Aquamaxx 6671-0 Shower system shower column Splash Instruction Manual
- June 11, 2024
- AQUAMAXX
Table of Contents
- Aquamaxx 6671-0 Shower system shower column Splash
- Product Information
- Product Usage Instructions
- Checking the product
- Technical Construction Requirements
- Mounting
- CARE INSTRUCTIONS
- Connection Dimensions
- Product Overview
- Tools Needed
- Installation
- FAQs
- IMPORTANT INFORMATION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aquamaxx 6671-0 Shower system shower column Splash
Product Information
- Product Name: Unknown
- Model Number: 6671-1
- Date: 10/18
Checking the Product
The product should be checked for any damage before installation.
Technical Construction Requirements
The product is intended for connection to a pressurized hot water supply
and needs to be taken care of sufficient performance of at least 24kW when
used in conjunction with water heaters. The product is not suitable for use
with non-pressurized storage (open water systems).
Technical Data
- Minimum flow pressure: 1 bar
- Maximum operating pressure: 5 bar
- Operating pressure greater than 5 bar requires a pressure reducer
- Maximum flow temperature:
- Recommended flow temperature:
- Flow rate at 3 bar pressure at hand/and shower head (standard version): 9 l/min
Mounting Instructions
Flush before and rinse after installation according to EN 806 (run at the
main tap for about 3 min. open water). Connection to wall plates with G1/2,
hole centers 150mm, hot water left, cold water right.
Care Instructions
The different surfaces of today’s faucets such as chrome, glass, or plastic
require meticulous care and a cleaning regime. Damage caused by inadequate or
improper cleaning is not covered by the warranty conditions. Plating can
enhance the damage.
Product Usage Instructions
- Check the product for any damage before installation.
- Ensure that the product is connected to a pressurized hot water supply and that the water heater has sufficient performance of at least 24kW.
- Do not use the product with non-pressurized storage (open water systems).
- Ensure that the flow pressure is at least 1 bar and the maximum operating pressure is 5 bar. If the operating pressure is greater than 5 bar, a pressure reducer is required.
- Ensure that the maximum flow temperature and recommended flow temperature are within the specified limits.
- Mount the product according to the instructions provided, ensuring that it is connected to wall plates with G1/2, hole centers 150mm, hot water left, cold water right.
- Flush before and rinse after installation according to EN 806 (run at the main tap for about 3 min. open water)
- Follow the care instructions provided to ensure that the product remains in good condition.
Dear customer,
Thank you for purchasing this product. We would like to ask you to read the
following notes and tips so that you can enjoy this product for a long time.
Checking the product
Check your Shower-Set prior to installation for transport damage or other damage that may have occurred. After the installation of the product, no claims for damages will be accepted under the warranty. Chrome surfaces have certain manufacturing characteristics. These may be hairline scratches or irregularities in the metal. There should be no cause for concern if you cannot see any such imperfections when standing at a distance of 1,5 meters from the object and under normal lighting conditions. The overall impressions is conclusive.
Technical Construction Requirements
Scope of use:
- This product is intended for connection to a pressurized hot water supply. When used in conjunction with water heaters it needs to be taken care of sufficient performance of at least 24kW.
- The product is not suitable for use with non-pressurized storage (open water systems).
- The product is factory-adjusted to a flow pressure of 3 bar with a flow temperature of 60°C.
- For different installation conditions, adjusting the thermostat may be required.
- Refer to the Maintenance section!
Technical data
- min. flow pressure: 1 bar
- max. operating pressure: 5 bar
- Operating pressure greater than 5 bar = pressure reducer required.
- max. flow temperature: 80°C
- rec. flow temperature: 60°C
- The flow temperature must be at least 5°C higher than the mixed water temperature.
- Flow rate at 3 bar pressure at hand / and shower head (standard version): 9 l/min
- The valve must be drained separately in case of frost. Emptying of the water pipe network is not sufficient.
Mounting
- Flush before and rinse after installation according to EN 806 (run at the main tap for about 3 min. open water).
- Connection to wall plates with G1/2, hole centers 150mm, hot water left, cold water right.
CARE INSTRUCTIONS
The different surfaces of today’s faucets such as chrome, glass, or plastic require meticulous care and a cleaning regime.
The following rules apply:
- The faucets should be cleaned with a damp cloth and dried with a soft one daily to prevent the build-up of limescale.
- We recommend using a neutral soap.
- Do not spray the cleaning agent directly on the product, but apply with a cloth (this prevents the accumulation of detergent).
- Adhere to the respective manufacturer’s instructions for cleaning.
- Remove the residue of the cleaning agent with cold clean water.
- Remove the residue of shower gels and shampoos after every use to prevent damage.
- According to EN 806, the pipes need to be rinsed at least 3 minutes before installation.
Damage caused by inadequate or improper cleaning is not covered by the warranty conditions.
Caution:
Any cleaner containing acetic acid, hydrochloric acid, chlorine bleach, or
formic acid can cause considerable damage!
- Do not use abrasive cleaning agents (scouring pads, etc.).
- No high-temperature cleaning agents (steam cleaners).
- Do not use or store chemical cleaners near the fittings. The release of chemicals can damage the fittings.
- Damaged surfaces facilitate the penetration and infiltration of detergents under the chrome plating which will enhance the damage.
Connection Dimensions
All dimensions are subject to a tolerance of ± 5 mm.
Dimensions partly depend on the position of the S-connectors and because of
manufacturing reasons, may vary slightly.
Product Overview
When ordering spare parts, please specify the item on the order form.
Tools Needed
Installation
Change the thermostatic cartridge
Turn off the water!
Non-return valve maintenance
Turn off the water!
Installation in the reverse order
Change the diverter
Turn off the water!
Installation in the reverse order
FAQs
Problem | Reason | Possible solutio | Notice |
---|---|---|---|
Hot and cold water adjustment possible only | Hot and cold water | ||
interconverted | Connecting the water supply in |
reverse
| No reverse catridge existing
Minor water amount/Ceasing water amount| Mistake in supply| Check hot and cold
water supply| Radiator working? Water supply running?
Polluted sieve| Clean filter at s-connection| Deinstall entire thermostat
Polluted catridge| Cleaning catridge| see page 16
Polluted non-return valve| Cleaning non-return valve in the entrance of
cartridge and checking the function| deinstall entire thermostat. Shank in RFV
has to run smoothly and adjust back to initial position by the spring
Polluted components connected in
series
| Cleaning nozzle/shower head|
Fitting flowing incessant| Defect switch| Exchanging the entire switch| Check
the housing for possible dirt, clean if necessary see page 18
Hot water is being pressed into the cold water pipe/or reversed| Cross flow
caused by not closing non retun valves| Cleaning non-return valve in the
entrance of cartridge and checking the function| deinstall entire thermostat.
Shank in RFV has to run smoothly and adjust back to initial position by the
spring
Twisting glider| Loose screwing| Tightening the screwing|
Height adjustment impossible| Defect glider| Exchanging the glider|
Top wall mounting does
not hold
| Fixing plate twisted by 180°| Fit fixing plate correctly|
Temperature setting impossible or tight| Blocked slider in cartridge due to
residue| Tilting the temperature knob/descaling the cartridge| Tilt the knob
regulary to prevent residue
Defect catridge| Exchanging the catridge| see page 16
Mixed water temperature can not be reached| Hot water temperature too low|
Increasign the hot water temperature| Assure that the hot water temperature is
at least 5°C higher than the desired mixed
water temperature
Blocked slider in cartridge due to
residue
| Tilting the temperature
knob/descaling the cartridge
| Tilt the knob regulary to prevent residue
Water supply not according to
standard conditions
| Adjusting the cartridge|
Cross flow caused by not closing non
retun valves
| Cleaning the non-return valve| see page 17
Flow heater/pumping station not
adequately dimensioned
| Schaltstufen variieren, ggf.
Durchflussmenge anpassen
|
Shifting tight/stuck| Diverter out of grease| Cleaning and greasing switch /
exchanging
| Check the housing for possible dirt, clean if
necessary
Water flows out of both outflows simultaneously| Dirt in Diverter shank| Clean
diverter shank| Check the housing for possible dirt, clean if necessary see
page 18
Defect switch| Changing entire stop
Switch not on stop| Tilting switch on stop|
Dripping head shower| Shower head not horizontal/not
screwed tight
| adjust horizontal / screw tight|
Dripping hand shower| Switch not on stop| Tilting switch on stop|
IMPORTANT INFORMATION
Keep children away from the packaging materials. Please make sure that cardboard boxes, foils, and packets are not slipped over their heads, or parts thereof swallowed. The small parts needed for mounting, such as screws, also pose a risk of suffocation if swallowed! The mounting material is intended for solid masonry. Before starting to mount, inform yourself of suitable mounting materials for your wall. Ensure that no pipes or cables are present at the drilling point. Handle the glass panes with care. Avoid resting the glass panes on their corners, as well as placing them on an uneven surface. Use glass suction cups to transport the glass panes and use the accompanying edge protectors.
Check the received goods for possible transport damages, as no liability will
be assumed for damages to products that have already been mounted. Before
mounting, check whether the product, color, type of glass and size correlate
with your order. During mounting, please use the attached mounting
instructions as a guideline.
The warranty card, which is also enclosed, contains information regarding the
warranty terms, as well as instructions for care.
Dusch-Info
- Meerpfad 27-31 56566 Neuwied
- Tel.: 02631-8607-0
- Fax: 02631-860735