CONSTRUCTION
Housing:| Durable, long lasting steel construction. Steel, galvanized,
cold-rolled, commercial quality
---|---
Lens:| Precision formed optical assembly drop down door with access to
the power supply from underneath the ceiling plane comprised of high
specularity reflective paint
Paint:| High reflectance baked white enamel finish
Weight:| <16lbs
OPTICAL SYSTEM
Lumens: | Up to 7000 Lumens |
---|---|
Wattage: | Up to 59 Watts |
Efficacy: | Up to 128 LPW |
CCT: | 3500K/4000K/5000K |
CRI: | 80+, R9 >0 |
Distribution: | Medium Lambertian |
Color Consistency: | Central limit 4-Step MacAdam Ellipse with LED |
recipeapproach for tight unit to unit color control
ELECTRICAL
Input Voltage: 120-277V, 347V
Input Frequency: 50/60 Hz
Standard Dimming Control: 0-10v Dimming
Power Factor (PF)*:* >0.9
Total Harmonic Distortion <20%* *(THD):
Surge Protection ANSI C82.77 Compliant
CONTROLS
Dimming: 0-10V Dimming
LUMEN AMBIENT TEMPERATURE
TYPE | TEMPERATURE RATE |
---|---|
OPERATING TEMPERATURE | -20°C to +25°C (-4 °F to +77 °F) |
STORAGE TEMPERATURE | -40°C TO +70°C (-40 °F to +158°F) |
LUMEN MAINTENANCE
LXX(10K) @ Hours 50,000 HR: L85
ADDITIONAL FEATURES
-
Typical Mounting: Fits standard T-Bar grid (drop ceilings)
-
Wiring Access: ½” trade-size KOs on a removable access plate provided
-
Surface Mounting: Factory installed Surface Mount option available
-
Optional Emergency Battery: Provides 90-minutes of Emergency lighting.
Note , EL option is not available with 347V option. Initial design lumen output: 1400 lumens -
Optional Chicago Plenum: Openings in recessed fixture sealed per requirements for CCEA
-
Optional Bypass Relay: Overrides dimming when emergency generator is used (see ordering notes for limitations) Please refer to the DLC QPL website for the latest and most complete formation.www.designlights.org/QPL
DESIGN LIFE & WARRANTY
- Damp Location rated
- All luminaries are built to UL 1598 standards and bear appropriate CSA labels
- Reliability Testing: Components and systems evaluation
- Current’s Limited Warranty:
System Warranty: 5 Year (Please refer to document IND599 for more information)
Ordering Information
FAMILY| MIXTURE TYPE| GENERATION| VOLTAGE| NOMINAL
LUMENS| DISTRIBUTIO| CRI/CCT| MOUNTING| OPTIONS
---|---|---|---|---|---|---|---|---
LBR = Lumination Backlit Recesse| 14 = 1’ x 4’| ’ B = 2nd Generation| 0 =
120-277V D = 347V| V D = 347V 25 = 2500 30 = 3000 35 = 3500 40 = 4000 45 =
4500 55 = 5500| MM = Smooth Frosted Acrylic Lens, .080″ Nominal A1 = Pattern
A12 Acrylic Lens, .095″ Nominal A2 = Pattern A12 Acrylic Lens, .125″ Nominal
MA = Smooth Frosted Acrylic Lens, .080″ Nominal, Flush Aluminum Door| 835 =
80CRI, 3500K 840 = 80CRI, 4000K 850 = 80CRI, 5000K| WHTE= White| (blank) =
None CP = Chicago Plenum EL1 = Emergency Light B23 = Dimming Bypass Module W3
= 6′ Whip, 4 Wire W55 = 6′ Whip, 6 Wire, Dimming Leads SG = Single Gasket,
Door to Housing DG = Double Gasket, SG and Lens to Door TG = Triple Gasket, DG
and Housing to Ceiling WL4 = Wet Location, DG or TG Required
EXAMPLE CONFIGURATIONS| LUMINAIRE LUMENS| LUMINARE TOTAL
SYSTEM WATTS| LUMINAIRE LPW 2
---|---|---|---
LBR14B025MM835VQLTWHTE| 2322| 20| 116
LBR14B030MM835VQLTWHTE| 2923| 27| 108
LBR14B035MM835VQLTWHTE| 3430| 31| 111
LBR14B040MM835VQLTWHTE| 3766| 34| 111
LBR14B045MM835VQLTWHTE| 4158| 38| 109
LBR14B055MM835VQLTWHTE| 4761| 45| 106
LBR14B070MM835VQLTWHTE| 6492| 59| 110
LBR14B025MM840VQLTWHTE| 2358| 20| 118
LBR14B030MM840VQLTWHTE| 2968| 27| 110
LBR14B035MM840VQLTWHTE| 3484| 31| 112
LBR14B040MM840VQLTWHTE| 3824| 34| 112
LBR14B045MM840VQLTWHTE| 4222| 38| 111
LBR14B055MM840VQLTWHTE| 4834| 45| 107
LBR14B070MM840VQLTWHTE| 6593| 59| 112
LBR14B025MM850VQLTWHTE| 2568| 20| 128
LBR14B030MM850VQLTWHTE| 3232| 27| 120
LBR14B035MM850VQLTWHTE| 3794| 31| 122
LBR14B040MM850VQLTWHTE| 4164| 34| 122
LBR14B045MM850VQLTWHTE| 4598| 38| 121
LBR14B055MM850VQLTWHTE| 5264| 45| 117
LBR14B070MM850VQLTWHTE| 7179| 59| 122
Ordering Notes:
- EL option not available in 347V or Surface Mount.
- Most Standard base SKU’s are DLC, there are exceptions for 347V and EL for meeting PF and/or THD results. Please check the DLC QPL.
- For emergency circuit control loads including sensors and wireless systems CSA certified to UL 924. Not available in 347V or with EL option
- Available with MA distribution and LT mounting only.
- To be used in conjunction with EL option.
ACCESSORIES | DESCRIPTION CODE | PRODUCT CODE |
---|---|---|
Drywall mount Kit 1’ x 4’ | GESK09 | 69068 |
DIMENSIONS
END VIEW
Top View
Side View
DIMENSIONAL DATA – SURFACE MOUNT (SM)
NOTE: All dimensions are in inches;dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification.
PHOTOMETRIC DATA
ZONAL LUMEN SUMMARY ZONE LUMENS % OF FIXTURE
0-20| 695.78| 17.2
0-30| 1452.96| 35.9
0-40| 2280.66| 56.4
0-60| 3489.44| 86.3
0-80| 3961.99| 98
0-90| 4043.42| 100
10-90| 3862.54| 95.5
20-40| 1584.88| 39.2
20-50| 2295.65| 56.8
40-70| 1502.12| 37.1
60-80| 472.56| 11.7
70-80| 179.21| 4.4
80-90| 81.43| 2
90-110| 0| 0
90-120| 0| 0
90-130| 0| 0
90-150| 0| 0
90-180| 0| 0
110-180| 0| 0
0-180| 4043.42| 100
ZONAL LUMEN SUMMARY ZONE LUMENS
0-10| 180.88
10-20| 514.9
20-30| 757.18
30-40| 827.7
40-50| 710.78
50-60| 498
60-70| 293.35
70-80| 179.21
80-90| 81.43
90-100| 0
100-110| 0
110-120| 0
120-130| 0
130-140| 0
140-150| 0
150-160| 0