BROMIC Eclipse Smart Heat Electric Heaters Instruction Manual
- June 9, 2024
- Bromic
Table of Contents
- BROMIC Eclipse Smart Heat Electric Heaters
- Product Usage Instructions
- Operation Instructions
- Maintenance & Servicing
- Important Safety Instructions
- PRODUCT DESCRIPTION
- PRODUCT SPECIFICATIONS
- PRODUCT FEATURES
- KEY DIMENSIONS & CLEARANCES
- Instructions for Single Pole options, including
- IMPORTANT NOTES & WARNINGS
- PENDANT HEATER CONTROL WIRING DIAGRAM
- OPERATING INSTRUCTIONS
- MAINTENANCE & SERVICING
- TROUBLESHOOTING
- REPLACEMENT PARTS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BROMIC Eclipse Smart Heat Electric Heaters
Product Information:
The Eclipse Smart-HeatTM Electric Heaters by Bromic are electric heaters
designed for indoor and outdoor use. These heaters are available in ceiling-
mounted, wall-mounted, and pendant models.
They come with a remote control for easy operation and have various safety
features to prevent fire, electrical shock, and injury to persons.
Product Usage Instructions
Installation Instructions – Ceiling Mounted Heater
- Ensure that the installation location complies with all relevant codes and regulations.
- Remove all packaging materials from the heater.
- Attach the mounting bracket to the ceiling using appropriate screws and anchors.
- Install the heater onto the mounting bracket.
- Connect the electrical supply to the heater using a licensed electrician.
- Test the heater to ensure proper operation.
Installation Instructions – Wall Mounted Heater
- Ensure that the installation location complies with all relevant codes and regulations.
- Remove all packaging materials from the heater.
- Attach the mounting bracket to the wall using appropriate screws and anchors.
- Install the heater onto the mounting bracket.
- Connect the electrical supply to the heater using a licensed electrician.
- Test the heater to ensure proper operation.
Electrical Installation – Pendant Heater Controls
- Ensure that the installation location complies with all relevant codes and regulations.
- Remove all packaging materials from the heater.
- Connect the pendant control to the heater using the appropriate wiring.
- Connect the electrical supply to the pendant control using a licensed electrician.
- Test the heater to ensure proper operation.
Contents Packed in (3) Boxes
Tools/Parts Required (not Included)
- Bolts for fastening to Ceiling surface
- Phillips Head Screw Driver
- Step Ladder
- 2 strong people to help with lifting & assembly
- Spirit Level
WARNING
This heater MUST be installed by a licensed electrical contractor. Do not
perform maintenance, or carry out installation or assembly procedures while
electrical power is switched on. Wait 2 hours after switching off the heater
before handling to prevent touching hot surfaces.
For the longest product life and to maintain product appearance, position
heater undercover and protect from rain and weather.
IMPORTANT
The appliance must be installed such that the heater head is level with the
ground.
The appliance must be mounted on a solid surface, and it is the responsibility
of the installer to assess the suitability of the mounting surface.
The minimum distance between heaters measured from edge of heater must be at
least 500 mm.
Caution – Glass – Handle with care
- Care must be taken during installation. After removing the packaging, glass must be inspected for damage before use. If damage to the appliance is suspected, discontinue use immediately and contact the supplier.
- Check for damage to the appliance before each use. The heater must not be used if the glass panel or any other part of the heater is damaged. If damage to the appliance is suspected, discontinue use immediately and contact the supplier.
- Care must be taken around the appliance to ensure it is not damaged. Ball games that could accidentally hit the heater must not be played around the appliance. To protect the appliance do not remove cardboard packaging from head assembly until it is mounted to arm and base.
Operation Instructions
- To turn on the heater, use the remote control and press the “ON” button.
- To turn off the heater, use the remote control and press the “OFF” button.
- To pair the remote control with the heater, follow the instructions in the manual.
Maintenance & Servicing
- Regularly clean the heater with a soft, damp cloth.
- If the heater is not functioning properly, refer to the troubleshooting section of the manual.
- If replacement parts are needed, contact Bromic Pty Ltd.
Important Safety Instructions
Always follow basic precautions when using electrical appliances to reduce the risk of fire, electrical shock, and injury to persons. Refer to the safety information shown throughout the instruction manual, which will be accompanied by safety alert symbols including DANGER, ! WARNING, ! IMPORTANT.
Ensure that the installation location complies with all relevant codes and regulations. Use a licensed electrician for all electrical connections. Do not place any objects in front of the heater head. Do not dispose of this product with other household waste. Recycle it responsibly to promote the sustainable reuse of material resources.
WARNING
-
IMPORTANT – Installation MUST be carried out by a licensed electrical contractor.
-
Heater must be installed by 2 persons.
-
Improper installation, adjustment, or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death or property damage.
-
The manufacturer is not responsible for any damage resulting from improper use. The manufacturer emphasizes that this appliance should be used in a responsible manner and that all procedures, warnings, and safety instructions contained in this booklet should be followed strictly.
-
The installer is to ensure that the requirements of the local authority, local electrical installation code, municipal building codes, and any other relevant statutory regulations are carried out.
-
Do not use or store flammable materials near this appliance.
-
This installation, operation and service manual should not be removed from the site of installation. Installer should leave manual with the customer for future reference.
-
A minimum safety distance of 1 metre should always be left in front of the Heater Head.
-
The Heater head must be installed at least 2.4 metres above the floor.
-
The Heater must not be located immediately below or
in front of an electrical socket outlet. Heat radiated from the appliance may damage the electricity outlet or plug if placed incorrectly. -
Any guard or other protective device removed for servicing (conducted by a licensed electrical contractor) must be fitted in place before operating the heater.
-
This appliance can be used by children aged from 12 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised.
-
Children shall not play with the appliance.
-
Cleaning and user maintenance shall not be made by children without supervision.
-
Children of less than 12 years should be kept away unless continuously supervised.
-
Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present.
-
Keep packaging materials out of reach of children.
-
Do not spray aerosols or flammable materials in the vicinity of this appliance while it is in operation or whilst heater surface is hot.
-
Installation and repair must be carried out by a qualified and licensed electrical contractor only. The heater should be inspected before use and at least annually serviced and inspected by a qualified and licenced service technician.
-
The Heater Head has no serviceable parts. For the Poles, please refer to the Maintenance and Servicing section for more details regarding troubleshooting and replacement parts.
-
The LED contained in this luminaire is non-replaceable and must not be removed.
-
Do not perform maintenance until heater has been turned off, power disconnected, and heater temperature has cooled to room temperature.
-
Certain materials or items, when stored under or near the appliance, will be subjected to radiant heat and could be discolored or seriously damaged. Combustible materials e.g. floors, furniture, fixtures and plants must be kept a minimum of 1 meter from the front of the heater head.
-
Be sure the heater is not facing the ceiling or flammable or combustible substances/ materials.
-
This radiant heater is NOT intended to be installed on or in vehicles and/or boats.
-
Do not attempt to alter the unit in any manner.
-
Remove all transit protection & packaging before use.
-
Do not paint any surface of the heater.
-
Care must be taken during installation. After removing the packaging, glass must be inspected for damage before use. If damage to the appliance is suspected, discontinue use immediately and contact the supplier.
-
Check for damage to the appliance before each use. The heater must not be used if the glass panel or any other part of the heater is damaged. If damage to the appliance is suspected, discontinue use immediately and contact the supplier.
-
Care must be taken around the appliance to ensure it is not damaged. Ball games that could accidentally hit the heater must not be played around the appliance.
-
After unpacking, make sure the appliance shows no signs of visible damage or tampering. If the appliance appears damaged, contact the place of purchase for assistance.
-
This appliance must only be used on a 220-240V AC single-phase power supply.
-
Do not touch the heating surface at any time, even when the heater is turned off and has cooled down.
-
Do not touch the heater with wet hands at any time.
-
At the end of this product’s useful life, it must not be disposed of as domestic waste, but must be taken to a collection centre for waste electrical and electronic equipment. It is the user’s responsibility to dispose of this appliance through the appropriate channels at the end of its useful life. Failure to do so may incur the penalties established by local laws governing waste disposal. Proper differential collection, and the subsequent recycling, processing and environmentally compatible disposal of waste equipment avoids unnecessary damage to the environment and possible related health risks, and also promotes recycling of the materials used in the appliance. For further information on waste collection and disposal; contact your local waste disposal service or the place of purchase.
-
In case of direct connection to a supply line, a bipolar circuit breaker with contact opening distance of at
least 3 mm must be fitted upstream from the supply line. Contact an authorised service technician if you
are unsure if you have a circuit breaker installed on the premises. -
Do not install the heater directly near a bathtub, shower, swimming pool or other body of water. Any switches or controls must not be within reach of a person in the bathtub, shower, swimming pool or other body of water.
-
To maintain Ingress Protection Rating (IP54), only suitable IP54 (or better) rated outdoor plug & sockets should be used for electrical installation.
-
This product does not have a switch for electrical disconnection. A means for disconnection of the heater must be incorporated in the wall socket & fixed wiring according to the local electrical codes.
-
If the supply cable is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a safety hazard.
-
This heater is not equipped with a device to control
the room temperature. Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own, unless constant supervision is provided.
Do not excessively bend the electrical connection to the power supply. -
Keep the electrical cable away from sharp edges during handling and installation.
-
Do not pull on the electrical cable or subject it to traction force.
-
Caution should be taken when dismantling goods from shipping containers to prevent from injury when lifting heavy parts. Maximum safe lifting 16kg per person.
-
Do not install heater to an unsecured structure. Mounting surface integrity shall be determined suitable by the installer based on weight & type of mounting option chosen.
-
Do not lean on heater or rest any objects leaning up against heater, including the arm.
-
Do not hang any foreign items off any part of this appliance e.g. do not hang towels, clothing, lines, lights, cables.
-
Do not swing from arm or heater head.
-
Do not stand or sit on any part of heater, including the base.
-
Do not use heater if Heater Head is not level with the ground. Angle must be checked during assembly using spirit level (not included).
-
Do not use heater if heater head or pole is loose.
-
Check the product label for correct voltage and wattage to ensure power source conforms to the heater’s requirements.
-
The exterior housing of the heater should be cleaned regularly. To clean the appliance; ensure heater is off and has been off for at least 2 hours after operation, before wiping off any dirt/dust with a soft damp cloth & glass cleaner. Salt in the air can cause rusting of metal, especially at locations near the coast. Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product’s appearance.
-
Do not clean heater with cleaners that are combustible or corrosive.
PRODUCT DESCRIPTION
The Eclipse Smart-HeatTM Electric is designed to provide efficient space
heating for commercial and residential applications.
The Eclipse Smart-HeatTM Electric heaters have electrical approval in
Australia, New Zealand, USA, Canada, Europe, UK, and are rated to IP54 for
Ingress Protection, making the Eclipse Smart-HeatTM Electric Portable the
perfect solution for a variety of indoor and outdoor heating applications.
PRODUCT SPECIFICATIONS
SPECIFICATIONS
Model| Eclipse Smart-HeatTM Electric
Part No (Heater Eclipse Pendant AU)| 2620621-1
Part No (Straight Ceiling Mount Pole 203mm)| 2620631
Part No (Straight Ceiling Mount Pole 610mm)| 2620632
Part No (Twin Straight Ceiling Mount Pole 610mm)| 2620633
Part No (Curved Ceiling Mount Pole 610mm)| 2620634
Part No (Straight Ceiling Mount Pole 1219mm)| 2620635
Part No (Wall Mount Pole)| 2620636
Part No (Eclipse Pendant Control AU)| 2620637-1
Appliance Output (watts)| 2700 – 3000 W
Light Output (watts)| 13 W @ 24 V DC
Power Connection Required (Volts)| 220-240 V – a.c. – 50-60 Hz
Ingress Protection| IP54
Heater Head Dimensions (W x H x D)| 700 x 700 X 111 mm
Heater Head Weight| 13.5 kg
Finish| Matt Black
Approval
|
Certificate of Approval SGS/210281
PRODUCT FEATURES
- Stylish, slimline and contemporary design to suit any decor.
- Efficient directional space heating with 3 built in heat levels.
- Heaters can also be integrated into smart control systems
- Wind resistant & IP54 water protection rating
- Suitable for outdoor and indoor heating applications such as restaurants, cafes, bars and clubs, factories, office spaces, designated smoking areas, public areas, hotels, homes and more.
KEY DIMENSIONS & CLEARANCES
Heaters must be installed according to the minimum installation clearances shown in these diagrams. Dimensions shown in: mm
PENDANT & WALL MOUNT
The stated clearance to combustible materials represents surface temperature of 65°C above room temperature. Building material with a low heat tolerance (such as plastic, vinyl siding, canvas, tri-ply etc.) may subject to degradation at lower temperatures. It is the installer’s responsibility to assure that adjacent materials are protected.
Instructions for Single Pole options, including
- Curved Ceiling Mount Pole 610mm
- Straight Ceiling Mount Pole 203mm
- Straight Ceiling Mount Pole 610mm
- Straight Ceiling Mount Pole 1219mm
-
Unpack all items from shipping cartons and place items on a non-abrasive surface.
To protect appliance do not remove cardboard packaging from head assembly until it is mounted to ceiling. -
Fasten the Pendant Mount Roof Bracket on the ceiling in the desired location, using appropriately sized and type bolts (not included) for the mounting surface.
Ensure the bracket is firmly secured to appropriate supports (not only to ceiling panels) with fasteners in 4 opposing holes before proceeding.
IMPORTANT
Fasteners must be chosen by the installer to suit the mounting structure. Installer is responsible for chosing fasteners appropriate to the loading of the product. -
Attach the chosen Ceiling Mount Pole to the Pendant Mount Roof Bracket using the
4 X Dome Head Screws (M4 – Length: 6mm).
Shown on right are the four options for the Single Ceiling Mount Poles. -
4. Slide the Round Cap over the Ceiling Mount Pole and attach the it to the Roof Bracket using 2 X Dome Head Screws (M4 – Length: 10mm).
! WARNING
Heavy Item. Min Two-Person Lift. Maximum safe lifting 16 kg per person. -
Feed the cable through the Ceiling Mount Pole until it has passed through and out into the roof cavity. Feed through the cable slack, and with the help of a second person, lift the Heater Head upwards closer to the Ceiling Mount Pole.
-
Insert the Heater Bracket into the Ceiling Mount Pole by hooking the attached 2X Dome Head Screws (M4 – Length: 6mm) into the slot feature in the Pole.
Note: Screws are pre-assembled to heater head bracket. -
Fully insert additional 2 X Dome Head Screws (M4 – Length: 6mm) on both sides, and tighten all four screws, to lock the heater in place.
-
DANGER!
All packaging materials must be removed before turning on the appliance.
Instructions for Twin Pole option:
- Twin Straight Ceiling Mount Pole 610mm
-
Unpack all items from shipping cartons and place items on a non-abrasive surface.
To protect appliance do not remove cardboard packaging from head assembly until it is mounted to ceiling. -
Fasten the Twin Pole Roof Bracket on the ceiling in the desired location, using appropriately sized and type bolts (not included) for the mounting surface.
Ensure the bracket is firmly secured to appropriate supports (not only to ceiling panels) with fasteners in 4 opposing holes before proceeding.
IMPORTANT
Fasteners must be chosen by the installer to suit the mounting structure. Installer is responsible for choosing fasteners appropriate to the loading of the product. -
Place the Twin Pole Cap loosely onto the Twin Straight Ceiling Mount Pole as shown below, and attach the Twin Straight Ceiling Mount Pole to the Twin Pole Roof Bracket using the 4 X Dome Head Screws (M4 – Length: 6mm).
-
Slide the Twin Pole Cap upwards and attach the it to the Twin Pole Roof Bracket using
2 X Dome Head Screws (M4 – Length: 6mm).
2x M4 – Length: 6mm
! WARNING
Heavy Item. Min Two Person Lift. Maximum safe lifting 16 kg per person. -
Feed the cable through one of the poles of the Twin Straight Ceiling Mount Pole until it has passed through and out into the roof cavity. Feed through the cable slack, and with the help of a second person, lift the heater head upwards closer to the Twin Straight Ceiling Mount Pole.
-
Insert the Heater Bracket into the Twin Straight Ceiling Mount Pole by hooking the attached 2X Dome Head Screws (M4 – Length: 6mm) into the slot feature in the Pole.
-
Fully insert additional 2 X Dome Head Screws (M4 – Length: 6mm) on both sides, and tighten all four screws, to lock heater in place.
2x M4 – Length: 6mm -
DANGER!
All packaging materials must be removed before turning on the appliance.
Wall Mounted Heater
Tools/Parts Required (not Included)
- Bolts for fastening to Wall surface
- Phillips Head Screw Driver
- Allen Key
- Step Ladder
- 2 strong people to help with lifting
- Spirit Level
WARNING
This heater MUST be installed by an licensed electrical contractor. Do not
perform maintenance, or carry out installation or assembly procedure while
electrical power is switched on. Wait 2 hours after switching off the heater
before handling.
For longest product life and to maintain product appearance, position heater
under cover and protect from rain and weather.
IMPORTANT
The appliance must be installed such that the heater head is level with the
ground.
The appliance must be mouted on a solid surface, and it is the responsibility
of the installer to assess the suitibility of the mounting surface.
Minimum distance between heaters measured from edge of heater must be at least
500 mm.
Caution – Glass – Handle with care
-
Care must be taken during installation. After removing packaging, glass must
be inspected for damage before use. If damage to the appliance is suspected, discontinue use immediately and contact the supplier. -
Check for damage to the appliance before each use. The heater must not be used if the glass panel or any other part of the heater is damaged. If damage to the appliance is suspected, discontinue use immediately and contact the supplier.
-
Care must be taken around the appliance to ensure it is not damaged. Ball games that could accidentally hit the heater must not be played around the appliance. To protect appliance do not remove cardboard packaging from head assembly until it is mounted to arm and base.
Instructions for Wall Mounted option:
-
Unpack all items from shipping cartons and place items on a non-abrasive surface.
To protect appliance do not remove cardboard packaging from head assembly until it is mounted to ceiling. -
Mount the Wall Bracket on the wall in the desired location, using appropriately sized and type bolts (not included) for the mounting surface. Ensure the bracket is firmly secured with fasteners in the 6 holes before proceeding.
IMPORTANT
Fasteners must be chosen by installer to suit mounting structure. Installer is responsible for chosing fasteners appropriate to the loading
of the product. Calculated tensile load on each screw is 3kN (with FOS of 4). -
3. Slide the Wall Bracket Cover over the Wall Bracket.
-
Fasten the Wall Bracket Cover using 1 X Dome Head Screw (M4 – Length: 10mm). 1x M4 – Length: 10mm
-
Feed the cable through the end of the Wall Mount Pole until it has passed through and out the end of the Pole. Feed through the cable slack, bringing the heater head closer to the Wall Mount Pole.
-
Insert the Heater Head Bracket into the Wall Mount Pole by hooking the attached 2X Dome Head Screws (M4 – Length: 6mm) into the slot feature in the Pole.
NOTE: Heater head should be positioned so that the bromic logo on the glass is at the front of the heater (furtherst away from the wall). -
Fully fasten additional 2 X Dome Head Screws (M4 – Length: 6mm) on both sides, and tighten all four screws, to lock heater in place.
2x M4 – Length: 6mm
! WARNING
Heavy Item. Min Two Person Lift. Maximum safe lifting 16 kg per person. -
Attach the Wall Mount Pole to the Wall Bracket. Feed the cable through the back slot of the Wall Mount into the wall cavity, or alternatively, the cable can be fed out
of the optional Cable Slot in the underside of the Wall Bracket. In this instance
attach an M20 metal cable gland (not supplied) into the same hole from the outside of the bracket. -
Fasten the Wall Mount Pole to the Wall Bracket using 1 X Round Head Hex Screw (M8 – Length: 15mm).
1x M8 – Length: 15mm -
Lock the angle of the Wall Mount Pole to the Wall, using 2 X Dome Head Screw
(M6 – Length: 10mm). The Wall Bracket angle can be adjusted up to 45° from the wall on each side.
2x M6 – Length: 10mm -
If the cable has been routed into the wall cavity, Insert the Cable plug into the optional cable slot.
-
DANGER!
All packaging materials must be removed before turning on the appliance.
IMPORTANT NOTES & WARNINGS
WARNING
This heater MUST be installed by an authorised/licenced person. Do not perform
maintenance, or carry out installation or assembly procedure while electrical
power is switched on.
DANGER
ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from
electrical supply before installing or servicing this heater. Read and follow
installation clearance requirements outlined in this manual. The appliance
MUST be connected to a properly grounded electrical source. Isolate mains
before installing. Use only with a properly secured heater.
IMPORTANT
- Pendant Heater controls generate heat during operation. Controls MUST be mounted in a clean, dry and well-ventilated position, with clearance on all sides, and where ambient temperature does not exceed 30°C. Controls MUST remain cool at all times.
- Controls MUST NOT be installed in a confined space, close to other heat generating appliances or in the case of a multi-control installation, a minimum clearance of 300 mm between all sides of adjacent controls. For further questions please contact Bromic technical support services.
- Check product label for correct voltage and wattage to ensure power source conforms to the heater’s requirements.
- Use appropriate power supply cables for the heaters’ voltage and wattage. The fixed wiring must be positioned away from & protected from the enclosure of the heater.
- Make all connections in accordance with local electrical code regulations. For outdoor installation, all connections must be made in accordance with local electrical code regulations for outdoor wiring. Only use wiring components approved for outdoor use with minimum IP54 rating.
- PLUG AND SUPPLY CORD: Use an appropriately rated plug and supply cord – check the power requirements of the connected loads. Socket outlet used must be near the equipment.
- Study the WIRING DIAGRAM at the end of this document before starting installation.
- OVER CURRENT DEVICE: The outputs are NOT protected against short circuits or extra-currents which can damage the electronic board. Evaluate the characteristics of the connected loads and apply the appropriate safety devices to the power line.
- ISOLATION SWITCH: This product does not have a switch for electrical disconnection. A means for disconnection of the heater must be incorporated in the wall socket & fixed wiring according to the local electrical codes.
- The Pendant Heater Control must be mounted using the following guidelines:
- It must be fixed on surfaces which cannot be damaged by high temperature or UV.
- It must be fixed in a well-ventilated location where ambient temperature does not exceed 30°C.
- Connection cables must be protected against any accidental impacts, using proper piping/conduits.
- Do not cover the product.
- Do not use or store flammable materials close to the product.
IMPORTANT
The controller must be installed in a space with free and open air flow which
ensures ambient temperature does not exceed 30°C.
-
Open cover to the Pendant Control Box, by removing 6x Oval head screws (#4-40 -Length: 1/2”) from the cover.
DANGER
The Power source MUST NOT be live when installing the Eclipse Control Box. -
Wire the power supply (not included) as per the wiring diagram. The Live, Neutral and Ground supply wires connect to their corresponding L, N and Ground WAGO
3-way quick connectors. -
3. Refit cover to the box, ensuring the 6 X M3 O-Rings are present on the 6x Oval head screws (#4-40 – Length: 1/2”).
DANGER
The Power source MUST NOT be live when installing the Eclipse Control Box. -
4. Wire the 6 Core Cable from the Eclipse Control Box to the Corresponding coloured wires on the 6 core cable from the Eclipse Heater Head, according to local Electrical Code regulations.
Ensure connection is adequately protected from the environment using an IP54 (or better) cover (not included) suitable for the application.
IMPORTANT
The controller must be installed in a space with free and open air flow which ensures ambient temperature does not exceed 30°C. -
Mount the Pendant Heater Control to the desired ceiling or wall location using appropriately sized and type screws (not included) for the mounting surface. Ensure the Pendant Heater Control is firmly secured with fasteners in the 4 holes before proceeding.
FOR INSTALLATION USING BROMIC ECLIPSE PENDANT CONTROL
(Bromic Eclipse Pendant Control supplied separately)
ONLY TO BE INSTALLED & SERVICED BY LICENSED & AUTHORIZED TECHNICIAN. APPLIANCE
MANUAL MUST BE READ BEFORE INSTALLING OR SERVICING THIS PRODUCT .
PENDANT HEATER CONTROL WIRING DIAGRAM
FOR INSTALLATION NOT USINGBROMIC ECLIPSE PENDANT CONTROL
ONLY TO BE INSTALLED & SERVICED BY LICENSED & AUTHORIZED TECHNICIAN. APPLIANCE
MANUAL MUST BE READ BEFORE INSTALLING OR SERVICING THIS PRODUCT.
NOTES:
- Supply connection must be protected with appropriate safety device, that includes iso-lation switch.
- Suitable junction box for connection to be supplied by installer.
- Control must be located in an environment of no more than 30°C ambient, away from other heat sources and separation clearances maintained.
- Wiring must be completed according to local electrical code.
- 24V DC lighting circuit is to be separated inside the junction box from 220-240VAC circuits.
- Electrical installation must ensure earth continuity is checked.
OPERATING INSTRUCTIONS
REMOTE CONTROL FUNCTIONS
(SUPPLIED WITH BROMIC ECLIPSE PENDANT CONTROL)
TURNING THE APPLIANCE ON
- Using the Remote Control, select the desired Heater setting:
- Heater 100% – Heater output at full (100%).
- Heater 66% – Heater output at 66% of total.
- Heater 33% – Heater output at 33% of total.
- Using the Remote Control, select the desired Light setting:
- Lights 100% – Lights output at full (100%).
- Lights 50% – Light output at 50% of total.
- To Lower lights, Press & Hold OFF DIM^ until the lights have lowered to the desired level.
- To Brighten lights, Press & Hold 100% DIM^ until the lights have increased to the desired level.
NOTE: It is normal to observe a small dim spot on the LED at the location where the LED joins together.
TURNING THE APPLIANCE OFF
- Using the Remote Control, press on the desired Heater setting:
- Heater OFF – Heater off.
- Using the Remote Control, select the desired Light setting:
- Lights OFF (DIM^) – Light off.
REMOTE CONTROL BATTERY
-
CAUTION: Do not ingest battery—Chemical burn hazard.
-
The remote control supplied with this product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death.
-
Keep new and used batteries away from children.
-
If the battery compartment does not close securely, stop using the product and keep it away from children.
-
If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention and call a doctor.
-
Explosion hazard if the battery is substituted incorrectly.
-
Replace the battery with a CR2430 type battery only.
-
Battery is not rechargable and must not be recharged.
-
Always wrap the battery up, both when it is being stored and when it is being disposed of. The battery should not come into contact with other metal objects as it could cause the battery to run down, catch fire or be damaged.
-
Dispose of damaged or finished batteries immediately in compliance with the law. To this end, contact the authorities for safeguarding the environment or the centre for disposing of waste materials in your area.
-
Do not throw the battery away with household rubbish.
-
The supply terminals are not to be short-circuited.
-
Battery must be inserted with correct polarity (+/-)!
To replace the battery:- Remove screw and open the back cover of the remote.
- Take the old battery out and put the new one in the same way.
DANGER
ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Do not touch any
components other than specified below. Protective equiment including insulated
gloves must be worn.
-
Open cover to the Pendant Control Box, by removing 6x Oval head screws (#4-40 – Length: 1/2”) from the cover.
-
Switch the power supply to the Eclipse Pendant Control ON.
-
With the Eclipse Pendant Control powered ON,
PRESS & HOLD the middle ‘MEM’ button on the large heater control PCB. (A long “Beep” sound should be heard whilst the button is held down).
Whilst the ‘MEM’ button is held down, SHORT PRESS the Heater 100% button on the remote control. (Three short “Beep” sounds should be heard to indicate the remote has been paired successfully. -
Refit cover to the box, ensuring the 6 X M3 O-Rings are present on the 6x Oval head screws (#4-40 – Length: 1/2”).
PAIRING REMOTE CONTROL TO LED PCB (BOTTOM 3 BUTTONS OF REMOTE).
WARNING: MUST ONLY BE SERVICED BY LICENSED & AUTHORIZED TECHNICIAN.
DANGER
ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Do not touch any
components other than specified below. Protective equiment including insulated
gloves must be worn.
-
Open cover to the Pendant Control Box, by removing 6x Oval head screws (#4-40 – Length: 1/2”) from the cover.
-
Locate the small black button on the small LED PCB (shown in image on right), and the small button mid way down the back face of the remote (for later steps).
-
Switch the power supply to the Eclipse Pendant Control ON.
-
Using a thin item (e.g. paper clip/needle), SHORT PRESS the small button on the rear of the remote.
Within 5 seconds of pressing the small button on the rear of the remote, press the small black button on the LED PCB 3 times, holding the button down on the third press. (2X SHORT PRESS followed by 1X PRESS & HOLD) -
The LED on the Heater head will flash 3 times to indicate the remote is paired.
-
Refit cover to the box, ensuring the 6 X M3 O-Rings are present on the 6x Oval head screws (#4-40 – Length: 1/2”).
MAINTENANCE & SERVICING
IMPORTANT NOTES & WARNINGS
WARNING
This heater MUST be installed by an authorised/ licenced person. Do not
perform maintenance, or carry out installation or assembly procedure while
electrical power is switched on.
DANGER
ELECTRICAL SHOCK HAZARD! Serious injury or death may occur. Disconnect from
electrical supply before installing or servicing this heater. Read and follow
installation clearance requirements outlined in this manual. The appliance
MUST be connected to a properly grounded electrical source. Isolate mains
before installing. Use only with a properly secured heater.
IMPORTANT
Check product label for correct voltage and wattage to ensure power source
conforms to
the heater’s requirements.
Make all connections in accordance with local electrical code regulations. For
outdoor installation, all connections must be made in accordance with local
electrical code
regulations for outdoor wiring.
OVERCURRENT DEVICE: The outputs are NOT protected against short circuits or
extra-currents which can damage the electronic board. Evaluate the
characteristics of the
connected loads and apply the appropriate safety devices to the power line.
Check surrounding area of heater for hazards before turning on.
MAINTENANCE
- For longest product life, and to maintain product appearance, mount heater under cover and protect from rain and weather whenever possible.
- Before cleaning ensure the appliance is off and has been off for at least 2 hours after operation. The heater must be cool to touch before cleaning can begin.
- The exterior housing of the heater should be cleaned regularly. Use a clean, soft, damp cloth. Salt in the air can cause rusting of metal, especially at locations near the coast. Additional cleaning of the heater with a soft damp cloth fortnightly will aid in maintaining the product’s appearance. Do not clean heater with cleaners that are combustible or corrosive.
- Improper cleaning of the front of the appliance can cause scratching and reduce the appearance of the appliance. Below guidelines must be read before cleaning the front of the appliance and must be followed to maintain the quality of the surface finish.
DO NOT | DO |
---|
Do not use harsh cleaning pads or sharp tools. Do not use harsh cleaning chemicals.
Do not spray the appliance with water for cleaning.
| Use a clean, soft, damp microfibre cloth.
Use lukewarm water and a mild dish washing deter- gent.
Do not use a dry cloth or your hand to wipe clean the surface.
Using a dry cloth or your hand to clean the surface will rub dirt and dust into the surface and may cause scratching or damage.
| Use a microfibre cloth in the lukewarm water solution. Rinse out the cloth
frequently to remove any dirt and dust from the cloth to avoid scratching the
surface.
Do not apply pressure and rub the surface. Do not apply continuous, erratic
scrubbing.| Gently wipe the microfibre cloth across the surface. Apply minimum
pressure to avoid scratching.
Minimise contact with the surface.
Use the same directional stroke, lift hand and repeat.
Do not buff dry with a cloth that could cause scratching.| Allow surface to air dry.
TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE (S) | CORRECTIVE ACTION |
---|---|---|
No heat | 1. Incorrect heater setting chosen |
2. Incorrect Voltage.
3. No power.
4. No/low batteries in remote.
5. Remote too far.
6. Radio interference.
7. Remote not paired or faulty control.
| 1. Choose heat setting using remote (33%, 66% or 100%).
2. Connect to 220-240V power supply.
3. Check connection to power supply.
4. Change remote batteries.
5. Move remote closer to heater.
6. Move remote closer to heater, disable other radio emitting devices.
7. Pair remote to heater PCB.
Not enough heat| 1. Incorrect heater setting chosen.
2. Heater installed too high.
3. Heater too small for application.
| 1. Choose higher heat setting using remote (66% or 100%).
2. Check height is according to instructions.
3. Add additional heater(s).
Too much heat| 1. Incorrect heater setting chosen.
2. Heater installed too low.
| 1. Choose lower heat setting using remote (66% or 33%).
2. Check height is according to instructions.
No Light| 1. Incorrect lighting setting chosen.
2. Incorrect Voltage.
3. No power.
4. No/low batteries in remote.
5. Remote too far.
6. Radio interference.
7. Remote not paired or faulty control.
| 1. Choose lighting setting using remote (50% or 100% (DIM^)).
2. Connect to 220-240V power supply.
3. Check connection to power supply.
4. Change remote batteries.
5. Move remote closer to heater.
6. Move remote closer to heater, disable other radio emitting devices.
7. Pair remote to LED PCB.
Not enough Light| 1. Incorrect lighting setting chosen.
2. Light too small for application.
| 1. Choose higher lighting setting
using remote (50% or 100% (DIM^)).
2. Add additional light(s).
Too much Light| 1. Incorrect lighting setting chosen.| 1. Choose lower heat setting
using remote (50% or OFF (DIM^)).
REPLACEMENT PARTS
Part Number | Description | Part Number | Description |
---|---|---|---|
2620621-1 | Eclipse Electric Heater Head (AU) | 2620636 | Wall Mount Pole Elcipse |
Electric
2620631| Straight Ceiling Mount Pole 203mm Elcipse Electric| 2620637-1|
Eclipse Electric Pendant Control (AU)
2620632| Straight Ceiling Mount Pole 610mm Elcipse Electric| 2620659| Screw
Set Ceiling Mount Pole Eclipse Electric
2620633| Twin Straight Ceiling Mount Pole 610mm Elcipse Electric| 2620660|
Screw Set Wall Mount Pole Eclipse Electric
2620634| Curved Ceiling Mount Pole 610mm Elcipse Electric| 2620661| Remote for
Eclipse Electric Control (AU)
2620635| Straight Ceiling Mount Pole 1219mm Elcipse Electric| –| –
References
- Luxury Commercial & Residential Outdoor Heaters | Bromic Heating USA
- Luxury Commercial & Residential Outdoor Heaters | Bromic Heating USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>