Assembly instructions for Designer Radiators
Please read the instructions carefully, before starting assembly.
– The radiator must be installed by a qualified plumber or another competent
specialist.
– Note that the dimensions and panel-/pipe layout of the radiator may differ
from the respective illustrations.
– Do not dispose of the packaging until you have secured small parts such as
wall brackets and mounting accessories.
– We recommend wearing suitable protective clothing such as gloves and
reinforced work shoes for assembly.
-
Determination and scope of use of the products
– The radiators are designed to be used in a closed central heating system. -
Maximimum operating pressure
– Please note the maximum operating pressure specified in the assembly dimension table. Use above this level can damage the radiator and void any warrantee. -
Scope of delivery of a standard packaging:
– 1 pc. radiator|
---|---
– 1 pc. Air vent (A)|
– 1 pc. Blanking plug (B)|
– 4 pcs. Masonry wall plug(C)|
– 4 pcs. Screws (D)|
– 4 pcs. Washers (E)|
– 4 pcs. Wall bracket|
4. eneral assembly instructions
– Check the contents of the packaging for completeness.
– Make sure that you have the appropriate connection fitting.
– Before drilling the holes, make sure there are no hidden water, electric or
gas lines behind the wall.
– The distance between the Floor and the bottom of the radiator should be at
least 150 mm so that efficient heating and ventilation is possible.
– Prepare the necessary tools before and make sure that there is enough space
and a clean, dry environment for assembly.
Make sure that you are using the correct type of wall for mounting. The wall
plugs supplied are only suitable for solid masonry. For other wall types
please obtain the correct wall fixings.
– The specified dimensions are for the main mounting holes on the brackets.
Some brackets also require a second fixing hole.
Typical connection options
Assembly diagram:
Assembly Instructions:
- If you use the supplied masonry wall plugs, use the dimensions for the main holes (see assembly dimension table) to drill 4 holes with a depth of approx. 60 mm and a diameter of 8 mm.
- Place the wall plugs (C) in the drilled holes (only in solid walls).
- Attach the screw (D) and washer (E) to the bracket for fixing to the wall. Be careful not to overtighten the screw.
- Some radiators are fitted with a baffle. These radiators will be marked with a sticker to advise the correct way up to install the radiator. To be sure you can look inside the horizontal tubes, the baffle will be visable and must be at the bottom. If both horizontal tubes are clear the baffle is not required on that type of radiator and the direction of installation is universal.
- Hang the radiator on the bracket.
- Mount the supplied air valve (A) and the blanking plug (B) in the upper threaded openings of the radiator.
- Connect the flow and return to the selected side of the radiator using radiator valves (not included). Seal the threads watertight. We recommend use of PTFE tape or similar sealing product on all connections. Leaks as a result of incorrect sealing are not covered under the warrantee.
- How to first fill and vent the radiator:
– Open the air vent
– Slightly open the inlet valve (about 10%) while leaving the outlet valve totally closed.
– Allow the system to fill the radiator. If possible fill without use of the heating pump, it is important that the radiator is filled slowly.
– When the radiator has been filled close the air vent.
– Open both inlet and outlet valves totally and use the heating system for about 2 hours.
– Totally close both inlet and outlet.
– Open the air vent and let out all air.
– This should clear all air from the radiator. If you are still having problems, on some systems it may be necessary to fit an automatic air vent.
Care and use
– After installation, you MUST be absolutely certain that the system has been
RINSE thoroughly before using it to flush out metal, flux and foreign debris.
The system must also be completely vented.
– To prevent internal rust and limescale formation, a suitable inhibitor
should be added to the central heating system when filling.
– Clean the radiator with a soft, damp cloth. Never use a scouring pad,
scouring agent or chemical cleaning agent.
Troubleshooting
– If some pipes in your radiator are not warm, check and vent them again using
the air vent. If some tubes persist in remaining cold the radiator may have
been filled too quickly. Try to run it on its own to force the air out of the
tube. If this does not work it may be necessary to drain and refill again
slowly. – If the radiator is generally patchy heat or takes a long time to
heat it may have been fitted upside down. To check lock off the radiator on
both valves, then drain water from the air valve until the top tube is empty
and you are able to remove the air valve and blanking nut. Look inside the
tube, it should be totally clear. If you can see the baffle it is on the wrong
way up. If the radiator is fitted the correct way it may be necessary to
rebalance the heating system.
Troubleshooting for electric radiators
It is normal upon first use that you may see a small amount of water discharge
from the pressure valve mounted on the side at the top of the radiator. After
a short time all panels on the radiator should heat up. If this does not
happen, it may be necessary to top up the radiator. To do this, place the
radiator on its side and undo the top side nut. Top up with normal water and
replace.
Installation dimension table for bathroom radiators
Model / label
(See packing)| Dril hole
spacing
horizontal “X”| Dril hole
spacing
vertical “f’| Hub spacing
(NA)| Connection type| Max. Operatirg
pressure in bar| Assembly diagram
PU / MT / P20| 50 mm| II – 220 mm| 50 mm| 50 mm connection| 4| 4
PUE / MTE / P20E| 50 mm| 11 – 220 mm| | electric| 4| 4
MAG / K2D| 13 – 55 mm| H – 240 mm| 13 – 30 mm| default| 10| 9
SC/HE/K3| 13 – 300 mm| H – 156 mm| 50 mm| Center connection| 10| 1
FORS / NOPR / NES| B – 50 mm| II – 178 mm| 13 – 50 mm| default| 10| 4
SD / PAR| 200 mm| 11 – 180 mm| 50 mm| Center connection| 10| 4
PAS / MAPR / P2| 13 – 50 mm| 11 – 220 mm| 13 – 50 mm| default| 4| 4
PASD / MAPRD / P2D| 13 – 200 mm| H- 145 mm| 13 – 50 mm| default| 4| 3
VE/SI/PU| B – 30 mm| H – 180 mm| 50 mm| Center connection| 10| 4
FOU / NOT / FOO| 50 mm| H – 178 mm| 50 mm| 50 nil connection| 10| 4
CHA / KAL / CAD| El – 50 mm| li – 140 mm| 8 – 50 mm| default| 4| 4
QC / CHG / Cl| 13 – 200 mm| H – 196 mm| B – 50 mm| default| 10| 1
CLC/CHG/C1 MA| 13 – 200 mm| H – 196 mm| 50 mm| Center connection| 10| 1
VEL / CHGB / C2| 8 – 200 mm| H – 196 mm| 13 – 50 mm| default| 10| 1
VEL / CHGB / C2 MA| 8 – 200 mm| II – 196 mm| 50 mm| Center connection| 10| 1
RO/BAC/C3| 8 – 120 mm| 11 – 172 mm| 13 – 50 mm| default| 10| 1
UR/ VER /C4| El – 30 mm| H – 164 rnm| 13 – 30 mm| default| 10| 4
JAC / CEC / C5| 100 mm| II – 124 mm| 50 mm| 50 mm connection| 5| 1
SVC / PVC / C6| 13 – 32 mm| 11 – 120 mm| 13 – 32 mm| default| 5| 4
SCC / PRC / C7| 13 – 60 mm| II – 300 mm| 13 – 60 mm| default| 5| 4
B0/MA/C8| 72 mm| 11 – 168 aim| 72 mm| 72 mm connection| 10| 4
SI/CEP/HE| 50 mm| H – 124 mm| 50 mm| Center connection| 10| 4
ZE / RO| 13 – 160 mm| H – 170 mm| 13 – 30 mm| default| 10| 1
PO/FO| 8 – 180 mm| H – 165 mm| 8 – 50 mm| default| 10| 1
LU/FI/K4| B – 76 mm| 11 – 180 mm| 13 – 80 mm| default| 10| 4
LUE / FIE / K4E| 8 – 76 mm| H – 180 mm| | electric| 10| 4
POR / PRI/ 30K| 13 – 160 mm| H-2Bmm| 13 – 30 mm| default| 10| 1
PORE / PRIE / JOKE| El – 160 mm| 11 – 223 mm| | electric| 10| 1
Mounting dimensions table for room heaters →
Mounting dimensions table for room heaters
Model / label (See Wag)| 001 tole
spacing
Wants! if| Di11 hole
macing
verbal ‘Y’| Hub sPacing
(HA)| Connection tyre| Ma
Operating
pressure in
bar| Assembly
diagram
FOR / NO/ BR1| B- 203mm| H – 100 mm| H – 50 mm| default| 10| 3
FORD / NCO / RID| B • 208 mm| ti – 200 mm| II – SO mm| &WE| 10|
FORH i NCH / earn| B- 100imi| H- 163 imi| B- 50mm| default| 10| 3
FORCH / NOOH / MICH| B- 200 men| H – 178 mm| B- 50mm| default| 10|
FORM / NOM / BRIM| B – 208 mm| H – 105 mm| H – 50 mm| default| 10| 3
FORM° I NOMD / ERIMO| El. 208 mm| H – 200 mm| II – SO mrn| default| 10|
FORT / NOE / BRO.| B – 103 Ern| H – 50 mm| H – 50 mm| default| 10| 2
SAT/AT/TA| B • 80 men| H-50 mm| H-SOmm| defaJlt| 4|
TM i AT4 / AT4| B- 167mm| H-50mm| H-50mm| default| 4| 2
SHW/HW/OX| B – 250 mrn| H – 110 mm| H – SO mrn| default| 4|
SWIM / NNW am| B – 250 nvn| H – BO nvn| H – 50 mm| default| 4|
SHWDS / HWDS / OXDS| B • 250 mrn| H – 150 mrn| H – 50 mrn| default| 4|
strmxis / rivals 1 coots| B – HO awn| H – 720 nvn| B – 50mm| default| 4| 3
SHWX / HWX / 0)3(| 13 – 250 rrrn| H- 110mm| H – SO mm| default| 4|
SWIM( / IMMO COCO| B – 250 mm| H – 150 mm| H – 50 mm| default| 4| 3
SHVOIX / 111611X / OXIIX| B- 192 mm| H – 200 mm| B- 50mm| default| 4|
%mom / weioroc i mom| B – HO mm| H – 215 imn| B – 50mm| default| 4| 3
SHWit / HUN I Om,| B – 250 mot| H- 110mm| H – SO mm| default| 4|
SHWPDX /HMCO( / OXPDX| B – 250 mm| H – 150 mm| H – 50 mm| default| 4| 3
StiV64 / MWM / OXM| B- 175 mm| H- 110mm| H – SO mm| default| 4|
SHWE / HWE / OXE| B – 250 =I| H – 110 urn| –| eletic| 4| 3
SHWV / HWY / OXV| B – 250 mrn| H- 110mm| H – SO mm| default| 4|
SAUR / 01 / TR| B – 150 mm| H – 50 mm| 50mm| center connectlOn| 10|
SAURD / CHD / TRD| B- 150 mm| H – SD mm| 50mm| center comedian| 10|
SAURE / CHE i ‘IRE| 204 mm| H – 50 mm| 50mm| center connection| 10| 2
SAURC 1 O K / TRC| 182 mm From
corner| ti • 50 mm| SO mm| center cconectico| 10|
211RM / CHM / TRM| B – 150 mm| H – 50 mm| 50mm| center connecban| 10| 2
SAURCM / CHCM / TRO4| B- 145 mm| ti • 50 rrrn| 50mm| ceder cconecttan| 10|
1S/SU/KA| B – 100 mil| H – 100 awn| H – 100 mm| default| 10| 2
ESQ / SUS / KAS| B • 100 rrrn| ti • 100 mrn| H – 100 mm| default| 10|
OU/VU/ER| B – 160 mm| H – 100 mm| H – 1E0 mm| default| 10| 2
DUV I VUQ / ERQ| B- 165 mm| H – 100 men| 1-1- 100 mm| default| 4|
91101V101 MI (H . 500)| B – 200 mit| 375 mm| 430 nye| default| 4| 3
SV10 / V10 / MI (H . 650)| El – 200 mm| 525 mm| 550 mm| default| 4|
DUE /WE/ ERE| B- 160 mm| H- 100 =I| –| electric| 10| 2
SHWHE / HYA-E / 03316| 13 – 105 mm| H – 220 men| –| electric| 4|
TIME / GME / ECHE| B- 300mm| H-MOmm| –| electnc| 10| 1
FORCE/NOTE/BRINE| B- 100 men| H – 163 mm| –| electric| 10|
STP /OUP/ S1P| B-147=| H-104=| H- 104 mm| default| 10| 2
T122 / GA.7.2 / K122| 8 – 85 mm| H – 50 mm| H – SO mm| default| 10|
T1D22 i GAD22 FKID22| B-85 mm| H – SOmm| H – 50 mm| default| 10| 2
111122 / GAH22 / K11-122| B – 203 mm| H- 155 mm| B- 50mm| default| 10|
T1CH22 i GADH22 i ICICH22| B – BO mm| H – 155 mm| B – SO mm| default| 10| 3
V0422
Documents / Resources
|
XIMAX 4164BTU Oceanus Designer
Radiator
[pdf] Instruction Manual
4164BTU, 4164BTU Oceanus Designer Radiator, Oceanus Designer Radiator,
Designer Radiator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>