AGROWTEK ADi Pumps AgrowDose Intelligent Perstalitic Metering Pumps Instruction Manual
- October 30, 2023
- AGROWTEK
Table of Contents
- Product Models
- Dimensions
- Installation Instructions
- Connecting Pump Tubing
- Connection to Grow Control™ GCX
- Grow NET™ Hubs
- Connection to SXHM Controller
- Cross-Over Cable
- Connection to USB Agrow LINK
- Agrow Dose Batch Master PC Software
- Batch Master Software Setup
- Running a Recipe
- Connection to MODBUS RTU
- Serial Speed & Format
- Supported Commands
- Register Types
- Motor Operation Registers
- MODBUS Holding Registers
- Maintenance
- Replacing Pump Head
- Storage and Disposal
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AGROWTEK ADi Pumps AgrowDose Intelligent Perstalitic Metering Pumps
Instruction Manual
Product Models
Dimensions
Mounting Holes: dia. 0.201”
n = number of pump heads
Installation Instructions
Mount the pump on a vertical wall surface using the holes in the mounting flanges. The center flanges hole may be used to hang and level the pump, however, the corner screw holes should be used for flanges mounting. Use caution to avoid over-tightening the screws and bending the flanges.
A 120Vac wall receptacle is required within 6ft of the pump for the power
adapter.
Do NOT connect the Grow NET port to Ethernet networks.
Connecting Pump Tubing
Each pump has an inlet (suction) and outlet (pressure) tube. Using included barbed tubing connectors, install an inlet tube for each pump into the respective concentrate container, then install an outlet tube to the mixing reservoir or injection manifold.
Shown with optional PBX-100 series injection manifold designed for easy
installation with a re-circulating pump for continuous recycling.
Connection to Grow Control™ GCX
All Grow NET™ devices are connected using standard CAT5 Ethernet cable with RJ-45 connections.
Devices can be connected directly to the Grow NET™ ports on the bottom of the
controller, or through HX8 Grow NET™ hubs. It is typical to simplify cabling
by locating hubs centrally in hall ways and rooms allowing single runs from an
8-port device hub back to a central hub or back to the controller.
Refer to the GCX controller manual for details on adding the device to the system.
Grow NET™ Hubs
HX8 Grow NET ™ hubs expand a single port into eight more ports. Hubs can be daisy-chained to form a network of up to 100 devices per Grow NET™ bus. Individually buered port transceivers provide excellent signal integrity and extended communication strength and range.
Hubs provide up to 1A of power for operating sensors and most relays directly
over the CAT5 cable. A DC jack on the hub provides 24Vdc power to the ports
from the included wall power supply. A terminal block power option is also
available.
Installation Notes
NOTICE
Grow NET™ ports use standard RJ-45 connections but are NOT compatible the
Ethernet network equipment. Do not connect Grow NET™ ports to Ethernet ports
or network switch gear
DIELECTRIC GREASE
Dielectric grease is recommended on RJ-45 Grow NET™ connections when used in
humid environments. Place a small amount of grease onto the RJ-45 plug
contacts before inserting into the Grow NET™ port. Non-conductive grease is
designed to prevent corrosion from moisture in electrical connectors.
- Loctite LB 8423
- Dupont Molykote 4/5
- CRC 05105 Di-Electric Grease
- Super Lube 91016 Silicone Dielectric Grease
- Other Silicone or Lithium based insulating grease
Connection to SXHM Controller
Connect an ADi dosing pump directly to Agrowtek’s SXHM hydroponics sensor to form a powerful, autonomous pH and EC set-point dosing system. Operate a single, dual or quad AgrowDose pump and congure each pump as an EC part or pH up or down part. Automatically maintains pH and EC concentrations with a simple repeating recipie dosing method.
A direct-link connection between a SXHM sensor and ADi pump requires Agrowtek’s cross-over adapter.
IMPORTANT! ONLY use cross-over adapters provided by Agrowtek’s. Do not
use other cross-over adapters or cross-over cables unless they are constructed
exactly as diagramed on the cross-over diagram. Incorrect cross-over adapters
or cables can cause damage to the equipment.
Please see the “MDX” product manual for more information on setting up and installing the MDX mini dosing system.
MDX System Instruction Manual
Cross-Over Cable
A custom cross-over cable can be constructed as an alternative to using the cross-over adapter and two standard, straight Ethernet cables as shown in the diagram above. The cross-over wiring MUST match the diagram below.
Pins 7 & 8 carry 24Vdc power and must be straight through or damage may
result to the equipment.
Connection to USB Agrow LINK
LX1 USB Agrow LINK connects Agrowtek’s devices to a computer’s USB port for:
- Firmware Updates
- Conjuration
- Batch Dosing Control
- More
Perform batch dosing directly from a PC for creating nutrient mixtures, labratory chemical dispensing, food and beverage mixing, and more. Standard FTDI drivers automatically install in Windows for the LX1 link.
Agrow Dose Batch Master PC Software
Batch Master is a free PC software application for directly operating the ADi
dosing pumps through a LX1 USB Agrow LINK. To download the software, please
visit our website at www.agrowtek.com.
Batch Master Software Setup
Setup
To setup and install the free software you must be using a Windows operating
system
- Download the installer from Agrowtek’s website.
- Open the installer and follow the command prompts.
- If you are given a security warning asking permission to modify les (install them,) select YES.
Connect the USB Agrow LINK and allow the drivers to automatically install. Wait until a message is displayed in the task bar in dicatin the device is ready to use (it may take several minutes.) If the device drivers fail to install, you can install them from the Batch Master software.
Driver Installation
If the device drivers have not automatically installed:
- Open the Batch Master program.
- Ignore warnings that advise the Agrow LINK was not detected (press OK.)
- From the top menu bar select: USB AgrowLINK > Install Driver.
- The driver installer will open; follow the command prompts to complete the driver installation.
Detect the Agrow LINK
If your Agrow LINK was not connected before you opened the program, you can
search for it by selecting: USB Agrow LINK > Detect Agrow LINK.
Running a Recipe
Each pump may have a setting for the dose volume (mL) and the ow rate of the pump (mL/min).
To create a batch recipe:
- Set the ow rate for each pump. Most applications will use the pumps at full speed. The speed may be reduced if required for your application.
- Set the volume that each pump should dose.
- Save the recipe if desired by selecting: File > Save. Choose a location and name the le then press “Save.”
Saved recipies may be recalled by selecting: File > Open and choosing a recipe file.
Run a Batch
Once the recipe is congured, it may be “run” by pressing the green “play”
button. The pumps will begin dosing with the rst pump. Once the specied volume
is completed, the next pump will begin. When all pumps have metered the volume
in the recipe, the batch is complete.
Stop Pumps
All pumps may be stopped immediately by pressing the red “stop” button.
Prime
Each pump may be primed for 10 seconds automatically by pressing the “Prime”
button for the respective pump. The pump will operate at the speed selected
allowing the speed to be previewed or tested.
Connection to MODBUS RTU
RS-485 / RS-422
Use the LX2 Mod LINK to connect MODBUS devices to the Grow NET™ port
3.3/5Vdc Serial Bus Compatible.
Include required bus terminating resistors per EIA standard.
Serial Speed & Format
The default serial data format for the LX2 Mod LINK interface is: 19,200 baud, 8-N-1.
Alternate speeds and formats between 9,600 – 115,200 baud may be congured with
the free Agrow LINK PC utility using a LX1 USB Agrow LINK and the cross-over
adapter supplied with the LX2 Mod LINK.
Supported Commands
- 0x03 Read Multiple Registers
- 0x06 Write Single Register
- 0x16 Write Multiple Registers (for motor speeds only)
A request to use a function that is not available will return an illegal function exception.
Register Types
All registers are 16 bits wide with addresses using the standard MODICON protocol. Floating point values use the standard IEEE 32-bit format occupying two contiguous 16 bit registers. ASCII values are stored with two characters (bytes) per register in hexadecimal format.
Motor Operation Registers
Motor Speed
Motors are operated simply by sending the desired speed to each motor’s speed
register. Positive percentages result in CW (forward) rotation while negative
percentages result in CCW (reverse) rotation.
FORWARD: +60 to +100% | REVERSE: -60 to -100% | STOP: 0%
Speeds below 60% may result in a stalled motor and should not be used.
Included power supply is sucient to drive a single motor at a time.
Driving multiple motors simultaneously may cause the power supply voltage to
drop below acceptable levels and put the pump into a fault protection mode
requiring a power cycle. To drive multiple motors reliably, provide 0.5A/Motor
(2.1mm jack, center positive)
Motor Life
Motor life and service intervals can be tracked by observing the pump motors’
accumulated run time which is tracked in seconds in a 32-bit unsigned integer
register for each pump motor.
Timeout
Timeout value (seconds) can be set to shut o all pumps in the even no
communication is receieved from the master device within a set period of time.
MODBUS Holding Registers
Parameter| Function| Range| Type| Access|
Address
---|---|---|---|---|---
Address| Device Slave Address| 1 – 247| 8 bit| R/W| 40001
Serial#| Device Serial Number| ASCII| 8 char| R| 40004
DOM| Date of Manufacture| ASCII| 8 char| R| 40008
HW Version| Hardware Version| ASCII| 8 char| R| 40012
FW Version| Firmware Version| ASCII| 8 char| R| 40016
**** Motor Speed (%)| Pump 1| **** 0 – 100| 16 bit,
unsigned| **** R/W| 40101
Pump 2| 16 bit, unsigned| 40102
Pump 3| 16 bit, unsigned| 40103
Pump 4| 16 bit, unsigned| 40104
Pump 5| 16 bit, unsigned| 40105
Pump 6| 16 bit, unsigned| 40106
Timeout (seconds)| Turn off pumps if no communication| 0 – 32767| 16 bit,
unsigned| R/W| 41001
**** Accumulated Run Time (seconds)| Pump 1| **** Unsigned Int|
**** 32 bit, unsigned| **** R| 49001
Pump 2| 49003
Pump 3| 49005
Pump 4| 49007
Pump 5| 49009
Pump 6| 49011
A request to read or write a register that is not available will return an illegal address error (0x02.)
Maintenance
Agrow Dose pumps are low maintenance and have a durable DC motor and non-servi cable gear box for very long life. Pump tubing is non-servi cable and the economical pump heads are replaced as units with new rollers, tubing and lubricant. Head replacement does not require any tools and takes only moments.
Replacing Pump Head
Pump heads are replaceable when the tubing wears out from extended use. Pump heads typically last 12-24 months depending on the volumes being dispensed and frequency of use. When the tubing begins to leak, replacement is a simple process:
- Rotate the pump head counter-clockwise 1/8 turn
- Slide the head off of the motor shaft.
Replace in reverse order.
Storage and Disposal
Storage
Store equipment in a clean, dry environment with ambient temperature
between10-50°C.
Disposal
This indsutrial control equipment may contain traces of lead or other metals
and environmental contaminants and must not be discarded as unsorted municipal
waste, but must be collected separately for the purpose of treatment, recovery
and environmentally sound disposal. Wash hands after handling internal
comonents or PCB’s
Warranty
Agrowtek Inc. warrants that all manufactured products are, to the best of its knowledge, free of defective material and workmanship and warrants this product for 1 year from the date of purchase. This warranty is extended to the original purchaser from the date of receipt. This warranty does not cover damages from abuse, accidental breakage, or units that have been modied, altered, or installed in a manner other than that which is specied in the installation instructions. Agrowtek Inc. must be contacted prior to return shipment for a return authorization. No returns will be accepted without a return authorization. This warranty is applicable only to products that have been properly stored, installed, and maintained per the installation and operation manual and used for their intended purpose. This limited warranty does not cover products installed in or operated under unusual conditions or environments including, but not limited to, high humidity or high temperature conditions. The products which have been claimed and comply with the aforementioned restrictions shall be replaced or repaired at the sole discretion of the Agrowtek Inc. at no charge. This warranty is provided in lieu of all other warranty provisions, express or implied. It is including but not limited to any implied warranty of tness or merchantability for a particular purpose and is limited to the Warranty Period. In no event or circumstance shall Agrowtek Inc. be liable to any third party or the claimant for damages in excess of the price paid for the product, or for any loss of use, inconvenience, commercial loss, loss of time, lost prots or savings or any other incidental, consequential or special damages arising out of the use of, or inability to use, the product. This disclaimer is made to the fullest extent allowed by law or regulation and is specically made to specify that the liability of Agrowtek Inc. under this limited warranty, or any claimed extension thereof, shall be to replace or repair the Product or refund the price paid for the Product.
Agrowtek Inc. | www.agrowtek.com | Technology to Help You Grow™
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>