ACDC DYNAMIC 6FM250G-12 Gel Series Battery Owner’s Manual

October 30, 2023
ACDC DYNAMIC

ACDC DYNAMIC 6FM250G-12 Gel Series Battery

Product Information

The Gel Series Battery is a high-performance battery that is specially designed to operate under extreme weather conditions. It is made with strong grids, high purity lead, and patented gel electrolyte, which makes it ideal for use in a variety of applications. The battery has a 15-year design life, rapid charging acceptance, and floating or cyclic endurance.

General Features:

  • Designed for power supply under extreme weather conditions
  • Made with AGM or PVC separator
  • Rapid charging acceptance and floating or cyclic endurance
  • 15-year design life
  • Can be used in a variety of applications

Construction:

  • Gel electrolyte
  • Strong grids
  • High purity lead
  • AGM or PVC separator

Specification:

  • Battery Model: 6NFSMB250-G1/212Volt 250Ah
  • Nominal Voltage: 12V
  • Rated Capacity (10 Hour Rate): 250Ah
  • Cells Per Battery: 6
  • Internal Resistance: 68Kg
  • Max. Discharge Current: 2000A (5s)
  • Floating Design Life @ 25 (77 ): 15 years
  • Capacity @ 25 (77 ): 250Ah
  • Capacity Affected by Temp (10 HR): 40 (104 ) 102%
  • Self Discharge @ 25 (77 ): After 3 months storage – 93%, After 6 months storage – 85%, After 12 months storage – 65%
  • Charge Method @ 25 (77 ): Constant voltage charge

Dimensions:

  • Length: 520mm
  • Width: 268mm
  • Height: 220mm
  • Total Height: 240mm
  • Approx Weight: 68Kg

Usage Instructions:

  • Avoid short circuit
  • Do not charge in a sealed container
  • Keep sparks and flame away
  • Cycle Use: Charge at 14.5-14.9V
  • Standby Use: Charge at 13.6-13.8V
  • Initial charging current should be less than 75A

Note : For detailed information on charging voltage and temperature, discharge characteristic curve, and cycle service life in relation to depth of discharge, please refer to the user manual.

Gel series is specially designed for power supply under extreme weather condition.It can be designed with AGM or PVC separator, byusing strong grids, high purity lead and patented Gel electrolyte,With 15-year design life,ait has rapid charging acceptance and floating or cyclic endurance.

Application

  • Emergency Power System
  • Communication equipment
  • Telecommunication systems
  • Uninterruptible power supplies
  • Solar energy, wind energy storage system
  • Power tools
  • Alarm system
  • Marine equipment
  • Medical equipment
  • Fire and Security System

General Features

  • Heavy Duty Grid
  • Mechanized assembly
  • Non-spillable construction
  • High Reliability and Stability
  • Sealed and Maintenance-free
  • Long Life and low self-discharge design

Construction

  • Positive……..Lead dioxide
  • Electrolyte……..Sulfuric acid
  • Separator……..PVC or AGM
  • Container……..ABS(UL94-HB) / Flame Retardant ABS (UL94-V0)
  • Positive……..Lead dioxide
  • Negative……..Lead
  • Safety Valve……..EPDR
  • Terminal……..Coppe

Specification

Battery Model

| Nominal Voltage| 12V
---|---|---
Rated capacity (10Hour rate)| 250Ah
Cells Per battery| 6

Dimension

| Length| Width| Height| Total Height
520mm| 268mm| 220mm| 240mm
Approx Weight| 68Kg
Internal Resistance|  |  |  | Full charged at 25| (77| ): Approx 2m|  |  |  |
Max.discharge current| 2000A(5s)
Floating design life @ 25  (77  )| 15 years

Capacity @ 25  (77  )

| 10Hour rate(25A/10.8V)| 5Hour rate(36.1A/10.5V)| 3Hour rate(46.8A/10.5V)| 1Hour rate(96.2A/10.5V)
250Ah| 180.6Ah| 140.6Ah| 96.2Ah

Capacity affected by Temp(10 HR)

| 40| (104| )| 25  (77  )|  | 0  (32| )| -15| (5| )
102%| 100%| 85%| 65%

Self Discharge @ 25  (77  )

| After 3 months storage| After 6 months storage| After 12 months storage
93%| 84%| 65%

Charge method @ 25  (77 )

| Cycle Use| 14.5-14.9V (Initial charging current less than 75A)
Float Use| 13.6-13.8V

Dimension

Outer Dimension(mm) /Terminal Type(mm)

Constant Current(Amp) and Constant Power(Watt) Discharge Table at 25°C (77°F)

F.V / TIME 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h

9.60V

| A| 900.00| 550.00| 437.50| 287.50| 150.00| 87.50| 65.00| 52.50| 43.85| 28.96| 27.50| 14.25
W| 9540.00| 5841.00| 4681.25| 3105.00| 1635.00| 953.75| 715.00| 577.50| 482.40| 321.44| 305.25| 160.31

10.20V

| A| 825.00| 552.08| 402.08| 272.92| 155.00| 83.96| 63.75| 50.00| 43.02| 28.50| 26.25| 14.00
W| 8992.50| 6128.12| 4483.23| 3070.31| 1743.75| 948.73| 720.38| 567.50| 488.29| 323.48| 297.94| 158.90

10.50V

| A| 765.10| 527.50| 375.00| 264.58| 150.00| 82.29| 62.50| 47.50| 42.50| 28.13| 25.75| 13.83
W| 8416.15| 5934.38| 4237.50| 3016.24| 1710.00| 942.24| 715.63| 546.25| 488.75| 323.44| 296.13| 158.99

10.80V

| A| 696.67| 504.17| 350.00| 252.50| 145.00| 80.21| 61.25| 46.67| 40.63| 27.40| 25.00| 13.65
W| 7663.33| 5747.50| 4007.50| 2916.38| 1674.75| 926.41| 710.50| 543.67| 473.28| 319.16| 291.25| 159.02

11.10V

| A| 602.50| 475.00| 325.00| 235.00| 137.50| 78.13| 58.75| 45.83| 38.85| 26.67| 24.38| 13.50
W| 6808.25| 5486.25| 3770.00| 2749.50| 1608.75| 914.06| 690.31| 540.83| 458.48| 314.67| 287.63| 159.30

Gel Series Battery

Discharge characteristic Curve

Cycle service life in relation to the depth of discharge

Relationship between charging voltage and temperature

Constant voltage charging characteristic (0.25CA, at 25°C)

Temperature effects on float life

Self-discharge characteristic

Life characteristics of standby use

Charge characteristic for standby use

National Sales Centre – 010 202 3400
Technical – 010 202 3500
www.acdc.co.za

References