INTRODUCTION

Thank you for purchasing this CLARKE Ventilator which is designed for indoor or outdoor use in an industrial environment.
Read this manual carefully, in doing so you guarantee the safety of yourself and that of others around you, and you can look forward to your purchase giving you long and satisfactory service.

SAFETY WARNINGS

Make sure that you read, understand, and comply with the following warnings.
POSITIONING
Be aware that the suction capability is considerable. Do not position the ventilator where it will blow dust or hazardous fumes at people.
DO NOT place the ventilator close to any wet surface. DO NOT place against any surface such as a wall, door, furniture, etc.
DO NOT place it on a raised surface or anywhere the fan could topple over.
Only use in a level position.
Ensure that the intake grille cannot be blocked by curtains or other fabrics. Do not allow loose clothing, long hair, jewelry, etc. to be drawn into the intake side of the fan.
DO NOT operate the ventilator in explosive atmospheres such as in the presence of flammable liquids, gases, or dust such as in a paint spray booth.
Electric motors create sparks that may ignite dust or fumes.
DO NOT cover the fan or obstruct the air inlet and outlet sections of the ventilator.
DO NOT get the ventilator wet or use it in areas of high condensation.
DO NOT allow the power cable to touch hot surfaces.
ALWAYS make sure the brakes are engaged before operating.
DO NOT operate without the safety grills secured in position.

PERSONNEL SAFETY
DO NOT use the ventilator when you are tired or under the influence of alcohol, drugs, or intoxicating medication.
DO NOT stand on the ventilator.
DO NOT use the ventilator with wet hands or when there is water on the power cable.
Young children must be kept away unless supervised.

ELECTRICAL SAFETY
Inspect the power cable/plug for damage/looseness. Do not use the fan if the power cable is damaged.
Make sure that the voltage on the product label is the same as the voltage of the power supply. If in doubt, consult a qualified electrician.
DO NOT abuse the electrical cable. Do not use the cable for pulling or unplugging the fan.
Keep the cable away from sources of heat, oil, sharp edges, or moving parts.
Damaged or tangled cables increase the risk of electric shock.
DO NOT use extension cables with this ventilator.

SERVICE & REPAIRS
Check that the fan is in good working order. Take immediate action to have it
repaired or any damaged parts replaced.
DO NOT attempt to repair the ventilator yourself. Always contact the CLARKE
service department who will use recommended parts only. Unapproved parts
may be dangerous and will invalidate your warranty.

ENVIRONMENTAL RECYCLING POLICY
By purchasing this product, the customer is taking on the obligation to deal with its safe disposal in accordance with the Waste Electrical and Electronic Equipment regulations (WEEE).
In effect, this means that this product must not be discarded with general household waste but according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognized disposal facility.

GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused, tampered with, or not used for the purpose for which it was intended.
Faulty goods must be returned to their place of purchase, no product can be returned to us without prior permission.
This guarantee does not affect your statutory rights.

ELECTRICAL CONNECTIONS

WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO A POWER SUPPLY.

This product can be connected to one of the following power supplies:

  • 110V generator
  • 110V isolating transformer
  • 110V site supply
  • 230V generator via a 110V transformer.

Connecting it to any other power source may cause damage.
This product includes a fitted industrial plug to BS-EN 60309 and a cable for use with a 110 volt supply. On no account must a 230V, 13amp (BS1363) plug be used.
If using a portable 110V transformer make sure it has a rated capacity sufficient to take the load of the fan.
Should the plug need changing at any time, ensure that a plug of the identical specification is used and proceed as follows:

  1. Undo the socket screws & remove the rear section.
  2. Rotate the cable clamp clear of the terminals.
  3. Feed the cable through the rear gland in the plug.
  4. Remove the cable sheath to the required lengths as shown in the diagram.
  5. Terminate the correct wires in the correct terminal blocks as shown.
  6. Remove the cable clamp screws. Clip the cable clamp back into position and place the clamp around the outer sheath of the cable. Replace the screws and tighten until the cable is securely held.
  7. Replace the rear cover and tighten the cover screws.

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

BEFORE USE

Before assembly, check for damage and or shortages, etc, any damage or shortage should be reported to your dealer where the fan was purchased.
Your ventilation fan should be supplied with the following parts:

  • 4 x castor (2 with brakes)
  • 16 bolts, 16 nuts, 16 spring washers, and 32 flat washers.

Clarke CON500 110V 20 Inch Ventilation Fan - 3

Bolt the castor assemblies to the frame as shown using the fastenings supplied. Install the castors with brakes at one end of the frame.
This ventilator will be used with CLARKE 20” diameter retractable ducting available in 5-meter lengths sold separately as follows: Yellow (3230286) or Orange (3230243)

Clarke CON500 110V 20 Inch Ventilation Fan - 4

  1. Before use, attach the ducting to the discharge end of the ventilator as shown, secured with the tie cord provided.
  2. Place the ventilator in a level position on a flat surface and at a safe distance from flammable materials.
  3. Set the angle of tilt as required using the hand knob shown.
  4. Connect the ventilator to a suitable power outlet.
  5. Always apply the brakes before operating the ventilator.
  6. The ventilator is operated by the ON/OFF switch.

CARE & MAINTENANCE

WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE PERFORMING ANY CLEANING OR MAINTENANCE TASKS. REPAIRS SHOULD BE CARRIED OUT BY THE CLARKE SERVICE DEPARTMENT.
Clean the ventilator with a soft damp cloth, Do not use solvents or abrasives.
If used in spaces with high dust content, clean the guards and fan blades by vacuuming or wiping. Remove the end guard to gain access to the blades.
REPLACE GUARD BEFORE RE-CONNECTING TO POWER SUPPLY.
No other maintenance is required. Should you discover any problem with the ventilator return it to the CLARKE service department for repair.
Should the fan fail to operate, check the power supply and that the fuse in the plug has not blown? Abnormal noise while the fan is running may occur if the fan is not standing on a level surface.

SPECIFICATIONS

Model CON500 (110v)
Product dimensions (D x W x H) 675 x 485 x 770 mm
Fan diameter 495 mm
Tilt range 3600
Power supply 110V/50Hz
Duty Cycle Classification: Si (continuous)
Electrical Insulation Class I
Ingress Protection Rating IP 54
Operating temperature range -20 to 50°C
Product Weight 43 kg
Sound Power Level 74 dB
Fan rpm @ optimum energy efficiency 1400 rpm
Rated flow rate@full speed 9900 m³/h
Rated airflow @ overall efficiency point 1.0546 m³/h
Rated air flow @ optimum energy efficiency 1.37 m³/s
Rated pressure @ optimum energy efficiency 217.91 Pa
Total pressure (at overall efficiency point) 400 Pa
Static pressure (at overall efficiency point) 436.4 Pa
Rated motor power @ optimum energy efficiency 800W
Overall efficiency 55.%
Measurement category C
Efficiency category Static
Efficiency grade 40
Specific Ratio (EU no 327/2011) N/A

DECLARATION OF CONFORMITY

Clarke CON500 110V 20 Inch Ventilation Fan - 5

Clarke CON500 110V 20 Inch Ventilation Fan - 6

PARTS & SERVICE: 0208 988 7400
Parts Enquiries Parts@clarkeinternational.com
Servicing & Technical Enquiries Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeinternational.com 

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals