PEmicro PROGPPCZ Software User Guide
- June 10, 2024
- PEmicro
Table of Contents
- Introduction
- Startup
- Programming Commands
- Configuration Commands For Startup
- Verification Overview
- DOS Error Returns
- Example Programming Script File
- Using Command-Line Parameters in a Script
- Sample Batch File
- Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CPROGPPCZ User Guide
Introduction
CPROGPPCZ is a Windows command-line version of the PROGPPCZ software which
programs Flash, EEPROM, EPROM, etc. through a PEmicro hardware interface to a
supported NXP Power Architecture 5xx/8xx processor. The hardware interfaces
are available from PEmicro.
Once your interface hardware is properly connected between your PC and target
device, you may launch the CPROGPPCZ executable from the command line. In
addition to the executable, multiple command-line parameters must also be
passed in order to configure which PEmicro hardware interface CPROGPPCZ should
attempt to connect to, and to configure how that hardware interface will
connect to the target device. These parameters include the name of the
configuration (.CFG) file, as well as startup commands such as the name of the
hardware interface or the port to which the interface is connected.
The .CFG file specifies how to program the target as you intend, and it
includes standard programming commands and, optionally, configuration
commands. The following chapters will provide a detailed explanation of these
commands and parameters.
Startup
a. Connect the hardware interface between your PC and the target MCU via the
debug ribbon cable.
b. Start the programming software by running it from the Windows Command
prompt or by calling the CPROGPPCZ executable with the correct command line
parameters. Allowed command line parameters are:
CPROGPPCZ [?/!] [filename] [/PARAMn=s] [v] [reset_delay n] [bdm_speed n]
[hideapp] [freq n] [Interface=x] [port=y] [showports] [/logfile logfilename]
where:
[?/!] Use the ‘?’ or’ ‘!’ character option to cause the command-line
programmer to wait and display the result of programming in the PROGPPCZ
window. ‘?’ will always display the result, ‘!’ will display the result only
if an error occurred. If the user does not use a batch file to test error
level, this provides a method to display the programming result. This option
should be the FIRST command-line option.
[filename] A command-line parameter which can modify the executing script
by replacing special tags (/PARAMn). This can be used to replace any part of
the script including programming commands, filenames, and parameters. Valid
values of n are 0..9. s is a string which will replace any occurrence of
/PARAMn in the script file. Section 8 – Using CommandLine Parameters in a
Script has an example for usage.
[INTERFACE=x] Where x is one of the following: (See examples section)
USBMULTILINK (This setting also supports OSBDM) CYCLONE
PARALLEL (Parallel Port or BDM Lightning [Legacy])
[PORT=y] Where the value of y is one of the following (see the showports
command-line parameter for a list of connected hardware; always specify the
“interface” type as well):
USBx
Where x = 1,2,3, or 4. Represents an enumeration number for each piece of
hardware starting at 1. Useful if trying to connect to a Cyclone or Multilink
product. If only one piece of hardware is connected, it will always enumerate
as USB1.
An example to select the first Multilink found is: INTERFACE=USBMULTILINK
PORT=USB1
#.#.#.#
Ethernet IP address #.#.#.#. Each # symbol represents a decimal number
between 0 and 255. Valid for Cyclone and Tracelink interfaces.
Connection is via Ethernet.
INTERFACE=CYCLONE PORT=10.0.1.223
NAME
Some products, such as the Cyclone and Tracelink, support assigning a name
to the unit, such as “Joe’s Max”. The Cyclone may be referred to by it’s
assigned name. If there are any spaces in the name, the whole parameter should
be enclosed in double quotes (this is a Windows requirement, not a PEmicro
requirement).
Examples:
INTERFACE=CYCLONE PORT=MyCyclone99 INTERFACE=CYCLONE “PORT=Joe’s Cyclone”
UNIQUEID
USB Multilink products all have a unique serial number assigned to them,
such as PE5650030.
The Multilink may be referred to this number.
This is useful in the case where multiple units are connected to the same PC.
Examples:
INTERFACE=USBMULTILINK PORT=PE5650030
COMx
Where x = 1,2,3, or 4. Represents a COM port number. Valid for Cyclone
interfaces.
To connect to a Cyclone on COM1 :
INTERFACE=CYCLONE PORT=COM1
x
Where x = 1,2,3, or 4. Represents a parallel port number
To select a parallel interface on Parallel Port #1 :
INTERFACE=PARALLEL PORT=1
PCIx
Where x = 1,2,3, or 4. Represents a BDM Lightning card number. (Note: this
is a legacy product)
To select a parallel cable on BDM Lightning #1 :
INTERFACE=PARALLEL PORT=PCI1
[showports] The command-line programmer outputs all available ports to a
text file and then terminates (regardless of other commandline parameters).
This information output to the text file includes the parameters needed to
contact attached programming hardware as well as a description of the hardware
interface. The default output filename is ports.txt and is created in the same
folder as CPROG.
The output can also be directed to a different file.
Example: SHOWPORTS=C:\MYPORTS.TXT
This list does not show parallel port or COM port options which are also
available. Below is an example of the output for various hardware interfaces
connected to the PC Note that there are different ways to address the same
unit; the data for each interface may be followed by a [DUPLICATE] line which
shows a different label for the same interface).
Showports Output Example:
INTERFACE=USBMULTILINK PORT=PE5650030
; USB1 : Multilink Universal FX Rev A (PE5650030)[PortNum=21]
INTERFACE=USBMULTILINK PORT=USB1
; USB1 : Multilink Universal FX Rev A (PE5650030)[PortNum=21][DUPLICATE]
INTERFACE=CYCLONE PORT=10.0.9.197
; 10.0.9.197 : Public Cyclone [PortNum=61] INTERFACE=CYCLONE “PORT=Public
Cyclone”
; 10.0.9.197 : Public Cyclone[PortNum=61][DUPLICATE] INTERFACE=CYCLONE
“PORT=Joe’s Cyclone”
; USB1 : Cyclone (Joe’s)[PortNum=101] INTERFACE=CYCLONE PORT=USB1
; USB1 : Cyclone (Joe’s)[PortNum=101][DUPLICATE] [v] Causes the programmer
not to check the range of S-record addresses before programming or verifying.
This speeds up the programming process. The option should be used with care as
all out of range s-records will be ignored.
[reset_delay n] Specifies a delay after the programmer resets the target
that we check to see if the part has properly gone into background debug mode.
This is useful if the target has a reset driver which hold the MCU in reset
after the programmer releases the reset line. The n value is a delay in
milliseconds.
[bdm_speed n] This option allows the user to set the BDM shift clock
speed of PEmicro’s debug interface. This integer value may be used to
determine the speed of communications according to the following equations:
USB Multilink (includes Universal): (1000000/(N+1)) Hz
USB Multilink Universal FX: (25000000/(N+1)) Hz
Cyclone or Tracelink: (50000000/(2N+5)) Hz
BDM Lightning : (33000000/(2N+5)) Hz – Legacy product
The value n should be between 0 and 31. This shift clock takes effect after
the commands in the top of the programming algorithm are executed so that
these commands can increase the target frequency and allow a faster shift
clock. This clock can’t generally exceed a div 4 of the processor bus
frequency.
[hideapp] This will cause the command-line programmer to not display a
visual presence while running with the exception of appearing on the taskbar.
32-bit applications only!
[freq n] By default, the PROGPPCZ software tries to determine
automatically how fast the target is running by loading a delay routine in the
processor and timing how long it takes to execute. On some machines, this may
yield inconsistent results which may affect algorithms which program flash
internal to an MCU. PEmicro provides a command-line mechanism allowing the
user to inform the PROGPPCZ software exactly how fast the target processor is
running. In this way, the timing in the algorithms will be precise. On the
command-line, you specify the INTERNAL clock frequency in Hertz following the
‘FREQ’ identifier. Note that in general if you are using a flash device
external to the MCU, this timing parameter is not needed as the flash handles
the timing itself.
[/logfile logfilename] This option opens a logfile of the name
“logfilename” which will cause any information which is written to the status
window to also be written to this file. The “logfilename” should be a full
path name such as c:\mydir\mysubdir\mylog.log.
Command Line Examples:
CPROGPPCZ C:\ENGINE.CFG INTERFACE=USBMULTILINK PORT=PE5650030
Opens CPROGPPCZ with the following options:
– Run the C:\ENGINE.CFG script
– Interface is first USB Multilink Universal FX with serial number PE5650030
– Autodetect communications frequency (io_delay_cnt not set)
CPROGPPCZ C:\ENGINE.CFG Interface=CYCLONE Port=209.61.110.251
Opens CPROGPPCZ with the following options:
– Run the C:\ENGINE.CFG script
– Interface is Cyclone Max via the Ethernet Port with an IP address of
209.61.110.251
CPROGPPCZ C:\ENGINE.CFG Interface=USBMULTILINK Port=USB1
Opens CPROGPPCZ with the following options:
– Run the C:\ENGINE.CFG script
– Interface is USB Multilink Universal FX, first interface detected.
Programming Commands
Programming commands all start with a two character sequence followed by white
space (blanks or tabs). Lines starting with characters which are not commands
are listed as REMarks. The term filename means a full DOS path to a file.
Commands use the same two letter codes as used in the interactive programmers
PROGPPCZ. The same .PCP files used by PROGPPCZ are used to set up for a
particular device to be programmed. If a user function is specified for a
particular device, its two character command and the meaning or user_par are
specified in the .PCP file.
Note: The command parameters starting_addr, ending_addr, base_addr, byte,
word, and user_par use a default hexadecimal format.
BM | – Blank check module. |
---|---|
BR starting_addr ending_addr | – Blank check range. |
CHANGEV n.nn | – (Cyclone only) Change the voltage provided to the target, |
where n.nn represents a value between 0.00 and 5.00, inclusive. When the
command executes the Cyclone will immediately change to that voltage. If the
Cyclone relays are off prior to calling this command, then the relays will
turn on and set the new voltage value when this command is executed. Note that
too low of a voltage value may put the device into low-power mode which can
lose debug communication altogether. Make sure the Cyclone’s jumper settings
are set correctly to send the power to the right ports.
EB starting_addr ending_addr| – Erase byte range.
EW starting_addr ending_addr| – Erase word range.
EM| – Erase module
PB starting_addr byte … byte| – Program bytes.
PW starting_addr word … word| – Program words.
PM| – Program module.
CM filename base_addr| – Choose module .PCP file. Note: Certain modules may
require a base address to be specified.
VM| – Verify module.
VR starting_addr ending_addr| – Verify range.
UM filename| – Upload module.
UR starting_addr ending_addr filename| – Upload range.
SS filename| – Specify S record.
SM starting_addr ending_addr| – Show module.
RELAYSOFF| – (Multilnk FX & Cyclone only) Turn off the relays that provide
power to the target, including a power down delay if specified. Especially
useful for users who want to power cycle their board before running tests,
allow their bootloader to run, or have the application code run after
programming.
RELAYSON| – (Multilnk FX & Cyclone only) Turn on the relays to provide power
to the target, including a power up delay if specified. The voltage supplied
will be based on the last voltage setting pecified. For Cyclone users, the
CHANGEV command can change the voltage value. Especially useful for users who
want to power cycle their board before running tests, allow their bootloader
to run, or have the application code run after programming.
HE| – Help (look at cprog.doc file).
QU| – Quit.
RE| – Reset chip.
GO| – Starts device running. Can be used as final command if you want the
device to run for testing. Should be immediately preceded by an ‘RE’ command.
DE timeinms| – Delays “timeinms” milliseconds
xx user_par| – Only for user function specified in .PCP file.
Configuration Commands For Startup
Configuration commands are all processed before the programmer attempts to
contact the target. The whole configuration file is parsed for these commands
prior to attempting communications. This section gives an overview of using
these configuration commands to do different type of configuration.
Note: The default base for configuration command parameters is decimal.
An overview of the configuration commands is as follows:
:CUSTOMTRIMREF nnnnnnnn.nn
Desired internal reference clock frequency for the “PT; Program Trim” command.
This frequency overrides the default internal reference clock frequency. Valid
values for “n” depend on the particular device being programmed. Please refer
to the electrical specifications of your device for valid internal reference
frequency clock range.
Where:
nnnnnnnn.nn: Frequency in Hertz with two decimal places
:DEVICEPOWER n
For Cyclone (excludes Cyclone MAX). This setting defines the target voltage
that will be provided to the target if the source of the voltage is derived
from the Cyclone’s internal power. Valid values of n are:
0 : 5 Volts, Generated/Switched by Cyclone
2 : 3 Volts, Generated/Switched by Cyclone
4 : 2 Volts, Generated/Switched by Cyclone
:PROVIDEPOWER n
Determines whether interface should provide power to the target. NOTE: Not
all hardware interfaces support this command. Valid values of n are:
0 : Interface does not provide power to target. (default)
1 : Enable Interface provides power to target.
(NOTE: Is the same as legacy option :USEPRORELAYS n)
:POWERDOWNDELAY n
Amount of time to delay when the power to the target is turned off for the
targets power supply to drop to below 0.1v. n is the time in milliseconds.
:POWERUPDELAY n
Amount of time to delay when the power to the target is turned on OR the
target is reset, and before the software attempts to talk to the target. This
time can be a combination of power on time and reset time (especially if a
reset driver is used). n is the time in milliseconds.
:POWEROFFONEXIT n
Determines whether power provided to the target should be turned off when the
CPROGPPCZ application terminates. NOTE: Not all hardware interfaces
support this command. Valid values of n are:
0 : Turn power off upon exit (default)
1 : Keep power on upon exit
Verification Overview
There are several commands available that can be used to verify the contents
of the flash on the device after programming it. The most widely used command
is “VC ;Verify CRC of Object File to Module”. The “VC” command will instruct
CPROGPPCZ to first calculate a 16-bit CRC value from the chosen object file.
CPROGPPCZ will then load code into the RAM of the device and instruct the
device to calculate a 16 bit CRC value from the contents in FLASH of the
device. Only valid address ranges in the object file are calculated on the
device. Once the 16-bit CRC value from the object file and the device are
available, CPROGPPCZ compares them. An error is thrown if the two values do
not match.
Alternatively, the “VM ;Verify Module” command can be used to perform a byte
by byte verification between the chosen object file and the device. Typically,
the VM command will take longer to perform than VC command since CPROGPPCZ has
to read the contents of FLASH of the device byte by byte. There are also two
other commands that can be used for verification. The “SC ;Show Module CRC”
instructs CPROGPPCZ to load code into the RAM of the device and instruct the
device to calculate a 16-bit CRC value from the contents of the entire FLASH
of the device, which includes blank regions. Once the 16-bit CRC value has
been calculated, CPROGPPCZ will display the value in the status window. The
“VV ;Verify Module CRC to Value” command is similar to the “SC” command. The
difference is that instead of displaying the calculated 16-bit CRC value,
CPROGPPCZ will compare the calculated value against a 16-bit CRC value given
by the user.
DOS Error Returns
DOS error returns are provided so they may be tested in .BAT files. The error codes used are:
0 – Program completed with no errors.
1 – Cancelled by user.
2 – Error reading S record file.
3 – Verify error.
4 – Verify cancelled by user.
5 – S record file is not selected.
6 – Starting address is not in module.
7 – Ending address is not in module or is less than starting address.
8 – Unable to open file for uploading.
9 – File write error during upload.
10 – Upload cancelled by user.
11 – Error opening .PCP file.
12 – Error reading .PCP file.
13 – Device did not initialize.
14 – Error loading .PCP file.
15 – Error enabling module just selected.
16 – Specified S record file not found.
17 – Insufficient buffer space specified by .PCP to hold a file S-record.
18 – Error during programming.
19 – Start address does not point into module.
20 – Error during last byte programming.
21 – Programming address no longer in module.
22 – Start address is not on an aligned word boundary.
23 – Error during last word programming.
24 – Module could not be erased.
25 – Module word not erased.
26 – Selected .PCP file does not implement byte checking.
27 – Module byte not erased.
28 – Word erase starting address must be even.
29 – Word erase ending address must be even.
30 – User parameter is not in the range.
31 – Error during .PCP specified function.
32 – Specified port is not available or error opening port.
33 – Command is inactive for this .PCP file.
34 – Cannot enter background mode. Check connections.
35 – Not able to access processor. Try a software reset.
36 – Invalid .PCP file.
37 – Not able to access processor RAM. Try a software reset.
38 – Initialization cancelled by user.
39 – Error converting hexadecimal command number.
40 – Configuration file not specified and file prog.cfg does not exist.
41 – .PCP file does not exist.
42 – Error in io_delay number on command line.
43 – Invalid command line parameter.
44 – Error specifying decimal delay in milliseconds.
47 – Error in script file.
49 – Cable not detected
50 – S-Record file does not contain valid data.
51 – Checksum Verification failure – S-record data does not match MCU memory.
52 – Sorting must be enabled to verify flash checksum.
53 – S-Records not all in range of module. (see “v” command line parameter)
54 – Error detected in settings on command line for port/interface
60 – Error calculating device CRC value
61 – Error – Device CRC does not match value given
70 – Error – CPROG is already running
71 – Error – Must specify both the INTERFACE and PORT on the command line
72 – The selected target processor is not supported by the current hardware
interface.
Example Programming Script File
The programming script file should be a pure ASCII file with one command per
line.
This is the CFG file in the previous examples.
An example is:
CM
C:\PEMICRO\Freescale_MPC565_1x32x128k_UC3F_B_512k_Memory_Blk.PCP ;Choose Flash
Module
EM | ;Erase the module |
---|---|
BM | ;Blank Check the module |
SS C:\PEMICRO\TEST.S19 | ;Specify the S19 to use |
PM | ;Program the module with the S19 |
VM | ;Verify the module again |
Note: The path names of files that are relative to the CPROG executable can also be used.
Using Command-Line Parameters in a Script
A command-line parameter in the form of /PARAMn=s can be used to insert text
into the script file in place of special tags. This can be used to replace any
part of the script
including programming commands, filenames, and parameters. Valid values of n
are 0..9. s is a string which will replace any occurrence of /PARAMn in the
script file.
As an example, the following generic script could be used for programming with
exactly the same functionality of the example script in Section 7 – Example
Programming Script File:
CM /PARAM1 | ;Choose Flash Module |
---|---|
EM | ;Erase the module |
BM | ;Blank Check the module |
SS /PARAM2 | ;Specify the S19 to use |
PM | ;Program the module with the S19 |
/PARAM3 | ;Verify the module again |
The following parameters would be added to the CPROG command line:
“/ PARAM1=C:\PEMICRO\Freescale_MPC565_1x32x128k_UC3F_B_512k_Memory_B lk.PCP
4000″ /PARAM2=C:\PEMICRO\TEST.S19 /PARAM3=VM
NOTE: Since the /PARAM1 parameter has a space in its value, the entire
parameter needs to be enclosed in double quotations. This indicates to Windows
that it is a single parameter. In this instance, a base address of 0x4000 is
included on the Choose Module line in the script, therefore /PARAM1 must be
specified on the command line like this:
“/PARAM1=C:\PEMICRO\Freescale_MPC565_1x32x128k_UC3F_B_512k_Memory_Blk.PCP
4000″ So the complete example command line would be (note that this is
continuous; no line breaks):
C:\PEMICRO\CPROGPPCZ INTERFACE=CYCLONE PORT=USB1 BDM_SPEED 1
C:\PROJECT\GENERIC.CFG “/PARAM1=C:\PEMICRO\FreescaleMPC565
1x32x128k_UC3F_B_512k_Memory_Blk.PCP 4000”
/PARAM2=C:\PEMICRO\TEST.S19 /PARAM3=VM
Sample Batch File
Here is an example of calling the command-line programmer and testing its
error code
return in a simple batch file. Sample batch files are given for both Windows
95/98/XP and Windows 2000/NT/XP/Vista/7/8/10.
Windows NT/2000/Vista/7/8/10:
C:\PROJECT\CPROGPPCZ C:\PROJECT\ENGINE.CFG
INTERFACE=USBMULTILINK PORT=USB1
if errorlevel 1 goto bad goto good :bad
ECHO BAD BAD BAD BAD BAD BAD BAD BAD :good
ECHO done
Windows 95/98/ME/XP:
START /W C:\PROJECT\CPROGPPCZ C:\PROJECT\ENGINE.CFG
INTERFACE=USBMULTILINK PORT=USB1
if errorlevel 1 goto bad
goto good :bad
ECHO BAD BAD BAD BAD BAD BAD BAD BAD :good
ECHO done
Note: The path names of files that are relative to the CPROG executable
can also be used.
Information
For more information on CPROGPPCZ and PROGPPCZ please contact us:
P&E Microcomputer Systems, Inc.| VOICE:
617-923-0053
---|---
98 Galen St.| FAX: 617-923-0808
Watertown, MA 02472-4502
USA| WEB: http://www.pemicro.com
To view our entire library of.PCP modules, go to the Support page of PEmicro’s website at www.pemicro.com/support.
References
- PEmicro - 40+ years innovating in the embedded systems space. Flash Programmers, Cloud-based, Automated, Gang Programmers, and more...
- PEmicro | Experts in Embedded tools for Flash Programming and Development
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>