Clarke CON305 110V 12 Inch Ventilator Instruction Manual

June 4, 2024
Clarke

Clarke - logo CON305 110V 12 Inch Ventilator
Instruction ManualClarke CON305 110V 12 Inch
Ventilator 12” VENTILATOR
MODEL NO: CON305 (110V)
PART NO: 3230480

INTRODUCTION

Thank you for purchasing this CLARKE Ventilator which is designed for indoor use in an industrial environment.
Read this manual carefully, in doing so you guarantee the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.

SAFETY WARNINGS

Make sure that you read, understand, and comply with the following warnings.
POSITIONING
Be aware that the suction capability is considerable. Do not position the ventilator where it will blow dust or hazardous fumes at people.
DO NOT place the ventilator close to any wet surface. DO NOT place against any surface such as a wall, door or furniture etc.
DO NOT place the ventilator on a raised surface or anywhere it could topple over.
Only use the ventilator in a level position.
Ensure that the intake grille cannot be blocked by curtains or other fabrics. Do not allow loose clothing, long hair, jewelry etc. to be drawn into the intake side of the fan.
DO NOT operate the ventilator in explosive atmospheres such as in the presence of flammable liquids, gases or dust such as in a paint spray booth.
Electric motors create sparks that may ignite dust or fumes.
DO NOT cover the fan or obstruct the air inlet and outlet sections of the ventilator.
DO NOT get the ventilator wet or use it in areas of high condensation.
DO NOT allow the power cable to touch hot surfaces.
DO NOT operate without the safety grills secured in position.
PERSONNEL SAFETY
DO NOT use the ventilator when you are tired or under the influence of alcohol, drugs or intoxicating medication.
DO NOT stand on the ventilator.
DO NOT use the ventilator with wet hands or when there is water on the power cable.
Young children must be kept away unless supervised.

ELECTRICAL SAFETY
Inspect the power cable/plug for damage/looseness. Do not use the ventilator if the power cable is damaged.
Make sure that the voltage on the product label is the same as the voltage of the power supply. If in doubt, consult a qualified electrician.
DO NOT abuse the electrical cable. Do not use the cable for pulling or unplugging the ventilator.
Keep the cable away from sources of heat, oil, sharp edges or moving parts.
Damaged or tangled cables increase the risk of electric shock.
DO NOT use extension cables with this ventilator.

SERVICE & REPAIRS
Check that the ventilator is in good working order. Take immediate action to have it repaired or any damaged parts replaced.
DO NOT attempt to repair the ventilator yourself. Always contact the CLARKE service department who will use recommended parts only. Unapproved parts may be dangerous and will invalidate your warranty.

ENVIRONMENTAL RECYCLING POLICY
By purchasing this product, the customer is taking on the obligation to deal with its safe disposal in accordance with the Waste Electrical and Electronic Equipment regulations  (WEEE).
In effect, this means that this product must not be discarded with general household waste but according to the laws governing Waste Electrical and Electronic Equipment  (WEEE) at a recognized disposal facility.

GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused, tampered with, or not used for the purpose for which it was intended.
Faulty goods must be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not affect your statutory rights.

**ELECTRICAL CONNECTIONS

**

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO A POWER SUPPLY.

This product can be connected to one of the following power supplies:

  • 110V generator
  • 110V isolating transformer
  • 110V site supply
  • 230V generator via a 110V transformer.

Connecting it to any other power source may cause damage.
This product includes a fitted industrial plug to BS-EN 60309 and a cable for use with a 110 volt supply. On no account must a 230V, 13amp (BS1363) plug be used.
If using a portable 110V transformer make sure it has a rated capacity sufficient to take the load of the fan. Should the plug need changing at any time, ensure that a plug of the identical specification is used and proceed as follows:

  1. Undo the socket screws & remove the rear section.
  2. Rotate the cable clamp clear of the terminals.
  3. Feed the cable through the rear gland in the plug.
  4. Remove the cable sheath to the required lengths as shown in the diagram.
  5. 5. Terminate the correct wires in the correct terminal blocks as shown.
  6. Remove the cable clamp screws. Clip the cable clamp back into position and place the clamp around the outer sheath of the cable. Replace the screws and tighten until the cable is securely held.
  7. Replace the rear cover and tighten the cover screws.

Clarke CON305 110V 12 Inch Ventilator - Figure 1

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

BEFORE USE

Before commencing assembly, check for damage and or shortages, etc, any damage or shortage should be reported to your CLARKE dealer where the ventilator was purchased.
This ventilator can be used with CLARKE 12” diameter retractable ducting sold separately in 5-meter lengths as follows:
Yellow (3230481)

Clarke CON305 110V 12 Inch Ventilator - Figure 2

  1. Before use, attach the ducting to the discharge end of the ventilator as shown, secured with the tie cord provided.
  2. Place the ventilator in a level position on a flat surface and at a safe distance from flammable materials.
  3. The ventilator is operated by the ON/OFF switch.
  4. Connect the ventilator to a suitable power outlet.

CARE & MAINTENANCE

WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE PERFORMING ANY CLEANING OR MAINTENANCE TASKS. REPAIRS SHOULD BE CARRIED OUT BY THE CLARKE SERVICE DEPARTMENT.

Clean the ventilator with a soft damp cloth, Do not use solvents or abrasives.
If used in spaces with high dust content, clean the guards and fan blades by vacuuming or wiping. Remove the end guard to gain access to the blades.
REPLACE GUARD BEFORE RE-CONNECTING TO POWER SUPPLY.
No other maintenance is required, should you discover any problem with the ventilator return it to the CLARKE service department for repair.
Should the fan fail to operate, check the power supply and that the fuse in the plug has not blown? Abnormal noise while the fan is running may occur if the fan is not standing on a level surface.

SPECIFICATIONS

Model CON305 (110v)
Product dimensions complete (L x W x H) 375 x 386 x 430 mm
Drum diameter 380 mm
Fan diameter 300 mm
Product weight 15.35kg
Power supply 110V/50Hz
Electrical Insulation class I
Ingress protection rating IP54
Operating temperature range 20 to 50 C
Sound power level 69 dB
Rpm@optimum energy efficiency 2800 rpm
Flow rate@full speed 3900 m3 /h
Rated air flow@overall efficiency point 2379.7 m3 /h
Rated air flow@optimum energy efficiency 39.7 m3 /s
Total pressure 385 Pa
Static pressure 236.1 Pa
Overall efficiency 51.80%
Measurement category C
Efficiency category Static
Efficiency grade 40
Rated motor input power @ optimum energy efficiency 500W
Specific Ratio  (EU no 327/2011) N/A

DECLARATION OF CONFORMITY

Clarke CON305 110V 12 Inch Ventilator - Certificate

A SELECTION FROM THE VAST RANGE OF

Clarke CON305 110V 12 Inch Ventilator - Figure 4| QUALITY PRODUCTS AIR COMPRESSORS
From DIY to industrial, Plus air tools, spray guns and accessories.
GENERATORS
Prime duty or emergency standby for business, home and leisure.
POWER WASHERS
Hot and cold, electric and engine driven – we have what you need
WELDERS
Mig, Arc, Tig and Spot.
From DIY to auto/industrial.
METALWORKING
Drills, grinders, and saws for DIY and professional use.
WOODWORKING
Saws, sanders, lathes, mortisers, and dust extraction.
HYDRAULICS
Cranes, body repair kits, and transmission jacks for all types of workshop use.
WATER PUMPS
Submersible, electric, and engine drove for DIY, agriculture, and industry.
POWER TOOLS
Angle grinders, cordless drill sets, saws, and sanders.
STARTERS/CHARGERS
All sizes for car and commercial use.| Clarke CON305 110V 12 Inch
Ventilator - Figure 4
---|---|---

PARTS & SERVICE: 0208 988 7400
Parts Enquiries Parts@clarkeinternational.com
Servicing & Technical Enquiries Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335 IIIdin DNA ran my INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeinternational.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals