for .001″ End Clearance (Inches)
---|---|---|---|---
H, HL| 123A Series™, 4123A Series™| 0.003| 0.75| .22
223A Series™, 4223A Series™| 0.007| 1.5| .22
K, KK, LQ, LL, LS| 123A Series™, 4123A Series™| 0.005| 1.25| .25
K, KK, LQ, LL| 223A Series™, 4223A Series™| 0.010| 2.50| .25
LS| 223A Series™, 4223A Series™| 0.010| 2.50| .25
Q, QS| 123A Series™, 4123A Series™| 0.010| 3.10| .31
223A Series™, 4223A Series™| 0.015| 4.65| .31
N| 323A Series™, 4323A Series™| 0.015| 6.09| .41
R, RS| 323A Series™, 4323A Series™| 0.020| 9.09| .45
INSTALLATION: CARBON GRAPHITE BUSHINGS
When installing carbon graphite bushings, extreme care must be taken to
prevent breaking. Carbon graphite is a brittle material and easily cracked. If
cracked, the bushing will quickly disintegrate. Using a lubricant and adding a
chamfer on the bushing and the mating part will help in installation.
The additional precautions listed below must be followed for proper
installation.
- Après must be used for installation.
- Be certain the bushing is started straight.
- Do not stop pressing operation until bushing is in proper position. Starting and stopping will result in a cracked bushing.
- Check bushing for cracks after installation.
Carbon graphite bushings with extra interference fits are frequently furnished for high temperature operation. These bushings must be installed by a shrink fit.
- Heat bracket or idler to 750°F.
- Install cool bushing with a press.
- If facilities are not available to reach 750°F. temperature, it is possible to install with 450°F. temperature; however the lower the temperature the greater the possibility of cracking the bushing.
Consult your Viking Pump® representative with specific questions on high
temperature applications.
NOTE: Bronze and hardened cast iron bushings can be pressed into the
mating part. Use steps 1 and 2 above.
PRESSURE RELIEF VALVE INSTRUCTIONS
FIGURE 15: RELIEF VALVE – ALL SIZES
NOTE: Image is representative only.
Valve – List Of Parts
V1.| Valve Cap| V6.| Valve Body
V2.| Adjusting Screw| V7.| Valve Spring(s)
V3.| Lock Nut| V8.| Poppet
V4.| Spring Guide| V9.| Cap Gasket
V5.| Bonnet| V10.| Bonnet Gasket*
*K KK, LQ,LL, LS, Q, @S, N, R, RS sizes only
DANGER’!
Before opening any Viking pump liquid chamber (pumping chamber, reservoir,
relief valve adjusting cap fitting, etc.) be sure:
- That any pressure in the chamber has been completely vented through the suction or discharge lines, or other appropriate openings or connections.
- That the driving means (motor, turbine, engine, etc.) has been “locked out” or made non-operational, so that it cannot be started while work is being done on pump.
- That you know what liquid the pump has been handling and the precautions necessary to safely handle the liquid. Obtain a material safety data sheet (MSDS) for the liquid to be sure these precautions are understood.
Failure to follow above listed precautionary measures may result in serious
injury or death.
DISASSEMBLY
Mark valve and head before disassembly to ensure proper reassembly.
- Remove valve cap.
- Measure and record length of extension of adjusting screw. Refer to “A” on “Figure 15” on page 12.
- Loosen locknut and back out adjusting screw until spring pressure is released.
- Remove bonnet, spring guide, spring and poppet from valve body. Clean and inspect all parts for wear or damage and replace if necessary.
ASSEMBLY
Reverse procedures outlined under Disassembly. If valve is removed for repairs
be sure to replace in same position. Relief valve adjusting screw cap must
always point towards suction side of pump. If pump rotation is reversed,
remove relief valve and turn end for end.
PRESSURE ADJUSTMENT
If a new spring is installed or if pressure setting of pressure relief valve
is to be changed from that which the factory has set; the following
instructions must be carefully followed.
- Carefully remove valve cap which covers adjusting screw. Loosen locknut which locks adjusting screw so pressure setting will not change during operation of pump.
- Install a pressure gauge in discharge line for actual adjusting operation.
- Tum adjusting screw CW (in) to increase pressure and CCW (out) to decrease pressure. For guidance dimensions, contact your Viking Pump® representative for Engineering Standard ES-37.
- Close the discharge line at a point beyond the pressure gauge. Limit the: amount of time the pump is being operated at this condition. The temperature inside the pump will rise rapidly. Gauge will show maximum pressure that valve will allow while pump is in operation.
- Once pressure is set, tighten locknut and replace cap gasket and valve cap.
IMPORTANT ORDERING INFORMATION
In ordering parts for pressure relief valve, always give model number and
serial number of pump as it appears on nameplate and name of part wanted. When
ordering springs, be sure to give pressure setting desired.
APPENDIX (FORMERLY TSM 000)
NOTE: This Appendix section is for reference only. Not all pump construction
features apply to pumps within this Technical Service Manual.
GENERAL INSTALLATION NOTES
Before installation is started, a few items of a general nature should be considered.
-
Location – always locate the pump as close as possible to the supply of liquid to be pumped. Locate it below the liquid supply if at all practical. Viking pumps are self priming but the better the suction conditions the better the performance.
-
Accessibility the pump should be located where it is accessible for inspection, maintenance, and repair. For large pumps, allow room to remove the rotor and shaft without removing the pump from the base.
-
Port Arrangement – since the pumps have different port arrangements depending on the model, port location should be checked before starting the installation. The ports may be upright, opposite or at right angles to each other, see Figure A1. The right angle ports are normally right-hand, see Figure A2; some models are available with left-hand arrangements; still other models are available with the right angle ports located in any one of eight positions including right-hand and left-hand.
-
Suction/Discharge – shaft rotation will determine which port is suction and which is discharge. A look at Figure A3 will show how rotation determines which port is which. As the pumping elements (gears) come out of mesh, point “A” on Figure A3, liquid is rawn into the suction port. Then at point “B” the gears come into mesh, and the liquid is forced out the discharge port. Reversing the rotation reverses the flow through the pump. When determining shaft rotation, always look from the shaft end of the pump. Unless otherwise specified, rotation is assumed to be clockwise (CW), which makes the suction port on the right side of the pump. The idler pin, which is offset in the pump head, should be properly positioned toward and an equal distance between the port connections. See Figure A3 for correct idler pin location in relation to pump ports. FIGURE A4: CUTAWAY OF VIKING INTERNAL PRESSURE RELIEF VALVE FIGURE A5-A: INTERNAL PRESSURE RELIEF VALVE CAUTION
Internal type relief valves mounted on Viking pumps should always have the cap or bonnet pointed toward the suction side of the pump. Return-to-tank type relief valves should always be mounted on the discharge side of the pump. If pump rotation is reversed, change the relief valve. Turn the internal type end for end; move the return-to-tank type to the other port. If on a particular installation rotation is reversed, e.g., using one pump to fill a tank, and then by use of a reversing switch or other means of changing the rotation to permit the same pump to circulate the liquid through a heater or to load out, then pressure protection must be provided on both sides of the pump for both rotations. This may be a
combination of relief valves, torque limiting devices or rupture disks.
CAUTION’!
Pumps or systems without relief valves should have some form of pressure protection, e.g. torque limiting devices or rupture disks. -
Pressure Protection – Viking pumps are positive displacement pumps. This means that when the pump is rotated, liquid will be delivered to the discharge side of the pump. If there is no place for this liquid to go, i.e. the discharge line is blocked or closed, pressure can build up until the motor stalls, the drive equipment fails, a pump part breaks or ruptures, or the piping bursts. Because of this, some form of pressure protection must be used with a positive displacement pump. This may be a relief valve mounted directly on the pump, an inline relief valve, a torque limiting device or a rupture disk.
The pressure relief valve mounted on most Viking pumps and most in-line valves are of the spring-loaded poppet design. See Figure A4. The spring (a) holds poppet (b) against the seat in the valve body (c) with a given force determined by the spring size and by how tightly it is compressed by the adjusting screw (d). The pump discharge pressure pushes against the underside of the poppet at point (e). When the force exerted by the liquid under the poppet exceeds that exerted by the spring, the poppet lifts and liquid starts to flow through the valve.
As the discharge pressure builds up, more and more of the liquid flows through until a pressure is reached at which all of the liquid being pumped is going through the valve. This pressure is the relief valve setting.
Viking pumps can be furnished with either an internal pressure relief valve – one which directs the flow from the valve back to the suction side of the pump – or a return- to-tank valve – which directs the flow through piping back to the supply tank. See Figure A5-A and Figure A5-B.
An inline relief valve mounted in the discharge piping also directs the flow back to the supply tank. This type of valve should be mounted close to the pump so that the pressure drop through the piping between the pump and the valve is at a minimum. Be sure there are no shutoff valves between the pump and relief valve. Piping from a return- to-tank or an in-line valve to the supply tank should also be as short and as large as possible.
NOTE: On some models, the relief valve is mounted on the pump casing instead of the pump head.
The spring-loaded poppet-type valve is strictly a differential valve, sensing only those pressures on each side of the poppet. It should not be used as a pressure or flow control device. It is intended strictly as a relief valve.
The pressure at which either the return-to-tank or internal relief valve bypasses can be changed by turning the adjusting screw. Do not back the adjusting screw all the way out. Stop when spring tension is off the screw (the screw starts to turn easily). For details on maintenance of the relief valve, refer to the Technical Service Manual covering your model series. -
Motor – follow local electrical codes when hooking up motors.
FOUNDATION
Every pump should have a solid foundation. It may be any structure
sufficiently strong to hold the pump rigid and to absorb any strain or shock
that may be encountered. Acertified print of the pumping unit should be used
in preparing the foundation. If a separate foundation is provided, make it at
least four inches wider and longer than the base of the unit.
When the unit is placed on the foundation, it should be leveled and checked
for position against the piping layout and then fastened down.
COMPONENT & UNIT LIFTING FEATURES
Removable lifting features, such as threaded eye bolts and hoist rings, installed in components (pumps, reducers, motors, etc.) and baseplates should be left on the components. These features are used to safely lift and move the individual components. Following are general guidelines for lifting Viking Pump® units.
|
---|---
NOTE: Use two or more lifting slings around the pump and the motor when the base does not have lifting features. Make sure the slings are secure and the load is balanced before attempting to lift.
NOTE: NEVER lift the unit with slings unsecured under the base. The slings can slide, allowing the unit to tip and/or fall. Improper lifts can result in personal injury and/or damage to the unit.
NOTE: NEVER lift the unit with slings connected to the component lifting features. The lifting features are designed for the individual component and are not rated to lift the entire unit. Improper lifts can result in personal injury and/or damage to the unit.
Check width between these surfaces with inside calipers to be certain the faces are equal distance apart and parallel.
When sheaves are properly aligned, all points A, B, C, D will touch string or straightedge.
ALIGNMENT
CHECK ALIGNMENT AFTER MOUNTING
For detailed coupling alignment procedures see coupling manufacturers’
recommendations.
The pump, drive, and motor were properly aligned at the time they were
assembled. During shipping and mounting the alignment is often disturbed. BE
SURE TO RECHECK ALIGNMENT AFTER THE PUMP UNIT IS INSTALLED!
-
Check pump ports to be sure they are square and in the proper position; shim or move the pump as required. Do not force piping to line up with the ports.
-
If the pump is driven by a flexible coupling(s) either directly connected to the motor or through a reducer, remove any coupling guards or covers and check alignment of the coupling halves. At a minimum, a straightedge (such as a piece of key stock) across the coupling must rest evenly on both rims at the top, bottom, and sides. See Figure A10-A.
-
If the pump is driven by V-belts, check the alignment by using a long straightedge or tightly drawn string across the face of the sheaves. See Figure A10-B.
-
Make a final check on alignment after piping is hooked up. Refer to item 13 in Piping section.
Figure A11 and Figure A12 show typical direct drive and gear reducer drive units. -
For high temperature applications (those above 300°F) allow the pump to reach operating temperature, then recheck alignment.
|
---|---
PIPING
The cause of many pumping problems can be traced to suction piping. It should
always be as large and short as practical. For help in selecting the proper
size suction and discharge piping, refer to Viking General Catalog Section
510.
Before starting the layout and installation of your piping system, consider
the following points:
- Never use piping smaller than the pump port connections.
- Be sure the inside of the pipe is clean before hooking it to the pump.
- FOOT VALVE – When pumping a light liquid with a suction lift, a foot valve at the end of the suction piping or a check valve in the first horizontal run will hold the liquid in the line and make it easier for the pump to prime. Be sure the foot or check valve is big enough so that it doesn’t cause excessive line loss.
- When approaching an obstacle in the suction or discharge line, go around the obstacle instead of over it. Going over it creates an air pocket. See Figure A13.
- Where practical, slope the piping so no air or liquid pockets will be formed. Air pockets in the suction line make it hard for the pump to prime.
- For a suction line with a long horizontal run, keep the horizontal portion below the liquid level if possible. This keeps the pipe full of liquid and reduces the amount of air the pump must evacuate at startup. This is most helpful when there is no foot valve. See Figure A14.
- When piping a hot or cold system (liquid being handled is at a temperature different from the air surrounding the pump), be sure allowance is made for expansion and contraction of the piping. Loops, expansion joints, or unsecured (this does not mean unsupported) runs should be used so the pump casing is not distorted.
- STRAINER – Itis always good practice to consider a strainer on the suction side of a positive displacement pump. The strainer will keep foreign objects from going into the pump. Without a strainer objects can lock the pump, and damage the internals and drive. The strainer basket mesh or perforation size should be big enough so that it does not cause excessive pressure drop, but it should be fine enough to protect the pump. When in doubt as to the proper size, check with the manufacturer, giving pipe size, flow rate, and viscosity involved. Provision should be made for cleaning the strainer. If the pump operates continuously, a bypass should be built around the strainer, or two strainers should be put in parallel with proper valving so they can be isolated for cleaning. Use of a strainer is particularly important at start up to help clean the ‘system of weld beads, pipe scale, and other foreign objects. For additional information, refer to TSM 640.
- If the pump is not equipped with a relief valve, consideration should be given to mounting one in the discharge line. Refer to discussion on pressure protection under item 5 in General Installation Notes section.
- The pump should not be used to support the piping. The weight of the piping should be carried by hangers, supports, stands, etc.
- When fastening the piping to the pump it should not be necessary to impose any strain on the pump casing. “Springing” or “drawing” the piping up to the pump will cause distortion, possible misalignment, and probable rapid wear of the pump. Do not use the pump to correct errors in piping layout or assembly.
- All joints of the piping system should be tight; pipe sealer will help assure leak-free threaded joints. Leaks in the suction line permitting air to be drawn in may cause a noisy pump or a reduction in capagity. It is not recommended to use PTFE tape on NPT ports as a pipe sealer. This action can result in cracks in the pump.
- ALIGNMENT – Check the alignment of the drive after the piping is hooked up. As a final check on pump alignment, remove the head of the pump and with a feeler gauge determine if there is clearance all the way around between the rotor and casing. Because of manufacturing tolerances, bushing clearances, etc., the rotor may not be centered in the casing, but it should not drag; dragging would indicate unit misalignment or casing distortion from piping strain. Making this check is most desirable on installations involving Q, M and N size general purpose pumps.
- The auxiliary piping hooked to jackets, glands, etc. for heating, cooling, quenching, or for other purposes should receive the same attention as the piping handling the pumped liquid.
15. Provide a pressure relief device in any part of a pump and piping system that can be valved off and, thus, completely isolated. This is particularly important:
a. When handling a cold liquid such as refrigeration ammonia that can warm up to ambient temperatures when the pump is shut off.
b. When handling a liquid such as asphalt or molasses that has to be heated before it can be pumped.
The rise in temperature causes the liquid to expand; if there is no provision for pressure relief in the closed off section, there is a chance that the pump or piping will rupture.
START UP
Before starting the pump, check the following:
-
Are there vacuum and pressure gauges on or near the pump? These gauges are the quickest and most accurate way of finding out what is happening in the pump.
-
Check alignment – See suggestions in the Alignment section of this manual.
-
Check piping to be sure there is no strain on the pump casing.
-
Rotate the pump shaft by hand to be sure it turns freely. MAKE SURE THE PUMP DRIVER IS LOCKED OUT OR CANNOT BE ENERGIZED BEFORE DOING THIS.
-
Jog motor to be sure it is turning in the right direction; refer to discussion on pump rotation under item 4 in General Installation Notes section.
-
Check any relief valves to be sure they are installed correctly. Refer to discussion on relief valves in General Installation Notes section.
-
Check suction piping to be sure:
a. It is all connected and tight
b. Valves are open
c. End of pipe is below liquid level -
Check discharge piping to be sure:
a. It is all connected and tight
b. Valves are open
c. There is a place for the liquid to go -
Lubricate any grease fitting on the pump using a #2 NLGI grease. Check any gear reducer, motor, coupling, etc. for instructions and lubricate as recommended by the manufacturer. See Engineering Service Bulletin ESB-515 at the end of the Appendix for Viking standard grease types to check compatibility.
-
For packed pumps, loosen packing gland nuts so gland can be moved slightly by hand. Adjust gland to reduce leakage only after pump has run long enough to reach constant temperature. Packing should weep a little to keep it cool and lubricated.
-
Do not use the Viking pump to flush, pressure test or prove the system with water. Either remove the pump or run piping around it while flushing or testing. Pumping water, dirty or otherwise, can do more damage in a few minutes than months of normal service.
-
Check to be sure all guards are in place.
-
Check the pump to be sure it is heated to operating temperature (if jacketed or heat traced).
If the pump begins to deliver liquid within 60 seconds, it can continue to be
operated. If liquid is not leaving the discharge port, stop the pump. Running
the pump longer than one minute without liquid inside it can damage the pump.
Review the steps just outlined, consider what the suction and discharge gauges
indicate, and see Troubleshooting section. If everything appears to be in
order, put some liquid in the pump. This will help it prime.
The pump can be restarted. If nothing is flowing within two minutes, stop the
pump. The pump is not a compressor; it will not build up much air pressure. It
may be necessary to vent the discharge line until liquid begins to flow.
If the pump still does not deliver flow, the cause may be one or more of the
following:
- Suction line air leaks. Vacuum gauge reading should help determine if this is the problem.
- End of suction pipe not submerged deep enough in liquid.
- Suction lift is too great or the suction piping is too small.
- Liquid is vaporizing in the suction line before it gets to the pump.
If after consideration of these points it still does not pump, review again all points under START UP. Read through Troubleshooting in this manual and try again. If it still does not pump, contact your Viking Pump® representative.
TROUBLESHOOTING
A Viking pump that is properly installed and maintained will give long and
satisfactory performance.
NOTE: Before making any pump adjustment or opening the pump liquid
chamber in any manner, make sure that:
- Any pressure in the pumping chamber has been vented through the suction or discharge lines or other openings provided for this purpose.
- The driver has been “locked out” so that it cannot inadvertently be started while work is being done on the pump.
- The pump has been allowed to cool down to the point where there is no chance of anyone being burned.
If trouble does develop, one of the first steps toward finding the difficulty
is to install a vacuum gauge in the suction port and a pressure gauge in the
discharge port. Readings on these gauges often will give a clue as to where to
start looking for the trouble.
VACUUM GAUGE – SUCTION PORT
-
High reading would indicate:
a. Suction line is blocked by a stuck foot valve, stuck gate valve, or plugged strainer.
b. Liquid is too viscous to flow through the piping.
c. Lifts too high.
d. Line’s too small. -
Low reading would indicate:
a. Airlink in suction line.
b. End of pipe is not in liquid.
c. Pump’s worn.
d. Pump’s dry – should be primed. -
Fluttering, jumping, or erratic reading:
a. Liquid is vaporizing.
b. Liquid is coming to pump in slugs, possibly an air leak, insufficient liquid above the end of the suction pipe.
c. Vibrating from cavitation, misalignment, or damaged parts.
PRESSURE GAUGE – DISCHARGE PORT
-
High reading would indicate:
a. High viscosity, small diameter discharge line or long discharge line.
b. Gate valve is partially closed.
c. Filter is plugged.
d. Vertical head did not consider a high specific gravity liquid.
e. Line is partially plugged from build up on inside of pipe.
f. Liquid in the pipe is not up to temperature.
g. Liquid in the pipe has undergone a chemical reaction and has solidified.
h. Relief valve is set too high. -
Low reading would indicate:
a. Relief valve is set too low.
b. Relief valve poppet is not seating properly.
c. Bypass around the pump is partially open.
d. Too much extra clearance.
e. Pump is worn. -
Fluttering, jumping, or erratic reading:
a. Cavitation.
b. Liquid is coming to the pump in slugs.
c. Air leak is in the suction line.
d. Vibrating from misalignment or mechanical problems.
Some of the following may also help pinpoint the problem:
A. Pump does not pump.
- Pump has lost its prime due to air leak, low level in tank, foot valve stuck.
- Suction lift is too high.
- Rotating in wrong direction.
- Motor does not come up to speed.
- Suction and discharge valves not open.
- Strainer is clogged.
- Bypass valve open, relief valve set too low, relief valve poppet stuck open.
- Pump is worn out.
- Any changes in the liquid system or operation that would help explain the trouble, e.g. new source of supply, added more lines, inexperienced operators, etc.
- Too much end clearance.
- Head position is incorrect. See Figure A3.
- Temperature changes either in the liquid or environment.
- Mag Drive pumps ONLY: The magnetic coupling is decoupling. Changes in application (temperature, pressure, viscosity, etc.) may require torque beyond coupling capabilities.
B. Pump starts, then loses its prime.
- Supply tank is empty.
- Liquid is vaporizing in the suction line.
- Air leaks or air pockets in the suction line; leaking air through packing or mechanical seal.
- Pump is worn out.
c. Pump is noisy.
- Pump is being starved (heavy liquid cannot get to pump fast enough). Increase suction pipe size or reduce length.
- Pump is cavitating (liquid vaporizing in the suction line). Increase suction pipe size or reduce length. If pump is above the liquid, raise the liquid level closer to the pump. If the liquid is above the pump, increase the head of liquid.
- Check alignment.
- May have a bent shaft or rotor tooth. Straighten or replace.
- Relief valve chatter. Increase pressure setting.
- May have to anchor base or piping to eliminate or reduce vibration.
- May be a foreign object trying to get into the pump through the suction port.
- Mag Drive pumps ONLY: The magnetic coupling has decoupled. Shut off and let cool, then restart.
D. Pump not up to capacity.
- Starving or cavitating. Increase suction pipe size or reduce length.
- Strainer partially clogged.
- Air leak in suction piping or along pump shaft.
- Running too slowly. Check the motor is running at the correct speed and that it is wired correctly.
- Bypass line around pump partially open.
- Relief valve set too low unstuck open. Pump is worn out:
- Too much end clearance.
- Head position incorrect. See Figure A3.
E. Pump takes too much power.
- Running too fast. Verify the motor speed, reducer ratio, sheave size, and other drive components are correct for the application?
- The liquid is too viscous for the size of the unit. Heat the liquid to reduce viscosity, increase the pipe size, slow down the pump, or use a larger motor.
- Discharge pressure higher than calculated. Verify with a pressure gauge. Increase size or reduce length of pipe, reduce speed (capacity), or get bigger motor.
- Packing gland drawn down too tight.
- Pump misaligned.
- Extra clearance on pumping elements may not be sufficient for operating conditions. Check parts for evidence of drag or contact in pump and increase clearance where necessary.
- System pressure relief valve is set too high.
- Bushings have locked to shaft or pin, or the liquid has set up in the pump.
F. Rapid Wear.
On most applications the pump will operate for many months or years before it
gradually loses its ability to deliver capacity or pressure. Examination of
such a pump would show a smooth wear pattern on all parts. Rapid wear,
occurring in a few minutes, hours or days, shows up as heavy grooving,
galling, twisting, breaking or similar severe signs of trouble. See Rapid Wear
Table.
RAPID WEAR
RAPID WEAR TABLE
CAUSE | EVIDENCE | POSSIBLE SOLUTION |
---|---|---|
1 | ABRASIVES | Gouges or marks made by large, hard particles; a |
rapid wearing away of bushings from very small abrasives; or anything in
between.| Flush the system with the pump removed. Install strainer in suction
line. Most abrasive objects and particulate is removed after a few cycles (or
days) of flushing.
2| CORROSION| Rust, pitting or metal appears to be “eaten” away.|
Check the Viking General Catalog Liquid List for materials of construction
recommendation. Consider whether all of the materials used in pump
construction were attacked; consider other materials used in the system to
determine how they resisted the liquid. Check to see whether or not the liquid
has been contaminated to make it more corrosive than anticipated.
3| EXCEEDING OPERATING LIMITS| Noisy operation, broken
bushings, twisted shaft, parts show evidence of high heat (discoloration).|
Review General Catalog for operating limits on particular model involved.
4| INSUFFICIENT EXTRA CLEARANCE| Pump may stall. Evidence
of heavy contact between end of rotor teeth and head or other parts.| Increase
end clearance and/ or contact your Viking Pump® representative with details of
the application, so that information regarding proper extra clearance may be
provided.
5| LACK OF| Noisy bearings, localized heating at bearings or lip
seal, smoke, rapid bushing wear.| Be sure all grease fittings are greased
before starting, and instructions for lubrication of drive equipment are
followed; consider use of auxiliary lubricating equipment.
6| MISALIGNMENT| Wear on only one part of a surface, e.g., one side
of the casing, one side of the packing gland, only a portion of the face of
the head.| Double check alignment of drive equipment and piping. Check the
alignment under conditions as close to operating conditions as possible.
7| RUN DRY| Pump stalls because parts have uneven expansion caused
by frictional heat; galling between surfaces having relative motion; seal
seats and idler pins changing color because of high heat.| Be sure there is
liquid in the system at the time of start up. Provide some kind of automatic
alarm or shut-off if supply tank runs dry.
PREVENTATIVE MAINTENANCE
Performing a few preventative maintenance procedures will extend the life of your pump and reduce the overall cost of ownership.
A. Lubrication – Grease all grease fittings after every 500 hours of
operation. If service is severe, grease more often. Do it gently with a hand
gun until the grease exiting the lip seal or relief plug is similar in
consistency and color to the new grease.
Use a NLGI #2 grease for normal applications. See ESB-515 at the end of the
Appendix for Viking standard grease types to check compatibility. For hot or
cold applications, use appropriate grease. O-Pro® seals should also be greased
every 500 hours of operation with a lubricating fluid compatible with the
process fluid.
B. Packing Adjustment – Occasional packing adjustment may be required to keep
leakage to a slight weep. If impossible to reduce leakage by gentle
tightening, replace packing or use different type. Refer to Technical Service
Manual on particular model series for details on repacking.
C. End Clearance Adjustment – After long service, the running clearance
between the end of the rotor teeth and the head may have increased through
wear. This wear may cause a loss of capacity or pressure. Resetting end
clearance will normally improve pump performance. Refer to TSM on particular
model series for procedure on adjusting end clearance for pump involved.
D. Examine Internal Parts – Periodically remove the head, examine idler and
bushing and head and pin for wear. Replacing a relatively inexpensive idler
bushing and idler pin after only moderate wear will eliminate the need to
replace more expensive parts at a later date. Refer o TSM on particular model
series for procedure in removing head of the pump. Be sure idler does not
slide off the idler pin as the head is removed. If it does slide off the idler
can cause personal injury or damage the part.
E. Cleaning the Pump – A clean pump is easier to inspect, lubricate, adjust,
and runs cooler.
F. Storage – If pump is to be stored or not used for six months or more, pump
must be drained, and a light coat of non-detergent SAE 30 weight oil must be
applied to all internal pump parts. Lubricate fittings and apply grease to
pump shaft extension. Viking suggests rotating pump shaft by hand one complete
revolution every 30 days to circulate the oil. Retighten all gasketed joints
before using the pump.
DO’S & DON’ TS
Do’s and Don’ts for installation, operation, and maintenance of Viking pumps
to assure safe, long, trouble-free operation.
INSTALLATION
- DO install pump as close to supply tank as possible.
- DO leave working space around the pumping unit.
- DO use large, short, and straight suction piping.
- DO install a strainer in the suction line.
- DO double check alignment after the unit is mounted and piping is hooked up.
- DO provide a pressure relief valve for the discharge side of the pump.
- DO cut out the center of gaskets used as port covers on flanged port pumps.
- DO record pump model number and serial number and file for future reference.
OPERATION
- DON’T run pump at speeds faster than shown in the catalog for your model.
- DON’T require pump to develop pressures higher than those shown in the catalog for your model.
- DON’T operate pumps at temperatures above or below limits shown in the catalog for your pump.
- DON’T operate pumps without all guards being in place.
- DON’T operate pump without a relief valve on the pump or in the discharge piping. Be sure valve is mounted and set correctly.
- DON’’T exceed catalog limits for temperature and pressures of fluids in jacketed areas of pump.
- DON’T use the pump in a system which includes a steam, air, or vapor blow or purge without provision for over- speed shutdown, in case the pump starts to act as a turbine and over-speeds the drive.
- DON’T operate the pump with all of the liquid bypassing through a pump mounted internal type relief valve, or without any flow of liquid going through the pump for more than a couple of minutes. Operation under either of these conditions may result in a heat build-up in the pump, which could cause hazardous conditions or happenings.
MAINTENANCE
- DO make sure any pump that has residual system pressure in it, or that has handled high vapor pressure liquids, such as LP-gas, ammonia, Freons, etc., has been vented through the suction or discharge lines or other openings provided for this purpose.
- DO make sure that if the pump is still hooked to the driver while maintenance is being performed that the driver has been “locked out”, so that it cannot be inadvertently started while work is being done on the pump.
- DO make sure any pump that has handled a corrosive, flammable, hot, or toxic liquid has been drained, flushed, vented and/or cooled before it is disassembled.
- DO remember that a few simple preventative maintenance procedures such as periodic lubrication, adjustment of end clearance, examination of internal parts, etc., will extend the service life of your pump.
- DO obtain, read and keep maintenance instructions furnished with your pump.
- DO have spare parts, pumps or standby units available, particularly if the pump is an essential part of a key operation or process.
- DON’T drop parts during disassembly, e.g., idler can slip from the pin as the head is removed from the pump. It may cause personal injury or damage the part.
- DON’T stick fingers in the ports of a pump. Serious injury may result.
- DON’T spin the idler on the idler pin. Fingers may be jammed between teeth and crescent.
BSB-515
Effective 25-July-19
LUBRICATION OF VIKING PUMPS
Usage of Grease| General Description of Grease Used by
Viking| Viking Recommended Supplier
---|---|---
Grease used for anti-friction bearings, sleeve bearings and lantern rings|
Premium EP, Multi-purpose polyurea base grease| Any NLGI Grade 2 premium
quality, multi-purpose, polyurea grease
Grease used for bracket bushing when seal is behind rotor| Petrolatum| Chevron
Petrolatum Snow White
Grease used for O-Pro® Barrier / Guard Seals| Edible Grease, aluminum complex|
Chevron FM ALC EP 0, 1, 2
Grease used for O-Pro® Cartridge Seals| High Temperature Grease| Misty Ultra
High Temp Super film G00735
Lubricate each grease fitting every 500 hours of operation or every six
months, whichever occurs first. If service is severe, grease more often. Be
sure the grease is compatible with the grease used by Viking. Grease used for
the bracket bushing and O-Pro® Seal should be compatible with the liquid being
pumped.
Reservoir on Ammonia Pumps: The Series 4924A ammonia pumps are shipped without
oil in the reservoir. Before start-up, fill the reservoir with one pint of
Light Refrigeration Oil that is compatible with the Neoprene seal and with a
maximum viscosity of 15,000 SSU at operating temperature. Drain and refill the
reservoir after the first 200 hours of operation and every 1000. hours
thereafter. Refer to Technical Service Manual TSM 1467. Pumping Chamber of
Stainless Pumps: All internal parts are coated with test fluid to avoid
galling when the pump is first installed. Be sure the pump is kept full of
liquid when in operation to prevent damage to the pump.
PUBRICATION OF VIKING REDUCERS
Viking gear reducers,
“A”, ‘B, “C” sizes use SAE 30 oil above 32°F and SAE 10W gel breviary I8
- A Size: 3/8 PT. (6 0z)
- B Size: 122PT. (80z)
- C Size: 2-1/4 PT. (36 oz.)
Viking gear reducers are shipped less oil. Before start-up, fill to proper
level with quantity and type of oil shown in box at left. After first 100
hours of operation, drain and refill with new lubricant.
Check lubricant level every 2000 hours or every six months. Once each year,
drain and refill.
LUBRICATION OF VIKING ASSOCIATIVE EQUIPMENT
Check any motor, coupling, gear reducer or other drive equipment for
manufacturer’s instructions and lubricate as recommended.
VIKING PUMP
WARRANTY
Viking pumps, strainers and reducers are warranted to be free of defects in
material and workmanship under normal conditions of use and service. The
warranty period varies by type of product. A Viking product that fails during
its warranty period under normal conditions of use and service due to a defect
in material or workmanship will be repaired or replaced by Viking. At Viking’s
sole option, Viking may refund (in cash or by credit) the purchase price paid
to it for a Viking product less a reasonable allowance for the period of use)
in lieu of repair or replacement of such Viking product. Viking’s warranty is
subject to certain restrictions, limitations, exclusions and exceptions. A
complete copy of Viking’s warranty, including warranty periods and applicable
restrictions, limitations, exclusions and exceptions, is posted on Viking’s
website
(www.vikingpump.com/warrantyinformation).
A complete copy of the warranty may also be obtained by contacting Viking,
through regular mail at Viking Pump, Inc., 406 State Street, Cedar Falls,
lower 50613, USA.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE AND EXCLUSIVE WARRANTY AND IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO, ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
NON-INFRINGEMENT, ALL OF WHICH OTHER WARRANTIES ARE EXPRESSLY EXCLUDED.
THE RIGHTS AND REMEDIES UNDER THIS WARRANTY ARE AND SHALL BE THE SOLE AND
EXCLUSIVE RIGHTS AND REMEDIES AGAINST VIKING. EXCEPT FOR THE SPECIFIC
LIABILITIES AND OBLIGATIONS PROVIDED UNDER THIS – ARRANTY, VIKING SHALL HAVE
NO LIABILITY. OR OBLIGATION WITH RESPECT TO ANY PRODUCT CLAIMED TO BE
DEFECTIVE IN ANY MANNER.
UNDER NO CIRCUMSTANCES SHALL VIKING BE LIABLE UNDER THIS WARRANTY OR OTHERWISE
FOR SPECIAL, INCIDENTAL, INDIRECT, CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY
KIND, INCLUDING, BUT NOT LIMITED TO, LOST OR UNREALIZED SALES, REVENUES,
PROFITS, INCOME, COST SAVINGS OR BUSINESS, LOST OR UNREALIZED CONTRACTS, LOSS
OF GOODWILL, DAMAGE TO REPUTATION, LOSS OF PROPERTY, LOSS OF INFORMATION OR
DATA, LOSS OF PRODUCTION, DOWNTIME, OR INCREASED COSTS, IN CONNECTION WITHANY
PRODUCT, EVEN IF VIKING HAS BEEN ADVISED OR PLACED ON NOTICE OF THE
POSSIBILITY OF SUCH DAMAGES AND NOTWITHSTANDING THE FAILURE OF
ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
© 2022 Viking Pump, Inc. * Cedar Falls, 1A
© 10/2022 Viking Pump, Inc. Al rights reserved
Read User Manual Online (PDF format)