The Battery Backup System is a pre-plumbed kit that includes a primary sump pump (PSP), backup sump pump (BSP) assembly, and a vertical float switch. The unit comes equipped with two check valves, one for the primary pump and one for the backup pump. This system is designed to temporarily backup your primary sump pump during a power outage or other problem which prevents normal operation of the primary pump. It is not a substitute for your primary sump pump. The system is designed for residential use only and should not be used to pump flammable liquids or chemicals.

Important Safety Instructions

This manual contains important safety instructions that should be followed during installation, operation, and maintenance of the  product. The following signal words indicate the potential for personal injury:

  • Danger: indicates a hazard which, if not avoided, will result in death or serious injury.
  • Warning: indicates a hazard which, if not avoided, can result in death or serious injury.
  • Caution: indicates a hazard which, if not avoided, can or may result in minor or moderate injury.
  • Notice: addresses practices not related to personal injury.

It is important to carefully read and follow all safety instructions in this manual and on pumps. Keep safety labels in good condition and replace missing or damaged safety labels. Battery acid is corrosive, so do not spill it on skin, clothing, or battery charger. Wear eye and head protection when working with battery. Connect and disconnect DC output terminals only after removing the charger from the AC outlet. Never allow the DC terminals to touch each other. Do not run the pump dry as it can damage seals and cause leaking and property damage. Do not lift the pump by the electrical cord; lift the pump only by the discharge pipe, lifting ring, or handle on the pump. Pump clear water only with this pump.

Product Usage Instructions

To use the Battery Backup System, follow these steps:

  1. Make sure the system is installed properly according to the instructions provided in the manual.
  2. Ensure that the system is connected to a battery backup power source.
  3. During a power outage or other problem that prevents normal operation of the primary sump pump, the backup sump pump will activate and begin pumping water out of the sump pit.
  4. Once power is restored and the primary sump pump is operational again, the backup sump pump will shut off automatically.
  5. Regularly check and maintain the system according to the instructions provided in the manual to ensure optimal performance and prevent potential hazards.

Safety

Important Safety Instructions
SAVE THESE INSTRUCTIONS – This manual contains important instructions that should be followed during installation, operation, and maintenance of the product.
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!
DANGER indicates a hazard which, if not avoided, will result in death or serious injury.
WARNIG indicates a hazard which, if not avoided, can result in death or serious injury.
CAUTION indicates a hazard which, if not avoided,
WARNING can or may result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Carefully read and follow all safety instructions in this manual and on pumps.
Keep safety labels in good condition. Replace missing or damaged safety labels.
Battery acid is corrosive. Do not spill on skin, clothing, or battery charger. Wear eye and head protection when working with battery. Connect and disconnect DC output terminals only after removing the charger from the AC outlet. Never allow the DC terminals to touch each other.
Hazardous Voltage. Can cause severe or fatal electrical shock. Do not plug in or unplug battery charger while standing on a wet floor or in water. Be sure one hand is free when plugging in or unplugging charger. If basement floor is wet, disconnect power to basement before walking on floor. If shut-off box is in basement, call electric company or hydro authority to shut-off service to house, or call your local fire department for instructions. Remove pump and repair or re place. Failure to follow this warning can result in fatal electrical shock. Risk of flooding. Do not run pump dry. To do so will damage seals and can cause leaking and property damage.
Risk of electrical shock. Do not lift the pump by the electrical cord; lift pump only by the discharge pipe, lifting ring or handle on the pump. Lifting by the cord can damage the cord.

California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

  1. Know the pump application, limitations, and potential hazards.

  2. Do not use in water with fish present. If any oil leaks out of the motor it can kill fish.
    NOTICE This unit is not designed as a waterfall or fountain pump, or for applications involving salt water or brine! Use with waterfalls, fountains, salt water or brine will void warranty.

  3. Disconnect power before servicing.

  4. Drain all water from system before servicing.

  5. Secure discharge line before starting pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage.

  6. Check hoses for weak or worn condition before each use, making certain that all connections are secure.

  7. Periodically inspect sump, pump and system components. Keep free of debris and foreign objects. Perform routine maintenance as required.

  8. Provide means of pressure relief for pumps whose discharge line can be shut-off or obstructed. Release all pressure within system before servicing any component.

  9. Personal Safety:

    • Wear safety glasses at all times when working with pumps.
    • Keep work area clean, uncluttered and properly lighted – replace all unused tools and equipment.
    • Keep visitors at a safe distance from work area.
    • Make workshop child-proof – with padlocks, master switches, and by removing starter keys.
  10. Follow local and/or national plumbing and electrical codes when installing the system. A ground fault circuit interrupter (GFCI) is recommended for use on any electrical appliance submerged in water.

  11. All wiring should be performed by a qualified electrician.

  12. This equipment is only for use on 115 volt (single phase) and is equipped with an approved 3- conductor cord and 3-prong, grounding-type plug.

  13. Where a 2-prong wall receptacle is encountered, it must be replaced with properly grounded 3-prong receptacle installed in accordance with codes and ordinances that apply.

  14. Make certain power source conforms to requirements of your equipment.

  15. Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking cord. Replace or repair damaged or worn cords immediately.

  16. Do not touch an operating motor. Modern motors can operate at high temperatures.

  17. Pump clear water only with this pump.

  18. Pump is permanently lubricated at the factory. Do not try to lubricate it!

  19. This pump is designed for use in a residential sump only.

GENERAL INFORMATION
The Battery Backup Combo Kit is pre-plumbed up to the hose and clamp assembly. The system includes the primary sump pump (PSP), backup sump pump (BSP) assembly, and vertical float switch. The unit is equipped with two check valves – one for the primary pump and one for the backup pump.
The battery backup pump is not a substitute for your primary sump pump. It is designed to temporarily backup your primary sump pump during a power outage or other problem which prevents normal operation of the primary pump. Do not use this system to pump flammable liquids or chemicals. Pump clear sump water only with this pump. For residential use only.
Keep the battery charger dry and protected from damage.
This system is designed to work with either a sealed lead-acid AGM battery or a flooded lead-acid battery. Use of a true Gel Cell (often confused for AGM) or a standard automotive battery with this charger is not recommended. An automotive battery may require charging after only 1-2 hours of continuous use, and the repeated charging cycles may cause early plate failure in the battery.

Specifications

Maximum vertical pumping distance is 13.35 feet (3.4M) for Model FG-2200C.
Power supply required

  • Primary Sump Pump……………………..115V, 60 HZ.
  • Backup Sump Pump……………………12V DC Battery
  • Liquid Temp. Range……………………..32°F to 70°F(0°-21°C)
  • Individual Branch Circuit Required (min.)………….15 Amps

Discharge:

  • Hose & Clamp Assembly……….1-1/4”Slip / 1-1/2”Slip
  • Minimum pit diameter …………………………………………….14”
  • Minimum depth………………………………………………………10”

NOTICE Do not reduce size of discharge pipe or hose below 1-1/4” diameter. If discharge is too small, pump will overheat and fail prematurely.
NOTICE: If a Carbon Monoxide (CO) sensor is installed, it must be at least 15 feet away from battery charger  in order to avoid nuisance CO alarms. Please refer to your CO detector’s installation guidelines for more information.

Performance – Primary

GPM (LPM) at total feet (m) of lift

Series| HP| 5 (1.5m)| 10 (3m)| 15 (4.6m)| 20 (6.1m)| MAX. LIFT
Capacity Gallons(L)/Minute
Primary (HS33V1)| 1/3| 53

(201)

| 45

(170)

| 36

(136)

| 24

(91)

| 25ft (7.6m)

Performance – Backup

GPM (LPM) at total feet (m) of lift

Series| 0

(0)

| 5 (1.5m)| 10 (2.5m)| MAX. LIFT
Capacity Gallons(L)/Minute
Backup (PS17-118)| 34

(129)

| 23

(87)

| 10

(38)

| 13.35 ft (3.4m)

Electrical & Switch Specifications

Series| HP| Motor Full Load Amps| Branch Circuit Req. (Amps)| Switch Setting in inches (cm)
---|---|---|---|---
On| Off
HS33V1| 1/3| 3.9| 15| 7.5
(19.1)| 3
(7.6)
PS17-118| –| –| 10.5
(26.7)| 25 sec.

Required Battery Capacity:
For best results, use the following AGM Storage Batteries:

Part| Amp- Hour| Gal/Charge at 10’| Approx Run Time
---|---|---|---
BAT40| 40| 3000| 4.5 Hours
BAT75| 75| 7000| 10.3 Hours

  • Unit equipped with dual battery capability
  • Maximum amp-hour: 120
  • 38-120 Ampere-Hour Storage or Deep Cycle Battery

Pump Installation

Backup Assembly Installation
Attach backup pump assembly to primary pump. To do so, un-screw bottom nut on check valve and remove rubber seal. Place nut from check valve around discharge PVC pipe on primary pump, then place rubber seal. Attach backup pump assembly to the primary pump by tightening nut to the rest of the check valve unit. Adjust backup pump to sit at an angle (approx. 10°).

Float Switch Installation
Assemble float switch as shown.

Combo Unit Installation
Suggested Materials Needed:
Screwdriver, tape measure, hacksaw, cable ties

  1. Drain the sump pit as far as possible without running the pump dry. Do this by:

    •  Piggyback switch: Unplug the pump and switch from the outlet, then unplug the pump from the piggyback switch. Reset the circuit breaker or reinstall the fuse and plug the pump directly into the outlet. The pump will start. Drain the pit and unplug the pump. OR
    • No piggyback switch: Reset the circuit breaker or reinstall the fuse and use a non-conducting broom handle or stick to raise the float switch; the pump should start. Drain the pit and then release the switch.
    • When the pit has drained, turn off (open) the circuit breaker or remove the fuse again to avoid electrical shock while working on the installation. Unplug existing sump pump and place power cord and piggyback switch out of the way of work and water.
  2. Measure height of FG-2200C Combo Kit from base to top of hose clamp assembly. Subtract 1”.
    Drop the tape measure into the bottom of sump pit and mark the cut line on the discharge pipe (1” less than total height of the Combo Kit).

  3. Use hacksaw to cut horizontally along cut line completely through pipe.
    NOTICE Depending on where your current check valve is located, there may be excess water. Let the water drain/drip into the sump pit.

  4. Remove old sump from sump pit.
    NOTICE Remove all sand, clay, and gravel before installing.

  5. Place Combo Kit into sump pit. Make sure vertical float switches can operate freely inside sump pit.

  6. Once the Combo Kit is firmly seated in the base of the pit, connect the hose and clamp switch to the existing discharge pipe and clamp it securely.

  7. Secure power cord & BSP), piggyback switch, and reed switch high up and around pipe with  a cable tie. Plug the primary pump into a standard household 15 amp outlet.
    NOTICE The circuit should be dedicated to the sump pump exclusively.
    Remember: Do not handle the pump while it is plugged in; whether it is running or not.

  8. Connect BBU. See “BBU Wiring and Setup”.

  9. Once all wiring is complete, fill your pit with water and verify that the PSP removes the water and the BBU doesn’t run. Then, unplug your PSP and refill your pit with water. Verify that the BBU removes the water.

  10. Make sure that the power is on to both pumps, and  your system is ready to use.

Operation
Risk of electric shock. Can shock, burn or kill. Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface, or in water.

  1. Shaft seal depends on water for lubrication. Do not operate pump unless it is submerged in water as seal may be damaged if allowed to run dry.
  2. Motor is equipped with automatic reset thermal protector. If temperature in motor should rise, switch will cut off all power before damage can be done to motor. When motor has cooled, switch will reset automatically and restart motor. If protector trips repeatedly, pump should be removed and checked. Low voltage, long extension cords, clogged impeller, very low head or lift, or a plugged or frozen discharge pipe, etc., could cause cycling.
  3. Pump will not remove all water. If operating a pump manually and suddenly no water comes out of the discharge hose, shut off the unit immediately. The unit has broken prime due to a very low water level.

Risk of electric shock. Can shock, burn or kill. Before attempting to check why unit has stopped operating, disconnect power from unit.

BBU Wiring and Setup

  1. Connect the positive (+) charger/controller lead wire (red) to the positive (+) battery terminal (red). Connect the negative (–) charger/controller lead wire (black) to the negative (–) terminal (black) on the battery. If you are using two batteries, use the set of optional terminals and connect the second battery. Use lead wires (not included) to connect the positive (+) charger/controller terminal to the positive (+) battery terminal and the negative (–) charger/controller terminal to the negative (–) battery terminal.

  2. The backup pump leads are polarity sensitive; connect the positive pump lead to the terminal labeled Pump ‘+’ and the negative pump lead to the terminal labeled Pump ‘–’.
    NOTICE: If the leads are reversed, the pump will run backward and not pump water.

  3. The float switch leads are not polarity sensitive; connect the float switch leads to the ‘Float Switch’ tabs on the charger/controller.

  4. Test the float and the pump by lifting and holding the float. The ‘PUMP STATUS’ LED will light continuously and the buzzer will beep steadily. The pump should start after 3 seconds. If the pump does not run, check all the connections and remake them as necessary.

  5. To stop the pump, lower the float; after 25 seconds the pump should stop, the ‘PUMP STATUS’ LED should flash, and the buzzer should beep.

  6. With the pump operating, test the ‘SILENCED ALARM’ button; hold for one second; release.
    The ‘SILENCED AUDIBLE ALARM’ LED should illuminate and the buzzer should stop sounding. To reset the buzzer (allow it to sound) and extinguish the ‘SILENCED AUDIBLE ALARM’ LED, press the ‘SILENCE ALARM’ button again for one second. Depress the ‘SYSTEM TEST’ button; hold it for one second; release. The ‘PUMP STATUS’ LED should stop flashing.
    NOTICE: During normal operation, the flashing  ‘PUMP STATUS’ LED indicates that the pump has run in your absence.

  7. Press and hold ‘SYSTEM TEST’ button. All LEDs will light up, pump will run and buzzer will sound. Release the button and LEDs should go off, pump should stop, buzzer should stop.

  8. The ‘BATTERY STATUS’ LED indicates the battery capacity when the A.C. power is off.

    • Continuously ON – the battery voltage is above 10.9 Volts Direct Current (10.9VDC) and capacity is above 20%.
    • Slow Beep/Slow LED Flash – the battery’s capacity is between 0 and 20%.
    • Fast Beep/Fast LED Flash – the battery is severely discharged. The battery will continue to charge (as long as the 115V AC power to the charger is on) at the rate of .5 AH until the battery’s charge is above 20%.
      When the first warning occurs (slow beep/slow flash), you will have approximately 2 hours (or less) of pump operation left. The actual time of operation will depend on the condition of the battery and may be as little as 15 minutes.
  9. Connect the Power Supply cable (supplied) to the Charger/Controller’s Power Input jack.

PENTAIR-FG-2200-Classic-Battery-Backup-Systems-7

LED Display and Control Buttons

PENTAIR-FG-2200-Classic-Battery-Backup-Systems-8

NOTICE: When the unit is first plugged in, or when it first receives power from the battery, the ‘BATTERY STATUS’ LED will flash for 3 seconds.
NOTICE: To activate any Control Button, press and hold it for 1 second.

Battery Requirements

Hazardous electric current. Can cause severe burns and start a fire if the battery terminals are short circuited. Install the battery in the battery case. To prevent accidental shorting across battery terminals, close and latch the battery case securely. Do not leave the battery uncovered.
Do not allow children to play around the battery backup system installation.
The performance of your backup sump pump depends on the battery used with it for power. We recommend using our BAT40 or BAT75. You can also use a group 24M or 27M Deep Cycle battery. They will provide acceptable performance and will stand up well to long periods of little or no use.
This system is designed to work with either a sealed lead-acid AGM battery or a flooded lead-acid battery. Use of a true Gell Cell (often confused for AGM) or
a standard automotive battery with this charger is not recommended. An automotive battery may require charging after only 1-2 hours of continuous use, and the repeated charging cycles may cause early plate failure in the battery.
Use only lead-acid batteries. This unit is not designed to use with Li-Ion, NiMh, NiCAD, Liquid Polymer, etc.
Use only the recommended battery or one of the same type and size so it will fit in the battery box (maximum size: 13” long x 7” wide x 10” tall (330.2mm x 177.8mm x 254mm) including terminals) and supply enough voltage for full performance.

BATTERY MAINTENANCE
Severe burn hazard. An acid-filled standard lead-acid battery contains sulfuric acid. Avoid contact with skin, eyes or clothing.
NOTICE: To protect the battery case from chipping and gouging, do not let the battery sit on a concrete floor. Install the battery on a shelf or protective pad (plywood, 2x4s, etc.). Always install the battery in a dry location that is protected from flooding.

Pre-Qualification Test – 1 and 2
Charger is charging at a very low level to try to bring a dead battery back to life. If the battery is taking too long, try resetting the charger once or twice (push the ‘SYSTEM TEST’ and ‘SILENCE ALARM’ buttons together to reset the charger).

Special Features:
The charger is equipped with reverse battery, short circuit, and “runaway charge” protection.

Possible Problems and Remedies

  1. Wrong Battery Voltage
    Reconnect charger to a 12 volt battery.

  2. Reversed Battery Connections
    Check all connections. The negative (black) on the battery must connect to the negative (black) on the charger, and the positive (red) on the battery must connect to the positive (red) on the charger. Reversing the battery connections will cause the ‘SYSTEM ALERT’ and ‘SILENCED AUDIBLE ALARM’ LEDs to flash.

  3. Thermal Runaway Condition
    “Thermal Runaway” is the technical term for the condition of the battery when some (or all) of the cells have deteriorated to the point that they won’t take a charge. In this case, replace the battery.

  4. Charge Time Monitor – 1 and 2
    Battery took too long to complete its charge. The “Charge Time Monitor” will shut down the charger after 84 hours of continuous charging.
    Possible causes are:

    • Pump ran for a long period of time during charging, or
    • Battery is too large for the charger (including several batteries connected in a parallel circuit).

Excessive Battery Drain
Pump may have run for a very long time, discharging the battery. In this case:

  • If 115VAC power is OFF, the charger shuts down until the power comes back on, but the pump will run as long as the battery charge lasts. You may need to replace the battery afterwards.

  • If 115VAC power is ON, the charger/controller continues to try to charge the battery at a charging rate of .5 AH until the battery charge is more
    than 20%, at which point the charger will resume charging at a rate of 2 AH.

  • If the pump is running and the AC power is on, you may need to stop the pump to allow the battery to charge.

Follow the battery manufacturer’s recommendations for maintenance and safe use of the battery.

LED Display

TABLE II – Operating Code Displays (LEDs Lighted Continuously or Flashing)

PENTAIR-FG-2200-Classic-Battery-Backup-Systems-9

NOTICE: All of the situations listed above indicate normal system operation; no action is required. However, if the BBIJ pump is running or has run, check the primary pump and actively monitor the charger status for battery life. Always reset the charger after the pump runs. During normal system operation, the ‘SYSTEM ALERT’ LED does not light up. The “AC POWER” LED is lighted as long as the system is plugged in to an operating AC power circuit.

Control LED:| Continuous Illumination Indicates Normal Operation:
---|---
AC Power| AC power is present.
Pump Status| The float switch has been activated. The LED remains on (flashing) after the pump has stopped. Depress the ‘SYSTEM TEST’ button to reset it.
Silenced Audible Alarm| Audible Alarm has been silenced. Press and release the ‘SILENCE ALARM’ button to reset (activate) the audible alarm and turn OFF the LED.
Charging| Indicates that the battery is charging – see Table II, above.
Battery Status| A. Continuous ON – the battery voltage is above 10.9 Volts DC and capacity is above 20%.
B. Slow Beep/Slow LED Flash – the battery’s capacity is below 20%, and voltage is between 8.2VDC and 10.9VDC.
C. Fast Beep/Fast LED Flash – the battery has been discharged to less than 8.2VDC.
System Alert| Flashing (in unison with the buzzer) indicates that the charger has entered ‘Failure Mode’. Press the ‘SYSTEM TEST’ and ‘SILENCE ALARM’ buttons to reset it.

NOTICE : If the source of the failure is not corrected, the charger will reenter “Failure Mode”. See Table IV for error code information.

TABLE IV – Error Code Displays (LEDs Flashing)

PENTAIR-FG-2200-Classic-Battery-Backup-Systems-10

Control Button: Result of Pushing Button:
System Test Pump starts and all LEDs light up.

Will reset the ‘PUMP STATUS’ LED.
When pushed with the ‘SILENCE ALARM’ button, the Charger/Controller microprocessor resets and error code resets.
Silence Alarm| Toggle; Prevents the audible alarm sounding. Press and release to reset.
Light| Toggles the flood light on the Charger/Controller on and off.
System Reset| Press and release ‘SYSTEM TEST’ and ‘SILENCE ALARM’ to reset system.

Troubleshooting

PRIMARY PUMP TROUBLESHOOTING

Symptom Possible Cause(s) Corrective Action



Pump won’t start or run.

| Pump is not plugged in.| Check and see if pump is plugged into a proper outlet.
Blown fuse.| If blown, replace with fuse of proper size.
Low line voltage| If voltage under recommended minimum, check size of wiring from main switch on property. If OK, contact power company or hydro authority.
Defective motor.| Replace pump.
Defective float switch.| Replace float switch.
Impeller| If impeller won’t turn, remove lower pump body and locate source of binding.
Float obstructed| Remove obstruction.
Pump starts and stops too often.| Backflow of water from piping| Install or replace check-valve.
Faulty float switch| Replace float switch.


Pump won’t shut off

| Defective float switch| Replace float switch.
Restricted discharge (obstacle or ice in piping)| Remove pump and clean pump and piping.
Float obstructed| Remove obstruction.
Restricted intake screen| Remove the pump and clean the intake screen and the impeller.





Pump operates but delivers little or no water

| Low line voltage| If voltage under recommended minimum, check size of wiring from main switch on property. If OK, contact power company or hydro authority.
Something caught in impeller| Remove the pump and clean out the impeller.
Worn or defective parts or plugged impeller| Clean impeller if plugged; otherwise replace pump.
Check valve installed without vent hole.| Drill a 1/16” – 1/8” (1.6mm-3.2mm) dia. hole between pump discharge & check valve (1-2” above where the discharge pipe screws into the pump discharge and below the waterline).
Restricted intake screen| Remove the pump and clean out the intake screen.
Check valve is installed either backward or upside down| ****

Be sure check valve is installed correctly.

BATTERY BACKUP SYSTEM TROUBLESHOOTING

Pump won’t run: Check all the wiring connections.

Check for a low or defective battery.
Check that the automatic switch is free to move up and down.
Press the circuit breaker reset button on the control panel.
Motor hums but pump won’t run:| Check for low or defective battery.
Pump runs but pumps very little or no water:| Make sure a check valve is installed and functioning between the primary pump discharge and the Battery Backup wye.
Check for an obstruction in the discharge pipe.
The discharge pipe length and/or height exceeds the capacity of the pump. See Table VI, Page 11, for pump capacity.
Check for a low or defective battery.
The Positive (+) and negative (–) pump wires are reversed. Disconnect them and reconnect correctly.
Pump cycles too frequently:| The check valve located between the discharge of the primary pump and the Battery Backup wye is not installed or is not working properly. Install an auxiliary check valve (see Pages 5 and 6) or replace the existing check valve as required.

Repair Parts – Primary Pump

Ref Description Qty HS33V1
1 Power Cord Assembly 1 PS117-54-TSU
2 Vertical Float Switch Assembly 1 FPS17-66
3 Motor 1 *
4 Upper Volute 1 PS1-324
5 Impeller 1 PS5-285
6 Lower Volute 1 PS1-326
7 Screw #8-32 x 1/2” 10
8 O-ring -162 Buna-N 5.75″ x 3/32″ 1 U9-470

*If motor fails, replace entire pump
Purchase locally

PENTAIR-FG-2200-Classic-Battery-Backup-Systems-12

key No. Part Description Part Number
1 DC Backup Pump PS17-118*
2 Float Switch PS17-2003
3 Charger/Controller PS217-1521
4 Battery Case (Complete) PS17-2044 PS17-2045
5 AC Adaptor PS17-2008
6 11” x .14” Plastic Cable Tie **
7 Backup Combo Plumbing Kit (with check valve) U137-692
  • If pump fails, replace entire system. ** Purchase separately.

Optional Batteries
Sold Separately

Part Description Part Number
AGM 75A-Hour BAT75
AGM 40A-Hour BAT40

Warranty

Retain Original Receipt for Warranty Eligibility

Limited Warranty
Hydromatic® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below.

Product Warranty Period

whichever occurs first:

  • Submersible utility pumps and related accessories 12 months from date of original installation, or 18 months from date of manufacture

  • Sump/Sewage/Effluent Products 12 months from date of original installation, or 36 months from date of manufacture

  • Battery Backup Units
    FG-2200, FG-2200C
    FG-3100, FG-3100C
    12 months from date of original installation,
    or 18 months from date of manufacture
    24 months from date of original installation,
    or 30 months from date of manufacture

  • Wastewater Solids Handling Pumps 12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.
Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products (at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.
HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.
This Limited Warranty is effective May 12, 2014 and replaces all undated warranties and warranties dated after May 12, 2014.
HYDROMATIC
293 Wright Street, Delavan, WI 53115
Phone: 888-957-8677 • Fax: 800-426-9446www.hydromatic.com
In Canada: 490 Pinebush Road, Unit 4, Cambridge, Ontario N1T 0A5
Phone: 800-363-7867 • Fax: 888-606-5484