TEKBOX TBCG3-CN Comb Generator User Manual
- June 10, 2024
- TEKBOX
Table of Contents
TBCG3-CN
Comb Generator
User Manual
Introduction
The TBCG3-CN produces a comb spectrum with approximately 8 dB flatness in the frequency range up to 1.5 GHz and has a 50 Ohm output with a female N- connector. The housing is milled from solid aluminum. A ¼” – 20 UNC thread in the comb panel accepts standard tripod bolts.
Specification
Specified bandwidth: 1.5 GHz
Flatness of the comb spectrum: 8 dB typically
Output impedance: 50 Ohm
Output power: 66 dBµV @ 10 MHz f comb; decreasing 6 dB with every fcomb/2
Amplitude stability: < 0.2 dB; <0.1 dB after 15 minutes
Aging: < 0.5 dB over 12 months
Output connector: N-female
Selectable, fixed comb frequencies: 100 kHz, 500 kHz, 1 MHz, 5 MHz, 10 MHz
Frequency stability: 50 ppm
External excitation input: 5 kHz – 300 MHz @ square input signal; 3.3 Vpp max
100 kHz – 300 MHz @ sinus input signal; 3.3 Vpp max
Input impedance: 50 Ohm
Input connector: SMA-female
Current consumption: 70 mA
Indicators: Power On LED, Low Battery LED
Power supply: 4 x AA NiMH (e.g. Varta Mignon 2700, not supplied)
Charger: external; Ansmann ACS110
Operation time: battery capacity / 70 mA
Temperature range: -20°C to +45 °C
Housing diameter: 180 mm
Housing height: 60 mm
Weight: 1250 g
3 Spectrum plots, fcomb: 10 MHz, 5 MHz, 1 MHz, 500 kHz, 100 kHz
TBCG3-CN Comb Generator
TBCG3-CN Comb Generator
TBCG3-CN Comb Generator
TBCG3-CN Comb Generator
Spectrum plots, external frequency input
TBCG3-CN Comb Generator
Application
Checking the sanity of a LISN or conducted emission measurement setup.
There is no need to swap the N-connectors of the LISN adapter cable to switch
between LISN channels, when utilizing a TBRFPS1 power splitter:
Warning:
Never connect the comb generator or the comb generator adapter cable to a
powered LISN to avoid potentially lethal electric shock. Before connecting the
comb generator adapter cable into the DUT / EUT socket, always unhook the
mains connector on the back of the LISN.
Never plug the comb generator adapter cord into a power outlet to avoid
potentially lethal electric shock.
Inserting/replacing batteries
Loosen the SMA-connector nut a few turns. Remove the six screws at the bottom
of the comb generator housing, lift it, and insert four AA rechargable 1.2V
NiMH batteries. Both the battery compartment and the PCB indicate the
polarity.
Reattach the bottom cover, then tighten the screws and the SMA-connector nut.
Ordering Information
Part Number | Description |
---|---|
TBCG3-CN-EU | Comb generator, Ansmann ACS110 charger, LISN adapter cable with |
Schuko connector
TBCG3-CN-UK| Comb generator, Ansmann ACS110 charger, LISN adapter cable with
UK connector
TBCG3-CN-US| Comb generator, Ansmann ACS110 charger, LISN adapter cable with
US connector
TBCG3-CN-AU| Comb generator, Ansmann ACS110 charger, LISN adapter cable with
Australian connector
TBLA-3P-16A| BNC adapter for 3 Phase LISN TBL5032-16A EUT socket
TBLA-3P-32A| BNC adapter for 3 Phase LISN TBL5032-32A EUT socket
TBLA-PH1| BNC adapter for TBL5016-1 or TBL0550 EUT/SOURCE socket
TBLA-PH2| BNC adapter for TBL50100 or TBL05100 EUT/SOURCE socket
TBRFPS1| Power splitter
History
Version | Date | Author | Changes |
---|---|---|---|
V 1.0 | 4.2.2023 | Mayerhofer | Creation |
www.tekbox.com
TekBox Digital Solutions Vietnam Pte. Ltd.
Factory 4, F4, Lot I-3B-1, Saigon Hi-Tech Park, Tan Phu Ward, District 9, Ho
Chi Minh City, Vietnam