Introduction

UT383 BT with Bluetooth function is a stable, safe, reliable mini digital light meter, widely used in lightening enterprises, agriculture and animal husbandry, mining enterprises, laboratory, office, household, street lights construction and others.

This operating manual includes relevant safety information and warnings. Please read this manual carefully and observe all the cautions strictly.

warning:
Before using the product, please read the operation safety rules carefully.

Out of the Box

Open the packing box and take out the meter. Please check carefully if any items are missing or damaged.

  1.  Blister———–1
  2. Operating manual 1

Operation Safety Rules

  1. Please check the meter and the accessories before using and beware of any damage or abnormal phenomenon. If you find the case is damaged or the LCD shows nothing, or you consider that the meter could not work properly anymore, please stop using it.
  2. Observe the operating instructions while measuring.
  3. Do not open the meter at will or change internal wiring to avoid damages to the meter.
  4. When the LCD displays “ “, replace the battery timely. Remove the battery if the meter is not used for a long time.
  5. Do not store or use the meter in high temperature, high humidity, flammable, combustible, or strong electromagnetic environment.
  6. Please use soft cloth and neutral detergent to clean the case for maintenance. Do not use grinding agent and solvent to avoid case corrosion and damaging the meter.
  7. This product has passed CE certification.

Product Exterior

  1. Illumination transducer
  2. Meter case
  3. LCD display
  4. Function keys

Display Interface

Display Interface

1 Maximum measurement
2 Minimum measurement
3 Data hold
4 Low battery
5 Foot candle
6 Lux
7 Value10 or value100
8 Illumination value
9 Bluetooth communication symbol indication

Key Function and Setup

(remark: “short press” means : about 1 second continuous press; “long press” means: about 2 second continuous press)

  1.   ON/OFF /Bluetooth communication
    Short press once to start up; short press again to power off. Bluetooth communication : Under the state of boosting unit , long press to enter Bluetooth communication mode, and then long press again to quit Bluetooth communication mode.

  2. LUX/FC: lux / FOOTCANDLE
    LUX/FC unit conversion key: short press the key, the illumination units can be selected between LUX and FC in performing illumination measurement

  3. MAX/MIN
    Pressing this key can select maximum, minimum or normal value measurement; select maximum and the meter will always show the maximum reading; select minimum and the meter will always show the minimum reading.

  4. HOLD/BL
    HOLD: Short press this key to hold measurement; short press this key again to exit data hold and continue normal measurement.
    BL: Long press this key to turn on backlight; long press this key again to turn off backlight.

  5. Automatic shutdown
    No operation 5 minutes after , then shut down the unit automatically (the default is automatic shutdown mode )
    When you want to remove the automatic shutdown function, hold down the “hold”

  • ”  ” key to boot. LCD has a “APO OF” character prompt, the automatic shutdown function will be removed .

Bluetooth APP specification

  1. To connect Bluetooth , you need to install the application (iENV APP)
    on the smartphone

  2. iOS device access it in App Store , Android device access it in Play Store or Please login www.uni-trend.com to download.
    Compatibility:
    ios 8.4 or higher version
    Android 4.3 or higher version
    Bluetooth 4.0 or higher version
    Memory 1 G or more

  3. Before Bluetooth APP and product are connected , you need to open the Bluetooth at the same time, and through the APP search the Bluetooth, and select the corresponding products to be connected in iENVAPP
    • when in the working state, long press the power button to turn on or off the Bluetooth
    a. Bluetooth icon is flashing, indicating that the product is not connected with APP
    b. Bluetooth icon isn’t flashing, indicating that the product is connected with APP
    Bluetooth APP specification

Performance Testing

Technical Parameter
Function Range Resolution Accuracy Remark
**** llluminance Measurement 0-9999 Lux 1 Lux ± (4% rdg+B dgts) ****

Ambient temperature: 23°(±5°( Ambient humidity: ,s;so%RH
?10000 Lux| 10 Lux| ± (5% rdg+10 dgts)
?100000 Lux| 100 Lux| ± (5% rdg+10 dgts)
Measurement Range| 0~199900 Lux| | | Shift to automatic range

General Type

a. LCD: 4 digits LCD display. The max display is 9999
b. Overload indication: When illumination is over 199900 Lux, “OL” will be displayed
c . Battery low power display: Prompt” “.
d. Sampling rate: 0.5s
e. Sensor type: Silicon photocell
f. Impact strength: Can withstand the impact of landing from 1 meter height
g. Battery requirement: 1.5V batteries (AAA) x3
h. Power consumption: More than 12 hours with Bluetooth enabled
i. Product size: 163x55x28mm
j. Spec of thread to connect the product with three tripod: m¼”
k. Weight: 11 Bg

Environment Limitation

a. Indoor use
b. Maximum operating height: 2000m
c. Pollution level: 2
d. Working temperature and humidity:
0″C-40″C (not greater than 80%RH)
40°C-50°C (not greater than 45%RH)
e. Storage temperature and humidity: -20″C-60″C (not greater than 75%RH)

General Maintenance

Warning: please do not open the case of meter to avoid affecting device accuracy or damage to the meter.
a. Maintenance and service of the meter should be accomplished by
professional personnel or designated maintenance department.
b. Clean the case by dry cloth periodically, detergent with abrasive or solvent composition shall not be used.

Battery Installation and Replacement

a. The meter uses 3 pieces of AAA 1.5V batteries. Please see figure below for steps of battery installation and replacement.
b. Turn the panel down, push the battery cover open in the direction of the arrow, lift the cover and remove the batteries; install new batteries in accordance of polarity indications.
c. Please use batteries of same type instead of improper ones.
d. Close the cover tightly after installing new batteries.

UNI-TREND TECHNDLDGY (CHINA) CD., LTD.
No6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City,
Guangdong Province, China
Tel: (86-769) 8572 3888
http://www.uni-trend.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals