BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt Installation Guide

June 4, 2024
BRUNDLE

TILT-LOC Glass Spigot Side Fix Tilt
Installation Guide

PRODUCT CODE

1822013
STEP 1
Drill holes and install screw, exposed thread length 23mm, slide on the spigot.

BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt -
fig

STEP 2
Tighten the nut using the adaptor included. Requires a 16mm spanner.

BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt - fig
1

STEP 3
Install gaskets and screws.

BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt - fig
2

STEP 4
Install the glass, and adjust the glass angle to align to the adjacent panel. (the adjustment range is ±2°)

BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt - fig
3

STEP 5
Tighten the screws using a 5mm Allen key.

BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt - fig
4

STEP 6
Please pay attention when tightening the third screw, as this has the effect on increasing the clamping strength.
ASKET SPECIFICATIONS ARE REQUIRED TO INSTALL DIFFERENT GLASS

Glass Gasket
10 – 12mm 1 U gasket + 5 x 1mm flat gaskets
12 – 13.52mm 1 U gasket + 4 x 1mm flat gaskets
13.52 – 15mm 1 U gasket + 2 x 1mm flat gaskets
15 – 16.76mm 1 U gasket + 1 x 1mm flat gasket
16.76 – 17.52mm 1 U gasket

Whilst every effort has been made to ensure the accuracy of the information supplied. F.H. Brundle cannot be held responsible for any errors or omissions. This product must nly be employed for its original intended use. Any other use is wrong and potentially dangerous. Installation must be carried out in full compliance with current regulations. F.H.  rundle cannot be held liable for any damages resulting from wrongful, erroneous or negligent use.

Tel: 01708 25 35 45
sales@brundle.com
www.fhbrundle.co.uk