INSTRUCTIONS
Before using or installing the product, kindly read the instructions and follow safety rules. Installation should be provided by qualified person or company.
Thank you for choosing the item of company PAN LUX s.r.o.
Technical data
Recommended installation height: 4 – 15m
Material: plastic
Notice
Before using, check the product and make sure it is not damaged in any way,
otherwise do not use it. Before every manipulation make sure that mains
electrical supply is disconnected. In case of damage do not repair or
disassemble the product. For the best functional results, move toward the
sensor. The incorrect function of the product can be caused by interruption of
electromagnetic field, reflection (e.g. strong luminous source).
Infringement of any mentioned instruction can cause harm to health or
property.
Warranty voids, if the product is mechanically damaged or connected
unprofessionally.
SENSOR SETUP
Principle of sensor
The integrated radar (HF) sensor emits high-frequency waves (5,8 GHz) and
receives the echo. The sensor detects the change in echo from even the
slightest movement within its detection zone. A microprocessor then triggers
the process to switch the lamp on. The transmitted electromagnetic waves lead
to different large reflections and reductions according to the type of
material of the obstacles.
**Time setting (switch-off delay) – TIME (5 (±5)s – 30(±2)min)***
The countdown of the selected time begins after the last detected movement. We
recommend selecting the minimum time during functional testing.
**Light sensitivity setting – LUX (2-2000)***
We highly recommend setting LUX to maximum so the sensor will work in daylight
during functional testing
**Reach setting (sensitivity) – max. 1Om***
Reach is the area traced out by the angle of detection and the minimum to
maximum possible distance from the sensor. Reach can be changed by rotating
the head of the sensor.
*) These figures are approximate, and may vary depending on position and mounting height.