Honeywell Home T87 Range Stops
Product Information: T87 Range Stops
The T87 Range Stops are designed to be used with the T87K, N thermostats in
order to limit the minimum and maximum temperature settings. The package
includes two range stop scales and two #2-28 x 3/8 Phillips pan head screws.
The range stops are available in both Fahrenheit and Celsius scales:
- Fahrenheit Scale: Low Limit Range Stop – 42°F to 80°F
- Fahrenheit Scale: High Limit Range Stop – 60°F to 88°F
- Celsius Scale: Low Limit Range Stop – 6.5°C to 26°C
- Celsius Scale: High Limit Range Stop – 14.5°C to 31°C
For detailed installation instructions and usage guidelines, please refer to the user manual.
Product Usage Instructions: T87 Range Stops
- Set the thermostat to a temperature setting that falls in the middle of the desired upper and lower temperature range.
- If the thermostat is already attached to its base, remove it.
- On the back of the thermostat, align the range stop with the holes on the back of the thermostat.
- Using the temperature markings on the range stop, insert the supplied screws into the minimum and/or maximum range stop holes and tighten them.
- Mount the thermostat onto its base and set the desired temperature.
Note: Make sure to refer to the appropriate table for the range stop temperatures based on the desired Fahrenheit or Celsius scale.
APPLICATION
Use the 50010944-001 range stops with the T87K, N thermostats to limit the
minimum and maximum temperature settings.
The 50010944-001 contains two range stop scales and two #2-28 x 3/8 phillips
pan head screws.
INSTALLATION
- Set the thermostat to a temperature setting in the middle of the upper and lower range desired.
- Remove the thermostat from its base (if already attached).
- On the back of the thermostat, align the range stop with the holes on the back of the thermo-stat. See Fig. 3.
- Using the temperature markings on the range stop, insert supplied screws into the minimum and/or maximum range stop holes and tighten. Refer to Tables 1 and 2 for range stop tempera-tures. See Figs. 4 and 5.
- Mount the thermostat onto its base and set desired temperature. See Fig. 5.
Table 1. Low Limit Range Stop
°F | °C |
---|---|
42 | 4 |
44 | 5 |
46 | 6.5 |
48 | 8 |
50 | 9 |
52 | 10 |
54 | 11 |
56 | 12 |
58 | 13 |
60 | 14.5 |
62 | 15.5 |
64 | 16.5 |
66 | 17.5 |
68 | 19 |
70 | 20 |
72 | 21 |
74 | 22.5 |
76 | 23.5 |
78 | 24.5 |
80 | 26 |
Table 2. High Limit Range Stop
°F | °C |
---|---|
88 | 31 |
86 | 29.5 |
84 | 28 |
82 | 27.5 |
80 | 26 |
78 | 25 |
76 | 24 |
74 | 22.5 |
72 | 21.5 |
70 | 20 |
68 | 19 |
66 | 18 |
64 | 17 |
62 | 16 |
60 | 14.5 |
Resideo Technologies, Inc.