BRUNDLE 1822013 TILT-LOC Glass Spigot Side Fix Tilt Installation Guide
- June 4, 2024
- BRUNDLE
Table of Contents
TILT-LOC Glass Spigot Side Fix Tilt
Installation Guide
PRODUCT CODE
1822013
STEP 1
Drill holes and install screw, exposed thread length 23mm, slide on the
spigot.
STEP 2
Tighten the nut using the adaptor included. Requires a 16mm spanner.
STEP 3
Install gaskets and screws.
STEP 4
Install the glass, and adjust the glass angle to align to the adjacent panel.
(the adjustment range is ±2°)
STEP 5
Tighten the screws using a 5mm Allen key.
STEP 6
Please pay attention when tightening the third screw, as this has the effect
on increasing the clamping strength.
ASKET SPECIFICATIONS ARE REQUIRED TO INSTALL DIFFERENT GLASS
Glass | Gasket |
---|---|
10 – 12mm | 1 U gasket + 5 x 1mm flat gaskets |
12 – 13.52mm | 1 U gasket + 4 x 1mm flat gaskets |
13.52 – 15mm | 1 U gasket + 2 x 1mm flat gaskets |
15 – 16.76mm | 1 U gasket + 1 x 1mm flat gasket |
16.76 – 17.52mm | 1 U gasket |
Whilst every effort has been made to ensure the accuracy of the information supplied. F.H. Brundle cannot be held responsible for any errors or omissions. This product must nly be employed for its original intended use. Any other use is wrong and potentially dangerous. Installation must be carried out in full compliance with current regulations. F.H. rundle cannot be held liable for any damages resulting from wrongful, erroneous or negligent use.
Tel: 01708 25 35 45
sales@brundle.com
www.fhbrundle.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>