protech QM1500 Low Cos Digital Multimeter User Manual
- June 11, 2024
- protech
Table of Contents
protech QM1500 Low Cos Digital Multimeter
Product Information
Low Cost HOBBYIST Digital Multimeter QM1500
The QM1500 is a low-cost digital multimeter designed for hobbyist use. It
features a range of functions including DC voltage measurement, AC voltage
measurement, DC current measurement, resistance measurement, diode testing,
and transistor hFE testing.
The device has an LCD screen for displaying readings and measurements, and
input jacks for different types of measurements.
The QM1500 comes with a set of test leads and a hFE socket for transistor
testing.
Product Usage Instructions
AC/DC Voltage Measurement
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the positive V jack.
- Set the function switch to the VAC or VDC position.
- If voltage to be measured is not known, select a measurement range by turning the switch to the preferred option.
Diode Test
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the positive V jack.
- Set the function switch to the diode position.
- Touch the red test probe to the anode of the diode to be measured, and the black test lead to the cathode.
- Reverse the probe polarity by switching the position. Note this reading.
- The diode or junction can be evaluated as follows:
- If one reading shows a value and the other reading shows OL, the diode is good.
- If both readings show OL, the device is open.
- If both readings are very small or zero, the device or circuit is shorted.
Transistor Measurement
- Set the function switch to the hFE position.
- Determine whether the transistor is NPN or PNP.
- Insert the Emitter, Base & Collector leads into the corresponding E, B & C holes in the hFE socket.
- The meter will display the approximate hFE value at the base current of 10 A & VCD 2.8V.
DC Current Measurement
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the desired current range input jack.
- Set the function switch to the desired current range position.
Resistance Measurement
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the desired resistance range input jack.
- Set the function switch to the desired resistance range position.
Battery Installation
- Turn off and disconnect the test leads from the meter.
- Open the rear cover with a screwdriver.
- Remove the old battery and insert the new battery into the battery holder, observing the correct polarity.
- Close the rear cover.
Note: To avoid false readings, replace the battery every 6 months if the device is used regularly.
Low Cost
Digital Multimeter User Manual
Thank you for purchasing this Low Cost Digital Multimeter. This multimeter is
the perfect introduction to meters, and data capture of standard measurements
including DC & AC voltage, DC current, resistance, transistor, and diode
testing. Just move the rotary switch to the correct position, plug in your
leads and you’re good to go!
Please familiarise yourself with the functions of the multimeter before use.
We recommend retaining this manual for ease of reference.
- Improper use of this meter can cause damage, shock, injury or death.
- Always remove the test leads before replacing the battery or fuses.
- Before using this meter, please inspect the condition of the test leads and the meter itself for any damage. If damage is present, please discontinue use.
- Do not measure voltage if the voltage on the terminals exceeds 1000V above earth ground.
- Do not exceed the maximum limits of the input values shown in the specification tables on pages 6-7 of this manual.
- Remove the batteries from the meter if it will be unused for an extended period of time.
- Always turn the function switch to the off position when not in use.
FUNCTIONS
Max. Display| 2000 Count
Basic Accuracy| 0.500%
DC Voltage Range| 200mV – 1000V
AC Voltage Range| 200V – 750V
DC Current Range| 2000 A – 10A
Resistance| 200 to 2000k
Diode Test| Yes
Transistor hFE Test| Yes
FUNCTIONS
Function Switch| Select a measurement range by turning the
switch to the preferred option.
LCD Screen| Readings and measurements taken by the
multimeter will display in this area.
Input Jacks| V mA: Positive input terminal for voltage resistance, diode, temperature, frequency. COM: Negative input terminal for voltage, resistance, diode, temperature, frequency .
10A: Input terminal for 10A current.
SYMBOL
| Diode Test
| Ohms
Hz| Hertz (Frequency)
V| Volts
A, mA, A| Current Range
AC| Alternating Current/Voltage
DC| Direct Current/Voltage
AC/DC VOLTAGE MEASUREMENT
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the positive VS jack.
- Set the function switch to the VAC or VDC position. If the voltage to be measured is not known beforehand, then set the switch to the highest range and reduce it until a satisfactory reading is obtained.
- Connect the test leads to the device of circuit being measured, then turn the device or circuit on.
- Read the voltage on the display.
DC CURRENT MEASUREMENT
- Insert the black test lead banana plug into the negative COM jack
- For current measurements up to:
- a. 200mA DC – Insert the red test lead banana plug into the V jack.
- b. 10A DC – insert the red test lead banana plug into the 10A jack.
- Set the function switch to the desired position.
- Remove power from the circuit under test, then open up the circuit at the point where you wish to measure current.
- Touch the black test probe tip to the negative side of the circuit.
- Touch the red test probe tip to the positive side of the circuit.
- Apply power to the circuit.
- Read the current displayed on the display.
RESISTANCE MEASUREMENT
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the positive V jack.
- Set the function switch to the desired O position.
- If the resistance being measured is connected to a circuit, then turn power off and discharge all capacitors prior to measurement. Then connect he test leads to the circuit.
- Read the resistance on the display.
DIODE TEST
- Insert the black test lead banana plug into the negative COM jack.
- Insert the red test lead banana plug into the positive V jack.
- Set the function switch to the position.
- Touch the red test probe to the anode of the diode to be measured, and the black test lead to the cathode.
- Reverse the probe polarity by switching the probe position. Note this reading.
- The diode or junction can be evaluated as follows:
- a. If one reading shows a value and the other reading shows OL, the diode is good.
- b. If both readings show OL, the device is open.
- c. If both readings are very small or zero, the device or circuit is shorted.
TRANSISTOR MEASUREMENT
- Set the function switch to the hE position.
- Determine whether the transistor is NPN or PNP.
- Insert the Emitter, Base & Collector leads into the corresponding E, B & C holes in the hE socket.
- The meter will display the approximate hE value at the base current of 10MA & VCD 2.8V.
MEASUREMENT SPECIFICATIONS
DC Voltage
RANGE | RESOLUTION | ACCURACY |
---|---|---|
200mV | 100 V | **** |
(±1.0% of reading + 10 digits)
2000mV| 1mV
20V| 10mV
200V| 100mV
1000V| 1V
Overload protection: 220VAC for 200mV range, 1000VDC or 750VAC for other ranges.
AC VOLTAGE
RANGE | RESOLUTION | ACCURACY |
---|---|---|
200V | 100mV | (±1.2% of reading + 10 digits) |
750V | 1V |
- Overload Protection: 1000VDC or 750VAC for all ranges.
- Response: Average, calibrated in RMS of SINE.
- Frequency Range: 45Hz-450Hz
DC CURRENT
RANGE | RESOLUTION | ACCURACY |
---|---|---|
2000 A | 1 A | **** |
(±2.0% of reading + 10 digits)
20mA| 10 A
200mA| 100 A
10A| 10mA| (±2.5% of reading + 10 digits)
- Overload Protection: 500mA/250V fuse (10A range unfused).
- Measuring Voltage Drop: 200mV
RESISTANCE
RANGE | RESOLUTION | ACCURACY |
---|---|---|
200 | 0.1 | (±1.0% of reading + 8 digits) |
2000 | 1 | **** |
(±1.2% of reading + 8 digits)
20k| 10
200k| 100
2000k| 1k
- Maximum Open Circuit Voltage: 2.8V
- Overload Protection: 15 seconds maximum, 220V RMS all ranges
- Audible continuity
MAINTENANCE
BATTERY INSTALLATION
To avoid false readings, replace the battery every 6 months if the device is
used regularly.
- Turn power off and disconnect the test leads from the meter.
- Open the rear cover with a screwdriver.
- Remove the old battery and insert the new battery into the battery holder, observing the correct polarity.
- Put the battery cover back in place and secure it with a screwdriver.
REPLACING FUSES
- Turn power off and disconnect the test leads from the meter.
- Remove the cover.
- Gently remove the old fuse and install the new fuse into the holder.
- Always use a fuse of the proper size and value (500mA/250V).
- Replace and secure the cover.
SPECIFICATIONS
- Display: 2000 Count
- Security Class: Cat II 500V
- Basic DCV Accuracy: 0.500%
- DC Voltage: 200mV, 1000V (‡ 0.5%)
- AC Voltage: 200V, 750V (max input 750V RMS) (‡ 1.2%)
- DC Current: 2000MA, 20mA, 200mA, 10A (‡ 1.2%)
- Resistance: 2000, 20000, 20kQ, 200k, 2000k (‡ 1.2%)
- Measurement Type: Average
- Input Impedance: 1
- Dimensions: 125(H) × 68(W) × 23(H)mm
- Weight: 140g
- Battery Type: 9V (Included)
BOX CONTENTS
- 1 x Multimeter
- 2 x Test leads
- 1 x 9V Battery (Installed)
- 1 x User Manual
WARRANTY
The product is protected by a 2-year warranty (from the date of purchase
covering all product manufacturing defects/faults that may occur within this
timeframe. This warranty does not cover damage caused by neglect, misuse,
contamination, alteration, accident or abnormal conditions of operation or
handling, including failures caused by use outside of the products
specifications, or normal wear and tear of the mechanical components.
In the event that you suspect your product is defective/faulty, cease using
the product when the suspected defect/fault arises and return the product
along with proof of purchase to the place of purchase or distributor for
assessment. Distributer contact details are available on the last page of this
manual.
If the assessment concludes that the product is indeed defective/faulty, the
product will either be repaired or replaced at no cost to you.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure.
- Distributed by:
- Electus Distribution Pty Ltd
- 46 Eastern Creek Dr,
- Eastern Creek NSW 2766 Australia
- Ph 1300 738 555
- Int’l +61 2 8832 3200
- Fax 1300 738 500
- www.electusdistribution.com.au
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>