Clarke CON400 16 Inch Ventilation Fan Instruction Manual
- June 4, 2024
- Clarke
Table of Contents
16” VENTILATION FAN
MODEL NO: CON400 (110V)
PART NO: 3230483
OPERATION & MAINTENANCE
INSTRUCTIONS
ORIGINAL INSTRUCTIONS DL0722 – ISS 6
INTRODUCTION
Thank you for purchasing this CLARKE Ventilator which is designed for indoor
use in an industrial environment.
Read this manual carefully, in doing so you guarantee the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
SAFETY WARNINGS
Make sure that you read, understand and comply with the following warnings.
POSITIONING
Be aware that the suction capability is considerable. Do not position the
ventilator where it will blow dust or hazardous fumes at people.
DO NOT place the ventilator close to any wet surface. DO NOT place against any
surface such as a wall, door or furniture, etc.
DO NOT place the fan on a raised surface or anywhere it could topple over.
Only use in a level position.
Take care to ensure that the intake grille cannot be blocked by curtains or
other fabrics. Do not allow loose clothing, long hair, jewelry, etc. to be
drawn into the intake side of the fan.
DO NOT operate the ventilator in explosive atmospheres such as in the presence
of flammable liquids, gases or dust such as in a paint spray booth. Electric
motors create sparks that may ignite dust or fumes.
DO NOT cover the fan or obstruct the air inlet and outlet sections of the
ventilator.
DO NOT get the ventilator wet or use in areas of high condensation.
DO NOT allow the power cable to touch hot surfaces. ALWAYS make sure the
brakes are engaged before operating.
DO NOT operate without the safety grills secured in position.
PERSONNEL SAFETY
DO NOT use the ventilator when you are tired or under the influence of
alcohol, drugs or intoxicating medication.
DO NOT stand on the ventilator.
DO NOT use the ventilator with wet hands or when there is water on the power
cable. Young children must be kept away unless supervised.
ELECTRICAL SAFETY
Inspect the power cable/plug for damage/looseness. Do not use the fan if the
power cable is damaged. Make sure that the voltage on the product label is the
same as the voltage of the power supply. If in doubt, consult a qualified
electrician. DO NOT abuse the electrical cable. Do not use the cable for
pulling or unplugging the fan. Keep the cable away from sources of heat, oil,
sharp edges or moving parts. Damaged or tangled cables increase the risk of
electric shock. DO NOT use extension cables with this ventilator.
SERVICE & REPAIRS
Check that the fan is in good working order. Take immediate action to have it
repaired or any damaged parts replaced.
DO NOT attempt to repair the ventilator yourself. Always contact the CLARKE
service department who will use recommended parts only. Unapproved parts may
be dangerous and will invalidate your warranty.
ENVIRONMENTAL RECYCLING POLICY
By purchasing this product, the customer is taking on the obligation to deal
with its safe disposal in accordance with the Waste Electrical and Electronic
Equipment regulations (WEEE). In effect, this means that this product must not
be discarded with general household waste but according to the laws governing
Waste Electrical and Electronic Equipment (WEEE) at a recognized disposal
facility.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12
months from the date of purchase. Please keep your receipt as proof of
purchase.
This guarantee is invalid if the product is found to have been abused,
tampered with, or not used for the purpose for which it was intended. Faulty
goods must be returned to their place of purchase, no product can be returned
to us without prior permission. This guarantee does not affect your statutory
rights.
ELECTRICAL CONNECTIONS
WARNING! READ THESE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY BEFORE CONNECTING THE PRODUCT TO A POWER SUPPLY.
This product can be connected to one of the following power supplies:
- 110V Generator
- 110V Isolating Transformer
- 110V Site supply
- 230V Generator via a 110V transformer.
Connecting it to any other power source may cause damage.
This product includes a fitted industrial plug to BS-EN 60309 and a cable for
use with a 110 volt supply. On no account must a 230V, 13amp (BS1363) plug be
used.
If using a portable 110V transformer make sure it has a rated capacity
sufficient to take the load of the fan.
Should the plug need changing at any time, ensure that a plug of the identical
specification is used and proceed as follows:
-
Undo the socket screws & remove the rear section.
-
Rotate the cable clamp clear of the terminals.
-
Feed the cable through the rear gland in the plug.
-
Remove the cable sheath to the required lengths as shown in the diagram.
-
Terminate the correct wires in the correct terminal blocks as shown.
-
Remove the cable clamp screws. Clip the cable clamp back into position and place the clamp around the outer sheath of the cable. Replace the screws and tighten until the cable is securely held.
-
Replace the rear cover and tighten the cover screws.
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.
BEFORE USE
Before assembly, check for damage or shortages. Any damage or shortage should be reported to the CLARKE dealer where the fan was purchased. Your ventilation fan should be supplied with the following parts:
- 4 x castor (2 with brakes)
- 16 bolts, 16 nuts, 16 spring washers, and 32 flat washers.
Bolt the castor assemblies to the frame as shown using the fastenings
supplied. Install the castors with brakes at one end of the frame.
This ventilator will be used with CLARKE 16” diameter retractable ducting is
available in 5 metre lengths sold separately as follows: Yellow (3230484) or
Orange (3230241)
- Before use, attach the ducting to the discharge end of the ventilator as shown, secured with the tie cord provided.
- Place the ventilator in a level position on a flat surface and at a safe distance from flammable materials.
- Set the angle of tilt as required using the hand knob shown.
- Connect the ventilator to a suitable power outlet.
- Always apply the brakes before operating the ventilator.
CARE & MAINTENANCE
WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE PERFORMING ANY CLEANING OR MAINTENANCE TASKS. REPAIRS SHOULD BE CARRIED OUT BY THE CLARKE SERVICE DEPARTMENT.
Clean the ventilator with a soft damp cloth, Do not use solvents or abrasives.
If used in spaces with high dust content, clean the guards and fan blades by
vacuuming or wiping.
Remove the end guard to gain access to the blades by removing the four
securing screws.
REPLACE GUARD BEFORE RE-CONNECTING TO POWER SUPPLY.
No other maintenance is required, should you discover any problem with the
ventilator return it to the CLARKE service department for repair. Should the
fan fail to operate, check the power supply and that the circuit breaker has
not tripped? Abnormal noise while the fan is running may occur if the fan is
not standing on a level surface.
Model | CON400 |
---|---|
Product dimensions | 575 x 435 x 770 mm |
Fan diameter | 385mm |
Product Weight | 38 kg |
Tilt range | 360° |
Operating temperature | 10 – 40°C |
Power supply | 110V/50Hz |
Duty Cycle Classification: | Si (continuous) |
Electrical Insulation Class | I |
Ingress Protection Rating | IP 54 |
Fan rpm @ optimum energy efficiency | 2800 rpm |
Flow rate at full speed | 120 m3/min (7200 m3/h) |
Rated air flow @ overall efficiency point | 63.28 m3/s (3796.7 m3/h) |
Rated air flow @ optimum energy efficiency | 63.28 m3/s (3796.7 m3/h) |
Rated pressure @ optimum energy efficiency | 436.41 Pa |
Total pressure | 700 Pa |
Static pressure@ overall efficiency point | 436.41 Pa |
Rated motor input power | 1200 W |
Overall efficiency | 60.% |
Measurement category | C |
Efficiency category | Static |
Efficiency grade (at optimum energy point) | 40 |
Specific Ratio (EU no 327/2011) | N/A |
Sound Guaranteed Power level: (dB LWA) | 79dB |
DECLARATION OF CONFORMITY
PARTS & SERVICE: 0208 988 7400
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
Clarke® INTERNATIONAL Hemnall Street, Epping, Essex CM16 4LG
www.clarkeinternational.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>