infinity series EC-i Waterproof Panic Button Owner’s Manual
- June 10, 2024
- infinity series
Table of Contents
infinity panic
Waterproof Panic Button for ESL, ESX, EC-i & infinity output
Specifications
Operation | 1 Programmable Button |
---|---|
Wireless Range | Up t o 500m Line of Sight |
Frequency | SI6MHz |
Modulation Type | GFSK |
Protocol | infinity 2 Way Encrypted |
Indication | Haptic & LED Feedback |
Battery Type | 1x CR2032 Lithium (non replaceable) |
Battery Life | Up t o 5 Years |
Operating Temperature | -20°C t o 60°C |
Environment Humidity | 100% max |
Dimensions | 48mm x 44mm x 17mm |
Ingress Protection | P67 |
Functions | Programmable Arm, Disarm, Panic, Output Control & Delayed Press |
Options
Overview
Function
Automatically pairs to ‘infinity link’ or ‘infinity output’ during learn
procedure.
Optional ‘Delayed Press’ Function to help prevent false pressing. See bottom
of page for more information:
2 Way Feedback
Panic button will vibrate & displayagreen LEDto, indicate a successful control
panel or infinity Output operation.
Accessories
ClipinBase
With screw holes for wall mount or covert applications.
Nylon Necklace
For medical & other emergency applications.
Wrist Option
Locations For watch strap.
(Strap not included.
Requires 18mm x 1.5mm ‘single pass’ Strap).
Default Programming
If the ‘infinity panic’ has been previously learnt into a system it will
require defaulting before being learnt or re-learnt into a control panel or
infinity output.
- To default: Press & hold the button for 10 seconds ( until the LED turns SOLID RED).
- As soon as the LED is SOLID RED, release the button, then press the same button 5 times in quick succession. (The LED will Fast flash orange during this part of the process).
- A GREEN LED will flash momentarily to confirm that the default has completed successfully.
Button Delay Options
The infinity panic can be programmed for ‘Instant Press’, ‘O.2sec Delay’ or
‘O.5sec Delay’ as detailed below:
Warning: Changing the function will not work if the remote is
communicating with a control panel or ‘infinity output’. Make sure the remote
is defaulted OR temporarily disconnect the ‘infinity link’ before proceeding.
- To change the button delay time: Press & hold the button For 5 seconds ( u n t i l the LED rapidly flashes RED).
- Assoon as the LED is rapidly flashing RED, release the button, then press the same button 5 times in quick succession. (The LED will fast flash orange during this part of the process).
- A GREEN LED will flash momentarily t o confirm that the default has completed successfully.
The moment that the function has changed the infinity panic will vibrate to indicate the new function as detailed below:
1 Vibration = 0.2sec Delay 2 Vibrations = O.5sec Delay 3 Vibrations = Instant Press
Learning into the ESL Contro! Panel (consult contro! panel installation
manual for advanced programming)
ESL control panels have pre configured user slots to simplify the learning of
wireless buttons/users.
These are located from users 4O to 89 as shown in ‘Pre-Configured ser Slots’
table below:
-
Make sure you are in installer programming mode (default PROG OOO000 ENTER) before continuing.
-
Press PROG 18 ENTER followed by the User Number you wish to learn, then ENTER. Next press
ENTER again to start the Reypad beeps, indicating that the system is waiting to learn a remote button. -
Press the remote button you wish to learn and the Reypad should stop beeping, indicating a successful learn.
-
To learn another button, press the right or left arrows on the Reypad to go to next or previous user slot, then press ENTER, or press PROG then ENTER to exit installer programming.
Pre-Configured User Slots Table ( for ESL Series only)
Arm
Users 40 – 49| Users 40 to 49 will ARM only
Example: P18 E4OEE (learn beeps start) Press the remote button you wish to
learn (learn beeps stop)
This button will now ARM the system
---|---
Disarm
Users 50 – 59| Users 50 to 59 will DISARM only
Example: P18 E5QOEE (learn beeps start ) Press the remote button you wish to
learn ( learn beeps stop)
This button will now DISARM the system
Output 3
Users 60- 69| Users 60 to 69 will operate OUTPUT 3 & DISARM at the same time
Example: P18 E6QEE (learn beeps start ) Press the remote button you wish to
learn (learn beeps stop)
This button will now DISARM the system & control output 3 at the same time
Output 4
Users 70- 79| Users 70 to 79 will operate OUTPUT 4 & DISARM at the same time
Example: P18E 70OEE (learn beeps start ) Press the remote button you wish to
learn (learn beeps stop)
This button will now DISARM the system & control output 4 at the same time
Panic
Users 80- 789| Users 80 to 89 will operate as a PANIC button
Example: P18 E8OEE (learn beeps start ) Press the remote button you wish to
learn ( learn beeps stop)
This button will now perform a PANIC function
Battery Low Reporting & Haptic Feedback
- P7Emust be set t o option | (Freelink) to enable battery low reporting & For the remote t o operate correctly.
- Haptic feedback is disabled when battery is low is reported due t o the remote entering power save mode.
- Battery low will be indicated at 2.2V & under
Manufactured by Arrowhead Alarm Products Ltd – www.aap.co.nz
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>