CARRO USA LYDC525J-L12-BG-1-FM 52 Inch Black Color Changing LED Indoor Flush Mount Ceiling Fan Instruction Manual
- June 12, 2024
- CARRO USA
Table of Contents
- CARRO USA LYDC525J-L12-BG-1-FM 52 Inch Black Color Changing LED Indoor
- Basic Product Specifications
- SAFETY PRECAUTIONS
- Fan Diagram
- Tools & Materials Required
- Installation
- Disassemble the Light Set
- Installation: Light Kit Pan & Light Kit
- Installation: Lampshade & Power On
- Remote Control Button Definitions
- Remote Control Instructions
- Troubleshooting
- Care & Cleaning
- FCC Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CARRO USA LYDC525J-L12-BG-1-FM 52 Inch Black Color Changing LED Indoor
Flush Mount Ceiling Fan
Important : Please read and save these instructions before installation
Basic Product Specifications
Model | YDC525JL-FM | Voltage | 120V |
---|---|---|---|
Fan Blade Span | 52″ | Rated Wattage | 42W(Fan 26W Lamp 16W) |
Gross Weight | 15.7Ibs. | Motor RPM | 50-215pm |
Maximum Airflow | 4750CFM | Maximum Noise | 58dB(A) |
Model
| ****
YDC605JL-FM
| ****
Voltage
| ****
120V
Fan Blade Span| 60″| Rated Wattage| 42W(Fan 26W Lamp 16W)
Gross Weight| 17Ibs.| Motor RPM| 75-180rpm
Maximum Airflow| 5400CFM| Maximum Noise| 58dB(A)
Questions
U.S. Patent Nos.: 10,511,206 and 11,296,561. Other Patent(s) Pending Have
questions about our products? Contact us and talk to our helpful tech support
team.
Technical Support
Business Hours: Monday – Friday (Holidays observed). 9:00 am to 5:30 pm PST.
Tel: 888-253-2374
This Carro Ceiling Fan is
SAFETY PRECAUTIONS
-
Before you begin installing the fan, shut the power off at the circuit breaker of the fuse box.
-
Make sure that all electrical connections are in accordance with National Electrical Code, ANSI/NFPA 70, and local codes. Hire a licensed electrician if you are unfamiliar with installing electrical wiring.
-
Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 2.1 m (7 feet) from the floor and 18 inches from the tip of the blades to the wall.
-
The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 35 pounds. Use only U.L. listed outlet boxes marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or less”.
-
Before and after you install the fan, make sure that all mounting components are secured to prevent the fan from falling.
-
Do not insert anything into the fan blades while the fan is operating.
-
To change the direction of the rotation of the blades, the fan must be in operation mode.
-
All set screws must be checked and retightened where necessary before installation.
-
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
-
The splices after being made should be turned upward and pushed carefully up into the outlet box. Conductor wiring identified as grounded is to be connected to a grounded conductor of power supply. Conductor wiring identified as an ungrounded conductor is to be connected to an ungrounded conductor. Conductor wiring identified for equipment grounding is to be connected to an equipment-grounding conductor.
-
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
-
CAUTION: Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.
-
WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked ‘J\cceptable for Fan Support of 15.9 kg (35 lbs) or less” and use mounting screws provided with the outlet box.
-
CAUTION : To reduce the risk of injury, use only the screws provided with the outlet box
in conjunction with the lock washers. -
WARNING: To reduce the risk of personal injury, do not bend the blade bracket when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
-
CAUTION : To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing the light kit.
-
WARNING : To reduce the risk of fire or electric shock, this fan must be installed with general use, non-dimmable, single gang, isolating wall control/switch.
-
WARNING : To reduce the risk of fire or electric shock, do not use this fan with any solidstate speed control device.
NOTE : The important safeguards and instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution, and care are factors that cannot be built into this product. These factors must be supplied by the person (s) installing, caring for, and operating the unit.
- CAUTION: The light source is designed for this specific application and can overheat if serviced by untrained personnel. If any servicing is required, the product should be returned to an authorized service facility for examination or repair.
- WARNING: Do not use corrosive detergents for cleaning.
Fan Diagram
Tools & Materials Required
Package Contents
Before installing, please check to make sure you have received all the
necessary components for installation.
Installation
WARNING: To avoid serious injury or death, turn off the power at the circuit breaker before installing the fan.
Disassemble the Motor
Take the motor assembly out of the box, use a screwdriver to loosen the canopy
screws, and remove the mounting plate. Save the screws for later use.
Installation: Mounting Options
Install the Mounting Plate
You have two options for mounting plate installation. Pick which one works
best for your location.
WARNING: Turn off the power from the breaker circuit first!
Note: For better fan performance, make sure the mounting plate is level.
Option 1 : Fasten the mounting plate with the ST5x24 wood setscrews
(included) when securing to the wooden ceiling beam or support structure with
an approved electrical outlet box as shown in Fig 2.1.
Option 2: Use machine screws (provided with outlet box) and washers when
securing to an existing ceiling fan-rated outlet box. If the mounting plate is
installed at the outlet box, it should be installed on the outlet box with the
screws that came with your outlet box itself. Pull the supply wires (the
black, white, and ground wires) out of the outlet box and through the hole in
the mounting plate, and lay them to the side.
WARNING : DO NOT use the plastic outlet box. Use only U.L. listed outlet
boxes marked ”Acceptable for Fan Support of 15.9 kg (35 lbs) or less”.
Installation: Wiring
Hang the Fan
Carefully lift the fan motor assembly. Hang the motor assembly on the hook of
the mounting plate by utilizing one of the holes at the outer rim of the motor
housing so that it is securely suspended.
Connect the Wiring
- The Green/Yellow wire from the mounting plate connects with the supply Ground wire using the wire nut.
- Connect the White wire from the motor to the supply White (Neutral) wire using a wire nut.
- Connect the Black wire from the motor to the supply Black/Red (Hot/Live) wire using a wire nut.
- Then hide them inside the motor housing. (Make sure all the wires are connected to the correct colors as shown in Fig 4.1)
- Attach the other end of the safety rope to a safe place.
Note: Installing the ceiling fan with a safety rope is an extra safety feature. It secures the fan to the ceiling hook or safe place and avoids the fan from falling even in the case of material failure.
Installation: Securing the Fan
Secure the Fan
- Reinstall two of the four canopy screws (located across from each other) that were removed in step 1 to the mounting plate, but DO NOT tighten them yet.
- Using both hands, lift the fan body from the hook. Align the two key slots in the top of the motor assembly with the two loosened screws on the mounting plate.
- Push the fan motor assembly up and turn it counterclockwise to lock in the mounting plate. Tighten the two screws. Reinstall the other two canopy screws into the remaining two holes and tighten the four screws firmly.
WARNING : Falling fan hazard, make sure all screws are tightened to secure the fan motor assembly.
Installation: Blade Brackets
Install the Blade Brackets
- Locate 10-blade bracket attachment screws in the hardware pack. Install the blade bracket screws to secure each blade bracket to the motor hub securely.
- Repeat these steps for the remaining blade brackets. Make sure all the screws are firmly tightened.
Installation: Fan Blades
Locate 15-blade attachment screws with integrated washers in the hardware
pack. Make sure the screw holes on each fan blade match the corresponding
holes on the blade bracket and tighten the blade screws as shown in Fig 7.1.
Five blades are installed as shown in Fig 7.2.
Disassemble the Light Set
Remove the light assembly out of the box and turn the lampshade counterclockwise to disassemble it as shown in Fig 8.1, and then remove the LED light kit out of the light kit pan directly as the light kit is fixed by magnetic attraction. The light assembly after disassembly is shown in Fig 8.2.
Installation: Light Kit Pan & Light Kit
- Remove one screw from the light kit plate of the motor assembly and loosen but Do Not remove the other two screws.
- Push the light kit pan to the light kit plate so that the two loosened screw heads fit into the keyhole slots. Feed the light wire connector plug and safety rope through the center hole of the light kit pan.
- Turn the light kit pan clockwise. Reinstall the screw that was removed. Make sure all the screws are firmly tightened.
- Allow the light wire connector plug and safety rope to come through the light kit.
- Reinstall the light kit. The light kit is magnetically attracted to the pan with the help of magnets. Insert the light wire connector plug into the light kit terminal block.
Installation: Lampshade & Power On
Rotate the lampshade clockwise and securely lock into the light kit pan as
shown in Fig 10.1.
WARNING : To prevent SERIOUS INJURY or DEATH, make sure that the
lampshade is properly secured. Allow the lampshade to cool completely before
removing it. Power On At this time, the ceiling fan has been installed. Turn
on the power supply from the breaker circuit of the main switch or the room
where the ceiling fan is installed. After the power is on, observe whether the
fan light is on.
Remote Control Button Definitions
Remote Control Instructions
- Pair the Remote Control to Your Fan
- Power on the fan and pair the remote to the fan within 1 min. To pair the remote to the fan, press and hold the button for 3-5 secs to pair the remote to the fan.
- The successful pairing will trigger the fan light off.
- Remote Control Button Definitions
- Turns the fan off.Switches between summer mode and winter mode. ·Summer mode – (Counter-clockwise)
- A downward airflow creates a cooling effect.
- Nature Switches the fan speed between nature mode and normal mode. Simulates a natural breeze, gentle enough not to disturb you while you sleep.
- Turns the lights on or off and RF pairing.
- Note : Power on the fan and pair the remote to the fan within 1 min. To pair the remote to the fan, press and hold the button for 3-5 secs to pair the remote to the fan. The successful pairing will trigger the fan light off.
- Switches between warm light and cool light.
- Press/Hold the button to decrease the light intensity.
- Press/Hold to button to increase the light intensity.
Troubleshooting
Try these troubleshooting steps before contacting Customer Service. For additional operation, maintenance, and troubleshooting information, please contact our customer service center.
Care & Cleaning
- Check the support connections, brackets, and blade attachments twice a year. Make sure they are secure. Because of the fan’s natural movement, some connections may become loose over time. It is not necessary to remove the fan from the ceiling.
- Clean your fan periodically. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
- (Optional) Apply a light coat of furniture polish to the wood blades.
- (Optional) Cover small scratches with a light application of shoe polish.
DO NOT
- Use water when cleaning. Water could damage the motor, or the wood, or possibly cause an electrical shock.
- Apply oil to your fan or motor. The motor has permanently lubricated sealed ball bearings.
WARNING : Power off the fan before performing maintenance or cleaning the fan.
FCC Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>