Thank you for choosing our Au tonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using. For your safety, read and follow the considerations written in the instruction manual, other manuals and Au tonics website. Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice. Follow Au tonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • symbol indicates caution due to special circumstances in which hazards mayoccu

Warning Failure to follow instructions may result in serious injury or death.

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
    Failure to follow this instruction may result in personal injury, economic loss or fire.

  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
    Failure to follow this instruction may result in explosion or fire.

  3. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in fire.

  4. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in fire.

  5. Check ‘Connections’ before wiring.
    Failure to follow this instruction may result in fire.

Caution Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or product damage.

  2. Use a dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in fire.

Cautions during Use

  • Install the unit correctly with the usage environment, location, and the designated specifications.
  • Do NOT impacts with a hard object or excessive bending of the wire lead-out. It may cause damage the water resistance.
  • Do NOT pull the Ø 3.5 mm cable with a tensile strength of 25 N, the Ø 4 mm cable with a tensile strength of 30 N or over and the Ø 5 mm cable with a tensile strength of 50 N or over. It may result in fire due to the broken wire.
  • When extending wire, use AWG 22 cable or over within 200 m.

Ordering Information
This is only for reference, the actual product does not support all combo

Autonics CR30-15AO Cylindrical Capacitive Proximity Sensors -
Fig

  1. DIA. of sensing side
    Number: DIA. of sensing side (unit: mm)

  2. Sensing distance
    Number: Sensing distance (unit: mm)

  3. Control output
    O: Normally Open
    C: Normally Closed

Connections

  • LOAD can be wired to any direction.
  • Connect LOAD before suppling the power.

Operation Timing Chart

| Normally open| Normally closed
---|---|---
Sensing target| Presence
Nothing| Presence
Nothing
**Load| Operation
Return| Operation
Return
Operation indicator (red)**| ON
OFF| ON
OFF

Sold Separately

  • Connector cable, connector connection cable
  • Transmission coupler
  • Spatter protection cover
  • Fixed bracket

Grounding
The sensing distance will be changed by grounding status of capacity proximity sensor and the target [50 × 50 × 1 mm (iron)]. Check the material when installing the sensor
and selecting the target.
■ CR18-8A□

Ground condition (switch b) ON OFF
Operating distance (mm) 8 4

■ CR30-15A□

Ground condition Switch a ON OFF ON OFF
Switch b ON ON OFF OFF
Operating distance (mm) 15 18 6 6

Specifications

Installation Non-flush type
Model CR18-8A□
DIA. of sensing side Ø 18 mm
Sensing distance 8 mm
Setting distance 0 to 5.6 mm
Hysteresis ≤ 20 % of sensing distance
Standard sensing target: iron 50 × 50 × 1 mm
Response frequency 01) 20 Hz
Affection by temperature ≤ ± 20 % for sensing distance at ambient temperature

20 ℃
Indicator| Operation indicator (red)
Approval| ᜫ| ᜫ
Unit weight (package)| ≈ 70 g (≈ 82 g)| ≈ 200 g (≈ 237 g)

  1. The response frequency is the average value. The standard sensing target is used and the width is set as 2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
Power supply 100 -240 VACᜠ 50 / 60 Hz, operating voltage: 85 – 264 VACᜠ
Leakage current ≤ 2.2 mA
Control output ≤ 5 to 200 mA
Residual voltage ≤ 20 V
Protection circuit Surge protection circuit
Insulation resistance ≥ 50 MΩ (500 VDCᜡ megger)
Dielectric strength 1,500 VACᜠ 50 / 60Hz for 1 min (between all terminals and

case)
Vibration| 1 mm double amplitude at frequency 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock| 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times
Ambient temperature| -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
Ambient humidity| 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
Protection structure| DIA. of sensing side Ø 18 mm: IP66 (IEC standard) / DIA. of sensing side Ø 30 mm: IP65 (IEC standard)
Connection| Cable type
Cable spec.| DIA. of sensing side Ø 18 mm: Ø 4 mm, 2-wire, 2 m DIA. of sensing side Ø 30 mm: Ø 5 mm, 2-wire, 2 m
Wire spec.| AWG 22 (0.08 mm, 60-core), insulator DIA.: Ø 1.25 mm
Material| Standard type cable (black): polyvinyl chloride (PVC)
DIA. of sensing side Ø 18 mm| Case / Nut: PA6
DIA. of sensing side Ø 30 mm| Case / Nut: nickel-plated brass, washer: nickel- plated iron, sensing side: PBT

Sensitivity Adjustment

Please turn potation VR to set sensitivity as below procedure.

  • When there is distance fluctuation between proximity sensor and the target, please adjust 2 at the farthest distance from this unit.
  • Turning potent ion VR toward clockwise, it will be max., or turning toward counter clockwise, it will be min. The number of adjustment should be 15 ± 3 revolution and if it is turned to the right or left excessively, it will not stop, but it idles without breakdown.
  • ( ) is for Normally closed type.
Procedure Potent ion VR Description
1

Stop at ON (OFF) position

| Without a sensing object, turn the potent ion VR to the right and stop at the proximity sensor is ON (OFF).
2|

Stop at OFF (ON) position

| Put the object in right sensing position, turn the potention VR to the left and stop at the proximity sensor is OFF (ON).
3| | If the difference of the number of potention VR rotation between the ON (OFF) point and the OFF (ON) point is more than 1.5 turns, the sensing operation will be stable.
4| | If it is set in sensitivity adjustment position of potent ion VR at center between 1 and 2, sensitivity setting will be completed.

Cut-out Dimensions

  • Unit: mm, For the detailed drawings, follow the Au tonics web site.

| o 18 mm| o 30 mm
---|---|---
Mounting hole (H)| Ø 18.5 +0.50| Ø 30.5 +0.50
TAP| M18×1| M30×1.5

| o 18 mm| o 30 mm
---|---|---
o A| 26.5| 42
B| 24| 35

Mutual-interference & Influence by Surrounding Metals
■ Mutual-interference

When plural proximity sensors are mounted in a close row, malfunction of sensor may  be caused due to mutual interference.
Therefore, be sure to provide a minimum distance between the two sensors, as below table.

Autonics CR30-15AO Cylindrical Capacitive Proximity Sensors -
Fig10

■ Influence by surrounding metals
When sensors are mounted on metallic panel, it must be prevented sensors from being affected by any metallic object except target. Therefore, be sure to provide a minimum distance as below chart.

Sensing side/Item o 18 mm o 30 mm
A 48 90
B 54 90
20 10
o d 54 90
m 24 45
n 54 90

Tightening Torque

Use the provided washer to tighten the nuts.
The tightening torque of the nut varies with the distance from the fore-end. [Figure 1] If the nut tip is located at the front of the product, apply the front tightening torque the allowable tightening torque table is for inserting the washer as [Figure 2].

Autonics CR30-15AO Cylindrical Capacitive Proximity Sensors -
Fig11

Sensing side/Strength o 18 mm o 30 mm
Front size 12 mm
Front torque 0.39 N m 49 N m
Rear torque 0.39 N m 78.4 N m

18, Ban song 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577