PENTAIR HP33 Submersible Sump Effluent Pump Installation Guide
- June 10, 2024
- Pentair
Table of Contents
PENTAIR HP33 Submersible Sump Effluent Pump
Product Information
The Submersible Sump Pumps are designed for home sumps. The unit is equipped with a 3-prong grounding-type power cord. The shaded-pole motor is oil filled and sealed for cooler running. Upper sleeve/lower ball bearing on the motor shaft never need lubrication. Automatic reset thermal protection.
Specifications
Power supply required ………………………………… 115V, 60 HZ.
Liquid Temp. Range ……………………. 32°F to 130°F (0°-54°C)
Individual Branch Circuit Required:……………………… 15 Amps
Discharge ……………………………………………………..1-1/2” NPT
Model Number| Motor HP| Full Load Amps| Individual Branch Circuit Required
(Amps)| Cord Length
---|---|---|---|---
HP33| 1/3| 9.8| 15| 10′
HP33-20| 1/3| 9.8| 15| 20′
HP33-30| 1/3| 9.8| 15| 30′
HP50| 1/2| 12.0| 15| 10′
HP50-20| 1/2| 12.0| 15| 20′
HP50-30| 1/2| 12.0| 15| 30′
The performance of the product is as follows:
Model| GPM (LPM) AT TOTAL FEET (m)| CAPACITY GALLONS(L)/MINUTE| No flow at
height shown below
---|---|---|---
HP33| 5 (19)| 48 (182)| 24 Ft. (7.3m)
| 10 (38)| 40 (151)|
| 15 (57)| 29 (110)|
| 20 (76)| 15 (57)|
HP50| 5 (19)| 62 (235)| 32 Ft. (9.8m)
| 10 (38)| 53 (201)|
| 15 (57)| 46 (174)|
| 20 (76)| 38 (144)|
| 25 (95)| 29 (110)|
Product Usage Instructions
Before using the product, carefully read and follow all safety
instructions in this manual or on the pump. The product is designed
for use in home sumps.
- Disconnect the power before servicing.
- Release all pressure within the system before servicing any component.
- Drain all water from the system before servicing.
- Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.
- Check the hoses for weak or worn conditions before each use. Make certain all connections are secure.
- Periodically inspect the sump, pump, and system components. Keep free of debris and foreign objects. Perform routine maintenance as required.
- Provide a means of pressure relief for pumps whose discharge line can be shut off or obstructed.
If you encounter any problems with the sump pump, please refer to the Troubleshooting Chart in this manual for information about common sump pump problems and remedies. For more information, see your dealer.
SAFETY INFORMATION
Carefully read and follow all safety instructions in this manual or on pump.
This is the safety alert symbol. When you see this symbol on your pump or in
this manual, look for one of the following signal words and be alert to the
potential for personal injury!
Danger! warns about hazards that will cause serious personal injury,
death or major property damage if ignored.
Warning! warns about hazards that can cause serious personal injury,
death or major property damage if ignored.
Caution! warns about hazards that will or can cause minor personal injury
or property damage if ignored.
The word NOTICE indicates special instructions which are important but not
related to hazards.
California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
DESCRIPTION
These Submersible Sump Pumps are designed for home sumps. The unit is equipped with a 3-prong grounding-type power cord. The shaded-pole motor is oil filled and sealed for cooler running. Upper sleeve/lower ballbearing on the motor shaft never need lubrication. Automatic reset thermal protection.
GENERAL SAFETY INFORMATION
Electrically powered sump pumps normally give many years of trouble-free service when correctly installed, maintained, and used. However, unusual circumstances (interruption of power to the pump, dirt/debris in the sump, flooding that exceeds the pump’s capacity, electrical or mechanical failure in the pump, etc.) may prevent your pump from functioning normally. To prevent possible water damage due to flooding, consult your dealer about installing a secondary sump pump, a DC backup sump pump, and/or a high water alarm. See the “Troubleshooting Chart” in this manual for information about common sump pump problems and remedies. For more infor-mation, see your dealer.
-
Know the pump application, limitations, and potential hazards.
-
Disconnect the power before servicing.
-
Release all pressure within the system before servicing any component.
-
Drain all water from the system before servicing.
-
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing per-sonal injury and/or property damage.
-
Check the hoses for a weak or worn condition before each use. Make certain all connections are secure.
-
Periodically inspect the sump, pump and system compo-nents. Keep free of debris and foreign objects. Perform routine maintenance as required.
-
Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed.
-
Personal Safety:
- Wear safety glasses at all times when working with pumps.
- Keep the work area clean, uncluttered and properly lighted – replace all unused tools and equipment.
- Keep visitors at a safe distance from work area.
- Make the workshop child-proof – with padlocks, mas-ter switches, and by removing starter keys.
-
When wiring an electrically driven pump, follow all electri-cal and safety codes that apply.
-
This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3-conduc-tor cord and 3-prong, grounding-type plug.
Warning: Electrical shock hazard. Can burn or kill. To reduce risk of electric shock, pull plug before servic-ing. Pump is supplied with a grounding conductor and grounding-type attachment plug. Be sure it is connected only to a properly grounded grounding-type receptacle.
Where a 2-prong wall receptacle is encountered, it must be replaced with a properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.
This pump has not been investigated for use in swimming pool areas. -
All wiring should be performed by a qualified electrician. Make certain the power source conforms to the require-ments of your equipment.
-
Protect the electrical cord from sharp objects, hot sur-faces, oil, and chemicals. Avoid kinking the cord. Replace or repair damaged or worn cords immediately.
-
Do not touch an operating motor. Motors can operate at high temperatures.
-
Do not handle the pump or pump motor with wet hands or when standing on wet or damp surface, or in water.
Warning: Electrical shock hazard.
Can burn or kill. If your basement has water or moisture on floor, do not walk on wet area until all power has been turned off. If shut-off box is in basement, call electric company or hydro authority to shut-off service to house, or call your local fire department for instructions. Remove pump and repair or re place. Failure to follow this warning can result in fatal electrical shock. -
Pump water only with this pump. Do not use with salt water or brine.
-
Do not install the pump in any location classified as hazardous by the National Electric Code, ANSI/NFPA 70- 2011 or the Canadian Electrical Code.
INSTALLATION
-
Install the pump in a sump pit with a minimum diameter of 11” (279mm). The sump depth should be 20” minimum (381mm). Construct the sump pit of tile, concrete, steel or plastic. Check the local codes for approved materials.
-
Adjust the float stop on the rod to adjust the pump “ON” point. “OFF” point is factory preset.
-
The pump should not be installed on clay, earth or sand surfaces. Clean the sump pit of small stones and gravel which could clog the pump. Keep the pump inlet screen clear.
-
Install the pump in the pit so that the switch operating mechanism has maximum possible clearance.
-
Install the discharge plumbing. When using rigid pipe, use plastic pipe. Wrap the threads with PTFE pipe thread sealant tape. Screw the pipe into the pump hand tight plus 1 to 1-1/2 turns.
NOTICE: Do not use ordinary pipe joint compound on plastic pipe. Pipe joint compound can attack plastics and damage the pump.
Caution: Risk of flooding. If a flexible discharge hose is used, make sure the pump is secure in the sump to prevent movement. Failure to secure the pump may allow pump movement, switch interference and prevent the pump from starting or stopping. -
To reduce motor noise and vibrations, a short length of rubber hose (e.g. radiator hose) can be connected into the discharge line near the pump using suitable clamps.
-
Install an in-line check valve to prevent backward flow through the pump when the pump shuts off.
-
Power Supply: The pump is designed for 115 V., 60 Hz., operation and requires a minimum 15 amp individual branch circuit. The pump is supplied with a 3-wire cord set with grounding-type plug. Do not modify cord or plug. Be sure it is connected only to a properly grounded grounding-type receptacle.
NOTICE: All installations where a sump pump is permanently-wired to the source of electrical supply
(control device or junction box) must be performed only by qualified personnel using the appropriate tools, skills, and knowledge of electrical safety. Such a connection would not be considered readily removable if the plug were cut off the pump’s power cord. Questions relating to this type of installation should be directed to your local code authority.
Warning: Hazardous voltage. Can shock, burn or kill. The pump should always be electrically grounded to a suitable electrical ground such as a grounded water pipe or a properly grounded metallic raceway, or ground wire system. Do not modify the cord or plug or cut off the round ground pin. -
If the pump discharge line is exposed to an outside sub-freezing atmosphere, the portion of the line exposed must be installed so any water remaining in the pipe will drain to the outfall by gravity. Failure to do this can cause the water trapped in the discharge to freeze which could result in damage to the pump.
-
After the piping and check valve have been installed, the unit is ready for operation.
-
Check the operation by filling the sump with water and observing pump operation through one complete cycle.
Warning: Risk of Flooding. Failure to make this operational check may lead to improper operation, premature failure, and flooding.
OPERATION / MAINTENANCE
Warning: Risk of electrical shock. Can burn or cause death. Do not handle
a pump or pump motor with wet hands or when standing on a wet or damp surface,
or in water.
Before attempting to check why unit has stopped operating, disconnect power
from unit.
Warning: Risk of fire and explosion. Can cause severe injury, property
damage or death. Do not use in explosive atmospheres. Pump water only with
this pump.
- The shaft seal depends on water for lubrication and cooling. Do not operate the pump unless it is submerged in water as the seal may be damaged if allowed to run dry.
- The motor is equipped with an automatic reset thermal protector. If the temperature in the motor should rise unduly, the switch will cut off all power before damage can be done to the motor. When the motor has cooled sufficiently, the switch will reset automatically and restart the motor. If the protector trips repeatedly, the pump should be removed and checked as to cause of difficulty. Low voltage, long extension cords, clogged impeller, very low head or lift, etc., could cause cycling.
- The pump will not remove all water. If a pump is operating and suddenly no water comes out of the discharge hose, shut the unit off immediately. The water level is probably very low and the unit has broken prime.
SWITCH REPLACEMENT
-
Disconnect power to the pump.
-
Remove the pump from the sump. If it is in effluent service, disinfect it for one hour with chlorine bleach. Wear rubber gloves when handling the pump.
-
Remove the bottom tether strap from the float rod, lift the float and swing it sideways, and remove it from the switch arm.
-
Remove the four screws that secure the switch to the top of the motor housing and lift the switch off the motor. The switch guard may come off with it.
-
Disconnect four wires that connect the switch to the motor housing.
-
Remove and discard the gasket between the switch and the pump. Clean the gasket surface on the motor housing.
-
Set the new gasket on the motor housing, then connect the four wires on the new switch to the four terminals in the motor housing (see Figure 1, page 4). Do not disturb the two spade terminals on the switch!
NOTICE: When you connect the two power wires to the cord terminals, make sure that the wire ends don’t lodge between the cord pin and the side of the cord plug. The connector must be on the pin. -
With the switch guard in place, set the switch on the motor housing with the switch arm pointed toward the discharge side of the pump and install and tighten the four screws which secure the switch to the pump.
-
Holding the float out sideways, hook the float rod on to the switch arm and swing the float rod down.
-
Insert the float rod in the hole in the tether strap.
-
Reinstall the pump in the sump, check all piping connections, and reconnect the power. Run the pump through one complete operating cycle to check for proper operation. Failure to make this operational check may lead to flooding and will void the warranty.
AIRLOCKS
When a pump airlocks, it runs but does not move any water. An airlock will
cause the pump to overheat and fail. These pumps have a built in anti-airlock
hole. See the exploded view on the repair parts page for the location of the
hole. Leakage from the anti-airlock hole is normal.
If you suspect an airlock, unplug the pump, clean out the anti-airlock hole
with a paper clip or a piece of wire, and restart the pump.
TROUBLESHOOTING CHART
SYMPTOM | PROBAB l E CAuSE(S) | CORRECTIVE ACTION |
---|---|---|
Pump won’t start | Blown fuse. | If blown, replace with a fuse of proper size. |
or run. | Low line voltage. | If the voltage is under the recommended minimum, |
check the size of the wiring from the main switch on the property. If OK,
contact power company or hydro authority.
| Defective motor.| Replace the pump.
| Defective float switch.| Replace the float switch.
| Impeller.| If the impeller won’t turn, remove the lower pump body and locate
the source of the binding.
| Float is obstructed.| Remove the obstruction.
Pump starts and stops too often.| Backflow of water from piping.
Faulty float switch.
| Install or replace the check valve.
Replace the float switch.
Pump won’t shut off.| Defective float switch. Restricted discharge (obstacle in piping).
Float obstructed.
| Replace the float switch.
Remove the pump and clean the pump and piping.
Remove the obstruction.
Pump operates but delivers little or no water.| Low line voltage.| If the
voltage is under the recommended minimum, check the size of the wiring from
the main switch on the property. If OK, contact the power company or hydro
authority.
| Something is caught in the impeller.| Clean out the impeller.
| Anti-airlock hole is plugged.| Turn off the pump, clean out the anti-airlock
hole, and restart the pump.
REPAIR PARTS
key No.|
Description
|
Qty.
|
HP33
|
HP50
---|---|---|---|---
1| Switch Kit| 1| PS17-1550REP| PS17-1550REP
2| Gasket Kit (Includes O-Rings and Gaskets, Key Nos. 2A,2B, 2C)| 1|
U9-471REP| U9-471REP
3| Power Cord 10’| 1| PW117-237-TSU| PW117-237-TSU
| Power Cord 20’| 1| PW17-122| PW17-122
| Power Cord 30’| 1| PW17-293| PW17-293
4| Motor| 1| |
5| Shaft Seal| 1| 21607A001| 21607A001
6| Impeller| 1| PS5-26P| PS5-29P
7| Lower Volute| 1| PS1-34P| PS1-34P
8| Suction Plate| 1| U43-142SS| U43-142SS
9| Switch Float Kit (Includes Float, Switch Rod, Rod Stops and| 1| PS28-37REP|
PS28-37REP
| Tether Strap)| | |
Limited Warranty
HYDROMATIC warrants to the original consumer purchaser (“Purchaser” or
“You”) of HYDROMATIC Sump Pumps,
Effluent Pumps, Sewage Pumps (other than 2-1/2”), and Package Systems, that
they will be free from defects in material and workmanship for the Warranty
Period of 36 months from date of manufacture.
Our warranty will not apply to any product that, in our sole judgment, has
been subject to negligence, misapplication, improper installation, or improper
maintenance. Without limiting the foregoing, operating a three-phase motor
with single-phase power through a phase converter will void the warranty. Note
also that three-phase motors must be protected by three-leg, ambient
compensated, extra-quick trip overload relays of the recommended size or the
warranty is void.
Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or
replace defective products (at HYDROMATIC’s choice). You must pay all labor
and shipping charges associated with this warranty and must request warranty
service through the installing dealer as soon as a problem is discovered. No
request for service will be accepted if received after the Warranty Period has
expired. This warranty is not transferable.
EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump Pumps,
Filtered Effluent Pumps, Grinder Pumps, and 2-1/2” Sewage Pumps are warranted
for a period of 12 months from date of purchase or 18 months from date of
manufacture, whichever comes first.
HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR
CONTINGENT
DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND
THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on the duration of an implied warranty,
so the above limitations or exclusions may not apply to You. This warranty
gives You specific legal rights and You may also have other rights which vary
from state to state.
This Limited Warranty is effective June 1, 2011, and replaces all updated
warranties and warranties dated before June 1, 2011.
HYDROMATIC
293 Wright Street, Delavan, WI 53115
Phone: 888-957-8677 • Fax:
800-426-9446 • Web Site:
hydromatic.com