Overview

NOTICE
Remove, where present, the magazine and all ammunition from your firearm.
Open the breech and ensure there is no round in the chamber.
Point the firearm in a safe direction and decoct it.
Engage, where possible, the safety.
Make sure to discharge the gun and put its safety catch on prior to mounting the sight.
Avoid looking directly into the sun, light arcs or other high-intensity light sources to prevent eye damage.
The equipment includes small components.
Keep away from children!

GENERAL INFORMATION

The reflex sights are excellent aiming optics devices of up-to-date design.
With their small size and low weight as well as their compact shape without using a tube, they offer various possibilities of use on hunting and sport.
The solid workmanship, the high optical performance, an attractive design and the functional reliability even in case of extreme weather conditions will cause your NOBLEXNV G to become indispensable.

DELIVERY EXTENT

The delivery extent includes:

  • 2 M3x8 countersunk socket screws (TORX) to fasten to the mounting plate
  • 2 self-adhesive sealing foils
  • 1 T10 hexagon wrench key (TORX) to tighten the fastening screws
  • 1 screwdriver (0.4 x 2.0)
  • 1 scale wheel with device-specific scale disc
  • 1 coin cell (3 V, CR 2032)
  • Operating instructions

TECHNICAL DATA

Magnification 1.07x
Sight window 25 mm x 20 mm
Elevation adjustment range ± 360 / 100 m
Windage adjustment range ± 270 / 100 m
Adjustment value per scale division 3 cm / 100 m

Overlap measure in case of model:

  • 3.5 MOA
  • 7.0 MOA

|

  • 10 cm / 100 m
  • 20 cm / 100 m

Parallax-free sighting distance| 40 m
Power supply| 3 V, CR 2032 lithium coin cell
Dimensions (L x W x H)| 46.0 mm x 32.0 mm x 31.4 mm
Color of target dot| Red
Tightness| Water tight
Weight (without mounting accessories)| 36 g

Let a gunsmith do the NV G mounting and the shooting adjustment of the gun.

PUTTING INTO OPERATION

For the power supply, one CR 2032 lithium battery (3 V) is needed.
Any other kind of power supply is excluded.
Insert the battery into the battery compartment at the bottom of the enclosure such that the labeling of the battery with the marking of the plus pole is visible.
A danger to damage the electronics due to an incorrect insertion does not exist.
For a better contact, a magnet causes the battery to be pulled toward the gold-plated contact plate on the circuit board.
The contact area is to be kept clean (cleaning using spirit).

REPLACING THE BATTERY

To replace the battery, the NV G is to be removed from the mounting plate.
The battery compartment is located at the bottom of the device.
The exhausted battery is taken out by putting the wrench key (or the screwdriver) onto the notch located at the right bottom side.
When the battery has been replaced, the sight is put back onto the mounting plate and is fastened with the 2 countersunk screws.
Due to the precision positioning pins, a new shooting adjustment is not required.

ACTIVATING AND ADJUSTING THE ILLUMINATED DOT

To activate, simply press one of the brightness adjustment buttons on the side.
Please note that the previously set brightness level will be reactivated, which may not be directly perceived in bright light.
Pressing the right adjustment button will increase the brightness of the dot step by step until the maximum brightness has been reached.
When the maximum brightness has been reached, the dot will flash.
Pushing the left button reduces the brightness.
To switch the device off, both keys must be pressed simultaneously, which will also save the currently set brightness level.
The reflex sight will automatically switch off automatically after 3 hours when not in use.
In this case, the previously set brightness level will not be saved.

BATTERY WARNING
A flashing signal at 5 second intervals indicates when the battery should be replaced in the near future.
When there is switched on again, the battery voltage is checked again.
If the battery could recover or the light conditions have changed, it can happen that a repeated warning is not indicated for the time being.
Despite the battery warning, the sight device still can be operated for a longer time period (reserve of about 20 %).
However, the brightness of the light dot increasingly reduces and a brightness setting higher than that made before can be necessary.

MOUNTING

Due to multitude of different adapter plates with the DOCTER sight footprint, the NV G can be mounted to nearly all gun types without any problems.
Your gunsmith will choose a convenient mounting according to your requirement and to the gun type.
Independently of the used mounting type, the upper side of the adapter plate has 4 precision positioning pins.
The sealing foil included in the delivery extend has to be pasted onto the adapter plate.
For that purpose, pull off the covering layer and paste the seal onto the adapter plate where you have to consider the pre punched holes.
The NV G is watertight only if the sealing foil has been applied properly.
Put the NV G onto the mounting plate where you have to consider the fastening threads and the positioning pins.
Then, fasten the device using the delivered countersunk screws.
The combination of screw fastening and precision positioning pins prevents the hit point position from shifting during the use.

SHOOTING ADJUSTMENT

Ex factory, the optical system of the NV G is parallax- freely adjusted to a distance of 40 m.
You have to choose a shooting adjustment distance that meets your requirements to the NV G.
The NV G has an elevation adjustment element (1) and a windage adjustment element (2) that are separate from each other.
These elements are arranged at the top or at the right side of the device and are marked with rotation direction arrows.
You will make the adjustment through of the slotted screws using the delivered scale wheel and the delivered screwdriver (0.4 x 2.0).

Attention: Prior to each adjustment, the locking screws (3) have to be loosened.

The elevation adjustment and the windage adjustment can be made independently of each other.
The available adjusting range allows the compensation of inaccuracies on mounting as well as a ballistics correction.
The windage adjustment has end stops in both directions.
In case of the elevation adjustment, there has to be considered that the end stop in downward direction is present in the mounted state only.
Please consider that the adjustments are clamped if there has been screwed up to the end stop in the respective different adjusting direction.

ELEVATION AND WINDAGE ADJUSTMENT

To avoid the adjustment mechanism from being damaged, loosen the locking (3) of the adjustment mechanism before doing any elevation and/ or windage adjustment.
For that purpose, cause the two clamping screws at the rear of the NV G to be moved back a quarter turn from the end stop (anticlockwise).
To do that, use the delivered screwdriver (0.4 x 2.0).
The adjustment must be actuated without any problems.

ADJUSTING THE HIT POINT POSITION
To adjust the hit point position, a scale disc is included in the delivery extent.
Push the scale disc onto the delivered screwdriver where the scale has to be directed toward the handle.
Now, cause the screwdriver to be set to the elevation adjustment (1) or to the windage adjustment (2).
According to the rotation sense shown on the enclosure and on the scale wheel, you will get an aimed elevation or windage adjustment of the hit point.
To read the division, use the markings (4) beside the adjustment elements or a distinctive enclosure edge.
Adjusting And Position

If you determine a deviation from the target point (light dot) to the hit point after the first shoot, you can correct it as follows:

  • Hit point below the target point (gun shoots too deep):
    Turn the adjustment screw in the Up direction.

  • Hit point above the target point (gun shoots too high):
    Turn the adjustment screw in the Down direction.

  • Hit point to the left of the target point (gun shoots too far left):
    Turn the adjustment screw in the R (Right) direction.

  • Hit point to the right of the target point (gun shoots too far right):
    Turn the adjustment screw in the L (Left) direction.

One scale division corresponds to a shift of 3 cm at 100 m or to 1 angular minute.
In case of other shooting adjustment distances, the adjustment value changes proportionally to the distance.
For example: 1,5 cm at 50 m or 3 mm at 10 m

ACTIVATING AND ADJUSTING THE ILLUMINATED DOT

To activate, simply press one of the brightness adjustment buttons on the side.
Please note that the previously set brightness level will be reactivated, which may not be directly perceived in bright light.
Pressing the right adjustment button will increase the brightness of the dot step by step until the maximum brightness has been reached.
When the maximum brightness has been reached, the dot will flash.
Pushing the left button reduces the brightness.
To switch the device off, both keys must be pressed simultaneously, which will also save the currently set brightness level.
The reflex sight will automatically switch off automatically after 3 hours when not in use.
In this case, the previously set brightness level will not be saved.

MAINTENANCE AND CARE

To clean the optics, use glasses cleaning clothes.
Before doing that, the optics surfaces should be carefully cleaned using a soft and clean cloth or a hair brush where no chemical solvents are to be applied.
Heavy dirt should be removed using distilled water.
Otherwise, furring’s can occur on the surfaces.
In case of possibly function-affecting damages, the device has to be sent to an authorized service workshop.

HINTS
Due to their specific construction, NOBLEX red-dot reflex sights do not have a diopter compensation unit or other function units that compensate for the visual defect of the human eye.
Thus, all individual visual defects of the respective shooter have a direct effect on the contour of the perceived light dot.
Seeming ovality, sickle-shaped distortion, „star clusters“ or a „frayed“ contour of the dot do not mean a defective device, but rather and exclusively mean a physiological change of the eye (astigmatism).
Then, it is recommended to use corrective glasses or to have the eyes checked by an ophthalmologist

WARRANTY

We grant a warranty of two years in the following extent:

  1. During this period, complaints based on defects in material and workmanship are remedied at no charge.
    We reserve the right to do such a clearance by repair, by replacement of defective parts or by provision of a similar, perfectly functioning product.

  2. If the warranty is claimed, the optical device along with the proof of purchase (with address and signature) as well as the date of selling by your dealer and a description of the present complaint is to be sent to the responsible NOBLEX agency, at your own expense.

  3. Claims for warranty performances do not exist in case of improper usage, interventions and repairs by a service provider that is not authorized by our company.

  4. Wear and tear, wear parts and miscellaneous accessories are excluded from a warranty.
    This also applies to diverse damages of the product surface.

We do not assume any liability for further-going direct or indirect damages, irrespective of type and extent.
It applies the law of the Federal Republic of Germany.
Place of jurisdiction is Wetzlar

Illustrations used in the manual may differ from the real products/articles.
No liability shall be assumed for product changes, especially in the course of technical enhancements, as well as model changes or printing errors.

Please note when disposing of sighting mechanisms with electronic parts:

| Sighting mechanisms equipped with an illuminated reticle, thus design- related containing electronic parts, must not be mixed into general household garbage when used up.
Bring the material to the corresponding collection points for proper handling, retrieval and recycling; they will be taken from you without fee.
Properly disposing the product at the corresponding collection points conduces to environmental protection, and prevents potential repercussions on humans and environment resulting from incorrect usage of waste.
---|---

Please note when disposing of batteries of sighting mechanisms:

| Batteries must not be disposed in household garbage.
Please dispose spent batteries using the provided retrieval and recycling system.
The consumer is legally required to turn in dead and no longer usable batteries.
Retrieval is possible at all marked collection points.
---|---

CUSTOMER SUPPORT

NOBLEX E-Optics GmbH
Seerasen 2
D-98673 Eisfeld
Tel: +49 (0) 3686 688 902-0
info@noblex-germany.com
www.noblex-germany.com
Logo.png

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals