AGRA-GPS CLAAS-JD Bridge Axion and Arion Tractors Instruction Manual

October 29, 2023
Agra-GPS

AGRA-GPS-LOGO

AGRA-GPS CLAAS-JD Bridge Axion and Arion Tractors

AGRA-GPS-CLAAS-JD-Bridge-Axion-and-Arion-Tractors-PRO

Product Information

Agra-GPS CLAAS-JD Bridge for Axion and Arion Tractors
The Agra-GPS CLAAS-JD Bridge is designed to bridge the communication between a CLAAS tractor and a John Deere display (1800, 2600, 2630 or 4640). This allows a JD display to create maps in the John Deere format and also provides straight ABLine autosteer. The operator uses the JD display to create AB-lines. The current position is determined by a John Deere receiver and all this information is used by the CLAAS-JD Bridge to create steering instructions for the CLAAS tractor. All conditions for autosteer such as minimum speed, steering enabled etc. must be met by the CLAAS system before the autosteer engage option in the tractor can be activated. The steering is engaged with the existing Autosteer button in the CLAAS tractor. The JD- Monitor must have a valid AB-line and must be in Steer On mode.

The Agra-GPS CLAAS-JD Bridge is compatible with Axion and Arion tractors with OSI (Open Steering Interface) enabled. The product is manufactured and distributed by Agra-GPS Ltd., based in Stony Plain, AB, Canada.

Introduction
Congratulations on your purchase of the CLAAS JD Bridge. The CLAAS JD Bridge is designed to bridge the communication between a CLAAS tractor and a John Deere display (1800, 2600, 2630 or 4640). This allows a JD display to create maps in the John Deere format and also provides straight AB Line autosteer. The operator uses the JD display to create AB lines. The current position is determined by a John Deere receiver and all this information is used by the CLAAS JD Bridge to create steering instructions for the CLAAS tractor. All conditions for autosteer such as minimum speed, steering enabled etc. Must be met by the CLAAS system before the autosteer engage option in the tractor can be activated. Steering is engaged with the existing “Autosteer” button in the CLAAS tractor. The JD Monitor must have a valid AB line and must be in “Steer On”

NOTICE This manual is not intended to replace the manuals for the CLAAS tractor or the John Deere system. The operator must read and understand the manuals and instructions of these systems, before using the CLAAS JD Bridge.

PRODUCT INSTALLATION

Before installing the CLAAS-JD Bridge, it is important to carefully read the installation manual and operation and safety instructions. Additionally, ensure that all necessary safety labels are in place and replace any missing or damaged labels by contacting Agra-GPS.

To install the CLAAS-JD Bridge:

Step 1: Mounting the CLAAS-JD Bridge

  1. Locate the rectangle opening to the right of the driver’s seat and remove it to find the ATP Module.
  2. Remove the screw and take out the ATP Module. Disconnect the grey 6 Pin connector from ATP.
  3. Connect the Female 6 Pin Connector of the adapter harness that comes with the CLAAS-JD Bridge to the ATP.
  4. Connect the grey 6 Pin connector of the Axion to the male 6 Pin connector of the adapter.
  5. Open the rectangle covering with the power and ISO plugs on the right side of the cab. Behind the cover, there are connectors, remove one of the two green 6 Pin connectors of the power plugs. Connect the connectors of the adapter between them.

Note: Ensure that all steps are carried out carefully and correctly to avoid damage to the product or any other equipment.

Important Safety Information

It is important to read all manuals and instructions carefully before installing and operating the CLAAS-JD Bridge. Agra-GPS Ltd assumes no responsibility for omissions and errors, and any damages resulting from the use of information contained herein. The CLAAS-JD Bridge should not be used if you disagree with the disclaimer. Additionally, observe all safety measures when operating the machine after installing the CLAAS-JD Bridge.

Read this manual and the operation and safety instructions carefully before installing the CLAAS JD Bridge.

  • Follow all safety information presented within this manual.
  • If you require assistance with any portion of the installation or service of your equipment, contact your Agra GPS for support.
  • Follow all safety labels affixed to the system components. Be sure to keep safety labels in good condition and replace any missing or damaged labels. To obtain replacements f or missing or damaged safety labels, contact Agra GPS.

When operating the machine after installing the CLAAS JD Bridge, observe the following safety measures:

  • Be alert and away of surroundings.
  • Do not operate the CLAAS JD Bridge system while under the inf luence of alcohol or an illegal substance.
  • Remain in the operator’s position in the machine at all times CLAAS JD Bridge system is engaged.
  • Determine and remain a safe working distance from other individuals. The operator is responsible for disabling the C LAAS JD Bridge system when a safe working distance has been diminished.
  • Ensure the CLAAS JD Bridge is disabled prior to starting any maintenance work on the machine or parts of the CLAAS JD Bridge system.
  • Follow all safety instructions from the CLAAS system as well as the JD system!
  • The CLAAS JD Bridge must only be used in the field, never on the street!

Electrical Safety

The CLAAS-JD Bridge involves electrical connections; therefore, it is crucial to observe electrical safety measures to avoid accidents, injuries, or damage to equipment. Before installation, disconnect any power sources and ensure the equipment is grounded. Additionally, do not touch any electrical connections while power is on and avoid contact with water or other liquids when handling electrical equipment.

By following safety measures and carefully carrying out installation and operation, users can benefit from the features of the CLAAS-JD Bridge, such as creating maps and straight ABLine autosteer using the JD display.

  • Always verify that the power leads are connected to the correct polarity as marked. Reversing the power leads could cause severe damage to the equipment.
  • Verify that all cables and connectors are not going over sharp edges and are not pinned, as this could cause power shortages and/or malfunctions.

Installation of the CLAAS JD Bridge

Your new 2018 models must have the OSI (Open Steering interface) enabled. Check for options: I40 0010 in your build code. Order no is: 1 403 629 0 in case your tractor was not ordered with the OSI option. Your will also need a “Agr aGPS” unlock from Claas. Order no: 14034320

Step 1: Mounting the CLAAS JD Bridge

  • To the right of the driver seat is a rectangle opening.
  • Remove it and find the ATP Module.
  • Remove the screw and put out the ATP Module. Disconnect the grey 6 Pin connector from ATP.
  • Connect the Female 6 Pin Connector of the adapter harness which comes with the bridge to the ATP.
  • Then connect the grey 6 Pin connector of the Axion to the male 6 Pin connector of the adapter.AGRA-GPS-CLAAS-JD-Bridge-Axion-and-Arion-Tractors- \(5\)
  • Now open the rectangle covering with the power and ISO plugs on the right side of the cab. Behind the cover you can find a couple of connectors.
  • Then remove one of the two green 6 Pin connectors of the power plugs. Connect the connectors of the adapter between them.
  • Then disconnect the green 9 Pin connector of the ISO plug.
  • Also connect the connectors of the adapter between them.

Step 2: Mounting the JD Display
The Claas JD Bridge does NOT include a standard JD Display bracket. We recommend using the Agra GPS roof mounts.

  • An option to mount the JD Display is to use two 1.5 inch RAM mount balls (RAM 202U) and a 4 inch double socket arm (RAM 201U). You can find this under the order number Order the DJD RAM together with the display mounting plate from Agra GPS.

Step 3: Mounting the JD Receiver
The CLAAS JD Bridge does NOT include a standard JD receiver bracket.

  • This picture shows an optional base plate for ClaasArion/Axion roof (Agra GPS order number CL R AX) and the “Deluxe Style” receiver bracket (order number: D JD M W). It is mounted on existing screws in the roof and does not require any drilling in the roof!AGRA-GPS-CLAAS-JD-Bridge-Axion-and-Arion-Tractors- \(11\)

Step 4: Once the receiver is installed, check the settings for the JD Receiver in the display! Also make sure you do a TCM calibration.

The Claas Axion autosteer activation button is located to the back right of the seat. Once the engine is started it must be activated.

It will light solid green when the tractor is ready for autosteer. If the tractor was shut off with this button in the ON position, you will have to toggle it on off before autosteer is enabled!

For tractors from 2018 with Open Steering Interface (OSI) sure that in the AutoSteer settings of the CEBIS there is “Steering system, make from…” as guiding sensor selected. Depending on your software version, it may also show as “ISO Steering” or “Open Steering Interface”:AGRA-GPS-CLAAS-JD-Bridge-
Axion-and-Arion-Tractors- \(13\)

Step 5: Adjusting steering

  • Using the JD display you may a djust your steering performance. Most machines will perform optimally with all JD settings at 100. If a change is required, find an open area where you can travel at target speed and adjust one parameter at a time until you are satisfied with the steering performance.

Step 6: ISO Application
The Claas bridge comes with an ISO application that will be loaded onto the John Deere monitor. The app should automatically store itself on the monitor after the first few minutes of the initial startup. On subsequent runs the app will load itself from memory as soon as possible. The Claas app includes:

  • Option to change work recording mode
  • Option to change croptype list
  • Option to change the machine type
  • Machine info
  • Help page

Where to find the Claas ISO application on the John Deere monitor:

  • On a John Deere 4640 the application will be loaded in the ISOBus VT section on the main page of the display.AGRA-GPS-CLAAS-JD-Bridge-Axion-and-Arion-Tractors- \(16\)
  • On John Deere 1800, 2600, 2630 the application will be shown in the side menu of the John Deere display. The side menu is opened by clicking the button on the bottom right of the display.
  • NOTE: John Deere 1800 and 2600 monitors do not show a loading bar for ISO applications, while 2630 and 4640 monitors do.

If the ISO application is not loaded:

  • Try clearing the monitor’s memory. On 2630 monitors this can be done in the Message Center in the side menu. Go to the Cleanup tab, check controllers, then Begin Cleanup. On 4640 monitors this can be done in the info page of the ISOBus VT. Navigate to the ISOBus VT window and click the info button at the top of the page, then press Clean Up ISO Bus VT.
  • Do a hard reset of the John Deere monitor (Unplug it, then plug it back in).
  • Do a full restart of the machine. Remember the app may take a few minutes to load.

Disclaimer

While every effort has been made to ensure the accuracy of this document, Agra GPS Ltd assumes no responsibility for omissions and errors. Nor is any liability assumed for damages resulting from the use of information contained herein. Agra GPS Ltd shall not be responsible or liable for incidental or consequential damages or a loss of anticipated benefits or profits, work stoppage or loss, or impairment of data arising out of the use, or inability to use, this system or any of its components.
DO NOT USE THE CLAAS JD Bridge IF YOU DISAGREE WITH THE DISCLAIMER.

Contact information
Agra
GPS Ltd.
Box 2585
Stony Plain, AB
T7Z 1X9
CANADA
001 780 990 4052 Phone
www.agragps.com
Release Notice
This is is the February 2018 release (Revision A) of the CLAAS JD Bridge Installation Manual.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals