GRAYL GeoPress Filter and Purifier Bottle User Manual
- June 11, 2024
- GRaYL
Table of Contents
Filter and Purifier Bottle
User Manual
GeoPress Filter and Purifier Bottle
Active Technology:
Electro. adsorption and ultra-powdered activated carbon
8PA free materials: Yes
Sire: 2.9(73cm)x31(7.8 cm) w
Weight: 3.8 02 (108 g)
Fast Flow: 8 seconds per 24oz (5liters/minute)
Lifespan: 350 presses (250L/65 gal)
Shelf Life: Stored under proper conditions, an unopened Cartridge has a
shelf life of 10 years. After a cartridge has been used, it lasts at least 3
add’/years
REMOVES
VIRUSES ( 99.99% ] ROTOVIRUS, NOROVIRUS, HEPATITIS A
BACTERIA ( 99.9999% )
E. COLI, SALMONELLA, DYSENTERY
PROTOZOA ( 99.9% )
GIARDIA, CRYPTOSPORIDIUM, AMOEBAE
FILTERS
PARTICULATES
MICROPLASTICS, SEDIMENT, SILT
CHEMICALS
PFAS, CHLORINE, CHLOROFORM
HEAVY METALS
LEAD, ARSENIC, CHROMIUM
DRINK-MIX READY
USE ELECTROLYTES AND OTHER DRINKS IN YOUR GRAYL!
SOLD SEPARATELY
TECHNOLOGY
CARTRIDGE LIFESPAN
The lifespan of a Cartridge varies with the quality of the water sources the
clearer the better In clear wate, a Cartridge will be effective for +30cycles
(6gal/ 20) Lifespan is shortened in water containing impurities such as mud,
gilt or tannins. A peg time” reaches 2seconds (or three years have elapsed
since first use)it’s time tore place the Cartridge. Regardless of flow rate,
(artidges are effective (no waterborne pathogens pass)
350 PRESSES
250 L/65 GAL 5L/MN
ONE PRESS”
8 SEC00S
CARTRIDGE REMOVAL
REMOVAL
fuel grasp the Inner Press. Rotate the cartridge (left-loose) until it
separates from the Inner Press
CARTRIDGE INSTALLATION
INSTALLATION
Firmly grasp the Inner Press. Insert cartridge into the bottom of the Inner
Press.
CAUTION: Proper installation of cartridge prevents cross-contamination.
IMPORTANT: LOCK CARTRIDGE
Rotate cartridge (rightytighty) until you feel it CLICK and LOCK INTO PLACE.
If the cartridge is not locked, it can fall off during use.
PRECAUTIONS
FRESHWATER ONLY.
Use freshwater only (no other liquid). NO salt or brackish water.
CROSS-CONTAMINATION.
Do not expose/fill the Inner Press with untreated water, cross contamination
may occur. If this does happen, disassemble and wash GeoPressc (not Cartridge)
with soapy water and rinse thoroughly. Alternatively, thoroughly dilute
potential contaminants by pressing (and agitating) water through the GeoPress®
Cartridge 5-7 times.
SOURCING THE BEST WATER.
Always begin with the cleanest (least silty) water available. For instance,
streams are generally better than lakes and bogs (which are often have higher
levels of sediment and tannins).
CYANOBACTERIA, HIGH LEAD LEVELS, MERCURY, ETC.
Cartridges are designed to remove trace levels of chemicals and heavy metals.
The GeoPress® was NOT designed to protect against industrial disasters, coal
ash spills, very high lead levels, mercury, nuclear disasters or toxic blue-
green algae (cyanobacteria), etc. Find another water source in these
situations.
CAUTION WITH TANNINS.
Tannins are natural organic compounds that leach from decomposing vegetation
and trees and can cause Cartridges to prematurely clog. In high
concentrations, tannins are easily recognizable, as they turn water tea-
colored and form blackwater rivers. Do not use UltraPress® in water with high
tannins.
NO FREEZING.
Cartridges are not significantly degraded after one freeze/thaw cycle.
However, don’t use a cartridge after 3 or more freeze/thaw cycles. Protect
your GeoPress® in freezing temperatures by keeping it full of water and
insulate in a jacket or sleeping bag.
NO HOT (OR BOILING WATER) OR MICROWAVES.
Do not expose Cartridge to water hotter than 120F (SOC), it will harm purifier
media. Do not put the GeoPress” in the microwave.
CARE BETWEEN USES
DON’T USE SOAP ON CARTRIDGE.
Do not wash the Cartridge with soap or other cleaning agents. Soap will damage
the purifier media. You may rinse the Cartridge with clean water as needed.
PROPER CARE & STORAGE
Thoroughly dry wet Cartridge by pressing into an empty (no water) Outer Cup
and dump excess water. Remove One-Way Silicone Valve (sold separately) and
allow Cartridge to air-dry thoroughly (depending on humidity it will take 2-4
days to completely dry). Hand wash all other parts including One-Way Silicone
Valve with warm, soapy water. Reassemble unit to create airtight seal for
storage. Cartridges can last up to three years after opening if cared for
properly between uses.
WE HAVE YOU COVERED
WARRANTY
Every GRAYL is accompanied by a ten (10) year warranty covering workmanship
and materials.
TESTING STANDARDS.
Meets or exceeds the US EPA Guide Standard and Protocol for Testing
Microbiological Water Purifiers (April 1987).
QUESTIONS?
For answers to the most common questions, live chat, and product support,
please visit www.grayl.com/help
INTERNATIONAL MANUALS.
Manual: www.grayl.com/manuals
GRAYL® pledges 1% of sales to the preservation and restoration of the natural environment. 1% For The Planet is a global network of businesses, nonprofits and individuals working together for a healthy planet.
SCAN WITH YOUR PHONE
LET’S GO!
Get detailed video instruction on this product.
6.31 ST4 AV
W4209SEATTLE
WA 98119/877.293.786
© 2023 RAYL. INC. ALL RIGHTS RE SERVED
Read User Manual Online (PDF format)