**Autonics BS5 Series Groove Depth 9mm Photomicro Sensor
**
Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using
the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction
manual, other manuals and Autonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for
product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.
Safety Considerations
- Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
- symbol indicates caution due to special circumstances in which hazards may occur.
Warning: Failure to follow instructions may result in serious injury or death.
-
Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g., nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire or economic loss. -
Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or fire. -
Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire. -
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire. -
Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
Caution: Failure to follow instructions may result in injury or product damage.
-
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or shortening the life cycle of the product. -
Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire or electric shock.
Cautions during Use
- Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
- Use the product, 0.5 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
- 5-24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
- Wire as short as possible and keep away from high voltage lines or power lines, to prevent inductive noise.
- When using sensor with the equipment which generates noise (switching regulator, inverter, servo motor, etc.), ground F.G. terminal of the equipment.
- This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000m
- Pollution degree 2
- Installation category II
Ordering Information
This is only for reference, the actual product does not support all
combinations.
For selecting the specific model, follow the Autonics website.
Appearance+Connection
| Cable type| | Connector type
---|---|---|---
K1| | K2|
T1|
Distance from the center of sensing
to mounting surface: 7.3 mm| T2|
Distance from the center of sensing
to mounting surface: 7.3 mm
L1| | L2|
Y1| | Y2|
V1| | V2|
TA1|
Distance from the center of sensing
to mounting surface: 10 mm| TA2| Distance from the center of sensing
to mounting surface: 10 mm
F1| | F2|
R1| | R2|
Indicator
M: Turns ON under the light received condition
R: Turns ON under the light interrupted condition
Control output
No mark: NPN open collector output
P: PNP open collector output
Sold Separately
- Connector: CT-01 (connector type), CT-02 (cable type, length: 1 m)
Cautions for Installation
- Tighten the screw with tightening torque under 0.49 N m.
- In case of F and R type, as shown below, make sure that the bottom of the product and the mounting surface are in direct contact with each other
**Correct
Wrong
**
Connections
-
Cable type
-
Connector type
- For LOAD connection, follow the cable type connection.
- Be sure to connect the unit using the dedicated connector (CT-01 or CT-02, sold separately).
If it is soldered on the unit terminal pin directly not using the connector (CT-01), it may cause product damage.
Pin | Color | Function |
---|---|---|
1 | Brown | +V |
2 | White | Control |
3 | Black | Output |
4 | Blue | 0V |
- Selectable operation mode
Be sure to connect the control wire when selecting the operation mode.
Failure to this instruction may result in product damage.
Operation mode | Connection |
---|---|
Light ON | (White) Control wire connects with (Brown) +V |
Dark ON | (White) Control wire connects with (Blue) 0V |
Circuit
-
NPN open collector output
-
PNP open collector output
- OCP (over current protection), SCP (short circuit protection)
- If short-circuit the control output terminal or supply current over the rated specification, normal control signal is not output due to the protection circuit.
Operation Timing Chart
Model| Indicator turns ON under light received condition|
Indicator turns ON under light interrupted condition
---|---|---
Received light| |
Light ON| Operation indicator| |
| Transistor output| |
Dark ON| Operation indicator| |
| Transistor output| |
Specifications
Series | BS5 |
---|---|
Sensing type | Through-beam |
Sensing distance | 5 mm |
Sensing target | Opaque materials |
Min. sensing target | ≥ 0.8 mm × 2 mm |
Hysteresis | ≤ 0.05 mm |
Response time | Received light: ≤ 20 ㎲ , Interrupted light: ≤ 100 ㎲ |
Frequency response | 2 kHz 01) |
Light source | Infrared LED |
Peak emission wavelength | 940 nm |
Operation mode | Light ON-Dark ON selectable (control wire) |
Indicator | Operation indicator (red) |
Approval | |
Unit weight | Cable type: ≈ 50 g, Connector type: ≈ 30 g |
Response frequency is the value getting from revolving the circle panel below.
Power supply | 5-24 VDCᜡ ±10 % (ripple P-P: ≤ 10 %) |
---|---|
Current consumption | ≤ 30 mA |
Control output | NPN open collector / PNP open collector output model |
Load voltage | ≤ 30 VDCᜡ |
Load current | ≤ 100 mA |
Residual voltage | NPN: ≤ 1.2 VDCᜡ, PNP: ≤ 1.2 VDCᜡ |
Protection circuit | Reverse power polarity protection circuit, output short |
overcurrent protection circuit
Insulation resistance| ≥ 20 MΩ (250 VDCᜡ megger)
Noise immunity| The square wave noise (pulse width: 1㎲) by the noise simulator
± 240 VDCᜡ
Dielectric strength| 1,000 VACᜠ 50/60 Hz for 1 minute
Vibration| 1.5 mm double amplitude (max. acceleration 196 m/s2 ) at frequency
of 10 to 2,000 Hz in each X, Y, Z direction for 2 hours
Shock| 15,000 m/s2 (approx. 1,500 G) in each X, Y, Z direction for 3 times
Ambient illumination (receiver)| Fluorescent lamp: ≤ 1,000
Ambient temperature| -20 to 55 ℃, storage: -25 to 85 ℃ (no freezing or
condensation)
Ambient humidity| 35 to 85%RH, storage: 35 to 85%RH (no freezing or
condensation)
Protection rating| IP50 (IEC standard)
Connection method| Cable / Connector type model
Cable spec.| Ø 3 mm, 4-wire, 1 m
Wire spec.| AWG28 (0.08 mm, 19-core), insulator outer diameter: Ø 0.88 mm
Material| Case: PBT, Sensing part: PC
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com