SALON SAFE E650-Fi Energy Recovery Ventilation Kit User Guide

June 12, 2024
SALON SAFE

SALON SAFE E650-Fi Energy Recovery Ventilation Kit

Product Information

The EsnoeurgrcyeRceacpotuvreeryveVnetniltailtaiotonrsSyysstetemm is a commercial ventilation system that provides premier indoor air quality for businesses. It is considered the best-in-class and is known for its effectiveness and energy efficiency. Manufactured by American Aldes, a company with over 30 years of experience in providing innovative ventilation solutions, the Esnoeurrgcye cRaepctouvrervyeVnetinlattiliaotnor sSyysstteemm is suitable for hotels, multi-family dwellings, schools, retail stores, homes, and the beauty industry.

The system includes the following components:

  • Recirculation Port
  • CAR-II-HP Energy Recovery Ventilator
  • Booster Fan (120 VAC)
  • Flex duct (supplied by others)
  • Airflow Supply Air Tubing
  • Positive/Negative Pressure Switch (24 VAC)
  • Multi-function Controller (120 VAC)

Product Usage Instructions

Locating the EsnoeurgrcyeRceacpotuvreeryveVnetniltailtaiotonrsSyysstetemmThe device should be placed in a location where the temperature is always above freezing. Choose a location that minimizes the use of elbows in the ducts to ensure optimal functioning of the system.

Guidelines for Locating Intake and Exhaust Wall Hoods

  • For outside corners, a minimum distance of 36 inches (1 meter) is recommended.
  • For inside corners, a minimum distance of 36 inches (1 meter) is recommended.
  • The intake should be located at least 10 feet away from the device (6 feet or 2 meters recommended minimum).
  • The exhaust should be located at least 18 inches (460 mm) away from the device (recommended minimum).
  • Pressure Switch Installation

The pressure switch is a 120V control that activates the Booster Fan when the
EsnoeurgrcyeRceacpotuvreeryveVnetniltailtaiotonrsSyysstetemm is in use. Follow these steps to install the pressure switch:

  1. Mount the pressure switch vertically, avoiding air tubing connections facing upwards.
  2. Connect the high-pressure port of the pressure switch to the Supply Air duct of the EsnoeurgrcyeRceacpotuvreeryveVnetniltailtaiotonrsSyysstetemm using tubing and grommet.
  3. Connect wiring to the pressure switch and Booster Fan as follows:
    • Use a 4×4 junction box (J-Box) for adequate space for all wiring connections.
    • Connect the incoming electrical supply, switch leads, and power supply to the fan as shown in the diagram.

Booster Fan Installation

The Booster Fan is designed to overcome excess external static pressure in the exhaust airstream of the EsnoeurgrcyeRceacpotuvreeryveVnetniltailtaiotonrsSyysstetemm. Follow these steps to install the Booster Fan:

  1. Mount the Booster Fan using the included mounting bracket. It can be mounted horizontally or vertically.
  2. Note the airflow direction of the Booster Fan and ensure it is installed accordingly.
  3. The Booster Fan will receive 120VAC power supply from the Pressure Switch.

Welcome
Congratulations on your purchase of a Salon Safe® Ventilation System

You are now the proud owner of an soEnergy urce capRecovery ture veVntilaentilator tion systeSystemm , the best-in-class for commercial ventilation. It will provide you with many years of premier indoor air quality for your business. Your souEnergy rce captuRecovery re veVntilatientilatoron sysSystemtem is the most effective and energy-efficient ventilation system available on the market today.

This quick-start guide provides basic information about your ventilation system including how to operate and install the system. Refer to the separate installation and operation manuals for more detailed information.
For more information visit: www.SalonSafe.net

What’s Included

Please inspect the contents of your system.

System Includes

  • Multifunction Controller
  • Pressure Switch
  • Booster Fan
  • Constant Airflow Regulators

The Salon Safe Energy Recovery Ventilation kits
Are composed of multiple products working together to achieve the goal of exhausting harmful vapors that are produced within nail salons. While exhausting these harmful vapors, the Salon Safe Energy Recovery Ventilation kit also provides fresh outside air and eliminates crosscontamination of airflows. The Salon Safe Energy Recovery Ventilation kits are designed to produce very little sound while operating and remain both energy efficient and cost effective. The kit includes: a main ERV unit, a 24 VAC Multifunction Control, a 120 VAC In-Line Booster

Kit Component Diagram

What It Does

  • The ERV is a combined supply and exhaust ventilator. One airstream removes air from the building and exhausts it to the outdoors. The other airstream brings in air from the outdoors and supplies it to the building
  • Locating the Air Exchanger The device must be located in a place where the temperature is always above freezing. Choose a location for the device where the ducts will be situated with minimal use of elbows. This ensures that the system functions optimally.

Pressure Switch

  • The pressure switch is a 120V control that is designed to turn the Booster Fan on once the ERV has been activated.
  • Mount the pressure switch with the diagram in any vertical plane. Avoid mounting with the air tubing connections up. (See the illustration shown at right.)
  • Connect the high pressure port of pressure switch to the Supply Air duct of the ERV utilizing the tubing and grommet.

Connect wiring to pressure switch and Booster Fan as follows:

  1. A 4”x4” junction box (J-Box) is recommended for adequate space for all wiring connections.
  2. Connect the incoming electrical supply, the switch leads, and the power supply to fan as shown on the right.

Booster Fan

  • The Booster Fan is designed to overcome excess external static pressure in the exhaust airstream of the Energy Recovery Ventilator (ERV). 120VAC is supplied to the Booster Fan by the Pressure Switch.
  • Use the included mounting bracket to mount the
  • Booster Fan. The Booster Fan can be mounted horizontally or vertically. Note the airflow direction of the Booster Fan.
  • Connect 120VAC wiring from the Pressure Switch as shown to the right.