PENTAIR G-FSB-SWM Azur Swimming Pool Filter Set Installation Guide
- June 9, 2024
- Pentair
Table of Contents
PENTAIR G-FSB-SWM Azur Swimming Pool Filter Set
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY PRECAUTIONS
THESE OPERATING INSTRUCTIONS CONTAIN IMPORTANT INFORMATION ON THE SAFE, PROPER AND ECONOMICAL OPERATION OF THE SWIMMING POOL PUMP. STRICT OBSERVATION OF THE OPERATING INSTRUCTIONS WILL HELP TO AVOID DANGERS, REDUCE REPAIR COSTS AND SHUTDOWN TIMES AND INCREASE THE RELIABILITY AND WORKING LIFE OF THE PRODUCT.
INSTRUCTIONS
The manufacturer has the right to modify the products without previous notice for as far as their characteristics are not really changed by this.
Technical information
- Maximum working pressure 2 bar
- Maximum working temperature 35° C
- Voltage 230 V
- Rpm at 50 Hz 2800 min-1
- Protection IP 44
- Isolation F
- Sound pressure level of kit > 70 dB (A)
Ø 305 | Ø 375 | Ø 475 | Ø 560 | |
---|---|---|---|---|
Filter area (m²) | 0.05 | 0.11 | 0.18 | 0.25 |
Filter flow rate | 5 | 6 | 9 | 12 |
Gravel Ø 3-5 mm (kg) | 5 | 12 | 15 | 20 |
Sand Ø 0.35-0.5mm (kg) | 15 | 30 | 65 | 120 |
Filter empty weight (kg) | 11 | 15 | 18 | 24 |
GENERAL
Check filtration kit for any evidence of damage due to rough handling in
shipment. If filtration kit is damaged notify the carrier immediately. The
filtration kit may only be used for the filtering of swimming pool water,
garden pond water or similar applications.
INSTALLATION INSTRUCTIONS
Please note: there can be specific needs to use filtration kits nearby
swimming pools, garden ponds or such places.
The pump should be placed on a flat, solid foundation, high enough to prevent
flooding of the motor.
Install the filter and pump in a sheltered location,ensuring ventilation and
adequate access for servicing. Place the filter in its permanent location.
Make sure you can reach the valve easily. Then fix the piping. Use only
plastic piping. Size all piping adequately and keep the number of elbows to a
minimum. Use a direct and short suction line with continuous slope in order to
avoid long priming times.
It is essential that the suction line is free of air leaks.The suction line
should always have at least the same size as the suction inlet of the pump.
OPERATION
Look inside and check lower distribution system (6) on broken or loose
laterals (5). Fill tank for 1/3 with water.
Before filling the filter, sand guide (10) should be on the pipe (4). Fill the
filter with the specified quantity of gravel, afterwards with sand. Remove the
sand guide. Put some vaseline on the O-ring (7) of the valve (8). Assemble the
valve (8) to the filter and tighten with the clamp ring (9). Connect the
piping. Turn the valve into position “Rinse” and start the pump for at least 1
minute. Before starting the pump, the strainer basket should be filled with
water up to the level of the suction line. Lubricate the lid O-ring with
silicone each time the lid is removed. Energize the motor, the pump will
prime. The priming time depends on the suction lift and distance to the pool.
Five minutes is a reasonable time. Pump will not lift more than 2 meter.
If pump does not prime, see troubleshooting guide.
CAUTION: NEVER SHIFT VALVE HANDLE POSITION WHILE PUMP IS RUNNING. NEVER DISASSEMBLE VALVE WHILE FILTER IS UNDER PRESSURE.
FILTRATION
- Shift valve handle to position “Filtration”
- Start the pump
- Note here the pressure of the pressure gauge (11).
TO CLEAN ( BACKWASH) THE FILTER
When the pressure rises approximately 0.5 bar above the recorded pressure it
is time to backwash.
- Shut off the pump
- Shift the valve handle to “Backwash”
- Start pump and let it run until water is clean (about 3 minutes).
- Shut off the pump
- Shift valve handle to position “Rinse” and start the pump
- Start pump and run for approximately one minute
- Shut off the pump
- Shift valve handle to position “Filtration” and start the pump
MAINTENANCE
The strainer basket should be daily removed and cleaned. Never operate the pump without its strainer basket. The filter needs no maintenance.
CAUTION: ALWAYS DISCONNECT THE POWER SUPPLY TO THE PUMP BEFORE SERVICING
WINTERIZING
Protect the pump, the filter and the piping from freezing. Open the drain (3)
and shift the valve handle to “Backwash”. Remove the pump to a dry and warm
room. Do not wrap the motor with plastic covering as condensation may damage
the pump.
In installations where the pump can not be drained, a 40% propylene glycol, 60% water solution will protect to -46°C. Do not use other anti-freeze solutions, these are all highly toxic and will damage the pump.
ELECTRICAL CONNECTION
The electrical motor must be wired by a professional according to the
installation instructions of your local electricity company.
CAUTION: AT THE INSTALLATION OF THE PUMP A MOTOR SECURITY HAS TO BE FORESEEN WHICH SHOULD BE IN ACCORDANCE WITH THE NOMINAL POWER OF THE MOTOR.
Monophase
Swimmey -8M| P1 0.43 kW / 230 V
P2 0.18 kW / 230 V
| 2.2 A
---|---|---
Swimmey -10M FreeFlo – 10M| P1 0.48 kW / 230 V
P2 0.25 kW / 230 V
| 2,35 A
3,0 A
Swimmey -12M FreeFlo – 12M| P1 0.55 kW / 230 V
P2 0.37 kW / 230 V
| 2,5 A
3,0 A
Swimmey -15M FreeFlo – 15M| P1 0.65 kW / 230 V
P2 0.50 kW / 230 V
| 3,0 A
4,2 A
Swimmey -19M FreeFlo – 19M| P1 1.10 kW / 230 V
P2 0.75 kW / 230 V
| 4,5 A
5,5 A
The supply voltage should be within ± 5% of the design voltage, specified on the nameplate of the motor. Single-phase motors should be connected at the terminals as indicated in the junction box.
CAUTION: MAKE SURE THAT YOU INTERRUPT THE POWER SUPPLY TO THE CABLES WHEN
CONNECTING THE CABLES OF THE PUMP
Every motor must be permanently grounded.
An earth safety or circuit breaker switch with a sensitivity of 30mA should
always be included at the installation. The wiring size and the type of fuses
(minimum H05RN-F) should be selected in accordance with the motor capacity.
CAUTION: CONNECTIONS WHICH ARE NOT CONFORM
TO THE ABOVE-MENTIONED SAFETY INSTRUCTIONS, ARE NOT COVERED BY THE WARRANTY.
REPLACING THE SAND
Disassemble the drain (3) and let the water flow out. Remove the sand. The
sand in the filter must be changed every 5 years.
TROUBLESHOOTING
Pump will not prime
- No water in strainer pot
- Strainer pot is not tight
- Damage lid O-ring
- Water level is below skimmer
- Strainer basket or skimmer basket is clogged
- Closed valve in piping system
- Air leak in suction line
Motor does not turn
- Power switch is off
- Circuit breaker has tripped
- Pump is off-mode of a timer controlled circuit
- Motor terminal connections are incorrect
- Motor shaft is locked by bad bearing
- Impeller is locked by debris
Low flow-high filter pressure
- Filter is dirty
- Restriction in return line
Low flow-low filter pressure
- Strainer basket or skimmer basket is clogged
- Clogged impeller
- Air leak in suction line
- Restriction in suction line
Noisy pump
- Air leak in suction
- Foreign matter in pump housing
- Cavitation
EXPLODED VIEW
item | Description | QTY |
---|---|---|
1 | Platform for sand filtration kit | 1 |
2 | Blow molded shell Azur | 1 |
3 | Drain kit | 1 |
4 | Grey PVC pipe Ø 50 x 1.8 mm | 1 |
5 | Filter nozzle for filter nozzle star SS6 | 6 |
6 | Hub for filter nozzle star | 1 |
7 | O-ring NBR 70 shore Ø 50 x 2.5 mm | 1 |
8
| Black 4-way ECO valve Ø 1 1/2” TM| 1
Black 6-wa y valve 1 1/2” Tm (50mm connection)| 1
9| Plastic clamp with ss screw and nut| 1
10| Sand guide| 1
11| Pressure gauge 1/4” NPT bottom connection| 1
12| pump: “Swimmey” 230 V single ph / “FreeFlo” 230 V single ph| 1
13| Hardware kit| 2
14| Connecting hose (inside Ø 38 mm)| 1
15| Hose nozzle PVC Ø 38 x 11/2” BSP| 2
16| Hose clamp (stainless steel)| 2
Warranty
Pentair Water is not responsible for transport damage. In case of damage notify carrier immediately.
Warranty period:
Limited warranty: 2 years
Customer Support
HERENTALS, BELGIUM (8:30 A.M. to 4:30 P.M.) CET
Website: www.pentairpooleurope.com
Declaration of Conformity
We declare, under our sole responsibility, that the product identified in this
declaration, and to which this declaration relates, are in conformity with the
protection requirements of Council Directive 2006/42/EG
The manufacturer, Pentair, has the right to modify the products without previous notice for as far as their characteristics are not really changed by this.
© 2013 Pentair. All rights reserved
This document is subject to change without notice
Trademarks and disclaimers: FreeFloTM, SwimmeyTM,, AzurTM and Pentair® are
trademarks and/or registered trademarks of Pentair and/or its affiliated
companies. Unless noted, names and brands of others that may be used in this
document are not used to indicate an affilitation or endorsement between the
proprietors of these names and brands and Pentair. Those names and brands may
be the trademarks of those parties or others.
INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN 30, 2200 HERENTALS – BELGIUM, WWW.PENTAIRPOOLEUROPE.COM
Copyright – Limited License: except as specifically permitted herein, no portion of the content on this document may be reproduced in any form or by any mean without the prior written permission of Pentair International SRL.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>