telcoma automations RAP-6 Electromechanical Barrier Instruction Manual

June 12, 2024
telcoma automations

telcoma automations Logo RAP-6
ISTRAP6
V. 04.2008
telcoma automations RAP 6 Electromechanical Barrier
ELECTROMECHANICAL BARRIER
INSTRUCTION HANDBOOK AND SPARE PARTS CATALOGUE
THIS HANDBOOK IS INTENDED FOR QUALIFIED TECHNICAL INSTALLERS

FEATURES

RAP-6 is an electromechanical barrier designed for use at entrances to: car parks, multi-storey parks, factories, public administration buildings, hospitals, apartment blocks, etc..
It consists of a box which houses the gearmotor and the electronic control unit.
Movement is irreversible with the possibility of manual release.

Optional accessories
Mobile fence-type frame Jointed support foot
Rectangular bar L = m6.25
Round-profile bar L=6.25m
Fixed bar rest

TECHNICAL DATA U.M. RAP-6
Line voltage Va c 230
Motor power supply Vdc 24
Max. input curren A 1
Max. input power VA 200
Nominal torque Nm 280
Opening time sec. 7-8
Movement irreversible – irreversibel – onomkeerbaar
Max. angle of rotation ° 90
Operating temperature °C -10+70
Motor grease TS-10
Working intermittence % 50
Max. bar length m 6.25
Weight Kg 55

OVERALL MEASUREMENTS

telcoma automations RAP 6 Electromechanical Barrier - OVERALL
MEASUREMENTS

GENERAL LAYOUT

1. Photocells
2 Fixed rest
3. Aluminium bar
4. Diamond-shape reflectors
5. Key selector
6. Fence frame| 7. RAP- 6
8. Blinking light
9. Antenna
10. Differential switch
11. On/off switch
12. Power line
---|---

GENERAL ASSEMBLY

telcoma automations RAP 6 Electromechanical Barrier - OVERALL
MEASUREMENTS

PRELIMINARY CHECKS AND INSTALLATION OF BASE PLATE IN THE GROUND
Before installing, it is advisable to check that the ground where the barrier is to be installed is solid and suitable so that correct operation is not compromised.
If the RAP-6 rests on a solid cement base, it may fixed directly to the ground with 4 screw anchors dia.12 (fig. 2) otherwise fixing may be done using the plate. In this case, proceed as follows:

  1. Dig a foundation hole, according to the measurements of the foundation plate.
  2. Place ducts in the hole for the supply and external connection cables to pass through.
  3. Assemble the plate-rag bolts (fig. 3).
  4. Bury the ducts and foundation plate in the cement and check that they are horizontal.
  5. Unscrew the nuts from the 4 rag bolts after the cement has set.
  6. Position the RAP-6 on the plate, fixing it with the 4 washers and 4 nuts provided.

telcoma automations RAP 6 Electromechanical Barrier -
PRELIMINARY

INSTALLATION OF THE BARRIER

Given the weight of the barrier, it should be handled by several persons.
Unpack as shown in figure.
A 3 x 1.5 power supply cable is recommended for electrical connection.

  1. Install the barrier as described above.
  2. Fix the bar to the barrier.
  3. Put the barrier to the “bar down” position.
  4. Make the necessary electrical connections.
  5. Turn on the power supply.
  6. Adjust the limit stop screws.
  7. Test operation of the installation.
  8. Select the required operating modes on the electronic control unit.

telcoma automations RAP 6 Electromechanical Barrier -
BARRIER

LEFT-HAND INSTALLATION

The RAP-4 comes supplied for right-hand use and in the “bar-up” position; the internal counterweight spring is consequently not loaded. The expression “right-hand use” means that the box is assembled to the right of the aperture (seen from inside). (fig. 1).
For left-hand use of the barrier, move the spring unit to the opposite side (as in fig. 4).
Proceed as follows for the lefthand use of the barrier:

  1. Reduce the load of the spring to zero by means of the spring adjustment screw. (fig. 5)
  2. Disconnect the spring from the lower connector. (fig. 6)
  3. Extract the spring unit from the barrier unscrewing the screw on the spring equalizing rocker arm (fig. 7)
  4. Extract the spring equalizing rocker arm from the splined shaft, turn it through approximately 90°, insert it into the shaft again and secure it. (fig. 8)
  5. From behind the barrier, check that the rotation of the plate has an angle of 90° with the shaft (fig. 9); if necessary check the position of the spring equalizing rocker arm again.
  6. Make sure that the barrier is in the bar up position.
  7. Fit the spring unit on the spring equalizing rocker arm, connect the spring to the lower connector (fig. 10), and tension the spring by means of the spring adjustment screw to guarantee that the bar movement is sufficiently assisted.
  8. Invert the motor wires: open and close; (refer to “terminal boards” for the electronic control unit).

telcoma automations RAP 6 Electromechanical Barrier - INSTALLATION
2

BARRIER RELEASE
To release the barrier, turn the release wheel in a clockwise direction as far as it will go (Fig.11).
To restore the gearmotor, turn the release wheel in an anti-clockwise direction as far as it will go.

telcoma automations RAP 6 Electromechanical Barrier - BARRIER
RELEASE

BATTERIES
There is a location for two 12V 1.9 Ah dry batteries inside the control box.
Use the supplied metal clamps and screws to secure the batteries to the lid of the control unit as illustrated in the diagram.

telcoma automations RAP 6 Electromechanical Barrier -
BARRIERS

ELECTRICAL CONNECTION
Refer to “terminal boards” in the electronic control unit handbook.

TROUBLESHOOTING

  1. The barrier does not activate. The electric motor does not work and there is consequently no noise or vibration.
    a. Check that the electronic control unit is powered correctly.
    b. Check that the fuses are intact.
    c. Check with the help of suitable diagnostic instruments that the electronic control unit functions correctly.
    d. Make sure that the barrier is receiving power 230Vac – 10%.

  2. The barrier activates but the bar does not move.
    a. Check that the thrust of the spring has been correctly adjusted.
    b. Check that bar movement is not obstructed.
    c. Check that the RAP-6 has not been released.

IMPORTANT RECOMMENDATIONS CONCERNING INSTALLATION

–  Only qualified personnel having the legal requirements must install the automation according to the principles of good workmanship and in conformity with the machinery directive 98/37/CE and standards EN 12453 and EN 12445.
– Check that the existing structures (posts, hinges, leaves) are stable in relation to the forces developed by the motor.
– Check that suitably robust limit stops have been installed for end of gate opening and closing.
– Check the state of the cables that are already present in the system.
– Analyse the hazards connected with the automation system and adopt the necessary safety and signalling devices accordingly.
– Install the commands (e.g. the key selector) so that the user is not placed in a hazardous area when using them.
– Upon completion of the installation, test the safety, signalling and release devices of the automation system several times.
– Apply the CE label or plate with information regarding the hazards and identification data on the automation.
– Give the end user the instructions for use, the safety recommendations and the CE declaration of conformity.
– Ensure that the user has understood the correct automatic, manual and emergency operation of the automation system.
– Inform the user in writing (e.g. in the instructions for use) of any unprotected residual risks and of foreseeable misuse.
– Inform the user in writing (in the use instructions for example):

  • Of possible non secluded residual risks and of foreseeable improper use.
  • To disconnect the power supply when cleaning the area that is automated or when performing small maintenance operations (e.g.: Repainting).
  • To frequently control that no visible damage has occurred to the automation, and to inform the installer immediately if damage is noticed.
  • Not to allow children to play in the vicinity of the automation.
    – Prepare a maintenance schedule for the automation installation (at least once every 6 months for the safety devices), recording the work carried out in a special book.

RAP-6

telcoma automations RAP 6 Electromechanical Barrier -
operations

SPAREPARTS CATALOGUE

Nr. Cod. RAP-6spareparts
1 VTM100X0160CZCE M10X16UNI5931TCCEGALV.SCREW.
2 RON10X00PZ D.10UNI6592GALV.WASHER
3 SUP0031V RAP6PAINTEDBARSUPPORT
3a SUP0030V RAP6D.90PAINTEDBARSUPPORT
4 VTM120X0250SZCE M12X25UNI5933TPSEGALV.SCREW
5 GR08X008EPZ M8X8UNI5923GALV.DOWEL
6 PIASUPASTAB5Z RAP6GALV.BARSUPPORTPLATE
7 ARMB5V RAP6PAINTEDCABINET
8* MISW30X16L 30X16MICROSWITCHWITHLEVER
9* VTT030X0150CZC M3X15TRI-LOBEDTCGALV.SCREW
10 VTM120X0200EZ M12X20UNI5739TEGALV.SCREW
11 9224000100 M4X10UNI5931TCCEGALV.SCREW
12 SEG38EF D.38UNI7435SNAPRING
13* VTM060X0200EZ M6X20UNI5739TEGALV.SCREW
14* DA06ZL M6ALTOGALV.NUT
15 BIB5Z RAP6GALV.SPRINGEQUALIZINGROCKERBAOILGUARD
16 PA60X80X10BA RAP6ASS.KNOB&WHEEL
17 MAN0010 PAINTEDDOORFORBR6CABINET
18 PORB6V BR6WIREDMICRO-SWFC
19* CAB0002 SWING/IR.RELEASECAP
20 TAP0005 SM-SML-TECNOLOCK
21 SER0006 D.25UNI7435SNAPRING
22 SEG25EF BR6CAMSUPPORTPIN
23 PE0020 BR6SPRINGTIGHTENINGCAM
24 9262008900 D.15X42X136302BEARING
25 CUSC6302B D.42UNI7437SNAPRING
26 SEG42IF BR6CAMSPACER
27 DIS0019 BR6GALV.SPRINGADJUSTMENTSCREW
28 VTREGMOLLA BR6DRAWSPRING
29 MO0022 RAP6CE.CCTx124VdcMOTOR
30 CECRAP6 M3THREADEDSPACER
31 DIS0024 M3X6uni7985TCGALV.SCREW
32 VTM030X0060SZC D.6X24DIN9021GALV.WASHER
33 RON06X24PZ TELCOMA274X217X110PLASTBOX+4SCREWS
34 SPTEL M6X50CUP-HEADEDSCREW
35 9224008100 230/22V150VATOROIDFORCE.C
36 TRA230V150VATOR M2.9X13UNI6954NICKEL-PLATEDSCREW
37 VTA029X0013CNC RAP4GALV.TOROIDPLATE
38 PIATOR M4X8UNI8113TRI-LOBEDTPSGALV.SCREW
39 VTT040X0080SZC GW50428F20XSEPARE’CABLECLIP
40 PASF20 RAP3/BR6GALV.FIXINGTIE
41 9182005900 D.14UNI6592GALV.WASHER
42 RON14X00PZ M14UNI5588GALV.NUT
43 DA14Z0 BR6GALV.FIXINGPLATE
44 9182004700 SWINGD.16X1COVERPLUG
45 TAP0037 60X80X10
46 VTM120X0400EG M12X40UNI5739TESCREW
47 DA12Z0 M12UNI6/S5588GALV.NUT

ITEMS8;9;13;14and19WITH“T124”CONTROL UNITONLY

RAP-6 GEARMOTOR

telcoma automations RAP 6 Electromechanical Barrier - operations
2

Nr. Cod. RAP-6 GEARMOTOR
48 CUSC60092RSB BEARING D.45X75X16 6009 2RS
49 DA08Z0 M8 UNI 6/S 5588-8 GALV. NUT
50 BR0013 VSF RAP6 BUSHING
51 PRESSPG11M PG 11 MAXIBLOCK CABLE CLAMP
52 CORD900 ROCK UPPER CASING
53 RONO3X07PP3 D.3 D.E.7 H:3 PLASTIC WASHER
54 ENCODERRAP RAP MAGNETIC ENCODER
55 VTT030X0100CZC M3X10 DIN 7500-C-H TRI-LOBED GALV. SCREW
56 DIS0023 24V RAP6 MOTOR SPACER
57 VTM040X0160E1 M4X16 ISO 4017 TE A2 STAINLESS STEEL SCREW
58 MAG4POLI 4+4 POLES RE8 PLASTOMAGNET
59 SUP0026 TECNO ENCODER ROTATING SUPPORT H=10.3
60 MOT0026 MOT. RAP6 2800 rpm 24Vdc E VSF
61 COREB5 RAP6 LOWER CASING
62 TAP0020 ROCK D.10X10 RUBBER PLUG
63 OR253M59X03M53 D.253.59X3.53 N.41000 O.RING
64 SPICO4X025G 4X25 DIN6325 CYLINDRICAL PIN
65 9336000200 ROCK DR.SHA. RED. GEAR
66 ALBSB5R RAP 6 SPLINED SHAFT
67 PE0028 RAP6 GAL. RELEASE PIN
68 COR0021 RAP6 Z30 M3 HELICAL GEAR
69 LI12X08X063 12X8X63 UNI 6604/A TONGUE
70 MOS2010X38 SM 10X38 RELEASE SPRING
71 CUSC62052RSB D.25X52X15 6205 2RS BEARING
72 9230002200 24V ROCK WORM
73 FONARBS ROLLER CASE BASE
74 ARHK4516B5 45X52X16 ROLLER CASE
75 VTT060X0200CICE M6X20 TCCE TRI-LOBED S. STEEL SCREW
76 SEG45EF D.45 UNI 7435 SNAP RIN

DISPOSAL

This product is made up of various components that could contain pollutants. Dispose of properly!
Make enquiries concerning the recycling or disposal of the product, complying with the local laws in force.

PROFESSIONAL GARAGE DOOR AND GATE OPERATORS

DECLARATION CE
The manufacturer:
Telcoma sd
Via L. Manzoni, 11 31015 – Z.1. Campidui – Conegliano (TV)
ITALY
DECLARES that the products

GEAR MOTOR DRIVE UNIT “RAP6”
are however conforming to the only applicable parts of this directive;
Directive 73/23/EEC, Directive 93/68/EEC Low Voltage
Directive 89/336/EEC, Directive 92/31/EEC
Directive 92/31/EEC Electromagnetic
Compatibility
The following parts/clauses of the harmonised regulations have been applied:
EN60335-1, EN60204-1, EN 61000-6-3, EN61000-6-1
and for the only applicable parts the norms
EN12445 e EN12453

DECLARATION BY THE MANUFACTURER
(Directive 98/37/EEC, Attachment II, Part B)
Have been constructed to be incorporated in a machine or to be assembled with other machinery to construct a machine as set out in Directive 98/37/EEC
The manufacturer furthermore declares that it is not permitted to operate the products until the machine in which they will be incorporated or of which they will become components has been identified and its conformity with the provisions set out in Directive 98/37/EEC and the national legislation has been declared, i.e. until the products as set forth in this declaration form a single unit with the final machine.

Conegliano, li 03/06/2006
Legal representative Augusto Silvio Brunello

Notes…..

WARRANTY

This warranty covers any failure and/or malfunctioning due to manifacturing faults and/or bad workmanship.
The warranty is automatically invalidated if the product is tempered with or used incorrectly.
During the warranty period, Telcoma srl undertakes to repair and/or replace faulty parts provided they have not been temperd with.
The call-out charge as well as the expenses for dasasembley, packing and transport of the product for repair or replacement shall be charged entirely to the customer.

telcoma automations Logo Telcoma srl – Via L. Manzoni, 11 – Z.I. Campidui
31015 Conegliano – (TV) Italy – Tel. +39 0438-451099
Fax +39 0438-451102 – Part. IVA 00809520265
http://www.telcoma.it E-mail: info@telcoma.it

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals