DAH solar 455W Full Black PV Module User Manual

October 30, 2023
DAH solar

USER MANUAL
Reinvents the PV Module

ELECTRICAL INSTALLATION

DAH solar 455W Full Black PV Module - ELECTRICAL INSTALLATION
1

  • Electrical performance parameter of module, such as nominal value of Isc 、Voc and Pmas has ±3% random error compared with value of STC. The standard testing environment of module is:  Irradiance 1000/m2 、Cell temperature 25 ℃、Spectrum AM 1.5.
  • Normally, the current and voltage of module, will be a little higher compared with the value under STC, so when confirmed the associated parameters of solar system accessories, such as rated  voltage 、cable capacity 、fuse capacity and module power, the corresponding short circuit current and open circuit voltage should be amplified by 1.25 times.
  • The maximum number of modules per series string must be calculated according to the requirements. The value of the Voc in the local expected minimum temperature cannot exceed the maximum  system voltage value specified of the module (According to IEC61730 safety test, the maximum system voltage of DAH Solar Module is DC1000V) and other DC electrical components require values.
  • The Voc correction factor can be calculated according to the following formula: CVoc=1-βVoc×(25-T), T is the minimum ambient temperature expected for the installation of the system, β (% / ℃) is The temperature coefficient of the selected module Voc (according to the corresponding module data sheet).
  • If the reverse current which probably exceed the maximum fuses current of module passed through the module, the modules must be protected by an equivalent current protection device. If the number of parallel is more than or equal to 2 strings, there must be equipped an overcurrent protection device on each series of modules.

WARNING

DAH solar 455W Full Black PV Module - ELECTRICAL INSTALLATION
2

  • When Module exposed to sunshine or other lights, it can produce DC, in this case it may cause electric shock hazard if touch electrical parts.
  • Focus sunlight on to PV module via mirror or lenses is prohibited.
  • Temples glass and back sheet have protective effect, broken PV modules have electrical risks(electric shock and burnt), this kind of modules can not be fixed or repaired, should be replaced in time.
  • Under nominal outdoor condition, the current and voltage produced by module are different with datasheet. The parameters in datasheet is tested under STC condition, therefore when determining other components rated voltage, wire capacity, fuse rate, controller capacity and PV module power output relative datas of PV system, please refer to the short circuit current and open circuit voltage of the PV module, and design and install the system in 125% of the value as well.
    • In case to lower electric shock or burnt risk, it’s better to cover the PV modules by opaque material when installing.
    • PV array installation job should be operated under isolating sunlight condition, installation and maintenance also should be handled by professionals.
    • If batteries bank equipped in the PV system, it should comply with battery supplier’s suggestion.
    • PV modules shall not replace rooftop and wall material, partial replacement is also not allowed.
    • Don’t install PV modules in the area where may has combustible gases.
    • Touch PV module’s electrical part by hand directly is prohibited, should use insulating tools to handle the electrical connecting.
    • Don’t dismantle any components of DAH Solar PV module personally.
    • Don’t lift modules by junction box or connecting cables.
    • All the modules system should be connected to ground, if without special stipulations, please refer to International Electrical Standard or other International Standards.
    • Please do not stand, sit, lying on modules, it may damage modules and also have injured risks.
    • Same size and specification models modules can only be connected together.
    • During delivery please make sure transport tools or modules are not subjected to large vibrations, vibrations may cause modules damage or cells microcrack inside of modules.
    • During all the delivery, don not allow modules to fall onto ground from transport tools, house or hand, this will damage modules or cells inside.
    • Don’t wipe the module with corrosive chemicals.
    • When loads are working, please do not disconnect the modules.


Please read the manual carefully

“Please remember that you are using a electricity generation product, in order to avoid any accident, it should adopt relative security measures.”

THANKS FOR CHOOSING DAH SOLAR

Installation Safety
  • Please wear protective headcoats, insulated gloves, and rubber insulated shoes during installation job.
  • To avoid unnecessary touching of the PV module during installation. The surface of modules may over heated, it has risk of burnt and electric shock.
  • Due to the risk of electric shock, please do not proceed the installation work if junction box was wet.
  • Use insulated and dry tools, do not use wet tools.
  • Don’t use sharp tools to wipe the glass of PV module. It would leave scratches on the module.
Climatic Condition

DAH solar 455W Full Black PV Module - Climatic
Condition

Angle Selection

The PV modules should be installed in the place with the maximum sunlight thoughout the year. The output power will be maximum when modules are facing the sun in vertical. In the northern hemisphere, modules should be placedtoward south as the first choice, while in the southern hemisphere, it should be placed toward north.

DAH solar 455W Full Black PV Module - Angle Selection

INSTRUCTION OF INSTALLATION METHODS

SCREWS INSTALLING METHOD
Modules can be attached through the mounting holes on the back frame of the module, by fixing the module to the support rails with bolts. The mounting details are shown in the following figures.

DAH solar 455W Full Black PV Module INSTRUCTION OF INSTALLATION METHODS
1

Secure the module in each mounting location with an M8 bolt and a flat washer, spring washer and nut as shown in
Figure 1 and tighten to a torque of 16~20 N.m(140-180lbf.in.).
All parts in contact with the frame should use flat stainless steel washers of minimum 1.8mm thickness with an outer diameter of 20-24mm (0.79-0.94in).

CLAMPS MOUNTING METHOD
The clamp must overlap the module frame by at least 7mm (0.28in) but no more than 10mm (0.39in).

DAH solar 455W Full Black PV Module - INSTRUCTION OF INSTALLATION METHODS
2

When choosing this type of clamp-mounting method, use at least four clamps on each module, two clamps should be attached on each long sides of the module (for portrait orientation) or each short sides of the module (for landscape orientation). Depending on local wind and snow loads, additional clamps may be required to ensure that modules can bear the load.

All mentioned clamp mounting methods here are only for reference, DAH Solar will not be responsible for the system design and installation. The mechanical loads and its safety must be operated and completed by the professional solar system installer and experienced installation team.

DISCLAIMER

  • The conditions of installation, operation, using and maintenance of the modules shown in this manual are beyond the controlling range of DAH Solar, lead to any personal injury or property lose during the installation, operation, using and maintenance, and any non DAH Solar product defect caused disputes, DAH Solar does not bear any legal responsibility.
  • Intellectual Property: DAH Solar is not responsible for any infringement of intellectual property rights or other rights of third parties due to the use of component products. The customer does not obtain any intellectual property rights or relevant use authorization for use of the products, whether express or implied.
  • DAH Solar reserves the right to modify the manual, PV products, specifications or product information. The modification of any information may be due to business requirements, technical level or other objective environment, but it does not represent the negation of the original information.
  • Information of this manual is reliable knowledge and experience of DAH Solar, including but not limited to all the above information and advice, but all the above information and related suggestions, whether express or implied, does not represent the only, proprietary methods, also does not pose any safety and quality warranty.

DAH solar 455W Full Black PV Module - QR Code

ANHUI DAHENG ENERGY TECH CO., LTD.
No.1 YaoYuan Road, Luyang District, Hefei City, Anhui , China
Email: dhsolar@dh-solar.cn
Tel: +86-551-65176633
Web: www.dahsolarpv.com