YASKAWA SOLECTRIA SOLAR All XGI 1000 Advanced Inverter Controls User Manual

June 10, 2024
YASKAWA SOLECTRIA SOLAR

YASKAWA SOLECTRIA SOLAR All XGI 1000 Advanced Inverter Controls

YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
product

Product Information

The Advanced Inverter Controls Remote Access PortalTM RAP is an IoT solution that provides easy and secure remote access to Solectria XGI 1000 and XGI 1500 inverters. With a single internet-based web portal, multiple users can access the entire inverter fleet simultaneously. The RAP allows users to remotely change settings, perform diagnostics, update firmware, and restart inverters. The RAP setup is flexible and allows customers the autonomy to add, delete, and manage users independently, without the need to contact Yaskawa Solectria Support. Users can be assigned permissions to access the entire inverter fleet or only a single inverter, providing the highest level of security.

Product Usage Instructions

  1. Review the XGI Inverter Installation and Operations manual for detailed instructions on how to install and commission the XGI communication network. It is important to complete the onsite communication commissioning process before attempting to connect inverters to the RAP.
  2. Access Solectria RAP using any popular web browser by logging in at https://remote.solar. The web portal interface is configured according to the privileges or Roles assigned to a particular user.
  3. For first-time setup, Yaskawa Solectria Technical Support will identify one or more Tenant Administrators within a group of RAP users. One Tenant is assigned to each organization or company. The designated Tenant Administrators then have the ability to generate additional users and assign Roles to them.
  4. When a new user is created either by Yaskawa Solectria Technical Support or by a Tenant Administrator an email notification will be sent to the new user according to the email provided. The email contains a link that is used to log in for the first time and establish a password. Users must set up a password before they can access the RAP.

SAVE THESE INSTRUCTIONS
This manual contains important instructions for models:

Introduction – Solectria Remote Access Portal (RAP)

Solectria Remote Access Portal (RAP) provides easy and secure remote access to Solectria XGI inverters. With a single internet-based web portal, multiple users can access the entire inverter fleet simultaneously in a secure, easy- to-use, IoT solution. With the RAP, users can access inverters in the same manner they would onsite, with complete control of their fleet from anywhere in the world. With the ability to remotely change settings, perform diagnostics, update firmware, and restart inverters, the RAP makes the Solectria XGI smart inverters truly smart. The RAP setup is flexible allowing customers the autonomy to add, delete, and manage users independently, without the need to contact Yaskawa Solectria Support. Users can be assigned permissions to access the entire inverter fleet or only a single inverter, providing the highest level of security.

RAP, First-Time Setup

Review the XGI Inverter Installation and Operations manual for detailed instruction on how to install and commission the XGI communication network. It is important to complete the onsite communication commissioning process before attempting to connect inverters to the RAP.

RAP, Tenant Administrators

Solectria RAP is accessed using any popular web browser, by logging in at https://remote.solar. The web portal interface is configured according to the privileges or Roles assigned to a particular user. Roles are assigned and controlled by one or more Tenant Administrators.

INFO ✔

Tenant Administrator: A user with full administrative rights. Has the ability to:

  • Create users
  • Delete users
  • Edit user accounts
  • Assign Roles
  • Assign Privileges

Roles: Used to group a set of privileges, Roles can only be created by Yaskawa Solectria Technical Support.

For first time setup, Yaskawa Solectria Technical Support will identify one or more Tenant Administrators within a group of RAP users. One Tenant is assigned to each organization or company. The designated Tenant Administrators then have the ability to generate additional users and assign Roles to them.

REMOTE ACCESS PORTAL ADMINISTRATOR’S GUIDE

YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-1

First Time Login

When a new user is created, either by Yaskawa Solectria Technical Support, or by a Tenant Administrator an email notification will be sent to the new user according to the email provided. The email contains a link which is used to login for the first time and establish a password. Users must setup a password before they are able to access the RAP. Enter the assigned Username, type the desired New Password, and then re-enter or, Verify password. Click on Set new password, the user is then prompted to login.YASKAWA-SOLECTRIA-SOLAR-All-
XGI-1000-Advanced-Inverter-Controls-fig-2

INFO ✔

  • If you have not received an email link, contact your Tenant Administrator or the Yaskawa Solectria Technical Support team.
  • Passwords for individual users are not accessible by administrators or Yaskawa Solectria Technical Support, use the Forgot password? function on the login page to reset a password.
  • Users are only able to login if they have been granted access to a Device or Domain and their user profile has been granted appropriate privileges.

Creating a User
Tenant Administrators have the privileges to create new RAP users as well as manage the access to specific devices within their XGI fleet. This allows the Tenant Administrators to control the access that specific users have down to the inverter level. Users are not able to access the RAP unless they have been given access to at least one Device or Domain.

INFO ✔

  • Device: A “Device” in the RAP is an individual inverter. Access to devices can be assigned to any user, simply select Device in the Type column, and enter the inverter Serial Number (all alphabetical characters must be lower case.)
  • Domain: A “Domain” in the RAP represents a Cluster of inverters. The Domain of a Cluster is the Serial Number of the Gateway inverter (all alphabetical characters must be lower case.) Access to Domains can be assigned to any user, simply select Domain in the Type column, and enter the serial number of the gateway inverter. When providing access to a Cluster, the user will have access to all inverters within the cluster.

To create a new User, login as a Tenant Administrator and navigate to the Users tab, click on Create user. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000
-Advanced-Inverter-Controls-fig-3

Enter the desired Username and Email Address. We encourage Usernames to be the leading portion of the users email address. For example if the users email is “newuser@solar_company.com” the username should be “newuser”. Leave the Send Invite Email check box selected and click Create user. An email notification will be sent to the email address provided, prompting the user to setup a password. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000
-Advanced-Inverter-Controls-fig-4

A role must be assigned to the new user to complete the process, for more information see Section 2.1.3.2. Select User for User assignment, or both User and TenantAdmin to create a new Tenant Administrator. YASKAWA-SOLECTRIA-
SOLAR-All-XGI-1000-Advanced-Inverter-Controls-fig-5

IMPORTANT ✔

  • Before the newly created user can successfully login, a role must be assigned, see Section 2.1.3.2 User Roles.

Managing Existing Users
Tenant Administrators can manage permissions, roles, and users profiles, as well as delete existing users. All of these actions are performed in the User tab of the RAP.

Assigning Permissions
All users must be assigned permissions in order to access the RAP and view devices. Access to inverters can be assigned individually (per inverter) or as a group by the Cluster or Domain. All permissions are granted to each user individually, by selecting the user from the list on the User tab.YASKAWA-
SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-6

To grant users access to inverter clusters or individual inverters, add permissions to each User. From the User tab, select the desired User and click on Edit Permissions. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-
Controls-fig-7

Select the Type from the dropdown menu choose either Device or Domain and enter the desired Serial Number.YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000
-Advanced-Inverter-Controls-fig-8

IMPORTANT ✔

When entering a Serial Number, all alphabetical characters must be entered in lowercase “1w…” not “1W…”

User Roles
Roles are used in the RAP to assign a set of permissions to a specific user. To add or remove a Role from a user, navigate to the User tab, select the user and click on Edit Roles. Assign Roles by selecting the check box next to the desired Role.YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-
Controls-fig-9

Tenant Administrators are able to assign Roles to others, only if they are assigned those Roles. Most Tenant Administrators will be able to assign the following Roles; User, and TentantAdmin. Assigning roles will also automatically update certain permissions.

Roles Permissions Description
User reflector.device.port:80 Allows access to the webpages of the

inverters.
TenantAdmin| tenantAdmin| Allows the user to administer the Tenant.
| reflector.user.*| Allows the user to modify user accounts of the Tenant.

User Profiles
All User Profiles can be edited by a Tenant Administrator. Navigate to the User tab, by default the User Profile will appear, otherwise, select Edit user profile.YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-11

The following fields can be edited:

  • First Name: Text field, first name of user, searchable keyword.
  • Last Name: Text field, surname of user, searchable keyword.
  • Organization: Text field, searchable keyword.
  • Email Address: Email address used for password reset and other notifications
  • Tags: Text field, generic field to add additional searchable keywords.
  • Password: Left blank, managed by the individual user through email on while logged into to the RAP.
  • Login Disabled: Check box to disable a specified user

Resetting User Passwords
Tenant Administrators do not have access to other Users passwords, however, they are able to initiate a password reset. To start the password reset process, login as a Tenant Administrator and navigate to the User tab. Select the desired user, and click on Send password reset email. An email will be sent using the email specified in the User Profile with a link to reset the password.

INFO ✔

  • Check SPAM! If the email to reset a password is not being received, check the spam folder. Some email servers may send these notifications to SPAM or JUNK.

RAP, Users

General users must first be given an account from a Tenant Administrator. Typically they receive an invitation email with a link to set up their password. The username given to them by the Tenant Administrator is specified in the login email. Once logged in, a user account is fully functional. There are several fields that can be edited if desired. To self-modify a user profile, login to the RAP using your username and password. Navigate to the Account tab, by clicking on the blue user icon with your username.YASKAWA-
SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-12

The user has several options, including the ability to Change password, Sign out, edit the associated name and organization, and adjust the number of Items [devices] per Page. For any of these changes to take place, they must be saved.

Two-Factor Authentication
Two-Factor Authentication must be enabled by the individual user.YASKAWA-
SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-13

User administrator accounts cannot enable it for other users. They will need to install an authenticator app on their phone. Google Authenticator is used in this example. The user can enable Two-Factor authentication by going to their user profile page and clicking the “disabled” link. On the next screen, they would need to click to the “Enable two-factor authentication” button .YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-14

Next, the user will need to enter their account password again to confirm activation. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-15

The user will then need to use their authenticator app to either scan in the QR code or manually enter in the setup key. The authenticator app will then provide a password for the user to enter. After this, setup is complete .YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-16

Utilizing the RAP

The RAP is an advanced, secure, easy way for solar owners and operators to access and interact with all of their Solectria XGI inverters. For the RAP to function the inverters must be connected to the internet.

Accessing an Inverter/Cluster
All inverters are accessed by selecting them from the Device tab, the default display when logging into the RAP. Devices can be filtered according to their connection Status; Online, Offline, or All Devices. A keyword search is also provided to quickly search for devices. The number of devices online and total number of devices licensed is displayed under the username along with the license expiration date.YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000
-Advanced-Inverter-Controls-fig-17

Each device has several columns that displays important information regarding the inverters. A description of each column is provided in Table 3-1.

DESCRIPTION

Table 3-1, Device tab column descriptions

COLUMN NAME DESCRIPTION
DEVICE The Name of the inverter, programmed into the inverter at

commissioning, extracted

directly from the inverter and displayed in the RAP.

STATUS| The connection status of the device, Online or Offline. This does not indicate the

operational status of the inverter, only the connection status

SITE| Site Name, programmed into the inverter at commissioning, extracted directly from the

inverter and displayed in the RAP. This is the first portion of the WIFI SSID, SITE -XX-XXX

CLUSTER| Cluster Number, programmed into the inverter at commissioning, extracted directly from the inverter and displayed in the RAP. This is the second portion of the WIFI SSID, XXX- 01

XXX

SERIAL NUMBER| The Serial Number of the inverter, extracted directly from the inverter and displayed in the

RAP.

MODEL| The Model of the inverter, extracted directly from the inverter and displayed in the RAP.
LOCAL IP ADDRESS| The IP address of the inverter, extracted directly from the inverter and displayed in the

RAP.

MAC ADDRESS| The MAC address of the inverter, extracted directly from the inverter and displayed in the

RAP.

DOMAIN| The Serial Number of the Gateway Inverter, used to specify permissions of inverters to

users.

To interact with an inverter, simply click on the device. Your web browser will be redirected to the XGI GUI of the device selected. Depending on the user privileges, the user can then access other inverters within that Cluster by navigating within the GUI. The user experience once connected to the GUI is identical to that when connected over Ethernet or WiFi onsite.

Configuring XGI Inverters for use with the RAP

For the RAP to function properly it is important to ensure the inverters are properly installed, and the network configuration is designed appropriately. For more details on the installation and network requirements of the XGI Inverters please see the XGI 1000 and XGI 1500 Installation and Operations Manuals. This section details important steps required specifically for use with the RAP.

Supported Network Topologies
The XGI inverters support several different network topologies including; Daisy Chain, Mixed Networks, and Multi-Cluster configurations.YASKAWA-
SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-18 YASKAWA-SOLECTRIA-
SOLAR-All-XGI-1000-Advanced-Inverter-Controls-fig-19YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-
Inverter-Controls-fig-20

Registering an Inverter/Cluster in the RAP
All new XGI Clusters need to be registered to a Tenant Administrator, this is done by entering the Tenant ID into the Gateway Inverter’s Remote Access Configuration page (See Section 5.2). Once the devices are registered the Tenant Administrator can assign privileges to their users.

Licensing

New Customer
When a new customer is acquired or an existing customer wants to use the RAP, a Tenant ID should be created for them. See Figure 2-1.

New Customer Site
Every time a new customer site is brought online, the commissioning team should set the Tenant ID in the GUI of the gateway inverter.YASKAWA-
SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-21

INFO ✔

  • After saving, allow 15-30 minutes for server to update the permissions/access.

The commissioning team will be responsible for entering the information The Tenant ID is displayed in the User Profile, which can be accessed by clicking on the username link. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-
Inverter-Controls-fig-22

Expiration of License

When the Remote Access Portal License expires, you will be notified on sign in attempt. YASKAWA-SOLECTRIA-SOLAR-All-XGI-1000-Advanced-Inverter-Controls-
fig-23

Please contact the Sales Support team to renew your license.

Appendix

Contact Information

Table 6-1 Contact Information

TELEPHONE 978.683.9700
FAX 978.683.9702
SALES SUPPORT [email protected]

TECHNICAL SUPPORT &

SERVICE

| 978.683.9700×2
WEBSITE| www.solectria.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

YASKAWA SOLECTRIA SOLAR User Manuals

Related Manuals