YAMAT YW09G8-I Split Air Conditioner Owner’s Manual
- June 10, 2024
- YAMAT
Table of Contents
YW09G8-I Split Air Conditioner
Product Information
This is a split air conditioner with the following product models: YW09G8/I, YW12G8/I, YW18G8/I, YW24G8/I.
Contents
- Safety precautions
- Installation notice
- Installation of indoor unit
- Clean and maintenance
- Checked items before maintenance
- Parts name
- Operation and introduction of remote controller
- Test and operation
- Configuration of connection pipe
- Specialist’s Manual
The product comes with an owner’s manual that must be carefully read before operation. The actual product may differ from the graphics shown, so it is important to refer to the actual product.
Explanation of Symbols
- WARNING: This symbol indicates the possibility of death or serious injury.
- CAUTION NOTICE: This symbol indicates the possibility of injury or damage to property.
- Exception Clauses: Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons:
1. Damage the product due to improper use or misuse of the product;
2. Alter, change, maintain or use the product with other equipment without abiding by the instruction manual of manufacturer;
3. After verification, the defect of product is directly caused by corrosive gas;
4. After verification, the defects are due to improper operation during transportation of product;
5. Operate, repair, maintain the unit without abiding by instruction manual or related regulations;
6. After verification, the problem or dispute is caused by the quality specification or performance of parts and components that produced by other manufacturers;
7. The damage is caused by natural calamities, bad using environment or force majeure.
- The refrigerant: The appliance is filled with flammable gas R32. Before using, installing, or repairing the appliance, read the respective manuals first. To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The used refrigerant is the fluoride R32, which is specially cleaned. The refrigerant is flammable and inodorous. Furthermore, it can lead to an explosion under certain conditions. But the flammability of the refrigerant is very low. It can be ignited only by fire. Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The influence upon the greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efficiency. The units therefore need less filling.
Product Usage Instructions
Before using, installing, or repairing the appliance, make sure to read the
respective manuals first.
Installation
Follow the installation notice provided in the manual carefully. Install the indoor unit as per the instructions provided in section “Installation of indoor unit”.
Operation
After installation, refer to the section “Test and operation” For
instructions on operating the unit. Make sure to follow the instructions
provided in the “Operation and introduction of remote controller” section for
using the remote controller.
Clean and Maintenance
Refer to the “Clean and maintenance” section for information on cleaning and maintaining the appliance. Before maintenance, make sure to check the items provided in the “Checked items before maintenance” section.
Configuration of Connection Pipe
Refer to the “Configuration of connection pipe” section for information on
configuring the connection pipe.
Specialist’s Manual
If you are a specialist, refer to the “Specialist’s Manual” section for
additional information.
Thank you for choosing our product.Please read this Owner’s Manual carefully before operation and retain it for future reference.
NOTE: Actual product may be different from graphics, please refer to actual products.
YW09G8/I YW12G8/I YW18G8/I YW24G8/I
Explanation of Symbols
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION NOTICE
This symbol indicates the possibility of injury or damage to property.
Indicates important but not hazard-related information, used to indicate risk
of property damage.
Exception Clauses
Manufacturer will bear no responsibilities when personal injury or property
loss is caused by the following reasons.
1.Damage the product due to improper use or misuse of the product; 2.Alter,
change, maintain or use the product with other equipment without abiding
by the instruction manual of manufacturer; 3.After verification, the defect of
product is directly caused by corrosive gas; 4.After verification, the defects
are due to improper operation during transportation
of product; 5.Operate, repair, maintain the unit without abiding by
instruction manual or related
regulations; 6.After verification, the problem or dispute is caused by the
quality specification or
performance of parts and components that produced by other manufacturers;
7.The damage is caused by natural calamities, bad using environment or force
majeure.
If it needs to install, move or maintain the air conditioner, please contact dealer or local service center to conduct it at first. Air conditioner must be installed, moved or maintained by appointed unit. Otherwise, it may cause serious damage or personal injury or death. When refrigerant leaks or requires discharge during installation, maintenance, or disassembly, it should be handled by certified professionals or otherwise in compliance with local laws and regulations. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
The refrigerant
Appliance filled with flammable gas R32.
Before use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
To realize the function of the air conditioner unit, a special refrigerant
circulates in the system. The used refrigerant is the fluoride R32, which is
specially cleaned. The refrigerant is flammable and inodorous. Furthermore, it
can lead to explosion under certain conditions. But the flammability of the
refrigerant is very low. It can be ignited only by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no
harm to the ozonosphere. The influence upon the greenhouse effect is also
lower. R32 has got very good thermodynamic features which lead to a really
high energy efficiency. The units there fore need a less filling.
WARNING
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacture. Should repair be necessary, contact your
nea rest authorized Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance shall be stored in a room without
continuously operating ignition sources. (for example: open flames, an
operating gas appliance or an operating electric heater.) Do not pierce or
burn. Appliance shall be installed, operated and stored in a room with a floor
area larger than X m2. (Please refer to table “a” in section of ” Safety
operation of flammable refrigerant ” for space X.) Appliance filled with
flammable gas R32 . For repairs, strictly follow manufacturer’s instructions
only. Be aware that refrigerants may not contain an odour. Read specialist’s
manual.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety. Children should
be supervised to ensure that they do not play with the appliance. Hereby, our
company declare that this Air Conditioner is in compliance with the essential
requirement and other relevant provisions of RE Directive 2014/53/EU. A copy
of the full DoC is attached. Wireless frequency range: 2412MHz – 2472MHz
Maximum Transmit Power: 18dBm
R32: 675 This marking indicates that this product should not be disposed with
other house hold wastes. To prevent possible harm to the environment or human
health from uncontrolled waste throughout the EU. To prevent possible harm to
the environment or human health. From uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased. They can take this product for
environmental safe recycling. If it needs to install, move or maintain the air
conditioner, please contact dealer or local service center to conduct it at
first. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
Safety operation of flammable refrigerant
Qualification requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear the
valid certification awarded by the authoritative organization and the
qualification for dealing with the refrigeration system recognized by this
industry. If it needs other technician to maintain and repair the appliance,
they should be supervised by the person who bears the qualification for using
the flammable refrigerant. It can only be repaired by the method suggested by
the equipment’s manufacturer.
Safety operation of flammable refrigerant
Installation notes
The air conditioner must be installed in a room that is larger than the
minimum room area. The minimum room area is shown on the nameplate or
following table a. It is not allowed to drill hole or burn the connection
pipe.
Leak test is a must after installation.
table a – Minimum room area ( m)
Charge amount (kg)
1.2
floor
window wall
ceiling
location mounted mounted mounted
1.3
14.5
5.2
1.6
1.1
1.4
16.8
6.1
1.9
1.3
1.5
19.3
7
2.1
1.4
1.6
22
7.9
2.4
1.6
1.7
24.8
8.9
2.8
1.8
1.8
27.8
10
3.1
2.1
1.9
31
11.2
3.4
2.3
2
34.3 12.4
3.8
2.6
2.1
37.8 13.6
4.2
2.8
2.2
41.5
15
4.6
3.1
2.3
45.4 16.3
5
3.4
2.4
49.4 17.8
5.5
3.7
2.5
53.6 19.3
6
4
Maintenance notes
Check whether the maintenance area or the room area meet the requirement of
the nameplate. – It’s only allowed to be operated in the rooms
that meet the requirement of the nameplate.
Check whether the maintenance area is wellventilated. – The continuous
ventilation status should be
kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance
area. – The naked flame is prohibited in the mainte-
nance area; and the “no smoking” warning board should be hanged.
Check whether the appliance mark is in good condition. – Replace the vague or
damaged warning mark.
Welding
If you should cut or weld the refrigerant system pipes in the process of
maintaining, please follow the steps as below: a. Shut down the unit and cut
power supply b. Eliminate the refrigerant c. Vacuuming d. Clean it with N2 gas
e. Cutting or welding f. Carry back to the service spot for welding
The refrigerant should be recycled into the specialized storage tank. Make
sure that there isn’t any naked flame near the outlet of the vacuum pump and
it’s wellventilated.
Filling the refrigerant
Use the refrigerant filling appliances specialized for R32. Make sure that
different kinds of refrigerant won’t contaminate with each other. The
refrigerant tank should be kept upright at the time of filling refrigerant.
Stick the label on the system after filling is finished (or haven’t finished).
Don’t overfilling. After filling is finished, please do the leakage detection
before test running; another time of leak detection should be done when it’s
removed.
Safety instructions for transportation and storage
Please use the flammable gas detector to check before unload and open the
container. No fire source and smoking. According to the local rules and laws.
Safety precautions
WARNING
Installation
Installation or maintenance must be performed by qualified professionals. The
appliance shall be installed in accordance with national wiring regulations.
According to the local safety regulations, use qualified power supply circuit
and circuit breaker. All wires of indoor unit and outdoor unit should be
connected by a professional. Be sure to cut off the power supply before
proceeding any work related to electricity and safety. Make sure the power
supply matches with the requirement of air conditioner. Unstable power supply
or incorrect wiring may result in electric shock, fire hazard or malfunction.
Please install proper power supply cables before using the air conditioner.
The grounding resistance should comply with national electric safety
regulations. Air Conditioner should be properly grounded. Incorrect grounding
may cause electric shock. Do not put through the power before finishing
installation. Do install the circuit breaker. If not, it may cause
malfunction.
An all-pole disconnection switch having a contact separation of at least 3mm
in all poles should be connected in fixed wiring. Circuit breaker should be
included magnet buckle and heating buckle function. It can protect the
overload and circuit-short.
1
Safety precautions
CAUTION
Installation
Instructions for installation and use of this product are provided by the
manufacturer. Select a location which is out of reach for children and far
away from animals or plants. If it is unavoidable, please add the fence for
safety purpose. The indoor unit should be installed close to the wall. Don’t
use unqualified power cord. If the length of power connection wire is
insufficient, please contact the supplier for a new one. The appliance must be
positioned so that the plug is accessible. For the air conditioner with plug,
the plug should be reachable after finishing installation.
For the air conditioner without plug, a circuit breaker must be installed in the line. The yellow-green wire in air conditioner is grounding wire, which can’t be used for other purposes. The air conditioner is the first class electric appliance. It must be properly grounder with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
2
Safety precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision. If the supply cord is
damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard. Do not connect air
condi-
tioner to multi-purpose socket. Otherwise, it may cause fire hazard. Do disconnect power supply when cleaning air conditioner. Otherwise, it may cause electric shock. Do not wash the air conditioner with water to avoid electric shock. Do not spray water on indoor unit. It may cause electric shock or malfunction. Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to repair air conditioner. After removing the filter, do not touch fins to avoid injury. Do not extend fingers or objects into air inlet or air outlet. It may cause personal injury or damage.
3
Safety precautions
CAUTION
Operation and Maintenance
Do not spill water on the remote controller, otherwise the remote controller
may be broken. Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard. Do not block air outlet or air inlet. It may cause
malfunction. Do not step on top panel of outdoor unit, or put heavy objects.
It may cause damage or personal injury. When below phenomenon occurs, please
turn off air conditioner and disconnect power immediately, and then contact
the dealer or qualified professionals for service.
Power cord is overheating or damaged. There’s abnormal sound during operation.
Circuit breaker trips off
frequently. Air conditioner gives off burning smell. Indoor unit is leaking.
4
Installation notice
SpaAcet lteoatshte1c5ecimling
Space to the wall At least 15cm
Space to the wall At least 15cm
Space to the obstruction At least 300cm Space to the floor At least 250cm
Safety precautions for installing and relocating the unit
To ensure safety, please be mindful of the following precautions.
WARNING When installing or relocating the unit, be s-
ure to keep the refrigerantcircuit free from air or substances other than the
specified refrigerant. Any presence of air or other foreign substance in the
refrigerant circuit will cause system pressure rise or compressor rupture,
resulting in injury. When installing or moving this unit, do not charge the
refrigerant which is not comply with that on the nameplate or unqualified
refrigerant. Otherwise, it may cause abnormal operation, wrong action,
mechanical malfunction or even serious safety accident. When refrigerant needs
to be recovered during relocating or repairing the unit, be
WARNING
sure that the unit is running in cooling mode. Then, fully close the valve at
high pressure side (liquid valve). About 30-40 seconds later, fully close the
valve at low pressure side (gas valve), immediately stop the unit and
disconnect power. Please note that the time for refrigerant recovery should
not exceed 1 minute.
If refrigerant recovery takes too much time, air may be sucked in and cause
pressure rise or compressor rupture, resulting in injury. During refrigerant
recovery, make sure that liquid valve and gas valve are fully closed and power
is disconnected before detaching the connection pipe.
If compressor starts running when stop valve is open and connection pipe is
not yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury.
When installing the unit, make sure that connection pipe is securely connected
before the compressor starts running.
If compressor starts running when stop valve is open and connection pipe is
not yet connected, air will be sucked in and cause pressure rise or compressor
rupture, resulting in injury. Prohibit installing the unit at the place where
there may be leaked corrosive gas or flammable gas.
If there is leaked gas around the unit, it may cause explosion and other
accidents. Do not use extension cords for electrical connections. If the
electric wire is not long enough, please contact a local service center
authorized and ask for a proper electric wire. Poor connections may lead to
electric shock or fire. Use the specified types of wires for electrical
connections between the indoor and outdoor units. Firmly clamp the wires so
that their terminals receive no external stresses.
Electric wires with insufficient capacity, wrong wire connections and insecure
wire terminals may cause electric shock or fire.
Tools for installation
Level meter 7 Open-end 12 Universal
2 Screw driver 3 Impact drill 4 Drill head
wrench
8 Pipe cutter
9
Leakage detector
meter 13 Inner hexagon
spanner
14 Measuring
5 Pipe expander 10 Vacuum pump tape
6 Torque wrench 11 Pressure meter
NOTICE Please contact the local agent for installation. Don’t use unqualified power cold.
5
Selection of installation location
Basic requirement Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the local dealer: 1.The
place with strong heat sources, vapors,
flammable or explosive gas, or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical
equipment).
3.The place near coast area. 4.The place with oil or fumes in the air. 5.The
place with sulfureted gas. 6.Other places with special circumstances. 7.The
appliance shall not be installed in the
laundry. 8.It’s not allowed to be installed on the unstable
or motive base structure (such as truck) or in the corrosive environment (such
as chemical factory).
Indoor unit 1.There should be no obstruction near air inlet
and air outlet. 2.Select a location where the condensation water
can be dispersed easily and won’t affect other people.
3.Select a location which is convenient to connect the outdoor unit and near
the power socket.
4.Select a location which is out of reach for children. 5.The location should
be able to withstand the
weight of indoor unit and won’t increase noise and vibration. 6.The appliance
must be installed 2.5m above floor. 7.Don’t install the indoor unit right
above the electric appliance. 8.Please try your best to keep way from
fluorescent lamp.
Safety precaution
1.Must follow the electric safety regulations when installing the unit.
2.According to the local safety regulations, use qualified power supply
circuit and air switch.
3.Make sure the power supply matches with the
requirement of air conditioner. Unstable power
supply or incorrect wiring or malfunction. Pl-
ease install proper power supply cables before
using the air conditioner.
4.Properly connect the live wire, neutral wire and
grounding wire of power socket.
5.Be sure to cut off the power supply before pr-
oceeding any work related to electricity and safety.
6.Do not put through the power before finishing
installation.
Requirements for electric connection
7.If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard .
8.The temperature of refrigerant circuit will be high, please keep the
interconnection cable away from the copper tube.
9.The appliance shall be installed in accordance with national wiring
regulations.
Grounding requirement 1.The air conditioner is the first class electric
appliance. It must be properly grounding with specialized grounding device by
a professional. Please make sure it is always grounded effectively, otherwise
it may cause electric shock. 2.The yellow-green wire in air conditioner is
grounding wire, which can ‘t be used for other purposes.
3.The grounding resistance should comply with national electric safety
regulations.
4.The appliance must be positioned so tha t the plug is accessible.
5.An all-pole disconnection switch having a contact separation of at least 3mm
in all poles should be connected in fixed wiring.
6
Installation of indoor unit
Step 1: Choose installation location
Recommend the installation location to the client and then confirm it with the
client.
NOTE Pay attention to dust prevention
and take relevant safety measures when opening the hole.
Indoor
5-10
outdoor 55 70
Step 2: Install wall-mounting frame
1.Hang the wall-mounting frame on the wall; adjust it in horizontal position
with the level meter and then point out the screw fixing holes on the wall.
Step 4: Outlet pipe
1. The pipe can be led out in the direction of right, rear right, left or
rear left.
2. Drill the screw fixing holes on the wall with impact drill(the specification of drill head should be the same as the plastic expansion particle) and then fill the plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws and then check if the frame is firmly installed by pulling the frame. If the plastic expansion particle is loose, please drill another fixing hole nearby.
Wall
Mark in the middle of it
Space to the wall above 150mm
Left
(Rear piping hole)
Level meter
(For some models)
Wall Space to the wall above 150mm Right
(Rear piping hole)
Step 3: Open piping hole
1. Choose the position of piping hole according to the direction of outlet
pipe. The position of piping hole should be a little lower than the
wall-mounted frame, shown as below.
right
left rear right
rear left
2. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case.
left
right
cut off the hole
Step 5: Connect the pipe of indoor unit
1. Aim the pipe joint at the corresponding bellmouth.
2. Pretighten the union nut with hand.
pipe joint union nut pipe
NOTE
The wall panel is for illustrative purposes only, please refer to the actual
installation.
Please refer to the actual circumstances for the number of screws and the
position of screws.
3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union
2. When installation is finished, pull the mounting
nut with torque wrench.
plate with hand to confirm whether it is fixed tightly. The force distribution
for all screws should be uniform.
3. Open a piping hole with the diameter of 55
open-end wrench
union nut
or 70 on the selected outlet pipe position. In order to drain smoothly, slan t the piping
torque wrench
pipe
hole on the wall slightly downward to the outdoor side with the gradient of 5-10°.
indoor pipe
7
Hex nut diameter Tightening torque (N.m)
1/4”
15~20
3/8”
30~40
1/2”
45~55
5/8”
60~65
3/4”
70~75
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape.
insulating pipe
Step 6: Install drain hose
1. Connect the drain hose to the outlet pipe of indoor unit.
drain hose
insulating pipe
NOTE Add insulating pipe in the indoor drain hose in order
to prevent condensation. The plastic expansion particles are not provided.
Step 7: Connect wire of indoor unit
NOTICE All wires of indoor unit and outdoor unit should be
connected by a professional. If the length of power connection wire is
insufficient,
please contact the supplier for a new one. Avoid extending the wire by
yourself.
For the air conditioner with plug, the plug should be reachable after
finishing installation.
For the air conditioner without plug, an air switch must be installed in the
line. The air switch should be all-pole parting and the contact parting
distance should be more than 3mm.
1. Open the panel, remove the screw on the wiring cover and then take down the cover.
panel
screw
outlet pipe
drain hose
2. Bind the joint with tape
drain hose outlet pipe
wiring cover 2. Make the power connection wire go through the
cable cross hole at the back of indoor unit and then pull it out from the
front side.
hole
tape
power connection wire
8
3. Remove the wire clip; connect the power connection wire to the wiring terminal according to the color; tighten the screw and then fix the power connection wire with wire clip.
connection pipe
drain hose
band
N(1) 2 3
blue black brown
yellowgreen
Outdoor unit connection
NOTICE The wiring board is for reference only, please refer
to the actual one.
4. Put wiring cover back and then tighten the screw. 5. Close the panel.
Step 8: Bind up pipe
1. Bind up the connection pipe, power cord and drain hose with the band.
indoor unit
indoor and outdoor power cord
gas pipe
indoor power cord
3. Bind them evenly. 4. The liquid pipe and gas pipe should be bo-
und separately at the end.
NOTICE The power cord and control wire can’t be crossed or
winding. The drain hose should be bound at the bottom.
Step 9: Hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the
wall hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe. 5. Check if the indoor unit is installed firmly and
closed to the wall.
indoor wall pipe
outdoor sealing gum
upper hook
band
liquid pipe drain hose
2. Reserve a certain length of drain hose and power cord for installation when binding them. When binding to a certain degree, separate the indoor power and then separate the drain hose.
lower hook of wall-mounting frame
NOTICE Do not bend the drain hose too excessively in order
to prevent blocking.
9
Clean and maintenance
WARNING
Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
Do not wash the air conditioner with water to avoid electric shock.
Do not use volatile liquid to clean the air conditioner.
Do not use liquid or corrosive detergent to clean the appliance and do not
splash water or other liquid onto it , otherwise, it may damage the plastic
components , even cause electric shock.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry
cloth or wet cloth to wipe it. NOTICE Do not remove the panel when cleaning
it.
Clean filter
1. Open panel Pull out the panel to a certain angle as shown in the fig.
2. Remove filter Remove the filter as indicated in the fig.
WARNING The filter should be cleaned every three months.
If there is much dust in the operation environment, clean frequency can be
increased. After removing the filter, do not touch fins to avoid injury. Do
not use fire or hair dryer to dry the filter to avoid deformation or fire
hazard.
NOTICE: Checking before use-season 1.Check whether air inlets and air outlets
are bl-
ocked. 2.Check whether air switch, plug and socket are
in good condition. 3.Check whether filter is clean. 4.Check whether mounting
bracket for outdoor
unit is damaged or corroded . If yes, please contact dealer. 5.Check whether
drainage pipe is damaged.
NOTICE: Checking after use-season 1.Disconnect power supply. 2.Clean filter
and indoor unit’s panel. 3.Check whether mounting bracket for outdo or
unit is damaged or corroded. If yes, please contact dealer.
Notice for recovery
1.Many packing materials are recyclable materials. Please dispose them in
appropriate recycling unit.
2.If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
3. Clean filter Use dust catcher or water to clean the filter.
When the filter is very dirty, use the water (below 45¥) to clean it , and
then put it in a shady and cool place to dry.
4. Install filter Install the filter and then close the panel cover tightly.
Error Code
When air conditioner status is abnor mal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to below list for identification of error code.
Error code
Troubleshooting
E1,E5, E6, E8 H3, H6, U8
It can be eliminated after restarting the unit. If not, please contact qualified professionals for service.
C5, F0, F1, F2
Please contact qualified professionals for service.
NOTE If there’re other error codes, please contact qu-
alified professionals for service.
10
Checked items before maintenance
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction
still can’t be eliminated, please contact local dealer or qualified
professionals.
Phenomenon
Check items
Solution
Whether it’s interfered Pull out the plug.
severely (such as sta- Reinsert the plug after
tic electricity, stable about 3min, and then
voltage?)
turn on the unit again.
Whether remote controller is within the signal receiving range?
Signal receiving range is 8m.
Whether there are Indoor unit obstacles?
Remove obstacles.
can’t receive
Select proper angle
remote co- Whether remote co- and point the remote
ntroller’s si- ntroller is pointing at controller at the rece-
gnal or remote the receiving window? iving window on indoor
controller has
unit.
no action.
Is sensitivity of rem- Check the batteries. ote controller low; If the power of batteries
fuzzy display or no is too low, please rep-
display?
lace them.
No display when operating remote controller?
Check whether remote controller appears to be damaged. If yes, replace it.
Fluorescent lamp in room?
Take the remote controller close to indoor unit. Turn off the fluorescent lamp and then try it again.
No air emitted from indoor unit
Air inlet or air outlet
of indoor unit is
Eliminate obstacles.
blocked?
Under heating mode, After reaching to set
indoor temperature is temperature, indoor
reached to set temp- unit will stop blowing
erature?
out air.
Heating mode is turned on just now?
In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
Power failure?
Wait until power recovery.
Is plug loose?
Reinsert the plug.
Air switch trips off Ask professional to
Air
or fuse is burnt out? replace air switch or fuse.
conditioner can’t operate
Wiring tion?
has
malfunc-
Ask professional to replace it.
Unit has restarted Wait for 3min, and
immediately after then turn on the unit
stopping operation? again.
Whether the function setting for remote Reset the function. controller is correct?
Mist is emitted from indoor unit’s
Because indoor air
Indoor temperature and humidity is high?
is cooled rapidly. After a while, indoor temperature and hu-
air outlet
midity will be decrease
and mist will disappear.
Phenomenon
Check items
Solution
Odours are emitted
Whether there’s odour source, such as furniture and cigarette, etc.
Eliminate the odour source. Clean the filter.
Set tempe- Your required temp-
rature can’t
erature exceeds the set temperature
Set temperature range:16°C~30°C.
be adjusted range?
Cooling (heating) effect is not good.
Voltage is too low?
Filter is dirty? Set temperature is in proper range?
Wait until the voltage resumes normal. Clean the filter. Adjust temperature to proper range.
Door and window are open?
Close door and window.
Air conditi- Whether there’s inte- Disconnect power,
oner operates
rference, such as thunder, wireless
put back power, and then turn on the unit
abnormally devices, etc.
again.
“Water flowing” noise
Cracking noise
Air conditioner is turned on or turned off just now?
The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon.
Air conditioner is turned on or turned off just now?
This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature.
WARNING
When below phenomenon occurs,please turn off air conditioner and disconnect
power immediately, and then contact the dealer or qualified professionals for
service.
Power cord is overheating or damaged. There’s abnormal sound during operation.
Air switch trips off frequently. Air conditioner gives off burning smell.
Indoor unit is leaking.
Do not repair or refit the air conditioner by yourself. If the air conditioner
operates under abnormal conditions, it may cause malfunction, electric shock
or fire hazard.
11
Parts name
Indoor Unit
air inlet panel filter
aux. button
air outlet horizontal louver
If remote controller is lost or damaged, please use aux. button to turn on or
turn off the air conditioner. The operation in details is as below: As shown
in the figure, open panel and press aux. button to turn off the air
conditioner. When the air conditioner is turned on, it will operate under auto
mode.
Display
Heat mode Cool mode
Dry mode
Temp. indicator Power indicator
Rred indicator
R (only for heat model)
W Wwhite indicator G Ggreen indicator O Oorange indicator
NOTE
This is the general introduction and the color of indicator is only for
reference. Please refer to the actual display.
Display content may be different from the actual. Please refer to the actual
display.
12
Operation and introduction of remote controller
Buttons on remote controller
Introduction for icons on display screen
Operation mode
Temp. display type
I feel Set fan speed
Turbo mode Send signal Auto mode Cool mode Dry mode Fan mode Heat mode Sleep
mode 8 heating function Health mode Scavenging function
Quiet X-FAN function
Set temp.
Indoor ambient temp. Outdoor ambient temp.
Clock Set temperature WiFi function
Set time TIMER ON / TIMER OFF
Light Left & right swing Up & down swing
Child lock
13
Introduction for buttons on remote controller
NOTE This is a general use remote controller. It could be
used for the air conditioner with multifunction. For the functions which the
model doesn’t have, if press the corresponding button on the remote
controller, the unit will keep the original running status. After putting
through the power, the air conditioner will give out a sound. Power indicator
” ” is ON. After that, you can operate the air conditioner by using remote
controller. Under on status, pressing the button on the remote controller, the
signal icon ” ” on the display of remote controller will blink once and the
air conditioner will give out a “di” sound, which means the signal has been
sent to the air conditioner. As for the models with functions of WiFi or wired
controller, the indoor unit must has been controlled by standard remote
controller under auto mode first, and then the function of adjustable
temperature under auto mode can be realized by APP or the wired controller.
This remote controller can adjust the temperature under auto mode. When
matching with the unit which is without the function of adjustable temperature
under auto mode, the set temperature under auto mode may be invalid, or the
displayed set temperature on the unit is not same as that on the remote
controller under auto mode.
button
Press this button to turn on the unit. Press this button again to turn off the
unit.
button to adjust fan blowing angle. When selecting dry mode, the air
conditioner
operates at low speed under dry mode. Under dry mode, fan speed can’t be
adjusted. Press ” ” / ” ” button to adjust fan blowing angle. When selecting
fan mode, the air conditioner will only blow fan, no cooling and no heating.
Press “FAN” button to adjust fan speed. Press ” ” / ” ” button to adjust fan
blowing angle. When selecting heat mode, the air conditioner operates under
heat mode. Press “” or “” button to adjust set temperature. Press “FAN” button
to adjust fan speed. Press ” ” / ” ” button to adjust fan blowing angle.
NOTE
For preventing cold air, after starting up heat mode, indoor unit will delay
1~5 minutes to blow air (Actual delay time depends on indoor ambient
temperature).
Set temperature range from remote controller: 16~30°C(61-86°F).
Fan speed: auto, low speed, low-medium speed,medium speed, medium-high
speed,high speed.
Under auto mode, temperature can be displayed; Under auto mode, set
temperature can be adjusted.
button
This button is used for setting Fan Speed in the
sequence that goes from AUTO, , ,
,
to
, then back to Auto.
Auto
button
Press this button to select your required operation mode.
AUTO COOL DRY FAN
HEAT
When selecting auto mode, air conditioner will operate automatically according
to the sensed temperature. Press “FAN” button can adjust fan speed. Press ” ”
/ ” ” button can adjust fan blowing angle.
After selecting cool mode, air conditioner will operate under cool mode. Press
“” or “” button to adjust set temperature. Press “FAN” button to adjust fan
speed. Press ” ” / ” ”
Low speed
Low-Medium speed
Medium speed
Medium-High speed
High speed
NOTE
It’s low fan speed under dry mode. X-FAN function Hold fan speed button for 2s
in cool
or dry mode, the icon ” ” is displayed and the indoor fan will continue
operation for a few minutes in order to dry the indoor unit even though you
have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is
not available in auto, fan or heat mode. This function indicates that moisture
on evaporator of indoor unit will be blowed after the unit is stopped to avoid
mould.
14
Having set X-FAN function on: After turning off the unit by pressing ” ”
button indoor fan will continue running for a few minutes. at low speed. In
this period, Hold fan speed button for 2s to stop indoor fan directly.
Having set X-FAN function off: After turning off the unit by pressing ” ”
button, the complete unit will be off directly.
2s later, status will switch to off status directly; if press this button
again within 2s, the change of swing status will also depend on the
circulation sequence stated above. The function is only available for some
models.
button
Press this button can select up & down swing angle. Fan blow angle can be
selected circularly as below:
button
Under cool or heat mode, press this button to turn to quick cool or quick heat
mode. ” ” icon is displayed on remote controller. Press this button again to
exit turbo function and ” ” icon will disappear. If start this function, the
unit will run at super-high fan speed to cool or heat quickly so that the
ambient temperature approaches the preset temperature as soon as possible.
button
Press “” or “” button once increase or decrease set temperature 1°C(°F).
Holding “” or “” button, 2s later, set temperature on remote controller will
change quickly. On releasing button after setting is finished, temperature
indicator on indoor unit will change accordingly. When setting TIMER ON, TIMER
OFF or CLOCK, press “” or “” button to adjust time. (Refer to CLOCK, TIMER ON,
TIMER OFF buttons).
button
Press this button can select left & right swing angle. Fan blow angle can be
selected circularly as below:
no display (stops at current position)
NOTE
Press this button continuously more than 2s, the main
unit will swing back and forth from left to right, and
then loosen the button, the unit will stop swinging and
present position of guide louver will be kept immedi-
ately. Under left and right swing mode, when the status is
switched from off to
, if press this button again
no display (horizontal louvers stops at current position)
When selecting ” “, air conditioner is blowing fan automatically. Horizontal
louver will automatically swing up & down at maximum angle.
When selecting ” a a a a “, air conditioner is blowing fan at fixed position.
Horizontal louver will stop at the fixed position.
When selecting ” a a “, air conditioner is blowing fan at fixed angle.
Horizontal louver will send air at the fixed angle.
Hold ” “button above 2s to set your required swing angle. When reaching your
required angle, release the button.
NOTE
” a a ” may not be available. When air conditioner receives this signal, the
air conditioner will blow fan automatically.
Press this button continuously for more than 2s, the main unit will swing back
and forth from up to down, and then loosen the button, the unit present
position of guide louver will be kept immediately.
Under up and down swing mode, when the status is switched from off to , if
press this button again 2s later, status will switch to off status directly;
if press this button again within 2s, the change of swing status will also
depend on the circulation sequence stated above.
button
Press this button, can select Sleep 1 ( 1 ), Sleep 2 ( 2 ), Sleep 3 ( 3 ) and
cancel the Sleep, circulate between these, after electrified, Sleep Cancel is
defaulted. Sleep 1 is Sleep mode 1, in Cool modes; sleep status after run for
one hour, the main unit setting temperature will increase 1 , two hours,
setting
15
temperature increased 2 , then the unit will run at this setting temperature;
In Heat mode: sleep status after run for one hour, the setting temperature
will decrease 1 , two hours, setting
temperature will decrease 2 , then the unit will run at this setting
temperature. Sleep 2 is sleep mode 2, that is air conditioner will run
according to the presetting a group of sleep temperature curve.
Sleep 3-the sleep curve setting under Sleep mode by DIY; (1) Under Sleep 3
mode, press “Turbo” button for a long time, remote controller enters into user
individuation sleep setting status, at this time, the time of remote
controller will display ” 1hour “, the setting temperature “88” will display
the corresponding temperature of last setting sleep curve and blink (The first
entering will display according to the initial curve setting value of original
factory); (2) Adjust “” and ” ” button, could change the corresponding setting
temperature, after adjusted, press “Turbo” button for confirmation; (3) At
this time, 1hour will be automatically increased at the timer position on the
remote control, (that are “2hours” or “3hours” or “8 hours ” ), the place of
setting temperature ” 88 ” will display the corresponding temperature of last
setting sleep curve and blink; (4) Repeat the above step (2)~(3) operation,
until 8 hours temperature setting finished, sleep,curve setting finished, at
this time, the remote controller will resume the original timer display;
temperature display will resume to original setting temperature.
Sleep 3-the sleep curve setting under Sleep mode by DIY could be inquired: The
user could accord to sleep curve setting method to inquire the presetting
sleep curve, enter into user individuation sleep setting status, but do not
change the temperature, press “Turbo” button directly for confirmation. Note:
In the above presetting or enquiry procedure, if continuously within 10s,
there is no button pressed, the sleep curve setting within 10s, there is no
button pressed, the sleep curve setting status will be automatically quit and
resume to display the original displaying. In the presetting or enquiry
procedure, press “ON/OFF” button, ” Mode” button, ” Sleep ” button, the sleep
curve setting or enquiry status will quit similarly.
button
Press this button to start I FEEL function and ” ” will be displayed on the
remote controller. After this function is set, the remote controller will send
the detected ambient temperature to the controller and the unit will
automatically adjust the indoor temperature according to the detected
temperature. Press this button again to close I FEEL function and ” ” will
disappear. Please put the remote controller near user when this function is
set. Do not put the remote controller near the object of high temperature or
low temperature in order to avoid detecting inaccurate ambient temperature.
When I FEEL function is turned on, the remote controller should be put within
the area where indoor unit can receive the signal sent by the remote
controller.
/
button
TIMER ON button “TIMER ON” button can set the time for timer on. After
pressing this button, ” ” icon disappears and the word “ON” on remote
controller blinks. Press “” or “” button to adjust TIMER ON setting. After
each pressing “” or “” button. TIMER ON setting will increase or decrease
1min. Holding “” or “” button, 2s later, the time will change quickly until
reaching your required time. Press “TIMER ON” to confirm it. The word “ON”
will stop blinking. ” ” icon resumes displaying. Cancel TIMER ON: Under the
condition that TIMER ON is started up, press “TIMER ON” button to cancel it.
TIMER OFF button “TIMER OFF” button can set the time for timer off. After
pressing this button, ” “icon disappears and the word “OFF” on remote
controller blinks. Press “” or “” button to adjust TIMER OFF setting. After
each pressing “” or “” button, TIMER OFF setting will increase or decrease
1min. Holding “” or “” button, 2s later, the time will change quickly until
reaching your required time. Press “TIMER OFF” and the word “OFF” will stop
blinking. ” ” icon resumes displaying. Under the condition that TIMER OFF is
started up, press “TIMER OFF” button to cancel it.
16
NOTE Under on and off status, you can set TIMER OFF or
TIMER ON simultaneously. Before setting TIMER ON or TIMER OFF, please
adjust the clock time. When turning on TIMER ON or TIMER OFF function,
set this function valid all the time and the air conditioner will be turned on
or turned off at set temperature every day. ” ” button has no affect to
setting. If this function is not required, use the remote controller to cancel
it.
button
Press this button to set clock time. ” ” icon on remote controller will blink.
Press “” or “” button within 5s to set clock time. Each pressing of “” or “”
button, clock time will increase or decrease 1 minute. If hold “” or “”
button, 2s later, time will change quickly. Release this button when reaching
your required time. Press “CLOCK” button to confirm the time. ” ” icon stops
blinking.
NOTE Clock time adopts 24-hour mode. The interval between two operations can’t
exceed 5s.
Otherwise, remote controller will quit setting status. Operation for TIMER
ON/TIMER OFF is the same.
button
Press this button, the Quiet status is under the Auto Quiet mode (display ” ”
and “AUTO” signal ) and Quiet mode (display ” ” signal) and Quiet OFF (there
is no signal of ” ” displayed). After powered on, the Quiet OFF is defaulted.
NOTE The quiet function is only available for some models. The Quiet function
can be set up in all modes; Under
the Quiet mode,the fan speed is not available. When quiet function is selected
Under cooling mode: indoor fan operates at notch 4 speed. 10 minutes later or
when indoor ambient temperature 28¥, indoor fan will operate at notch 2 speed
or quiet mode according to the comparison between indoor ambient temperature
and set temperature.
Under heating mode: indoor fan operates at notch 3 speed or quiet mode
according to the comparison between indoor ambient temperature and set
temperature. Under dry, fan mode: indoor fan operates at quiet mode. Under
auto mode: the indoor fan operates at the auto quiet mode according to actual
cooling, heating or fan mode.
button
Press ” WiFi ” button to turn on WiFi function, “WiFi ” icon will be displayed
on the remote controller; Hold ” WiFi ” button for 5s to turn off WiFi
function and ” WiFi ” icon will disappear. Under off status, press “MODE” and
” WiFi ” buttons simultaneously for 1s, WiFi module will restore factory
settings.
NOTE This function is only available for some models.
button
Press this button to turn off display light on indoor unit. ” ” icon on remote
controller disappears. Press this button again to turn on display light. ” ”
icon is displayed.
button
Press this button to turn on or turn off the health and scavenging functions
in operation status. Press this button for the first time to start scavenging
function; LCD displays ” “. Press the button for the second time to start
health and scavenging functions simultaneously; LCD displays ” ” and ” “.
Press this button for the third time to quit health and scavenging functions
simultaneously. Press the button for the fourth time to start health function;
LCD display ” “. Press this button again to repeat the operation above.
NOTE This function is only available for some models.
17
button
By pressing this button, you can see indoor set temperature, indoor ambient
temperature or outdoor ambient temperature on indoor unit’s display. The
setting on remote controller is selected circularly as below:
no display
When selecting ” ” or no display with remote controller, temperature indicator
on indoor unit displays set temperature.
When selecting ” ” with remote controller, temperature indicator on indoor
unit displays indoor ambient temperature.
When selecting ” ” with remote controller, temperature indicator on indoor
unit displays outdoor ambient temperature.
NOTE Outdoor temperature display is not available for some
models. At that time, indoor unit receives ” ” signal, while it displays
indoor set temperature. It’s defaulted to display set temperature when turning
on the unit. There is no display in the remote controller. Only for the models
whose indoor unit has dual-8 display. When selecting displaying of indoor or
outdoor ambient temperature, indoor temperature indicator displays
corresponding temperature and automatically turn to display set temperature
after three or five seconds.
Function introduction for combination buttons
Energy-saving function
Under cooling mode, press “TEMP” and “CLOCK” buttons simultaneously to start
up or turn off energy-saving function. When energy-saving function is started
up, “SE” will be shown on remote controller, and air conditioner will adjust
the set temperature automatically according to ex-factory setting to reach to
the best energy-saving effect. Press “TEMP” and “CLOCK” buttons simultaneously
again to exit energy-saving function.
NOTE Under energy-saving function, fan speed is defaulted
at auto speed and it can’t be adjusted. Under energy-saving function, set
temperature can’t
be adjusted. Press “TURBO” button and the remote controller won’t send signal.
Sleep function and energy-saving function can’t operate at the same time. If
energy-saving function has been set under cool mode, press SLEEP button will
cancel energy-saving function. If sleep function has been set under cool mode,
start up the energy-saving function will cancel sleep function.
8°C heating function
Under heat mode, press “TEMP” and “CLOCK” buttons simultaneously to start up
or turn off 8°C heating function. When this function is started up, ” ” and
“8°C” will be shown on remote controller, and the air conditioner keep the
heating status at 8°C. Press “TEMP” and “CLOCK” buttons simultaneously again
to exit 8°C heating function.
NOTE Under 8°C heating function, fan speed is defaulted at
auto speed and it can’t be adjusted. Under 8°C heating function, set
temperature can’t be ad-
justed. Press “TURBO” button and the remote controller won’t send signal.
Sleep function and 8°C heating function can’t operate at the same time. If 8°
C heating function has been set under heat mode, press SLEEP button will
cancel 8 °C heating function. If sleep function has been set under heat mode,
start up the 8°C heating function will cancel sleep function. Under °F
temperature display, the remote controller will display 46°F heating.
Child lock function
Press “” and “” simultaneously to turn on or turn off child lock function.
When child lock function is on, ” ” icon is displayed on remote controller. If
you operate the remote controller, the ” ” icon will blink three times without
sending signal to the unit.
18
Temperature display switchover function
Under OFF status, press “” and “MODE” buttons simultaneously to switch
temperature display between °C and °F.
Auto clean function
Under unit off status, hold “MODE” and “FAN” buttons simultaneously for 5s to
turn on or turn off the auto clean function. When the auto clean function is
turned on, indoor unit displays “CL” . During the auto clean process of
evaporator, the unit will perform fast cooling or fast heating. There may be
some noise, which is the sound of flowing liquid or thermal expansion or cold
shrinkage. The air conditioner may blow cool or warm air, which is a normal
phenomenon. During cleaning process, please make sure the room is well
ventilated to avoid affecting the comfort. NOTE The auto clean function can
only work under normal
ambient temperature. If the room is dusty, clean it once a month; if not,
clean it once every three months. After the auto clean function is turned on,
you can leave the room. When auto clean is finished, the air conditioner will
enter standby status. This function is only available for some models.
NOTICE
During operation, point the remote control signal sender at the receiving
window on indoor unit.
The distance between signal sender and receiving window should be no more than
8m, and there should be no obstacles between them.
Signal may be interfered easily in the room where there is fluorescent lamp or
wireless telephone; remote controller should be close to indoor unit during
operation.
Replace new batteries of the same model when replacement is required.
When you don’t use remote controller for a long time, please take out the
batteries.
If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
Replacement of batteries in remote controller
signal sender reinstall
battery
remove Cover of battery box
1. Press the back side of remote controller marked with ” “, as shown in the
fig, and then push out the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of “+”
polar and “-” polar are correct.
3. Reinstall the cover of battery box.
19
Test and operation
Check after installation
Check according to the following requirement after finishing installation.
Items to be checked Possible malfunction
Has the unit been installed firmly? Have you done the refrigerant leakage test?
The unit may drop, shake or emit noise. It may cause insufficient cooling(heating) capacity.
Is heat insulation of pipe- It may cause condensation
line sufficient?
and water dripping.
Is water drained well?
It may cause condensation and water dripping.
Is the voltage of power supply according to the voltage marked on the nameplate?
It may cause malfunction or damage the parts.
Is electric wiring and pip- It may cause malfunction or eline installed correctly? damage the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord fol- It may cause malfunction or
low the specification?
damage the parts.
Is there any obstruction in It may cause insufficient the air inlet and outlet? cooling(heating) capacity.
The dust and sundries It may cause malfunction or caused during installation damage the parts. are removed?
The gas valve and liquid valve of connection pipe are open completely?
It may cause insufficient cooling (heating) capacity.
Is the inlet and outlet of It may cause insufficient piping hole been covered?
cooling (heating) capacity
or waste electricity.
Test operation
1. Preparation of test operation The client approves the air conditioner.
Specify the important notes for air conditioner to
the client. 2. Method of test operation Put through the power, press ON/OFF
button on
the remote controller to start operation. Press MODE button to select AUTO,
COOL, DRY,
FAN and HEAT to check whether the operation is normal or not. If the ambient
temperature is lower than 16¥, the air conditioner can’t start cooling.
20
Configuration of connection pipe
1. Standard length of connection pipe: 5m, 7.5m, 8m.
2. Min. length of connection pipe. For the unit with standard connection pipe
of 5m, there is no limitation for the min length of connection pipe. For the
unit with standard connection pipe of 7.5m and 8m, the min length of
connection pipe is 3m.
3. Max. length of connection pipe is shown as below.
Max. length of connection pipe
Cooling capacity
Max. length of connection pipe(m)
5000Btu/h (1465W)
15
7000Btu/h (2051W)
15
9000Btu/h (2637W)
15
12000Btu/h (3516W)
20
18000Btu/h (5274W)
25
24000Btu/h (7032W)
25
28000Btu/h (8204W)
30
36000Btu/h (10548W)
30
42000Btu/h (12306W)
30
48000Btu/h (14064W)
30
4. The calculation method of additional refrigerant oil and refrigerant
charging amount after prolonging connection pipe. After the length of
connection pipe is prolonged for 10m at the basis of standard length, you
should add 5ml of refrigerant oil for each additional 5m of connection pipe.
The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
(1) Additional refrigerant charging amount= prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
(2) Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See Sheet .
Piping size
Indoor unit throttle Outdoor unit throttle
Liquid pipe
Gas pipe
Cooling only, cooling and heating
(g / m)
Cooling only (g / m)
cooling and heating (g / m)
1/4” 1/4” or 3/8”
1/2” 5/8” 3/4” 7/8”
3/8” or 1/2” 5/8” or 3/4” 3/4” or 7/8” 1” or 1 1/4”
16
12
16
40
12
40
Additional refrigerant charging amount for R32
NOTICE The additional refrigerant charging amount in Sheet is recommended
value, not compulsory.
Pipe expanding method
NOTICE Improper pipe expanding is the main cause of refrigerant leakage.
Please expand the pipe according to the following steps:
A: Cut the pipe
Confirm the pipe length according to the distance of indoor unit and outdoor
unit.
Cut the required pipe with pipe cutter.
leaning uneven burr pipe
pipe cutter
80
24
96
136
48
96
200
200
200
280
280
280
21
B: Remove the burrs
Remove the burrs with shaper and prevent the burrs from getting into the pipe.
pipe shaper
downwards
smooth surface
improper expanding
leaning damaged crack uneven
surface
thickness
the length is equal
C: Put on suitable insulating pipe
D: Put on the union nut
Remove the union nut on the indoor connection
pipe and outdoor valve; install the union nut on
union pipe
the pipe.
pipe
E: Expand the port
Expand the port with expander.
expander
hard mold
pipe
NOTICE
“A” is different according to the diameter, please refer to the sheet below:
Outer diameter (mm)
6 – 6.35(1/4″)
A(mm)
Max
Min
1.3
0.7
9 – 9.52(3/8″)
1.6
1.0
12-12.7(1/2″)
1.8
1.0
15.8-16(5/8″)
2.4
2.2
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(°C)
32/23
27/-
Outdoor side DB/WB(°C)
43/26
24/18
For some models:
NOTE The operating temperature range (outdoor tempera-
ture) for Low-temperature cooling only unit is -15°C ~43°C ; for Low-
temperature heat pump unit is -22°C ~43°C.
Maximum cooling
Maximum heating
Indoor side DB/WB(°C)
32/23
27/-
Outdoor side DB/WB(°C)
50/26
30/18
GWH09AFC-K6DNA2F/I(LC)aGWH12AFC-K6DNA2F/I(LC) GWH09AFC-K6DNA3F/IaGWH12AFC-
K6DNA3F/I GWH09AFC-K6DNA5F/IaGWH12AFC-K6DNA5F/I GWH18AFD-K6DNA2I/I(LC
)aGWH18AFD-K6DNA5I/I(LC) GWH24AFE-K6DNA5I/IaGWH24AFE-K6DNA2I/I(LC)
NOTE The operating temperature range (outdoor tempera-
ture) for Low-temperature cooling only unit is -15°C ~50°C ; for heat pump
unit is -15°C~50°C.
F: Inspection
Check the quality of expanding port. If there is any blemish, expand the port
again according to the steps above.
22
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(°C)
32/23
Outdoor side DB/WB(°C)
50/26
27/-
30/18
GWH09AFC-K6DNA2F/I(LCLH)aGWH09AFC-K6DNA1F/I GWH12AFC-K6DNA2F/I(LCLH)aGWH12AFC-
K6DNA1F/I GWH18AFD-K6DNA2I/I(LCLH)aGWH18AFD-K6DNA1I/I GWH18AFD-K6DNA5I/I(LCLH
)aGWH18AFD-K6DNA3I/I GWH24AFE-K6DNA1I/IGWH24AFE-K6DNA2I/I(LCLH)
GWH24AFE-K6DNA3I/I
NOTE The operating temperature range (outdoor tempera-
ture) for Low-temperature cooling only unit is -15°C ~50°C ; for Low-
temperature heat pump unit is -25°C ~50°C.
23
Specialist’s Manual
The following checks shall be applied to installations using flammable
refrigerants: the charge size is in accordance with the room size within
which the refrigerant containing parts are installed; the ventilation
machinery and outlets are operating adequately and are not obstructed; if an
indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant; marking to the equipment continues
to be visible and legible. Markings and signs that are illegible shall be
corrected; refrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which may corrode
refrigerant containing components, unless the components are constructed of
materials which are inherently resistant to being corroded or are suitably
protected against being so corroded.
Repair and maintenance to electrical components shall include initial safety
checks and component inspection procedures. If a fault exists that could
compromise safety, then no electrical supply shall be connected to the circuit
until it is satisfactorily dealt with. If the fault cannot be corrected
immediately but it is necessary to continue operation, an adequate temporary
solution shall be used. This shall be reported to the owner of the equipment
so all parties are advised.
Initial safety checks shall include: that capacitors are discharged: this
shall be done in a safe manner to avoid possibility of sparking; that no
live electrical components and wiring are exposed while charging, recovering
or purging the system; that there is continuity of earth bonding.
Checking for presence of refrigerant The area shall be checked with an
appropriate refrigerant detector prior to and during work, to ensure the
technician is aware of potentially toxic or flammable atmospheres. Ensure that
the leak detection equipment being used is suitable for use with all
applicable refrigerants, i.e. non-sparking, adequately sealed or intrinsically
safe.
Presence of fire extinguisher If any hot work is to be conducted on the
refrigeration equipment or any associated parts, appropriate
fire extinguishing equipment shall be available to hand. Have a dry powder or
CO2 fire extinguisher adjacent to the charging area.
Ventilated area Ensure that the area is in the open or that it is adequately
ventilated before breaking into the system or conducting any hot work. A
degree of ventilation shall continue during the period that the work is
carried out. The ventilation should safely disperse any released refrigerant
and preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment Where electrical components are being
changed, they shall be fit for the purpose and to the correct specification.
At all times the manufacturer’s maintenance and service guidelines shall be
followed. If in doubt, consult the manufacturer’s technical department for
assistance.
Checks to electrical devices that capacitors are discharged: this shall be
done in a safe manner to avoid possibility of sparking; that no live
electrical components and wiring are exposed while charging, recovering or
purging the system.
Repairs to sealed components During repairs to sealed components, all
electrical supplies shall be disconnected from the equipment being worked upon
prior to any removal of sealed covers, etc. If it is absolutely necessary to
have an electrical supply to equipment during servicing, then a permanently
operating form of leak detection shall be located at the most critical point
to warn of a potentially hazardous situation. Particular attention shall be
paid to the following to ensure that by working on electrical components, the
casing is not altered in such a way that the level of protection is affected.
This shall include damage to cables, excessive number of connections,
terminals not made to original specification, damage to seals, incorrect
fitting of glands, etc. Ensure that the apparatus is mounted securely.
Ensure that seals or sealing materials have not degraded to the point that
they no longer serve the purpose of preventing the ingress of flammable
atmospheres. Replacement parts shall be in accordance with the manufacturer’s
specifications. NOTE:The use of silicon sealant can inhibit the effectiveness
of some types of leak detection equipment. Intrinsically safe components do
not have to be isolated prior to working on them.
24
Specialist’s Manual
Repair to intrinsically safe components Do not apply any permanent inductive
or capacitance loads to the circuit without ensuring that this will not exceed
the permissible voltage and current permitted for the equipment in use.
Intrinsically safe components are the only types that can be worked on while
live in the presence of a flammable atmosphere. The test apparatus shall be at
the correct rating. Replace components only with parts specified by the
manufacturer. Other parts may result in the ignition of refrigerant in the
atmosphere from a leak.
Cabling Check that cabling will not be subject to wear, corrosion, excessive
pressure, vibration, sharp edges or any other adverse environmental effects.
The check shall also take into account the effects of aging or continual
vibration from sources such as compressors or fans.
Detection of flammable refrigerants Under no circumstances shall potential
sources of ignition be used in the searching for or detection of refrigerant
leaks. A halide torch (or any other detector using a naked flame) shall not be
used.
Leak detection methods Leak detection fluids are suitable for use with most
refrigerants but the use of detergents containing chlorine shall be avoided as
the chlorine may react with the refrigerant and corrode the copper pipe-work.
Decommissioning Before carrying out this procedure, it is essential that the
technician is completely familiar with the equipment and all its detail. It is
recommended good practice that all refrigerants are recovered safely. Prior to
the task being carried out, an oil and refrigerant sample shall be taken in
case analysis is required prior to re-use of reclaimed refrigerant. It is
essential that electrical power is available before the task is commenced. a)
Become familiar with the equipment and its operation. b) Isolate system
electrically. c) Before attempting the procedure, ensure that: mechanical
handling equipment is available, if required, for handling refrigerant
cylinders; all personal protective equipment is available and being used
correctly; the recovery process is supervised at all times by a competent
person;
recovery equipment and cylinders conform to the appropriate standards. d)
Pump down refrigerant system, if possible. e) If a vacuum is not possible,
make a manifold so that refrigerant can be removed from various parts of the
system. f) Make sure that cylinder is situated on the scales before recovery
takes place. g) Start the recovery machine and operate in accordance with
manufacturer’s instructions. h) Do not overfill cylinders. (No more than 80%
volume liquid charge). i) Do not exceed the maximum working pressure of the
cylinder, even temporarily. j) When the cylinders have been filled correctly
and the process completed, make sure that the cylinders and the equipment are
removed from site promptly and all isolation valves on the equipment are
closed off. k) Recovered refrigerant shall not be charged into another
refrigeration system unless it has been cleaned and checked.
Labelling Equipment shall be labelled stating that it has been de-commissioned
and emptied of refrigerant. The label shall be dated and signed. For
appliances containing flammable refrigerants, ensure that there are labels on
the equipment stating the equipment contains flammable refrigerant.
Recovery When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely. When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge are available.
All cylinders to be used are designated for the recovered refrigerant and
labelled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure-relief valve and
associated shut-off valves in good working order. Empty recovery cylinders are
evacuated and, if possible, cooled before recovery occurs. The recovery
equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of all
appropriate refrigerants including, when applicable, flammable refrigerants.
In ad-
25
Specialist’s Manual
dition, a set of calibrated weighing scales shall be available and in good
working order. Hoses shall be complete with leak-free disconnect couplings and
in good condition. Before using the recovery machine, check that it is in
satisfactory working order, has been properly maintained and that any
associated electrical components are sealed to prevent ignition in the event
of a refrigerant release. Consult manufacturer if in doubt. The recovered
refrigerant shall be returned to the refrigerant supplier in the correct
recovery cylinder, and the relevant waste transfer note arranged. Do not mix
refrigerants in recovery units and especially not in cylinders. If compressors
or compressor oils are to be removed, ensure that they have been evacuated to
an acceptable level to make certain that flammable refrigerant does not remain
within the lubricant. The evacuation process shall be carried out prior to
returning the compressor to the suppliers. Only electric heating to the
compressor body shall be employed to accelerate this process. When oil is
drained from a system, it shall be carried out safely.
26
66139902148
Read User Manual Online (PDF format)