Autonics BS5 Series Groove Depth 9mm Photomicro Sensor Instruction Manual

June 10, 2024
Autonics

**Autonics BS5 Series Groove Depth 9mm Photomicro Sensor

**

Autonics BS5 Series Groove Depth 9mm Photomicro Sensor

Thank you for choosing our Autonics product.

Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.

Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • symbol indicates caution due to special circumstances in which hazards may occur.

Warning: Failure to follow instructions may result in serious injury or death.

  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g., nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
    Failure to follow this instruction may result in personal injury, fire or economic loss.

  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
    Failure to follow this instruction may result in explosion or fire.

  3. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in fire.

  4. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in fire.

  5. Check ‘Connections’ before wiring.
    Failure to follow this instruction may result in fire.

Caution: Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or shortening the life cycle of the product.

  2. Use dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in fire or electric shock.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected accidents.
  • Use the product, 0.5 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  • 5-24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Wire as short as possible and keep away from high voltage lines or power lines, to prevent inductive noise.
  • When using sensor with the equipment which generates noise (switching regulator, inverter, servo motor, etc.), ground F.G. terminal of the equipment.
  • This unit may be used in the following environments.
    • Indoors (in the environment condition rated in ‘Specifications’)
    • Altitude max. 2,000m
    • Pollution degree 2
    • Installation category II

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specific model, follow the Autonics website.

Appearance+Connection

| Cable type| | Connector type
---|---|---|---
K1| | K2|
T1|
Distance from the center of sensing
to mounting surface: 7.3 mm| T2|
Distance from the center of sensing
to mounting surface: 7.3 mm
L1| | L2|
Y1| | Y2|
V1| | V2|
TA1|
Distance from the center of sensing
to mounting surface: 10 mm| TA2| Distance from the center of sensing
to mounting surface: 10 mm
F1| | F2|
R1| | R2|

Indicator

M: Turns ON under the light received condition
R: Turns ON under the light interrupted condition

Control output

No mark: NPN open collector output
P: PNP open collector output

Sold Separately

  • Connector: CT-01 (connector type), CT-02 (cable type, length: 1 m)

Cautions for Installation

  • Tighten the screw with tightening torque under 0.49 N m.
  • In case of F and R type, as shown below, make sure that the bottom of the product and the mounting surface are in direct contact with each other

**Correct

Wrong

**

Connections

  • Cable type
    Connections

  • Connector type

    • For LOAD connection, follow the cable type connection.
    • Be sure to connect the unit using the dedicated connector (CT-01 or CT-02, sold separately).
      If it is soldered on the unit terminal pin directly not using the connector (CT-01), it may cause product damage.
Pin Color Function
1 Brown +V
2 White Control
3 Black Output
4 Blue 0V
  • Selectable operation mode

Be sure to connect the control wire when selecting the operation mode.
Failure to this instruction may result in product damage.

Operation mode Connection
Light ON (White) Control wire connects with (Brown) +V
Dark ON (White) Control wire connects with (Blue) 0V

Circuit

  • NPN open collector output

  • PNP open collector output
    Circuit

    • OCP (over current protection), SCP (short circuit protection)
    • If short-circuit the control output terminal or supply current over the rated specification, normal control signal is not output due to the protection circuit.

Operation Timing Chart

Model| Indicator turns ON under light received condition| Indicator turns ON under light interrupted condition
---|---|---
Received light| Operation Timing Chart| Operation Timing
Chart
Light ON| Operation indicator| |
| Transistor output| |
Dark ON| Operation indicator| |
| Transistor output| |

Specifications

Series BS5
Sensing type Through-beam
Sensing distance 5 mm
Sensing target Opaque materials
Min. sensing target ≥ 0.8 mm × 2 mm
Hysteresis ≤ 0.05 mm
Response time Received light: ≤ 20 ㎲ , Interrupted light: ≤ 100 ㎲
Frequency response 2 kHz 01)
Light source Infrared LED
Peak emission wavelength 940 nm
Operation mode Light ON-Dark ON selectable (control wire)
Indicator Operation indicator (red)
Approval
Unit weight Cable type: ≈ 50 g, Connector type: ≈ 30 g

Response frequency is the value getting from revolving the circle panel below.
Diminsion

Power supply 5-24 VDCᜡ ±10 % (ripple P-P: ≤ 10 %)
Current consumption ≤ 30 mA
Control output NPN open collector / PNP open collector output model
Load voltage ≤ 30 VDCᜡ
Load current ≤ 100 mA
Residual voltage NPN: ≤ 1.2 VDCᜡ, PNP: ≤ 1.2 VDCᜡ
Protection circuit Reverse power polarity protection circuit, output short

overcurrent protection circuit
Insulation resistance| ≥ 20 MΩ (250 VDCᜡ megger)
Noise immunity| The square wave noise (pulse width: 1㎲) by the noise simulator ± 240 VDCᜡ
Dielectric strength| 1,000 VACᜠ 50/60 Hz for 1 minute
Vibration| 1.5 mm double amplitude (max. acceleration 196 m/s2 ) at frequency of 10 to 2,000 Hz in each X, Y, Z direction for 2 hours
Shock| 15,000 m/s2 (approx. 1,500 G) in each X, Y, Z direction for 3 times
Ambient illumination (receiver)| Fluorescent lamp: ≤ 1,000
Ambient temperature| -20 to 55 ℃, storage: -25 to 85 ℃ (no freezing or condensation)
Ambient humidity| 35 to 85%RH, storage: 35 to 85%RH (no freezing or condensation)
Protection rating| IP50 (IEC standard)
Connection method| Cable / Connector type model
Cable spec.| Ø 3 mm, 4-wire, 1 m
Wire spec.| AWG28 (0.08 mm, 19-core), insulator outer diameter: Ø 0.88 mm
Material| Case: PBT, Sensing part: PC

18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com
+82-2-2048-1577
sales@autonics.com