Bradford EcoFan Ventilation Subfloor Vent Instruction Manual
- June 12, 2024
- Bradford
Table of Contents
- EcoFan Ventilation Subfloor Vent
- Product Manual
- Item Checklist
- Additional Parts & Tools Required (Not Supplied)
- Important Notices and Warnings
- Install at your own risk
- Important Notes
- Installation
- STEP 3: Clear the hole of debris.
- Installation—Electrical Connection
- Installation—Speed Control Mode
- Convert From Exhaust to Supply Flow Direction
- Removing Wall grille for Painting
- Technical Data
- Performance Data & Product Dimensions
- FAQ & Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EcoFan Ventilation Subfloor Vent
Product Manual
Item Checklist
Included Parts: QTY:
- EcoFan™ (1)
- Speed Controller (1)\
- Power Supply (1)
- 10m Low Voltage Extension Lead (1)
- Speed Controller Fixing Screws 6Gx13mm(2)
- 6mm Wall Plugs (4)
- 8Gx32mm CSK Screws (4)
- Product Manual (1)
- Warranty Document (1)
Additional Parts & Tools Required (Not Supplied)
Hammer
Impact Drill & 6mm Masonry Drill Bit
Screwdriver with Phillips (P2) Bit
Marker Pen
Cable Ties
Important Notices and Warnings
WARNING: Do not proceed with the installation until you have read the entire instructions, including these warnings.
Install at your own risk
The installation of this product may be dangerous and includes the potential of personal injury or property damage. Please take care when installing this product and be mindful of risks. Please be aware of the following when installing this product.
- Installation requires the cutting and removal of bricks. This process can produce airborne debris and other hazards. To minimise risks wear appropriate personal protection equipment such as appropriate eye protection, gloves and a dust mask.
- When selecting a location for the EcoFan make sure that the area is clear of services such as pipes and power cables.
- Only install into non structural sections of walls. Ensure wall is not load bearing.
Important Notes
- The EcoFan is designed for general household ventilation only. DO NOT use to exhaust hazardous or explosive materials and vapours.
- One side of the EcoFan has an unguarded fan assembly. DO NOT use in locations that expose the unguarded side to areas readily accessible to people or animals.
- Always use the provided power supply and speed controller to power the fan. Failure to do so can damage the product.
- Ensure that the power supply and speed controller are not left on damp surfaces, fasten to available structure with cable ties if required.
- Only use one EcoFan per speed controller and power supply.
Installation
STEP 1 Select appropriate position. Using the fan housing as a guide, mark out a circle/location on the wall.
STEP 2—Option A Using an impact drill and 6mm drill bit. Drill holes spaced 3-4 cm around the marked perimeter.
Using a hammer carefully knock out the bricks to form a circular hole in the wall.
STEP 2: Option B Remove the complete top and bottom shaded bricks. Cut and remove the middle shaded bricks.
STEP 3: Clear the hole of debris.
STEP 4 Insert the EcoFan into the hole.
Make sure it is level and the correct way up.
Mark the positions of the mounting holes.
The back of the wall grille has a mark to indicate correct orientation.
STEP 5
Remove the unit and using a 6mm masonry bit, drill mounting holes as marked previously.
STEP 6
Insert supplied wall plugs into the 6mm drilled mounting holes.
Tap into hole with hammer until flush.
STEP 7
Using the supplied screws, screw the EcoFan into the wall plugs.
Installation—Electrical Connection
STEP 1
Connect the lead coming from the
EcoFan unit to the speed controller
STEP 2
Connect the extension lead to the speed controller.
STEP 3
Connect the power supply lead to the extension lead.
STEP 4
Connect the power supply to a mains socket. Turn on and check fan runs freely.
STEP 5
Using either the screws supplied or cable ties mount the speed controller and the power supply in a suitable location that prevents them from getting wet.
STEP 6
How the connectors clip together
Set the control mode by pressing the button on the side of the speed controller.
Ensure the power supply and speed controller are not in contact with damp or wet surfaces.
Installation—Speed Control Mode
The speed controller has 4 operating modes. These can be cycled through by pressing the button on the speed controller
The order of modes are: LO, MED, HI, AUTO. When engaging AUTO mode the fan will speed up to full speed and then slow down to a stop to provide feedback that AUTO has been selected. Once this
startup procedure is complete the fan will analyze the environment and run at the appropriate speed.
MODES:
LO – Continuous operation, low speed, low flow rate, very quiet, very low power consumption.
MED – Continuous operation, moderate speed, moderate flow rate.
HI – Continuous operation, high speed, high flow rate.
AUTO (default) – Variable speed. The EcoFan will automatically increase or decrease the speed of the fan depending on the subfloor temperature (30°C-45°C) and subfloor relative humidity
In AUTO mode the EcoFan will run based off the environmental conditions. When the conditions are deemed suitable for no ventilation the unit will enter a power savings mode and the motor will not run.
Convert From Exhaust to Supply Flow Direction
STEP 1
Remove the 4 screws fixing the fan housing to the wall grille.
There are arrows on the motor housing that indicate the direction of airflow
STEP 2
Reverse the fan housing and using the same screws mount the housing to the wall grille.
The motor cable should always be pointing downwards.
Removing Wall grille for Painting
STEP 1
Remove the 4 screws fixing the fan housing to the wall grille.
The plastic used for the wall grille is suitable for painting with standard spray paints without priming. The surface must be clean before painting.
STEP 2
Paint wall grille and allow to dry.
Reattach the wall grille to the fan housing using the screws removed earlier (Step 1 in reverse).
Technical Data
Material:
Wall Grille: Plastic (ASA)
Fan & Motor Housing: Plastic (PP-TD20)
Fan Impeller: Plastic (PA6-GF30)
Screws: Stainless Steel (304)
Weight: 1.5 kg
Electrical:
Power Supply
Type: Electronic Switching Mode
Input: 100-240VAC, 1~, 50/60Hz, 2A
Output: 24 VDC
Fan Motor: Electronic Commutating (EC) motor
Internal Voltage: 24 VDC
Protection Class: IP54
Speed Control
Type: Temperature & Humidity Sensing Electronic Variable Speed Controller
Input Voltage: 24 VDC
Fixed Speed Operation: Three fixed speeds (LO, MED & HI), manually selectable via button
Automatic Variable Speed Operation:
Variable speed response relative to environmental conditions of speed controller location.
– See tech data sheet for additional information.
Performance Data & Product Dimensions
Speed
|
Sound Pressure Level (SPL) LA
@ psF=0
[dB(A)]
|
Max. running power consumption [W]
|
Flow rate qv @ psF=0 [m3/hr]
---|---|---|---
LO
|
32.8
|
6.9
|
280
MED
|
43
|
16.1
|
457
HI
|
53.5
|
37
|
734
NOTE—Sound pressure level measured 1m from fan inlet
13
FAQ & Troubleshooting
Q: Do I need an electrician to install the EcoFan?
A: If you have an available power point that can be reached then no electrician is required. If a power point is unavailable then an electrician will be required to install one.
Q: Can I wire it directly into the mains power?
A: No, you must use the supplied power supply and speed controller for the EcoFan to work correctly. Failure to do so may damage the product.
Q: Can I duct the EcoFan?
A: Yes the EcoFan can be ducted in either exhaust or inlet mode by slipping 250mm diameter ducting over the lip of the motor housing and fixing with tape.
Q: Can I paint the EcoFan?
A: Yes, standard spray paint can be used to paint the EcoFan. No plastic primer is required, however the surface must be clean before paint application. Do not get any paint on the motor/fan module. The product should be disassembled to facilitate easier painting. Instructions on disassembly can be seen on page 11 of this manual.
Troubleshooting
Problem Possible Actions
Motor / Fan Not Running
|
Controller may be in AUTO mode and may have determined that no ventilation is necessary. Change to LO to confirm controller is functioning
Check all connections are secure
Check Power supply is plugged in
Check Power Socket is turned on
Contact Details
General Enquiries and Support
PH: 1300 760 233
Email: sales@csr.com.au
Technical Ventilation Enquiries
PH: 1800 354 044
Please fill out for your reference in case support is required
Serial Number
|
Purchase Date
|
/ /
November 2022
I-041-C
Bradford is a business division of CSR Building Products Limited ABN 55 008 631 356
10 Stanton Road, Seven Hills NSW 2147 Australia | www.bradfordventilation.com.au
References
- Home and Commercial Ventilation | Bradford Ventilation
- Home and Commercial Ventilation | Bradford Ventilation
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>