PENTAIR B-A1 Hydromatic Submersible Sump Pump Owner’s Manual

June 10, 2024
Pentair

PENTAIR-logo

PENTAIR B-A1 Hydromatic Submersible Sump Pump

General Information:
The B-A1 & BV-A1 Submersible Sump Pump are capable of handling 1/4 solids at 3450 RPM with a 1-1/2 NPT discharge and built-in overload protection. The pump is equipped with automatic operation through either a wide-angle float switch or vertical float switch.

California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects, or other  reproductive harm.

Pump Troubleshooting

  • Pump does not run or hum: Check the line
    circuit breaker, fuse, and water level in the sump. Ensure that the pump cord is making contact in the receptacle and that the float is not stuck. If all systems check out, the motor winding may be open.

  • Pump runs but does not deliver water: Check if
    the valve is installed correctly. If the float is stuck in an up  position, make sure it operates freely in the basin.

  • Pump runs and pumps out sump but does not
    stop:
    Ensure that the float is not stuck in an up position and that it operates freely in the basin.

  • Pump runs but delivers only a small amount of
    water:
    Check if the pump is air-locked and remove any clogs in the inlet holes, impeller, or volute openings.

  • Fuse blows or circuit breaker trips when pump
    starts:
    Remove any clogs in the inlet holes, impeller, or volute openings. Ensure that the fuse size or circuit breaker is at least 15 amps.

  • Motor runs for a short time, then stops:
    Remove any clogs in the inlet holes, impeller, or volute openings. Check if the motor stator is defective or if the pump impeller is clogged with tar or paint.

Product Usage Instructions:

The B-A1 & BV-A1 Submersible Sump Pump can be installed in a 12-inch diameter plastic, fiberglass, or concrete basin for vertical fits and an 18-inch diameter plastic, fiberglass, or concrete basin for wide-angle fits. Install the pump in the basin with a minimum height of 4 feet for the ground type 115-volt receptacle. The discharge piping can be PVC or ABS plastic with proper adapters or galvanized steel. Drill a 1/8 inch diameter hole in the discharge pipe below the check valve to prevent air locking. Use a lifting handle to move the pump when necessary. Install a check valve with rubber sleeve connectors for 1-1/4 and 1-1/2 pipe and a shut-off gate valve (optional).

General Information

Thank you for purchasing your Hydromatic® pump. To help ensure years of trouble-free op er a tion, please read the fol low ing manual carefully.

Before Operation:
Read the following in struc-tions care ful ly. Reasonable care and safe meth ods should be practiced. Check local codes and requirements before installation. Attention:
This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for con tin ued safe product use. DO NOT THROW AWAY OR LOSE THIS MAN U AL.

Warning: Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump. California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

Pump Troubleshooting

Pump does not run or hum

  1. Line circuit breaker may be off, or fuse may be blown or loose.
  2. Water level in sump may be too low. Add more water. Turn-on level is as indicated in installation drawing.
  3. Pump cord may not be making contact in receptacle.
  4. Float may be stuck. It should operate freely in basin.
  5. If all systems check OK, motor winding may be open.

Pump runs but does not deliver water

  1. Check valve may be installed backward. Arrow on valve should point in direction of flow.
  2. Discharge shut-off valve (if used) may be closed.
  3. Pump may be air locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in discharge.
  4. Impeller or volute openings may be fully or partially clogged. Remove pump and clean.
  5. Inlet holes in pump base may be clogged. Remove pump and clean the openings.
  6. Pump head may be too high. Pump can’t deliver water over 22 feet vertical. Horizontal distance does not affect pumping, except loss due to friction.

Pump runs and pumps out sump but does not stop
Float is stuck in up position. Be sure float operates freely in basin.

Pump runs but delivers only a small amount of water

  1. Pump may be air locked. Start and stop several times by plugging and unplugging cord. Check for clogged vent hole in discharge.
  2. Pump head may be too high. Pump can’t deliver water over 22 feet vertical. Horizontal distance does not affect pumping except loss due to friction.
  3. Inlet holes in pump base may be clogged. Remove pump and clean the openings.
  4. Impeller or volute openings may be fully or partially clogged. Remove pump and clean.
  5. Pump impeller may be partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean.

Fuse blows or circuit breaker trips when pump starts

  1. Inlet holes in pump base may be clogged. Remove pump and clean the openings.
  2. Pump impeller may be partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean.
  3. Motor stator may be defective.
  4. Fuse size or circuit breaker may be too small. Must be 15 amps.
  5. Impeller or volute openings may be wholly or partially clogged. Remove pump and clean.

Motor runs for a short time, then stops

  1. Inlet holes in pump base may be clogged. Remove pump and clean the openings.
  2. Impeller or volute openings may be wholly or partially clogged. Remove pump and clean.
  3. Motor stator may be defective.
  4. Pump impeller may be partially clogged with tar or paint, causing motor to run slow and overload. Remove pump and clean.

PENTAIR-B-A1-Hydromatic-Submersible-Sump-Pump-fig-1 PENTAIR-B-A1-Hydromatic-Submersible-Sump-Pump-
fig-2

Limited Warranty

HYDROMATIC warrants to the original consumer purchaser (“Purchaser” or “You”) of HYDROMATIC Sump Pumps, Effluent Pumps, Sewage Pumps (other than 2-1/2”), and Package Systems, that they will be free from defects in material and workmanship for the Warranty Period of 36 months from date of manufacture.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products (at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump Pumps, Filtered Effluent Pumps, Grinder Pumps, and 2-1/2” Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture, whichever comes first.

HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.