SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch User Manual

June 10, 2024
SEVECU

User manualSEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE
Switch SW2624POE-MGF-250
24 Port Gigabit Layer 2 PoE Switch

Installation manual introduction

The Product installation manual mainly describes PoE switch hardware features, installation methods, and precautions during the installation
This manual includes the following chapters:
Chapter 1: Product Introduction. Briefly describes the basic features,
Detailed hardware & software specifications of the switch and the appearance details.
Chapter 2: Product Installation. Guide the switch hardware installation methods and precautions.
Chapter 3: Hardware Connections. Guide the connection between switches and other devices and precautions.
Chapter 4: Packaging and product usage suggestions.

Chapter 1: Product Introduction

1.1 Products description
Device is managed PoE switch for security transmission and WIFI coverage, meet the need of PoE power supply for WIFI AP, IP-camera, WIFI bridge, IP phones and other types of equipment. New generation of high-performance hardware and software platforms are used, providing flexible, cost-effective full Gigabit access and uplink ports, complete security mechanisms, improved ACL / QoS strategy and rich VLAN capabilities. It is easy to manage and maintain, meet the users’ requirements for network equipment easy to manage, high security and low cost. Supporting Apollo Cloud One-stop Management Platform, realizing status checking and management monitoring functions, suitable for campus, Hotel and enterprise park network access, convergence, core multi-application scenarios
1.2 Product Features

  • Full Gigabit Port
    24 1000Mbps RJ45 ports (support PoE power supply) with 2 Gigabit SFP ports, Data transmission is not jammed.

  • Realtek chip, the performance is more stable and powerful
    Realtek high-performance chip can greatly improve network data processing rate

  • Convenient operation

    • AI VLAN mode: Separating 1-8 ports from each other, can effectively restrain network storm and improve network performance.
    • AI Extend mode: Designed for monitoring application scenarios, 1-8 ports support 250 meters long distance power supply.
    • AI PoE mode: automatically check, reboot the device while find it fake dead
    • AI QoS mode: video data first, more fluent transmission
  • Support Apollo Cloud Platform One-stop Management Support cloud platform for resource visualization management of switches and downloaded PD devices, make operation and maintenance management easy

1.3 product specification
Hardware Specifications

Chipset Realtek High Performance Chipset
Flash 16MB
RAM 128M DDR
Network IEEE 802.3i IEEE 802.3u IEEE 802.3x IEEE 802.3ab IEEE 802.3af IEEE

802.3at
Port| 2410/100/1000Mbps RJ45 ports
2 Gigabit SFP ports
1 Console port
PoE| 24 10/100Mbps RJ45 port support PoE+
Max 250W
Single port max 46W
LEDs| 26 Link/Act LEDs
24 POE LEDs
1 Power LED
1 SYS LED
Performance| Forwarding mode: store and forward
Performance| Switch Volume (Full-duplex) :52Gbps
---|---
Packet forwarding rate:38.688Mpps
8K MAC address table
lightning protection| ±6KV
ESD| No barrier: ±6KV Air:±8KV
Input| 100-240V/50-60Hz
Dimension

(L×W×H)

| 440mm×180mm×44mm

Software Specifications

Network standard| IEEE 802.3: Ethernet Media Access Control (MAC) protocol
IEEE 802.3i:10BASE-T Ethernet
IEEE 802.3u:100BASE-TX fast Ethernet IEEE 802.3ab:1000BASE-T gigabit Ethernet IEEE 802.3z:1000BASE-X gigabit Ethernet (fiber)
IEEE 802.3ad: comply link aggregation standard
IEEE 802.3x: flow control IEEE 802.1p: About the traffic priority of the
second layer of Qos / Cos protocol (multicast filtering)
IEEE 802.1q:VLAN Bridge operation IEEE 802.1d:STP spanning tree
IEEE 802.1s:MSTP spanning tree
IEEE 802.1w:RSTP spanning tree
---|---
| IEEE 802.3af
IEEE 802.3at
---|---
Shortcut function| One key VLAN
One key Exnted(1-8 port 250meters PoE distance)
One key QoS (Video priority)
One key AI power supply
DHCP| DHCP Snooping
VLAN| Support 4K VLAN
Support 802.1Q VLAN、Port VLAN、Voice VLAN
MAC address table| Comply the IEEE 802.1d standard
Support MAC address learning and aging automatically
Support static, dynamic, filter address table
Safety| Password protection
Support based on the port number, IP address, MAC address restrictions on user access
Support HTTPS、SSL V3、TLS V1、SSH V1/V2
Based on user rating management and password protection
Support IP-MAC-PORT
Safety| Support ARP protection, IP sources protection, DoS protection
---|---
Support DHCP Snooping、DHCP attack protection
Support 802.1X AAA
Support port security, port isolation
Support CPU protection
PoE| Support setting the PoE port priority
Support viewing POE Chip Status
Support setting PoE power supply period
Support setting port power
Access control (ACL)| Support L2(Layer 2)~L4(Layer 4) packet filtering function
Support port mirroring, port redirection, flow rate limit, QoS re-marking
QoS| Support 8 port queue
Support port priority, 802.1p priority, DSCP priority
Support SP、RR、WRR、WFQ Priority scheduling algorithm
Support automatically identify, manage and acquire of connected equipment
information
Multicast| Support IGMP v1/v2 Snooping
Support static multicast
Multicast| Support multicast VLAN
---|---
Support multicast filtering, message statistics, unknown multicast discarding
Spanning Tree| Support STP(IEEE 802.1d),RSTP(IEEE 802.1w) and MSTP(IEEE 802.1s) protocol
Support loop protection, BPDU protection
Storm suppression| Support for multicast suppression
Support broadcast suppression
Support for unknown unicast suppression
Link aggregation| Support static aggregation
Support dynamic aggregation
Support IP, MAC, hybrid load balancing mode
Supports up to 32 aggregation groups
IPv6| Support IPv6 Ping、IPv6 Tracert、IPv6 Telnet
| Support IPv6 SSH 、IPv6 SSL
Management and maintenance| Support WEB management(HTTP、HTTPS、SSL V3)
Support CLI(Telnet、SSH V1/V2,local serial port)
Support SNMP V1/V2/V3
Support LLDP、RMON
Management and maintenance| Support SNMP
---|---
Support ARP Protection, IP Source protection、DoS protection
Support CPU monitor、memory monitoring
Support system log
Support Ping, Tracert detect cable testing

1.4 Appearance
Front Panel
Including indicators, RJ45 port, DIP switch, RST button, SFP port, CONSOLE port, as shown belowSEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE
Switch - shown below

  • indicator
    The indicator working status is shown as the following table
    The indicator working status is shown as the following table
Indicators Title Color Work status Description
POWER Power indicator Red Solid Power is normal
Off No power, the power switch is not turned on, power supply is abnormal
POE POE power indicator Yellow Solid The corresponding RJ45 port is

connected to the powered device and the power supply is normal
Off| The corresponding RJ45 port is not connected to the powered device or the power supply is abnormal
LINK/ACT| Connection indicator| Green| Blinking| A valid link is established
Off| An invalid link is
| | | | established
---|---|---|---|---
SYS| System indicator| Green| Blinking| System is functioning properly
Off| System is functioning improperly Software is damaged

  • Shortcut button
    QOS: Improve video data processing capabilities and improve the monitoring of Caton and Mosaic phenomena in the network
    Extend: 1-8 port rate down to 10Mbps, but the transmission distance up to 250 meters
    VLAN: Isolating ports 1-8 from each other, suppress network storms effectively and improve network performance
    AI power supply: Detect PD, power failure and restart dead equipment

  • RJ45 Port
    Device with 16 10/100/1000Mbps PoE port, all port support IEEE802.3af and IEEE802.3at standard

  • SFP Port
    Device provides two Gigabit SFP optical module expansion slots (25,26), which can be inserted into Gigabit SFP module.

  • RST Button
    When the switch is powered on, press the button with the needle to release the device and enter the restarting state. When the SYS lamp restarts, the device restarts. When the switch is powered on, press and hold the button for more than 5s to release the button and enter the reset state. When SYS is re-lit, the device is reset successfully

  • Console port
    Console port used to connect to computer or other terminal to manage or configure the switch.
    Back Panel

  • Including: power socket, ground terminal

SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
1

  • Power socket
    A 100-240VAC 50/60 Hz power receptacle for accommodating the supplied power cord

  • Ground terminal
    Please use the grounding wire to prevent lightning. To avoid product lightning strikes and extend product life

Chapter2 Hardware connection

2.1 RJ45 port connection
Connect the RJ45 port of the switch and the corresponding network device via cables, the POE power supply function of the switch is default enabled on the downlink port of the switch, which can be used for IEEE802.3af or IEEE802.3at standards powered devices such as APs, bridges, and network camerasSEVECU
SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
2 Note:
When the switch connected workstations, servers, routers or other ethernet devices the cable length should be within 100 meters;
The Auto-MDI / MDIX ethernet interface is enabled by default. Category 5,the standard network cable or crossover cable can be used for Ethernet connection.
Do not connect the RJ45 port to the phone line
2.2 SFP Port connection
SFP port only support Gigabit fiber module.
Recommended use of standard SFP module products
The process of installing a fiber module on a switch is as follows:
First, grasp the optic fiber module from the side, insert it smoothly along the SFP port slot until the optic fiber module and switch are in close contact;
Second, confirm the Rx and Tx ports of the fiber module when connecting, insert one end of the fiber into the Rx and Tx ports correspondingly, ensure that the Tx and Rx ends of the interface are connected correctly and the other end of the fiber is connected to another device;
Third, please check the corresponding indicator light status after power on. If the light blinking that the link is properly connected, if the light is off , the link is failure, please check the line to confirm that the corresponding equipment is enabled.
Note:
DO NOT excessive bending fiber, the radius of curvature should not be lessthan 10cm;
Ensure the cleanliness of the fiber surface;
Please DO NOT look directly into the optical fiber connector with your eyes as this may cause eye injury
2.3 Check before power on
Check whether the outlet power supply meets the switch specifications;
Check the power, switches, racks and other equipment have been properly grounded;
Check whether the switch and other network devices are connected properly
2.4 Device initialization
The switch automatically initializes when the power switch is turned on.
Indicator will appear the following situation:
After the power is turned on, the power indicator remains on, the other indicator is off at this time;
After about 1 second, all lights except for the power light turn on for about 35 seconds and then turn off; when the SYS light goes flashing, the system runs normally
Port LEDs indicates the connection status of each port, indicating that the switch has started to work normally

Chapter3 Installation

3.1 Installation Precautions
Note:
To avoid improper use of equipment damage and personal injury, please observe the following precautions

  • Installation safety precautions
  • The power should be kept off during the installation, while wearing anti-static wrist, and to ensure well touch between anti-static wrist and skin to avoid potential safety hazard;
  • The switch just works normally when it is powered by the correct power supply. Make sure that the power supply voltage matches the voltage indicated by the switch
  • Before powering on the switch, make sure that the power circuit is not overloaded, which may affect the normal operation of the switch and even cause unnecessary damage
  • To avoid the risk of electric shock, do not open the case while the switch is working. Do not open the case even when it is not powered
  • Before cleaning the switch, unplug the switch from the power cord and do not wipe it with wet cloth. Do not wash it with liquid
  • Temperature and humidity
    To ensure the long-term stability working of the switch , please maintain a certain temperature and humidity environment. High or low humidity easily lead to leakage of insulation materials, deformation and even the corrosion of metal parts, the temperature is too high will accelerate the aging process of insulating materials, seriously affecting the service life of equipment. The normal operation of this series of switches and storage temperature / humidity are as follows
Environmental description temperature Relative humidity
Working environment 0℃~40℃ 10%~90% RH no condensation
Storage environment -40℃~70℃ 5%~90% RH no condensation
  • Altitude
    SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
3Products with this logo are only for safe use in areas below 2000m altitude

  • Dust-proof
    Dust on the switch surface will cause electrostatic adsorption, poor contact of the metal contacts. Although the device itself has done some measures in anti-static, but when the static electricity exceeds a certain intensity, it will still cause fatal damage to the electronic components on the internal circuit board.
    In order to prevent static electricity from affecting the normal operation of the equipment, please note the following:
    1.Regular dust, keep the indoor air clean;
    2.Make sure the equipment is well grounded to ensure smooth transfer of static electricity

  • Electromagnetic interference
    Electromagnetic interference have an impact on the device capacitance, inductance and other electronic components by capacitance, inductive coupling, impedance coupling and other conductive, in order to reduce the adverse effects caused by electromagnetic interference, please note the following:
    1.Power supply system to take the necessary anti-grid interference measures;
    2.Switches should be far away from high-frequency highpower, high-current devices, such as wireless transmitters;
    3.If necessary, take electromagnetic shielding measures

  • Lightning protection
    When a lightning strike occurs, a strong current will be generated in an instant cause fatal damage to electronic equipment. To achieve better lightning protection, please note the following:
    1.Make sure the rack and the ground to maintain good contact;
    2. Make sure the power outlet is in good contact with the earth;
    3. Reasonable wiring, to avoid the internal sense ray;
    4. Outdoor wiring, it is recommended to use the signal lightning protection device

  • Installation desk requirement
    Regardless of whether the switch is installed in a rack or on another horizontal workbench, be aware of the following:
    1. Make sure the rack or workbench is stable, strong, and can withstand at least 5.5Kg weight;
    2. Make sure the rack has a good cooling system, or maintain good indoor ventilation;
    3. Make sure the rack is well grounded, the power outlet and switch are within 1.5 meters
     Prepare tools for installation
    You may need to use a screwdriver during installation, electrostatic wrist strap, fiber optic cable and other tools to prepare your own

3.2 Installation method
standard 19-inch frame
Device is designed according to the size of 19-inch standard rack. It can be easily installed on the rack. The specific installation steps are as follows.

  1. Check rack grounding and stability;

  2. Install the two L-brackets in the accessory on each side of the switch panel and secure with the screws provided in the accessory
    SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
4

  3. place the switch in an appropriate place in the rack and be supported by the bracket. Screw the L-shaped bracket to the guide groove fixed on both ends of the rack to ensure that the switch is stable and horizontally installed on the rack
    SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
5

Note:
Good grounding rack is anti-static equipment, anti-leakage, lightning protection, anti-jamming important guarantee, so to ensure that the rack ground wire properly installed; Installation equipment within the rack from the bottom up, to avoid overload installation;
Avoid placing other heavy objects on switch to avoid accidents;
Ensure heat dissipation and air circulation.
3.3 Web Login
Step1. ,In the normal operation of the device, connect the computer to the switch’s RJ45 port by network cables
SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown below
6 Step2. Manually changed the computer IP address to 192.168.254.X (X is 2 ~ 254), subnet mask is 255.255.255.0![SEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch

  • shown below 7](https://manuals.plus/wp-content/uploads/2023/04/SEVECU- SW2624POE-MGF-250-24-Port-Gigabit-Layer-2-PoE-Switch-shown-below-7.jpg) Step3. Open computer’s browser, type 192.168.254.1 in the address box, hit the Enter key
    Step4. Enter the default username and password “admin” and then click LoginSEVECU SW2624POE-MGF-250 24 Port Gigabit Layer 2 PoE Switch - shown
below 8 Step5. Entered the switch web management interface successfully when you see picture as below, you can begin to configure the switchSEVECU SW2624POE-MGF-250 24
Port Gigabit Layer 2 PoE Switch - shown below 9

Chapter 4: Packaging and product usage suggestions

4.1 Open the package carefully check the following list

Commodity Quantity Description
PoE switch 1pcs No
Power cord 1pcs Optional
Bracket 2pcs Fixed on rack mount
After-sale service card 1 pcs Used for after-ale service
User manual 1pcs Guide users to install switch

4.2 Suggestions

  1. For safety reasons, non-professionals should not open the product casing;
  2. Pay attention to the danger of strong electricity and safe protection when the product is powered on;
  3. Please select the correct power adapter to supply power to the switch. Confirm whether it matches the switch requirements before use.
  4. Do not use the switch in a humid environment to prevent water from entering the fuselage through the casing, resulting in damage to the machine;
  5. Please turn on the power after the line connection is completed;
  6. When the product is powered on, please do not plug or unplug the cable except for special circumstances.
  7. Do not use the switch in places with excessive dust and electromagnetic radiation. Do not use the switch in a place with high temperature and no ventilation;
  8. Please do not place heavy objects on the switch to avoid accidents;
  9. According to the IEEE802.3AF/AT standard, the transmission distance can reach 100 meters by using Category 5 or above wires;
  10. When connecting a switch to multiple PDs, be careful not to exceed the maximum output power of the switch POE.
  11. It is recommended to use the switch indoors. It is recommended to add a waterproof box when using it outdoors.
  12. Considering that the network cable is too long may result in inaccurate data detection. AI Extend and AI PoE cannot be used at the same time.

Note: The pictures in the manual are for reference only, whichever is subject to the actual product.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals