OSRAM Sylvania T8 Instant Start Universal Voltage Systems Owner’s Manual

June 11, 2024
OSRAM Sylvania

OSRAM-Sylvania-LOGO

OSRAM Sylvania T8 Instant Start Universal Voltage Systems

OSRAM-Sylvania-T8-Instant-Start-Universal-Voltage-Systems-
PRODUCT

Product Information

The QTP T8 ISN is a universal voltage system from the QUICKTRONIC Professional Series that offers lamp striation control normal ballast factor. It is designed to operate with 32W T8 fluorescent lamps and can be used with 1-lamp, 2-lamp, 3-lamp, or 4-lamp setups using the corresponding QTPx32T8UNV ISNSC ballasts. The product also supports F40T8 operation with 1 lamp on 2L ballast, 2 lamps on 3L ballast, and 3 lamps on 4L ballast. Additionally, the product can operate with FB32, FB31, F25, FB24, F17, FB16, F30/SS (30W), FB30/SS (30W), FB29/SS (29W), F28/SS (28W), and F25/SS (25W) lamps.

The QUICKTRONIC Professional Series products are commonly used in OEM standard fixtures and stocked products for replacement by trade/distributors. The product is equipped with parallel circuitry that keeps the remaining lamps lit if one or more go out. It complies with the European Union Restriction of Hazardous Substances Directive (Directive EC 2002/95). The product comes with a warranty.

Product Usage Instructions

Before using the QTP T8 ISN, ensure that the product is installed in a compatible fixture and that the lamp wattage and number of lamps are within the specified range. Follow the instructions provided in the fixture manual for installation.

For 32W T8 fluorescent lamps, use the corresponding QTPx32T8UNV ISNSC ballasts based on the number of lamps required (1-lamp, 2-lamp, 3-lamp, or 4-lamp setups). For F40T8 operation, use 1 lamp on 2L ballast, 2 lamps on 3L ballast, or 3 lamps on 4L ballast.

When using the product, ensure that the line voltage is within the specified range of 120-277V. If any lamp goes out, the parallel circuitry will keep the remaining lamps lit. If the product is used in the European Union, it complies with the Restriction of Hazardous Substances Directive (Directive EC 2002/95).

If you experience any issues with the product, contact QUICKTRONIC North America at 1-877-636-5267 or email techsupport@quicktronic.com.

Lamp / Ballast Guide

32W T8 fluorescent lamps

  1. lamp QTP 1x32T8 UNV ISN SC
  2. lamp QTP 2x32T8 UNV ISN SC
  3. lamp QTP 3x32T8 UNV ISN SC
  4. lamp QTP 4x32T8 UNV ISN SC

Also operates:
FB32, FB31, F25, FB24, F17, FB16, F30/SS (30W), FB30/SS (30W), FB29/SS (29W), F28/SS (28W) & F25/SS (25W)
F40T8 operation: 1 lamp on 2L ballast, 2 lamps on 3L ballast, 3 lamps on 4L ballast

Key System Features

  • Universal voltage (120-277V)
  • Small can enclosure size
  • Lamp Striation Control (LSC)
  • 0.88 ballast factor
  • 30-40% energy savings
  • Min. Starting Temp:
  • -20°F (-29°C) for T8 lamps
  • 60°F (16°C) for Energy Saving T8 lamps
  • 0°F (-18°C) for FO40T8 lamps
  • <10% THD
  • Virtually eliminates lamp flicker
  • RoHS compliant
  • Lead-free solder and manufacturing process

Application Information

QUICKTRONIC 32 UNV ballasts are ideally suited for:

  • Commercial
  • Retail
  • Hospitality
  • Institutional
  • New Construction
  • Retrofit

QUICKTRONIC Professional Series products are typically used in OEM (original equipment manufacturers) standard fixtures and Trade/Distributor Basic stocked products for replacement.

QUICKTRONIC SYSTEM 32 UNV electronic T8 ballasts offer several advantages:

  1. Operate T8 lamps with maximum efficacy and high lumen output
    • 30-40% energy savings when compared to F40T12 magnetically ballasted systems (see table below)
  2. Parallel Circuitry: keeps remaining lamps lit if one or more go out
  3. Small Can Enclosure for:
    • low profile fixture design
    • transportation, inventory and ergonomic benefits
  4. Lamp Striation Control (LSC):
    T8 energy saving lamps should be operated above 60°F, but under certain conditions the lamps may striate. LSC circuitry may minimize or eliminate this condition; however, there are limited applications where LSC circuitry may not entirely mitigate lamp striations.
    These ballasts are also RoHS compliant and feature lead-free solder and manufacturing process.
    These ballasts are also RoHS compliant and feature lead-free solder and manufacturing process.OSRAM-Sylvania-T8-Instant-Start-Universal-Voltage-
Systems-FIG-1OSRAM-
Sylvania-T8-Instant-Start-Universal-Voltage-Systems-
FIG-2

System Information

QUICKTRONIC SYSTEM 32 (QTP) UNV system advantages:

  • Operate from 120V through 277V
  • Eliminates “wrong voltage” errors
  • Reduces inventory by 50%
  • Utilizes Instant Start operation for
  • Highest System Efficacy
  • Low temperature starting capability
  • Very low harmonic distortion (<10%)THD
  • Operate at >42 kHz to reduce potential interference with infrared control systems
  • Customers should always consider upgrading to our High Efficiency Systems to maximize energy savings

SPECIFICATION DATA

OSRAM-Sylvania-T8-Instant-Start-Universal-Voltage-Systems-
FIG-7

Universal Voltage (120-277V), Lamp Striation Control

OSRAM-Sylvania-T8-Instant-Start-Universal-Voltage-Systems-
FIG-3

NAED in parentheses is provided as a cross reference for the new item number.
1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor X 100) divided by Input Power (Note: calculation based on lowest wattage value).OSRAM-
Sylvania-T8-Instant-Start-Universal-Voltage-Systems-
FIG-4

Specification

  • Starting Method: Instant Start
  • Ballast Factor: 0.88
  • Circuit Type: Parallel
  • Lamp Frequency: >42 kHz
  • Lamp CCF: Less than 1.7
  • Starting Temp: 2 -20°F (-29°C) for
  • T8 lamps; 60°F (16°C) for energy-saving T8 lamps 0°F (-18°C) for FO40T8 Input
  • Frequency: 50/60 Hz Low THD:<10%
  • Power Factor: >98%
  • Voltage Range: ±10% of 120-277V rated line (108-305V)
  • 20 ft: full wattage T8s
  • 10 ft: energy saving T8s
  • 4 ft: 25W energy saving T8s

Professional Series

Performance Guide
QUICKTRONIC® 32ISN-SC is compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications.
All models will also operate F17, F25 and F32 (and the energy-saving &U-Bend equivalent) T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the Ballast Technology & Specification Guide.

UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temperature 75°C Max Case Temp. (4-lamp model) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating RoHS Compliant3 ANSI C62.41 Cat. A Transient Protection GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder):

  1. Operation below 50°F (10°C) may affect light output or lamp operation – see “Low Temp. Starting” definition.
  2. Complies with European Union Restriction of Hazardous Substances Directive (Directive EC 2 /95)

Dimensions

  • Overall: 9.5″ L x 1.68″ W x 1.18″ H
  • Mounting: 8.90″
  • Product Weight: 1.6 lbs each (approx.)
  • Wiring: Leads only (no connectors provided)OSRAM-Sylvania-T8-Instant-Start-Universal-Voltage-Systems-FIG-6

Warranty

QUICKTRONIC® Ballasts have a 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/support/warranty/terms-and- conditions

© 2022 Acuity Brands Lighting, Inc.
Specifications subject to change without notice. All trademarks referenced are property of their respective owners. Actual performance may differ as a result of end-user environment and application. Direct replacement LED lamps should not be used unless they have been certified for electrical safety, are compatible with the ballast and are suitable for the intended application environment. Only replacement lamps that comply with applicable lamp and ballast manufacturers’ ratings, compatibility listings and instructions should be used.

QUICKTRONIC North America
877-636-5267
techsupport@quicktronic.com

ECS410R1 4-22
Downloaded from Arrow.com.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>