CEM DT-8806H No-Contact Forehead Infrared Thermometer Operating Instruction
- June 10, 2024
- CEM
Table of Contents
- CEM DT-8806H No-Contact Forehead Infrared Thermometer
- Description
- General Description
- Safety Information
- Features
- Intended Use
- Configuration
- Indicator
- Description Of Symbols
- Technical Specifications
- Calibration Instructions
- Use
- Measuring Operation
- Maintenance And Cleaning
- Troubleshooting
- EMC Statement
- Frequently Asked Questions
- Video – Product Overview
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CEM DT-8806H No-Contact Forehead Infrared Thermometer
Description
The sensitive sensor and cutting-edge technology in this thermometer are designed to give accurate readings in under a second. A safe and hygienic experience with less chance of cross-contamination is provided through non- contact design. Results from the thermometer at reading distances of 2 to 5 inches from the target surface will be displayed. Adults, children, and elders of all ages can use this digital thermometer. It can read ambient room temperature, the temperatures of solids and liquids, in addition to measuring body temperature. features a digital LCD display that is sufficiently bright to be used in poorly lit spaces. features for automatic shutdown to maximize power savings. suited to a variety of applications. Excellent for usage by families, lodging facilities, schools, medical facilities, companies, restaurants, border crossing points for customs, railway stations, and airports.
General Description
- The non-Contact Forehead IR Thermometer is specially designed to take the body temperature of a person regardless of room temperature.
- Depending on various skin types and thicknesses, there may be temperature differences.
Safety Information
- This device must only be used for the purposes described in this instruction manual.
- This device must only be used in an ambient temperature range between 10 and 40°C.
- Do not expose this thermometer to electric shocks.
- Do not expose this thermometer to extreme temperature conditions of >50°C or <0°C.
- Do not use the device in relative humidity higher than 85%.
- Do not use the device near large electromagnetic fields such as found with cordless or cell phones.
- Keep the device away from water and heat. including direct sunlight.
- Do not drop or knock the device, and do not use if damaged.
- It may affect the accuracy of measurements when the forehead is covered by hair, perspiration, a cap, or a scarf.
- Keep the Measuring distance as 5-15cm (2-5.9inl.
- When the body infrared thermometer should be left in that room for 15 to 20 minutes before use.
- It may affect the accuracy of measurements when the forehead is covered by perspiration or other factors, please take the temperature behind the ear lobe.
- Clean the glass with a cotton bud lightly moistened with 70% alcohol.
Importance:
- Before taking the temperature make sure to remove hair and perspiration from the forehead.
- Selecting “Body” Mode to measure the body temperature; Selecting “Surface” Mode to measure the surface temperature.
- Use of this thermometer is not intended as a substitute to consultation with your physician.
- Should a problem occur with your device, please contact your retailer, do not attempt to repair the device yourself.
- According to EMC standards, medical electronic products should be maintained specially.
Features
- Precise non-contact measurements
- User selectable °C or °F
- Selectable Body and Surface temp
- Set Alarm value
- Memorization of the last 32 measurements
- Automatic Data Hold & Auto power off
- Automatic selection range and Display Resolution 0.1 °C[0.1 °FJ
- Backlight LCD display
Intended Use
- The non-Contact Forehead IR Thermometer is designed for body surface and forehead temperature measurement for infants and adults without contact to human body.
- Non-Contact Forehead IR Thermometer can also be used to measure the temperature of a baby- bottle or bath, or room temperature [by using the Surface Temp function].
Normal Temperatures According To Measurement Method
Note: The temperature of the human body varies throughout the day, It can also be influenced by numerous external factors: age, sex, type and thickness of skin.
Normal Temperatures According To Age
Age | Temp °C | Temp 0 f |
---|---|---|
0-2 years | 36.4 to 38.0 | 97.5 to 100.4 |
3-10 years | 36.1 to 37.8 | 97.0 to 100.0 |
11-65 years | 35.9 to 37.6 | 96.6 to 99.7 |
>65 years | 35.8 to 37.5 | 96.4 to 99.5 |
Configuration
- IR Sensor
- Measurement Trigger
- LCD Display
- Mode Selection
- Down Button
- Up Button
- Mode Button
- Battery Cover
Indicator
- Surface Mode Symbol
- Body Mode Symbol
- Digital Readout
- The Order Number
- Buzzer Symbol
- Temperature °C [Celsius) Scale
- Temperature °F [Fahrenheit) Scale
- Battery Symbol
- Save Data Readout
Description Of Symbols
Technical Specifications
Normal Conditions Of Use
- Display Resolution 0.1°C (0.1°F)
- Operating Temperature 10 to 40°C (50 to 104° F)
- Storage Temperature 0 to 50°C (32 to 122° F)
- Humidity Rate < 85%
- Power DC 3V (2 x “AA” batteries)
- Size (L x W x H) 149 x 77x 43mm / 5. 9 x 3 x 1.7in
- Weight Gross 400g / Net 172g
Measuring Range
- In Body Temp. Mode 32.0 to 42.5°C (89.6 to 108.5° F)
- In Surface Temp. Mode 0 to 60°C (32 to 140° F)
- Accuracy ±0.3°C (0.54° F)
- Measuring Distance 5-15cm (2-5.9in)
- Automatic Shutdown 7 sec.
Non-Contact Body Infrared Thermometer Precision
- 32 to 35.9°C / 89.6 to 96.6°F ±0.3°C / 0.5° F
- 36 to 39°C / 96.8 to 102.2°F ±0.2°C / 0.4° F
- 39 to 42.5 C / 102.2 to 108.5°F ±0.3°C / 0.5° F
According to ASTM Standard E1965-98
Calibration Instructions
- For stable and reliable results, The thermometer provides a user-correction function, the operation of the method is as follows:
- 1st Step: Take the temperature of a person using a conventional thermometer; you will get 37.5°C (99.5° F) for instance.
- 2nd Step: Take the temperature of the same person using the Non-contact Body Infrared Thermometer keeping the 5 to 15cm [2 to 5. 9inl distance between the thermometer and the forehead [Take care to remove any obstacle which could alter the measurement [hair, perspiration…]. if you get 37.5°C [99.5° Fl. the Non-contact Body Infrared Thermometer is properly set and ready for use.
- If you get a lower temperature, 36.4°C [97.4° F] for example, your difference is 1.1°c [2.2°F], You should adjust the temperature on the Non-contact Body Infrared Thermometer and add the difference, i.e. 1.1 °C [2.2° F].
- To do it. Press the “MODE'” Button for 2 seconds, the screen displays F1. Press “the “MODE”‘ Button again until you get F3, and press ··up– Button in order to add the difference [in our example, 1.1 °C-2.2° F].
- 3rd Step: To check, take the temperature again using the Non-contact Body Infrared Thermometer.
Use
-
Install battery.
-
For the first use or when inserting new batteries wait 10 minutes for the warm-up of the apparatus and when inserting the new batteries.
-
If the device is not used for a long time, once you turn it on again, the device will test the room temperature first and will delay turning on for one or two seconds.
-
Aim towards the forehead [see the diagram below for the positioning]. from a distance of 5cm[2in), press the measuring key, and the temperature is displayed immediately, Make sure there is no hair, perspiration, cosmetics, or cap covered on the forehead.
-
When the room temperature is a significant difference, or there is perspiration on the forehead, You can take the temperature behind the ear lobe, Making sure there is no hair, perspiration, cosmetic, or cap covered.
Measuring Operation
Choosing The Temperature Unit-Fl Function
- Press the “MODE” Button for 2 seconds, and the screen displays: Fl.
- Select “DOWN” for degrees Celsius, and “UP” for degrees Fahrenheit.
Alarme Setup-F2 Menu
- Press the “MODE” Button for 2 seconds, and the screen displays: Fl.
- Press twice “MODE” Button to get F2.
- Select “UP” to increase the threshold by 0.1 °C [0.1 °Fl. “DOWN” to reduce it by 0.1 °C [0.1 °F). Note: The alarm threshold default value is 38°C [100.4° F).
Total Difference-F3 Menu
- To adjust the total variation of your Non-contact Body Infrared Thermometer.
- Press the “MODE” Button for 2 seconds, and the screen displays: Fl.
- Press the “MODE” Button two times to get F3.
- Select “UP” to increase the difference by 0.1 °C [0.1 ° Fl. “DOWN” to reduce it by 0.1°C [0.1° F).
- In the cases of seasonal or environmental changes, verification and adjustment should be carried out.
- Note: This function is only effective Body.
Buzzer ON/OFF-F4(F3) Menu
- Press the “MODE” Button for 2 seconds, and the screen displays: Fl.
- Press three [two) times “MODE” Button to get F4 (F3).
- Select “UP” to open the buzzer [a sound icon “ ” is displayed on the LCD screen). Press “DOWN” to stop it [the icon disappears).
Exiting The Setting Mode
Press the “MODE” Button until the screen turns off.
- The Non-contact Body Infrared Thermometer is specially designed to take the body temperature of a human being, for this use the Body mode.
- Measurement range for Body mode: 32 to 42.5°C [89.6 to 108.5° Fl.
- You can also use the Non-contact Body Infrared Thermometer to measure the temperature of an area or an object. a food, a liquid, or a room temperature, for this, use the Surface mode.
- Measurement range for Surface mode: 0 to 60°C [32 to 140° F].
Important:
- The area temperature differs from the internal body temperature, to obtain the internal temperature always use the Body mode.
- Please make sure to select the Body mode for an internal temperature reading and the Surface mode for an external area reading [bottle, bath, room…].
Data Memory
- Data memory automatically after temperature measurements, which will display at the right corner of the LCD.
- Press the “UP” or “DOWN” Button to display the last temperature measurement.
- Under the condition of power oft, press the “UP” and “DOWN” Buttons together for two seconds, to display the last temperature measurement.
- In this mode, if change the order number to O and press the “MODE” Button, then delete all memory data.
Changing The Batteries
- Display: when the LCD screen displays “ ” the battery is used.
- Operation: Open the lid and change the batteries, taking great care with the correct positioning, A mistake with this could cause damage to the apparatus and compromise the guarantee of your Non-contact Body Infrared Thermometer.
- Never use rechargeable batteries.
- Use only batteries for single usage.
- Remove the battery from the instrument if it is not required for extended periods of time in order to avoid damage to the thermometer resulting from a leaking battery.
Longevity Use
The Non-contact Body Infrared Thermometer was conceived for intense and professional use, its longevity is guaranteed for 40000 takings.
Advice
- The protective glass over the lens is the most important and fragile part of the thermometer, please take great care of it.
- Do not recharge non-rechargeable batteries, and do not throw them in a fire.
- Do not expose the thermometer to sunlight or water.
Maintenance And Cleaning
- The Infrared Sensor is the most precise part. must be protected carefully.
- Clean the device with a cotton bud lightly moistened with 70% alcohol.
- Do not clean the device with corrosive detergent.
- Keep the device away from water or other liquid.
- Store the device in a dry environment, and keep it away from dust and direct sunlight.
Troubleshooting
If you happen to have one of the following problems while using your non- contact forehead IR thermometer please refer to this breakdown service guide to help resolve the problem, if the problem persists please contact our customer service.
The Screen Displays The Body Temperature Inferior To 32°C (89.6°F)
If you’re on the Surface mode the 32°C[89.6° F] temperature displayed is
showing the external temperature that your body releases.
The Screen Displays The Message “HI”
- When using the Non-contact Body Infrared Thermometer, the message HI can show on the screen.
- The analysis is above the measurement range selected, either superior to 42.5°C (108.5°F) in Body mode or superior to 60°C (140° F) in Surface mode.
The screen displays the message “LO”
- When using the Non-contact Body Infrared Thermometer, the message Lo can show on the screen.
- The temperature analyzed is under the measuring range selected, either less than 32°C (89.6°F) in Body mode or less than 0°C (32° F) in Surface mode.
This message displays in various cases-Please find below a list of the main cases.
Reasons for “LO” or “HI” message display | Advice |
---|
Temperature reading hampered by the hair,
perspiration…
| Make sure that there is no obstruction prior to
taking a temperature.
Temperature is hampered by an air flux.| Make sure there is no air flux as
this could interfere with the infrared system.
The measuring distance is too far.| Please respect the measuring distance
[between 5 to 15cm/ 2 to 5.9 in)
From high/low-temperature conditions to room temperature| Waiting for 10
minutes before taking the body temperature
This Appliance Conforms To The Following Standards:
- IS080601-2-56 and ASTM E1965-98
- EN 60601-1: Medical electrical equipment Part 1: General requirements for safety [IEC:60601-1)
- EN60601-1-11: Medical electrical equipment-Part 1-11: General requirements for basic safety and essential performance-Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment[IEC60601-1-11)
EMC Statement
This device has been tested and homologated in accordance with EN60601-1-2 for EMC. This does not guarantee in any way that the device will not be affected by electromagnetic interference. Avoid using the device in a highly electromagnetic environment.
The MEDICAL □ELECTRICAL EQUIPMENT needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPANYING DOCUMENTS.
- The manufacturer reserves the right to alter the specifications of the product without prior notification.
- The manufacturer allows himself the right to modify without a preliminary opinion the technical specifications of the product.
Frequently Asked Questions
How does the CEM DT-8806H forehead thermometer work?****
The CEM DT-8806H forehead thermometer uses infrared technology to measure the temperature of the forehead accurately. It detects the heat emitted from the temporal artery and converts it into a temperature reading.
Is the CEM DT-8806H thermometer suitable for all ages?****
Yes, the CEM DT-8806H forehead thermometer is suitable for individuals of all ages, including infants, children, and adults.
Can the CEM DT-8806H thermometer be used to measure other body temperatures?****
While the CEM DT-8806H is primarily designed for forehead temperature measurement, it can also measure the temperature of other surfaces and objects, such as liquids and ambient room temperature.
Does the CEM DT-8806H require direct contact with the forehead?****
No, the CEM DT-8806H is a non-contact thermometer, meaning it does not require direct contact with the forehead. It can measure the temperature from a distance of approximately 1-3 centimeters (0.4-1.2 inches).
How accurate is the CEM DT-8806H forehead thermometer?****
The CEM DT-8806H forehead thermometer is designed to provide accurate temperature readings. However, it’s important to follow the manufacturer’s instructions carefully for consistent and accurate results.
Can the CEM DT-8806H be used to measure body temperature in different environments?****
The CEM DT-8806H forehead thermometer is suitable for use in various environments, including home, clinics, hospitals, and workplaces. However, extreme ambient temperatures or exposure to direct sunlight may affect the accuracy of the readings.
Does the CEM DT-8806H have a memory function to store temperature readings?****
Yes, the CEM DT-8806H forehead thermometer is equipped with a memory function that can store multiple temperature readings. This feature allows you to track temperature trends over time.
Can the CEM DT-8806H thermometer be used for fever detection?****
Yes, the CEM DT-8806H thermometer can be used as a tool for initial fever detection. However, it’s important to note that it should not replace a medical diagnosis, and if you suspect a fever, it’s recommended to consult a healthcare professional.
How do I clean the CEM DT-8806H thermometer?****
To clean the CEM DT-8806H thermometer, use a soft, dry cloth or cotton swab to wipe the surface of the device. Avoid using water or chemical cleaners on the device.
Is the CEM DT-8806H thermometer FDA approved?****
The CEM DT-8806H thermometer is not specifically mentioned as FDA-approved. It’s always recommended to check the product packaging, and documentation, or consult the manufacturer for any certifications or approvals.
Video – Product Overview
Download The PDF Link:CEM DT-8806H No-Contact Forehead Infrared Thermometer Operating Instruction