Metoluar WT0124 Professional Wireless Pool Thermometer Instruction Manual

June 9, 2024
Metoluar

Metoluar WT0124 Professional Wireless Pool Thermometer Instruction Manual

Metoluar WT0124 Professional Wireless Pool Thermometer Instruction
Manual

Receiver

♦ Full Display

♦ Specifications:

  1. Calendar from Jan. 1st, 2000 to Dec.31st ,2099
  2. Alarm with snooze;
  3. Water temperature range:-40℃to +60℃;
  4. Indoor temperature range:0℃ to +50℃;
  5. 433MHZ wireless receives 3 channel’s water temperature;
  6. CH1/CH2/CH3 there are three receiving and transmitting channels, which can be freely matched by users. Three transmitters are equipped with a receiver, which can measure data in three different areas.
  7. Max/min record of indoor and water temperature.
  8. WT0124/0224 No humidity function, WT0226/WT0228hashumidity function, for users to choose.

Connecting an indoor and outdoor machine:

Install the outdoor unit battery first and then the indoor unit battery. The product starts to search for outdoor sensor signals. During the search, the signal icon will blink all the time to ensure that it is effective in an open area with no shielding and no interference source at an effective distance of 100 meters. Do not perform any operation on the unit during the search.

Keys:

  1. [MAX/MIN]:
    In normal clock mode, press [MAX/MIN] to toggle the display of maximum , minimum and current data of indoor temperature and water temperature.

  2. [CLEAR]:
    [CLEAR]: When maximum and minimum values are displayed, press the [CLEAR] button to CLEAR the maximum and minimum values of indoor temperature and water temperature, and immediately update the maximum and minimum values with the current values of indoor temperature and water temperature.

  3. [CH]:
    In normal clock mode, press [CH] to toggle water temperature of channel 1/2/3.

  4. [C-F]: Press[C-F]totoggletemperatureunitbetween[℃/℉] When setting the time format mode, press [C/F] to switchto12/24 hour format.
    In alarm mode, press the [℃/℉] key to enable/disable the alarm function.
    In date format mode, press the [℃/℉] key to switch between MM-DD and DD-MM.

  5. [MODE] :Press [MODE] to toggle modes

  6. [SET] :Press [SET] to get into setting mode. Such as year, month, date, hour, minute, second etc.)

♦ Operation statement

Press [MODE] to toggle between clock mode and alarm mode.

♦ Clock Mode

In normal clock mode, LCD displays indoor temperature, water temperature, month, date, week, hour, minute, second, and reception channel. As shown below:

  1. Press [SET] to enter time format setting mode, press[℃/
    ℉] or [MAX/MIN] to toggle between 12/24 hour
    format.

  2. Press [SET] to enter hour setting mode. While the number
    of hour is flashing, press [℃/℉] or[MAX/MIN]adjust it. And press [℃/℉] or[MAX/MIN]for more than 2 seconds to adjust in 8HZ.

  3. Press [SET] to switch to minute setting mode. While the number of minute is flashing, press [℃/℉] or[MAX/MIN] to adjust it. And press [℃/℉] or[MAX/MIN] for more than2seconds to adjust in 8HZ.

  4. Press [SET] to switch to second setting mode. While the number of second is flashing, press [℃/℉] or[MAX/MIN]toclear it.

  5. Press [SET] to confirm and quit clock setting mode, then back to normal clock mode.

  6. In normal clock mode, press [MAX/MIN] to toggle the maximum, minimum and current data of indoor temperature and water temperature. When displaying maximum/minimum data of indoor and water temperature, press [CLEAR] to clear the data.

  7. Press [CH] to toggle channel 1,channel 2 and channel 3.

  8. Press [C-F] to toggle temperature unit between ℃and℉.

  9. If no button is pressed in 1 minute in clock setting mode, it will be back to clock mode automatically.

  10. Press [MODE] to enter alarm mode.

♦ Alarm Mode

In normal clock mode, press [MODE] to enter alarm mode. LCD displays indoor temperature, water temperature, month, date, week, hour, minute, and reception channel. As shown below:

  1. Press [SET] to enter hour setting mode. While the number of hour is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN] for more than 2secondstoadjust in 8HZ
  2. Press [SET] to enter hour setting mode. While the number of hour is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN] for more than 2secondstoadjust in 8HZ
  3. Press [SET] to enter munite setting mode. While the number of minute is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN] for morethan2 seconds to adjust in 8HZ
  4. Press [SET] to confirm and quit.
  5. In alarm non-setting mode, press [℃/℉] or [MAX/MIN] to open/close alarm..
  6. If no button is pressed in 1 minute in alarm setting mode, it will be back to clock mode automatically.
  7. Press[MODE] to enter date mode.

♦ Date Mode

In normal clock mode, press [MODE] 2 times to enter date mode. LCD displays indoor temperature, water temperature, month, date, week. As shown below:

  1. Press [SET] to enter year setting mode. While the number of year is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN] for morethan2 seconds to adjust in 8HZ.
  2. Press [SET] to enter date format setting mode, press[℃/℉] or [MAX/MIN] to select between YY-MM-DD and YY-DD-MM format.
  3. Press [SET] to switch to month setting mode. While the number of month is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN]for morethan2 seconds to adjust in 8HZ.
  4. Press [SET] to switch to date setting mode. While the number of date is flashing, press [℃/℉] or [MAX/MIN] to adjust it. And press [℃/℉] or [MAX/MIN] for morethan2 seconds to adjust in 8HZ.
  5. Press [SET] to confirm and quit.
  6. If no button is pressed in 1 minute in date setting mode, it will be back to clock mode automatically.
  7. In date mode, press [CHANNEL] to enter the RF test condition, and it will quit this mode automatically 30seconds later

♦ Alarm with Snooze

  1. When alarm is open, and it reaches the alarm time, it will buzzer “BI“ for one minute with the alarm icon flashing.
  2. While alarming, press [CHANNEL] or no key pressed to stop alarming. At this time, “BELL” icon flashing, it will enter snooze. Five minutes later, it will alarm. After the3th alarming, it will no longer enter snooze.
  3. While alarming, press any key to stop alarming, but not enter Snooze;
  4. While snoozing, quit snoozing if enter setting mode.
  5. In any mode, when reaches alarming time, press any key to close the alarm.

♦ Power Consumption:

  1. Alkaline battery:2×AAA 1.5V
  2. Battery life: about 12 months

♦ Dimension (H×W×D)

119mm×74mm×21mm.

Transmitter

Metoluar WT0124 Professional Wireless Pool Thermometer -
Transmitter

♦ Feature

  1. 0℃ to +60℃ water temperature monitoring
  2. Temperature unit: ℉/℃
  3. Frequency: RF 433MHz, Working Distance: 100minopen space
  4. Channel for option: CH1, CH2 & CH3
  5. Solar panel charges batteries if rechargeable batteries are used(This function only applies to WT0124, WT0122hasnot this function)

♦ Operation:

Temperature monitor and data transmitter

  1. Interval of data transmitting: 30seconds
  2. Where data is transmitting, there is signal icon on the LCD and meanwhiel the LED light flashes.

♦ Switches description

Taking the following chart to set channel, temperature unit and turn on solar charging and use rechargeable batteries if you turn on solar charging function, Otherwise, pls keep solar switch in off position).

Metoluar WT0124 Professional Wireless Pool Thermometer - Switches
description

♦ Power supply

  1. Alkaline battery or rechargeable battery: 2×AA1.5V
  2. Battery life span: alkaline battery 12 months Rechargeable battery 2 year.

● Battery Installation Instruction

  1. Twist off the cover of the transmitter, then takeout the battery compartment:
    Metoluar WT0124 Professional Wireless Pool Thermometer - Twist off the cover
of the transmitter

  2. Open the cover of battery compartment, install batteries, then close the battery cover:
    Metoluar WT0124 Professional Wireless Pool Thermometer - Open the cover of
battery compartment, install batteries

  3. Install the waterproof loop, then close and tighten the cover of the transmitter.
    Metoluar WT0124 Professional Wireless Pool Thermometer - Install the
waterproof loop, then close and tighten the cover

  4. If the battery is dead, or when you need to open the lid, please pay attention to first clean the external water; avoidwaterinside the product.

Matters needing attention:

  1. The battery life is related to the working state. Please ensure that the battery voltage is normal. If the indoor or outdoor unit
    battery symbol is blinking, replace the battery immediately.

  2. When the product is powered on, the data collected by the sensor will be stable and accurate only after about 30minutes.

  3. Before putting the outdoor unit into water, ensure that the waterproof ring is installed properly and the cover istightened.

  4. Outdoor unit solar power supply, please ensure that the DIP switch 4 is effective.

Tkm210922

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals