PLANET IECS-1116-DI Industrial EtherCAT Slave I-O Module with Isolated 16-ch Digital Input-Output User Manual

June 12, 2024
PLANET

Industrial EtherCAT Slave I/O Module
with Isolated 16-ch Digital Input/Output IECS-1116-DI/IECS-1116-DO
User’s Manual

Package Contents

Thank you for purchasing PLANET Industrial EtherCAT Slave I/O Module with Isolated 16-ch Digital Input/Output, IECS-1116-DI or IECS- 1116-DO. In the following sections, the term “Industrial EtherCAT Slave I/O Module” means the IECS-1116-DO or IECS-1116-DO. Open the box of the Industrial EtherCAT Slave I/O Module and carefully unpack it. The box should contain the following items:

Industrial EtherCAT Slave I/O Module x 1

|

User’s Manual x 1

---|---
|
Wall-mount Kit

If any of these are missing or damaged, please contact your dealer immediately; if possible, retain the carton including the original packing material, and use them again to repack the product in case there is a need to return it to us for repair.

Product Features

  • Built-in isolated 16 digital inputs (IECS-1116-DI)
  • Built-in isolated 16 digital outputs (IECS-1116-DO)
  • 2 x RJ45 bus interface
  • LED indicators for the input status
  • Removable terminal block connector
  • 9 ~ 48 VDC wide input voltage range
  • 700mA/ch high output current (IECS-1116-DO)
  • Supports EtherCAT Distributed Clock (DC) mode and SyncManager mode
  • EtherCAT conformance test tool verified

Product Specifications

Model IECS-1116-DI IECS-1116-DO

Digital Input
Channels| 16| —
Input Type| Wet (sink/source) / Dry (source)| —
Wet Contact| ON Voltage Level| 3.5~50V| —
OFF Voltage Level| 4V max| —
Dry Contact| ON Voltage Level| Close to GND| —
OFF Voltage Level| Open| —
Photo Isolation| 3750V DC| —
Digital Output
Channels| —| 16
Output Type| —| Open collector (sink)
Load Voltage| —| 3.5~50V
Max. Load Current| —| 700mA per channel
Photo Isolation| —| 3750 vrms
Communication Interface
Connector| 2 x RJ45
Protocol| EtherCAT
Distance between Stations| Max. 100m (100BASE-TX)
Data Transfer Medium| Ethernet/EtherCAT cable (min. cat5),

shielded

Power
Input Voltage Range| 9~48V DC
Power Consumption| 4W max.
Mechanical
Dimensions (W x D x H)| 32 x 87 x 135 mm
Installation| DIN-rail mounting
Case Material| IP40 metal
Environment
Operating Temperature| -40~75 degrees C
Storage Temperature| -40~75 degrees C
Relative Humidity| 5~95% (non-condensing)

Hardware Introduction

4.1 Three-View Diagram
The three-view diagram of the Industrial EtherCAT slave I/O module consists of two 10/100BASE-TX RJ45 ports, one removable 3-pin power terminal block and one removable 16-pin I/O terminal block. The LED indicators are also  located on the front panel.

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - Feager3

Front View

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - fornt view

LED Definition:
System

LED Color Function

PWR

| ****

Green

| Light| Power is activated.
Off| Power is not activated.



Running

| ****


Green

| Light| The device is in the state of operation.
Single Flash| The device is in the state of operation without risk.
Blinking| The device is ready to be operated.
Off| The device is in the initialization mode.

Per 10/100TX RJ45 Port (Port Input/Port Output)

LED Color Function

LNK/ ACT

| ****


Green

| Light| Indicating that the port is linked up.


Blinking

| Indicating that the module is actively sending or receiving data over that port.
Off| Indicating that the port is linked down.

Per Digital Input/Output LED

LED Color Function
DI Green Light

voltage.
Blinking| Indicating network packet delivery.


Off

| Input voltage is below the lower switching

threshold voltage.

DO| Green| Light| Digital output status is “On”.
Blinking| Indicating network packet delivery.
Off| Digital output status is “Off”.

I/O Pin Assignment: IECS-1116-DI

Terminal No.| Pin Assignment| | Pin Assignment| Terminal No.
---|---|---|---|---
1| GND| GND| 2
3| DI0| DI1| 4
5| DI2| DI3| 6
7| DI4| DI5| 8
9| DI6| DI7| 10
11| DI8| DI9| 12
13| DI10| DI11| 14
15| DI12| DI13| 16
17| DI14| DI15| 18
19| DI.COM| DI.COM| 20

IECS-1116-DO

Terminal No.| Pin Assignment| | Pin Assignment| Terminal No.
---|---|---|---|---
1| Ext. GND| Ext. GND| 2
3| DO0| DO1| 4
5| DO2| DO3| 6
7| DO4| DO5| 8
9| DO6| DO7| 10
11| DO8| DO9| 12
13| DO10| DO11| 14
15| DO12| DO13| 16
17| DO14| DO15| 18
19| Ext. PWR| Ext. PWR| 20

Top View

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - top view

4.2 Wiring Digital and Digital Connections
Digital Input Wiring

Digital Input/ Counter

| Readback as 1|

Readback as 0

---|---|---
Dry Contact| |
Sink| |
Source| |

Output Type

| ON State Readback as 1|

OFF State Readback as 0

---|---|---

Driver Relay

| |

Resistance Load

| |

4.3 Wiring the Power Inputs
The 3-contact terminal block connector on the top panel of Industrial EtherCAT slave I/O module is used for one DC power input. Please follow the steps below to insert the power wire.

| When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock.
---|---

  1. Insert positive and negative DC power wires into contacts 1 and 2 for POWER.PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch Digital Input Output - power
  2. Tighten the wire-clamp screws for preventing the wires from loosening.

| 1. The DC power input range is 9-48V DC.
2. The device provides input voltage polarity protection.
---|---

4.4 Wiring the Connector

  • A tip for connecting the wire to the I/O connectorPLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch Digital Input Output - connector
  • Insulated Terminals Dimensions

Dimensions (Unit: mm)


Item No.| F| L| C| W
CE007512| 12.0| 18.0| 1.2| 2.8

  • A tip for removing the wire from the I/O connectorPLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch Digital Input Output - connector1

Installation

This section describes the functionalities of the Industrial EtherCAT slave I/O module’s components and guides you to installing it on the DIN rail and wall. Please read this chapter completely before continuing.

| In the installation steps below, this manual uses PLANET IGS-801 8-port Industrial Gigabit Switch as an example. The steps for  PLANET Industrial Slim-type Switch, Industrial Media/Serial Converter and Industrial PoE devices are similar.
---|---

5.1 DIN-rail Mounting Installation
Refer to the following steps to install the Industrial EtherCAT Slave I/O Module on the DIN rail.
Step 1: The DIN-rail bracket is already screwed on the module as shown in the red circle.

Step 2: Lightly insert the bottom of the module into the track.

Step 3: Make sure the bracket is tightly secured on the DIN-rail track.

Step 4: To remove the module from the track, lightly pull out its bottom.

5.2 Wall-mount Plate Mounting
To install the Industrial EtherCAT slave I/O module on the wall, follow the instructions described below.
Step 1: Remove the DIN-rail bracket from the Industrial EtherCAT slave I/O module by loosening the screws.
Step 2: Screw one piece of the wall-mount plate on one end of the rear panel of the Industrial EtherCAT slave I/O module, and the other plate on the other end.

Step 3: And then screw the module on the wall to complete the installation.
Step 4: To remove the module from the wall, reverse the steps.
5.3 Side Wall-mount Plate Mounting

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - plate mounting1

Caution You must use the screws supplied with the wall mounting brackets. Damage caused to the parts by using incorrect screws would invalidate your warranty.

Getting Started

This chapter provides a basic overview of how to configure and operate your IECS-1116 series.
6.1 Connecting the Power and the Host PC
Step 1: Connect both the IN port of the IECS-1116 Module and RJ45 Ethernet port of Host PC.
Ensure that the network settings on the Host PC have been correctly configured and are functioning normally. Ensure that the Windows firewall and any anti- virus firewall is properly configured to allow incoming connections; if not, temporarily disable these functions.

| Attaching an ESC (EtherCAT Slave Controller) directly to an office network will result in network flooding, since the ESC will reflect any frame – especially broadcast frames – back into the network (broadcast storm).
---|---

Step 2: Apply power to the IECS-1116 module.

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - plate mounting2

Connect the V+ pin to positive terminal on a 9-48V DC power supply, and connect the V- pin to the negative terminal.
Step 3: Verify the “PWR”LED indicator on the IECS-1116 module is Green; “IN”LED indicator is Green.PLANET IECS 1116 DI Industrial EtherCAT Slave I O
Module with Isolated 16 ch Digital Input Output - plate
mounting3 6.2 Configuration and Operation
Beckhoff TwinCAT 3.x is the most commonly used EtherCAT Master software to operate the IECS-1116 module.
Click on the link below to download Beckhoff TwinCAT 3.x: https://www.beckhoff.com/english.asp?download/default.htmPLANET IECS 1116
DI Industrial EtherCAT Slave I O Module with Isolated 16 ch Digital Input
Output - plate mounting4

Inserting into the EtherCAT network

Installation of the latest XML device description (ESI). Make sure to use the latest installation description to install the latest XML device. This can be downloaded from PLANET website (https://www.planet.com.tw/en/support/faq?method=keyword&keyword=IECS-1116) and check the online FAQs for the installation of the XML device.

https://www.planet.com.tw/en/support/faq?method=keyword&keyword=IECS-1116

Step 1: Automatic Scanning.

  • The EtherCAT system must be in the safe, de-energized state before the IECS-1116 module is connected to EtherCAT network.
  • Switch on the operating voltage, open the TwinCAT System Managed (Config mode), and scan the devices as shown in the print screen instructions below. Acknowledge all dialogs with “OK”, so that the configuration is in the “FreeRun” mode.

PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch
Digital Input Output - plate mounting5

Step 2: Configuration via TwinCAT
In the left-hand window of the TwinCAT System Manager, click on the brand of the EtherCAT Box you wish to configure (IECS-1116-DI/IECS- 1116-DO in this example). Click Dix or Dox to get and configure state.![PLANET IECS 1116 DI Industrial EtherCAT Slave I O Module with Isolated 16 ch Digital Input Output

Customer Support
Thank you for purchasing PLANET products. You can browse our online FAQ resource on PLANET web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq.php
Support team mail address: [email protected]

Copyright © PLANET Technology Corp. 2022.
Contents are subject to revision without prior notice.