Autonics SFN Series Safety Non Contact Door Switch Instruction Manual

October 29, 2023
Autonics

Autonics SFN Series Safety Non Contact Door Switch Instruction Manual

Thank you for choosing our Autonics product.

Read and understand the instruction manual and manual thoroughly before using the product. For your safety, read and follow the below safety considerations before using. For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website. Keep this instruction manual in a place where you can find easily. The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice. Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazar
  • symbol indicates caution due to special circumstances in which hazards may occur.

Warning Failure to follow instructions may result in serious injury or death .

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, )
  2. System manager means followings;
    • a personnel who is fully aware of installation, setting, operation, and maintenance of the product
    • a personnel who well observes standard/regulation/statute on the product by type of machine the product installed in and nation/region the product used in Machine user means a personnel who is appropriately trained about using machine by the system manager, so that machine user can operate the machine correctly. System manager has duty to train the machine user a bout operation of the product. Machine user has to report directly to the system manager when unusual status has been found while system is operating. Failure to follow this instruction may result in personal injury, economic loss or fire.
  3. The product has to be installed, set, and combined with machine control system by the qualified system manager. Failure to follow this instruction may result in personal injury due to unintended operation and unstable detection.
  4. Before using the product, check that function of the product operates as intended while machine is turned off after installation. Failure to follow this instruction may result in personal injury due to unintended operation and unstable detection.
  5. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, salinity, moisture, or steam, or dust may be present Failure to follow this instruction may result in explosion or fire.
  6. Do not disassemble or modify the unit Failure to follow this instruction may result in personal injury or fire due to loss of safety function.
  7. Do not defeat, tamper, modify, or bypass the switch and enter the door. Failure to follow this instruction may result in personal injury.
  8. Check whether machine is stopped or not when the door is opened. Failure to follow this instruction may result in personal injury.
  9. Check the installed status of the switch, operating status of the switch, and signs of damage, modification, tampering of the switch at the following situation and on a weekly basis.
    • when operating the safety system at first
    • when replacing component of the system
    • when the system has not been operated for a long time Failure to follow this instruction may result in personal injury due to malfunction of the product and safety function.
  10. Do not connect, repair, inspect, or replace the unit while connected to a power source. Failure to follow this instruction may result in fire.
  11. Check ‘Connections’ before wiring. Failure to follow this instruction may result in fire.
  12. Keep away from high voltage lines or power lines to prevent surge and inductive noise, and make cable as short as possible. In case installing power line and input signal line closely, use line filter or varistor at power line and shielded wire at input signal line. Do not use near the equipment which generates strong magnetic force or high frequency noise. Failure to follow this instruction may result in personal injury due to malfunction of the product and safety function.

Caution: Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications. Failure to follow this instruction may result in fire or product damage.
  2. Use a dry cloth to clean the unit, and do not use water or organic solvent. Failure to follow this instruction may result in fire.
  3. Make cable as short as possible, and keep the length of the cable within 100m when extent the length of the cable. Failure to follow this instruction may result in malfunction of the product and safety function due to surge.
  4. When wiring two or more products in series, keep the total length of the cable within 100m. Failure to follow this instruction may result in malfunction of the safety function due to voltage drop.
  5. When installing two or more product adjacently, give at least 26mm interval. Failure to follow this instruction may result in malfunction due to mutual interference.
  6. Do not install the switch and actuator on the magnetic object. Use bolt and nut of stainless steel or non-magnetic material, when installing the switch and actuator. Failure to follow this instruction may result in malfunction or affect sensing distance.
  7. Do not use the switch as a guard door stopper. Install separate mechanical stopper. Failure to follow this instruction may result in product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’ Otherwise, it may cause unexpected accidents.

  • Use the switch with the dedicated actuator and controller. Do not use the switch with another actuator or controller randomly. The switch is cannot be used without the controller (SFC-N322).

  • Power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.

  • When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between OV and F.G. terminal to remove noise.

  • This unit may be used in the following environments.

    • Indoors (UL Type 1 Enclosure)
    • Altitude max. 2,000 m – Pollution degree 3
    • Installation category II
  • Install the unit correctly with the usage environment, location, and the designated specifications.

  • When installing the product, tightening the screw of M4 x 20 mm with the tightening torque of 0.8N.m.

  • Installing more than 2 non-contact door switches closely may result in malfunction due to mutual interference.

  • Do not impact on the switch and excessively bend the cables.

  • Install the switch to the sensing surface of the switch and the actuator be exactly parallel.
    Cautions During Installation

  • Install the switch to the direction as below with the consideration of moving directions of the actuator.
    Cautions During Installation

  • Install the switch and actuator with a gap of minimum 1mm between them.

  • Install the switch at the adjoining wall of the guard door and the actuator at guard door.
    Cautions During Installation

Ordering Information

This is only for reference. For Selecting the specified model Follow the Autonics website.
Ordering Information

Cable
020: cable type (2 m)
050: cable type (5 m)
W: cable connector type

Product Components

  • Product
  • Instruction Manual

Sold Separately

  • Connector cable: C1D5-❑, CID5-❑, CID5-❑P
  • Branch connector CCDS-SFN, CYDS-SFN
  • Loop connector: CNDS-SFN
  • Safety controller non-contact door switch unit: SFC-N322

Specification

Model SFN-M-□
Operating distance 01) OFF→ON
ON→OFF ≤ 15 mm
Approval
Unit weight (packaged) Cable type (2 m): ≈ 100.5 g (≈ 113.8 g) Cable type (5

m): ≈ 199.5 g (≈ 214.8 g) Cable connector type: ≈ 58.1 g (≈ 71.6 g)
Power supply| 24 VDCᜡ (± 10 %)
Operating frequency| 100 Hz
Power consumption 01)| ≤ 0.8 W
Auxiliary output| PNP open collector output – 24 VDCᜡ, 10 mA
Operation indicator| ON: green, OFF: red
Life expectancy| ≥ 20,000,000 times (with low load)
Insulation resistance| ≥ 50 MΩ (500 VDCᜡ megger)
Protection circuit| Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit
Dielectric strength| 1,500 VACᜠ 50/60Hz for 1 minute
Vibration| 1.0 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Vibration (malfunction)| 1.0 mm amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 10 min
Shock| 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (malfunction)| 300m/s2 (≈ 30G) in each X, Y, Z direction in output ON/OFF status for 3 times
Ambient temperature| -10 to 55 ℃, storage : -20 to 60 ℃ (no freezing or condensation)
Ambient humidity| 35 to 85 %RH, storage : 35 to 85 %RH (no freezing or condensation)
Protection structure| IP67 (IEC standard)
Connection| Cable type / cable connector type model
Cable| Ø 5 mm, 5-wire, cable type: 2 m / 5 m, cable connector type: 0.3 m
Wire| AWG26 (0.08 mm), 28-core, core diameter: Ø 0.74 mm
Connector spec.| M12 plug connector
Material| Body/CAP: PC

It is rated at 23’C al ambient temperature. and it may be differed up to ± 20% by ambient temperature.
Power To the loads is not Included.

Safety status in case of error: the switch does not have an internal error recognition function, so it cannot maintain a safety status in the event of error. Error recognition is processed in the connected controller (SFC-N322).

Operation Distance

  • Operating distance represents the distance between the sensing surface of switch and that of actuator.
  • Operating distance can be differed according to the moving direction of actuator from the switch. (at ambient temperature of 23 °C)
  • The operating distance may be affected by metal or magnetic substances which is placed closely to the switch.
Operation Status Moving Direction Operation Distance
Off On Front Back ≥ 5 mm
Top Bottom ≥ 2 mm
Left Right ≥ 5 mm
Off On Front Back ≤ 15 mm
Top Bottom ≥ 6 mm
Left Right ≤ 15 mm

Connections

Signal Function Pin Color Controller
Power input VCC 1 Brown D3
GND 3 Blue D4
Signal input IN 2 White Dl
Signal output OUT 4 Black D2
Auxiliary output AUX 5 Yellow
  • M 12 connector pin arrangement

Connection Example

Cable Type

Wiring A single Switch
Connection Example

Wiring multiple switches
Connection Example

Cable Connector Type

Wiring A single Switch

Branch connector (CCD5-SFN), loop connector (CND5-SFN), AUX

**Wiring multiple Switches
Connection Example

_Branch connector (CYD5-SFN), loop connector (CN D5-SFN)
Connection Example_**

Maximum 30 unit of switches can be connected to a controller (SFC-N322).

Dimensions

  • Unit mm, For the Detailed drawings , follow the Autonics website.

Cable Type
Cable Type

Cable connector type
Cable connector tyoe

Costumer Support

18, Bansong-ro 5138eon-gl,
Haeundae-gu, Busan,
Republic of Korea, 48002
wwewautonics.com |
+82-2-2048-1577 |
sales@autonics.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Autonics User Manuals

Related Manuals