Autovent Systems AV-CP6 Series Control Panel Installation Guide

June 10, 2024
Autovent Systems

Autovent Systems logo Wiring and Installation Guide
FORM: D8052

AV-CP6 Series Control Panel Instructions

Model Power(W) Channel Vin(VAC) Vout(VDC) Frequency Size(mm)
AV-CP611-10A 240 1 110/230 24 433.92MHz 27222873mm
AV CP611-20A 480 1 110/230 24 433.92MHz 27222873mm
AV-CP621-40A 960 1 110/230 24 433.92MHz 2922S887mm

Autovent Systems AV-CP6 Series Control Panel - Fig 2

LED/KEY Color Status Function
L1 / K1 Blue On/Off AC power, Reset
L2 / K2 Green On/Off/Flash Open
L3 / K3 Red On/Off Stop
L4 / K4 Yellow On/Off Close

AV-CP6 Series Control Panel Wiring

Autovent Systems AV-CP6 Series Control Panel - Fig 3

Power Control Relay Wiring

Autovent Systems AV-CP6 Series Control Panel - Fig 4Autovent Systems AV-CP6 Series Control Panel - Fig
5The wiring method in Figure 3 is commonly used in applications where 4 or less openers will be installed with less than 40’ of total wiring run. 14 gauge wire can be used in this scenario. Figure 4 divides the power to the openers into multiple lines. It is recommended for applications of 4 or more openers and/or wiring runs over 40’. 14 gauge wire can still be used with this method for up to 8 openers with a wiring run of 40’ or less (per line). 12 gauge wire should be used for longer runs.

AV-RT111 Remote Control Instructions

Pairing Remote with Control Panel

  1. Power the control panel on or press reset if already on. Press and hold the STOP button for 5 seconds.
  2. Press UP on the remote for 15 seconds. The LED on the remote should flash 3 times and turn off during this process.

Remove Pairing with Control Panel

  1. Power the control panel on or press reset if already on. Press and hold the STOP button for 5 seconds.
  2. Press DOWN on the remote for 15 seconds. The LED on the remote should flash 3 times and turn off during this process.

AV-SCE Vent Opener Instructions

  1. Actuator
  2. Hexagonal head screw
  3. Fixed Bracket
  4. Fixed Holder
  5. Pin
  6. M5 self tapping screw

Opener Specifications

Voltage: 24V DC
Max Current: 1 amp
Max Lifting Weight: 55 lbs.
Arm Travel Distance: 12″
Time to Open / Close: — 35 seconds
Operating Temp Range: -4F to 149F Autovent Systems AV-CP6 Series Control
Panel - Fig 9

  1. Attach the fixed brackets to the actuator. Place the opener on the frame where the arm will attach as close the center of the vent as possible, and mark the location of both brackets.
  2. Unscrew the fixed brackets, and place them where marked on the frame (mounting position shown is for Cross Country greenhouses and optimal position may vary for other brands).
  3. Use the provided Hex head screws starting with the center hole. They are self-tapping so no pre-drilling is needed. For Cross Country greenhouses the top hole is not used because the screw will damage the covering / glazing on most models.
  4. Mount the actuator to the fixed brackets, and place the fixed arm holder on the vent where the arm will make contact when extended. Use the Phillips head screws to attach the fixed arm holder to the vent frame. Press open on the control panel or remote to move the head of the arm in position to secure it to the holder with the attached bolt.
  5. Fully open and close the vent to make sure it operates smoothly. Repeat this process for the rest of the openers.

Autovent Systems AV-CP6 Series Control Panel - Fig 10

Typical Control Panel Installation

Autovent Systems AV-CP6 Series Control Panel - Fig 11

Autovent Systems logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Autovent Systems User Manuals

Related Manuals