SILEATAIRE 559011010 8in Plasma Downlight User Guide

October 30, 2023
SILEATAIRE

Model # 559011010
Part # SADL-DMJB-PL-LB3-9-CP5-MV-TRIAC-WHSILEATAIRE 559011010 8in
Plasma Downlight USE AND CARE GUIDE
8IN PLASMA DOWNLIGHT

559011010 8in Plasma Downlight

NOTE: Keep your receipt and these instructions for proof of purchase.
WARNING: Shut off the power at the circuit breaker or fuse panel before removing the old fixture, ballast,or fluorescent tubes.
If you are unfamiliar with electrical installations, we recommend you contact a qualified electrician to do the installation.
NOTE: Dispose used products according to local regulation.

PACKAGE CONTENTS

Part Description Quantity
A Fixture 1
B Hole Template 1

SILEATAIRE 559011010 8in Plasma Downlight - PACKAGE
CONTENTS

INSTALLATION

  1. Make sure the power is turned off at the source to the location where the LED downlight (A) will be installed.
    Place the hole template (B) over the desired location and trace the outline with a pencil.
    Cut out the marked opening in the ceiling with a hole saw (not included).
    SILEATAIRE 559011010 8in Plasma Downlight - INSTALLATION
1 NOTE: An opening that is between 6 2/3” and 8 2/3” in diameter is recommended. The factory setting of the spring clips is for a 6 in. recessed can housing.
    Adjust the spring clips by loosening the screws and tighten the screws once the springs are in place (See the number 8 on the fixture) for a 8in. recessed can housing.
    SILEATAIRE 559011010 8in Plasma Downlight - INSTALLATION
2

  2. Press the spring to open the cover of the electrical box.
    Remove one of the knock out holes on the side of the electrical box.
    SILEATAIRE 559011010 8in Plasma Downlight - INSTALLATION
3

  3. Feed the wires from the electrical source through the open knock out hole in the electrical box. Insert the hot, neutral wires from the electrical source into the wire connectors of the black and white wires in the electrical box. Insert the purple wire from the electrical source into the wire connectors of the purple wire in the electrical box if needs dimming function. Close the box.SILEATAIRE 559011010 8in Plasma Downlight - INSTALLATION 4

  4. One at a time, flip the spring clips on the LED downlight (A) up and insert into the opening in the ceiling. Once both spring clips are inside the cut-out, gently push the LED downlight (A) upward until the trim is flush with the ceiling surface. Restore power at the electrical panel. Turn on the light switch to activate the fixture.

ADJUSTING THE COLOR TEMPERATURE OF THE LIGHT

This downlight allows you to customize the color temperature of the light anywhere from warm white to daylight.

  • Choose your favorite correlated color temperature (CCT) from five options: 2700K, 3000K, 3500K, 4000K, or 5000K.
    NOTE: The factory setting for the correlated color temperature (CCT) is 2700K, which is the warmest white light.

  • Choose the desired brightness (lumen output) from three options: 900 lm, 1600 lm, or 2000 lm.
    NOTE: The factory setting for the brightness (lumen output) is 2000 lm

  • Move the toggle switch on the back of the LED light module (A) to make your selection before pushing the LED light module into the recessed can housing.

SILEATAIRE 559011010 8in Plasma Downlight - INSTALLATION
5

SELECTING WORKING MODE

This downlight allows you to choose between two working modes by using your wall switch and flipping it on/off/on within 3 seconds.
TO TURN ON WHOLE SYSTEM: Turn on the light switch to activate the light fixture with green indicator light and disinfection mode.
TO TURN ON DISINFECTION MODE ONLY: Turn off the main down light by wall switch, and turn back on within 3 seconds to active the disinfection only mode.
Cleaning: Every 6 months dust filters should be cleaned. Remove dust covers on both sides and remove dust from the nets. If air volume decreases between cleanings remove cover and clean nets when needed. Replace and secure dust covers after cleaning.
CAUTION: high voltage
CAUTION: This equipment should be inspected frequently and collected dirt removed from it regularly to prevent excessive accumulation that may result in flashover or a risk of fire.
The 8 hr TWA Ozone for this product is 0.013 ppmv when tested in a 30 m3 chamber. Refer to www.ETiSSL.com for more test reports.
WARNING: Carefully read and understand the information given in this manual before beginning the assembly and installation. Failure to do so could lead to electric shock, fire, or other injuries which could be hazardous or even fatal.
Ensure the electricity to the wires you are working on is shut off. Either remove the fuse or turn off the circuit breaker.

  • SUITABLE FOR OPERATION IN AMBIENT NOT EXCEEDING 45°C.
  • SUITABLE FOR DAMP LOCATIONS.
  • MIN 105°C SUPPLY CONDUCTORS.
  • CAUTION-RISK OF SHOCK. DISCONNECT POWER BEFORE SERVICING.
  • STORE IN AMBIENT NOT EXCEEDING 45°C.

NOTICE: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna, increase the separation between the equipment and the receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, and consult the dealer or an experienced radio/TV.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

MAINTENANCE:

See website for Warranty, Troubleshooting or Care and Cleaning details at www.ETiSSL.com.

Questions, problems, missing parts?
Call ETiSSL
Customer Service 8 a.m. – 5 p.m., CST, Monday – Friday
1-855-ETI-SSLI (1-855-384-7754)
www.ETiSSL.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals